Loading...
CA-3_ElevationsVERIZON SITE: BOI MAVERICK CROWN CASTLE SITE: BU #: 822731 BOISE_CALL_CENTER 2100 S SILVERTONE WAY MERIDIAN, ID 83642 ADA COUNTY 100'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DESCRIPTION A 05/09/19 PRELIMINARY REVIEW 0 06/24/19 100% CONSTRUCTION QA/QC PD PD DRAWN RCD TJB SHEET NUMBER: SHEET TITLE: A-3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. REVISION: 0 INFINIGY F ROM Z E R O T O I NFