ID-1833-1907 CZCss ss ss ss
ss ss ss
ss ss ss ss ss ss ss
ss ss
ss
ss
ss
w w w
w w
w w
w
w w w
w w
w w w
s MS
1098
2636.08
pp pp
pp
s MS
1081
2634.58
WV
1204
WV
1213
WV
1214
WV
1218
WV
1220
WV
1221
t
t
sd
sd
IRRV
1340
IRRV
1515
ST - KEEP RIGHT
1168
ST - KEEP RIGHT
1175
SS
1237
HCB - AT FL
1032
2634.76
GWA - W TO EPP
1169
GWA - W TO EPP
1226
HCB - AT FL
1243
2634.73
CP - SCRIBED X
1
2637.43
CP - SPIKE
2
2637.40
CP - SCRIBED X
3
2635.19
CP - FND SCRIBED NUMBER 30
4
2635.96
el
el
t
SD
ss
ss ss
ss ss
ss ss
ss ss
ss
ss
ss
IRR
IRR IRR IRR IRR IRR IRR
IRR
PROP. INFILTRATION
BED #1
EX. CURB TO BE DEMOLISHED
NEW CURB TO BE INSTALLED
APPROXIMATE LIMITS OF
ABANDONED SEPTIC FIELD TO
BE REMEDIATED PER
GEOTECHNICAL
RECOMMENDATION
(PLACED BY RECORD
DRAWINGS)
APPROXIMATE LOCATION OF
EXISTING INFILTRATION BED
APPROXIMATE LOCATION OF
EX. STORM DRAIN LINE
EX. DRAINAGE
INLET
EX. STORM SUMP INLET
PROP. DRAINAGE
INLET
PROP. DRAINAGE
INLET
55'
55'
60'
30'
55' 55'
60'
30'
187'
11'
11'
11' 11'
319'
176'
120'
120'
115'
30'
6'
APPROXIMATE LOCATION OF EX.
SANITARY SEWER LINE
(PLACED BY RECORD DRAWINGS)
PROPOSED CURB RAMP
PROP. SAND/OIL
SEPARATOR
±4500 SF OF EXISTING ASPHALT
PAVEMENT TO BE REMOVED FOR
INSTALLATION OF CONCRETE PAD
R5'
R10'
20.63'
149.8'
187.36'
138.62'
162.01'
51.2'
10.1'
5.5'
R35'
EX. SIDEWALK
10'
20'
SITE TRIANGLE
PER 11-3A-3
SD SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD SD SD SD SD SD SD
IRR
IRR
IRR
IRR IRR
IRR IRR IRR
IRR
IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR
IRR
IRR IRR
20.68'
57'
PROPOSED 1.5" IRRIGATION LINE
TO BE INSTALLED PER NAMPA &
MERIDIAN IRRIGATION DISTRICT
STANDARDS
PROPOSED LIGHT
POLE TYP.
PROPOSED LIGHT
POLE TYP.
N. TOUCHMARK AVE.
E. COMMERCIAL ST.
TRUCK TURNING
AND STAGING
AREA
EX1
EX2
EX3
EX4
EX5
EX6
EX7
EX8
EX9
EX10
EX11
EX12
EX13
PR1
PR2
PR3
PR4
PR5
PR6
PR7
PR8
PR9
PR10
MULCHED PLANTING
BED PER TREE PLANTING
DETAIL AND LANDSCAPING
NOTES (TYP.)
MULCHED PLANTING
BED PER TREE PLANTING
DETAIL AND LANDSCAPING
NOTES (TYP.)
LIMIT OF DISTURBANCE, TYP.
PROPOSED LIGHT
POLE TYP.
ir
SBX
1712
s MS
1856
2639.51
co
SCO
2112
2639.54
s
MS
2113
2640.45
MS
2114
2639.74
FH - IS 1 FT TO N
1865
IRRV
1909
IRRV
1911
WV
1914
TR - DEC 12 IN DBH 25 FT CANOPY
2021
TR - DEC 12 IN DBH 25 FT CANOPY
2022
TR - DEC 6 IN DBH 25 FT CANOPY
2023
TR - DEC 10 IN DBH 25 FT CANOPY
2024
TR - DEC IN DBH 25 FT CANOPY
2025
LP - IS 1 FT TO N
1713
IRRV
1753
e
EJB
1772
2639.09
e
EJB - 8 IN DIAM
1910
2639.21
WELL
1912
2638.76
CP - MAG NAIL
5
2638.44
CP - 58 PPC HORROCKS CONTROL
6
2637.10
CP - SCRIBED X
20
2638.77
CP - SCRIBED X
21
2638.75
w w w w w w w w w w w w
w
ss
ss ss
ss
ss ss
ss
ss ss
ss
ss
ss
IRR
IRR
IRR IRR
IRR
IRR IRR
IRR
PROP. INFILTRATION
BED #2
PROP. DRAINAGE
INLET
150'
209'
209'
55'
55' 30'
30'
25'
40'
APPROXIMATE LIMITS OF ABANDONED
SEPTIC FIELD TO BE REMEDIATED PER
GEOTECHNICAL RECOMMENDATION
(PLACED BY RECORD DRAWINGS)
EX. WATER LINE
EX. SANITARY SEWER LINE
EX. ABANDONED
SANITARY SEWER
MANHOLE
APPROXIMATE LOCATION OF EX.
SANITARY SEWER LINE
(PLACED BY RECORD DRAWINGS)
EXISTING IRRIGATION CONTROL
BOX AND LIGHT POLE TO BE
RELOCATED OUTSIDE OF DRIVE
AISLE/TRAILER PARKING
±9500 SF OF EXISTING ASPHALT
PAVEMENT TO BE REMOVED FOR
INSTALLATION OF CONCRETE PAD
PROP. SAND/OIL
SEPARATOR
LIMIT OF DISTURBANCE, TYP.
EX. CHAIN LINK FENCE
SD SD
SD
SD SD
IR
PROPOSED LIGHT
POLE TYP.
PROPOSED LIGHT
POLE TYP.
PROPOSED LIGHT
POLE TYP.
SET TOP OF ROOT CROWN 2"
ABOVE ADJACENT CURB &
SIDEWALK GRADE
NOTES:
SEE NOTE 3
1. SHAPE SOIL SURFACE
TO PROVIDE 3' DIAMETER
WATERING RING
2. MULCH TREE PIT MIN
5'-0"Ø MULCH RING.
3. TREE PIT DEPTH=
ROOTBALL DEPTH
(MEASURE BEFORE
DIGGING TO AVOID
OVEREXCAVATION)
4. GRANULAR FERTILZER
PLACED AFTER PLANT
HOLE IS BACKFILLED.
QUANITY BASED ON TREE
GROWERS
RECOMMENDATIONS
5. INSTALLATION
INCLUDES REMOVEL OF
WATERING RING 1 YEAR
AFTER INSTALLATION.
UNDISTURBED SUBGRADE
(PROVIDES FIRM BASE SO
THAT ROOTBALL WILL NOT
SINK)
2"-3" MULCH DEPTH
(TAPERED AT TRUNK)
FINISHED GRADE
ROUGHEN SIDES OF
PLANTING HOLE MAXIMIZE
EXCAVATED AREA WITHOUT
UNDERMINING ADJACENT
PAVING/CURB OR GRASS
18" DEEP ROOT BARRIER
(TYP. WITHIN 10' OF
PAVING
REMOVE ALL WIRE &
STRING, AND REMOVE
ALL BURLAP FROM TOP
2/3 OF ROOTBALL
NATIVE BACKFILL SOIL
AMENDMENT WITH 25% (@1/3
CU YD) DECOMPOSED
ORGANIC MULCH AMENDMENT
FOR ENTIRE TREE PIT AREA X
ROOTBALL DEPTH
ENSURE NO VOIDS OR AIR
POCKETS UNDER AND
AROUND ROOTBALL
MULCH AREA TO BE CLEAR OF
GRASS, WEEDS, ETC. TO
REDUCE COMPETITION WITH TREE ROOTS
MIN WIDTH OF TREE PIT = 2 TIMES
ROOTBALL DIAMETER OR
5' WHICHEVER IS GREATER
1.5'
2'-0"MIN
H:\!2019\ID-1833-1907 Albertson's Parking Lot Expansion\Project Data\02 CAD\2.03 Sheet Files\Concepts & Exhibits\ID-1833-1907 CZC.dwg Michael O'Reilly 9/9/2019 10:27 AM
WARNING
0 1/2 1
IF THIS BAR DOES NOT
MEASURE 1" THEN
DRAWING IS NOT TO
SCALE
PROJ. NO:
09/9/19
DRAWING INFO
DATE
SCALE
REV # DATE
*SEE 2nd SHEET FOR LISTING
OWNER: CITY:
www.horrocks.com
2775 W. Navigator Dr., Suite 210
Meridian, ID 83642
(208) 895-2520
PAGE
NORTHWEST PARKING LOT LAYOUT SOUTHEAST PARKING LOT LAYOUT
H
O
R
R
O
C
K
S
E
N
G
I
N
E
E
R
S
N
0 1'
SCALE: 1" = 20'
ABS SUNDRIES PARKING EXPANSION - CZC SITE AND LANDSCAPING PLAN C1.00
ALBERTSONS
COMPANIES
CITY OF MERIDIAN
LEGEND:
PROP. CONCRETE PAVEMENT
PROP. INFILTRATION BED
PROP. DRAINAGE INLET
PROP. 50/50 BLUE/RYE SOD
PROP. STREET TREE
EX. TREE TO REMAIN
ENGINEER
HORROCKS ENGINEERS
2775 W. NAVIGATOR DR.
SUITE 210
MERIDIAN, ID 83642
CONTACT: SCOTT DUFFIN, P.E.
PHONE: 208-895-2520
DEVELOPER
MARGIE FRITZ
MARGIE.FRITZ@ALBERTSONS.COM
208-887-4001
ABS ID-O LLC
3649 E. COMMERCIAL CT.
MERIDIAN, ID 83642
SITE INFORMATION
TOTAL LOD AREA: 114,863 SF (2.64 AC)
ZONING REQUIREMENTS
· ZONING: CITY I-L, LIGHT INDUSTRIAL
· ROAD SETBACK = 10'
PARKING INFORMATION
· STANDARD PARKING STALLS REQUIRED: 0
· STANDARD PARKING STALLS PROVIDED: 0
· FULL SIZE TRAILER STALLS PROVIDED (55'x11'): 52
· 28' TRAILER STALLS PROVIDED (30'x11'): 48
· HANDICAP PARKING STALLS REQUIRED: 0
· HANDICAP PARKING STALLS PROVIDED: 0
PLANTING INFORMATION
· TREES REQUIRED (1 TREE PER 35' FRONTAGE): 10
· TREES PROVIDED 10
SITE NOTES:
1. ALL PROPOSED PARKING IS SEMI-TRAILER PARKING
THEREFOR NO ADDITIONAL ACCESSIBLE OR BICYCLE PARKING
HAS BEEN PROVIDED.
2. ALL EX. TREES ARE TO REMAIN AND ARE TO BE PROTECTED IN
PLACE BY A CONSTRUCTION FENCE DURING CONSTRUCTION
ACTIVITIES.
3. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL
UNDERGROUND UTILITIES AS WELL AS ANY STRUCTURE THAT
ARE TO REMAIN. ANY DAMAGE TO UTILITIES/STRUCTURE THAT
ARE TO REMAIN SHALL BE REPAIRED BY THE CONTRACTOR AT
NO ADDITIONAL EXPENSE.
TREE
NUMBER
CALIPER
SIZE
STATUS
EX1
EX2
EX3
EX4
EX5
EX6
EX6
EX7
EX8
EX9
EX10
EX11
EX12
EX13
PR1
PR2
PR3
PR4
PR5
PR6
PR7
PR8
PR9
PR10
6IN
3IN
4IN
6IN
4IN
6IN
6IN
8IN
6IN
6IN
10IN
10IN
2IN
8IN
2IN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
EX. TO REMAIN
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
PROPOSED
BOTANICAL NAME
ACER RUBRUM
ACER RUBRUM
ACER RUBRUM
ACER RUBRUM
ACER RUBRUM
ULMUS
ULMUS
ULMUS
ULMUS
ULMUS
GLEDITSIA TRICANTHOS
PRUNUS VIRGINIANA
GLEDITSIA TRICANTHOS
ACER RUBRUM
ACER RUBRUM
KOELREUTERIA PANICULATA
ACER RUBRUM
PRUNUS VIRGINIANA
PRUNUS VIRGINIANA
PRUNUS VIRGINIANA
PRUNUS VIRGINIANA
PRUNUS VIRGINIANA
ACER RUBRUM
ACER RUBRUM
NOTE:
1. ALL PROPOSED TREES ARE CLASS II TREES.
2.PROPOSED TREES MAY BE EXCHANGED AT REQUEST OF OWNER TO A DIFFERENT TREE SPECIES
APPROVED BY THE MERIDIAN LANDSCAPE ORDINANCE.
3. EXISTING TREE SPECIES WERE DETERMINED USING READILY AVAILABLE IMAGERY. SOME
SPECIES MAY VARY FROM WHAT IS LISTED. ALL EXISTING TREES ARE TO REMAIN.
LANDSCAPING NOTES:
1. THE CONTRACTOR SHALL REPORT ANY ISSUES WITH THE SITE
CONDITION TO THE ENGINEER BEFORE STARTING WORK.
2. ALL EX. TREES ARE TO REMAIN AND ARE TO BE PROTECTED IN
PLACE BY A CONSTRUCTION FENCE DURING CONSTRUCTION
ACTIVITIES.
3. REFERENCE THE TREE PLANTING DETAIL (THIS SHEET) FOR
INFORMATION ON TREE AND MULCH INSTALLATION.
4. ALL PLANT MATERIAL SHALL MEET OR EXCEED THE MINIMUM
FEDERAL STANDARDS AS REGULATED BY ANSI Z60.1 "AMERICAN
STANDARD FOR NURSERY STOCK."
5. ALL TREES, SHRUBS, AND OTHER PLANT MATERIAL SHALL BE
PLANTED USING ACCEPTED NURSERY STANDARDS AS PUBLISHED
BY THE AMERICAN ASSOCIATION OF NURSEYMEN (LATEST EDITION)
INCLUDING HOLE SIZE, BACKFILLING, AND FERTILIZATION.
6. ALL TOP SOIL SHALL BE AMENDED AT A RATIO OF 3 CY OF
ORGANIC MATTER PER 1000 SF.
7. TOP SOIL SHALL BE LOOSE FRIABLE, SANDY LOAM, CLEAN AND
FREE OF LARGE ROCKS AND PLANT MATERIAL. EXISTING ON-SITE
TOP SOIL MAY BE USE IF IT MEETS THE REQUIREMENTS.
8. MULCH SHALL BE 1" MINUS BARK MULCH AND SHALL BE PLACED
PER ISPWC STANDARDS.
9. CONTRACTOR TO PROVIDE AN AUTOMATIC IRRIGATION SYSTEM
THAT FULLY COVERS THE PROPOSED PLANTING AREAS.
TREE PLANTING DETAIL
2IN
2IN
2IN
2IN
2IN
2IN
2IN
2IN
2IN
HONEY LOCUST
COMMON NAME
CANADA RED CHOKECHERRY
CANADA RED CHOKECHERRY
CANADA RED CHOKECHERRY
CANADA RED CHOKECHERRY
RED MAPLE
RED MAPLE
HONEY LOCUST
RED MAPLE
RED MAPLE
RED MAPLE
RED MAPLE
RED MAPLE
RED MAPLE
RED MAPLE
RED MAPLE
GOLDENRAIN TREE
CANADA RED CHOKECHERRY
CANADA RED CHOKECHERRY
ELM
ELM
ELM
ELM
ELM
MATURE
SIZE HxW
45'x45'
40'x30'
40'x30'
40'x30'
40'x30'
40'x30'
45'x45'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
35'x35'
20'x20'
20'x20'
20'x20'
20'x20'
20'x20'
20'x20'
30'x30'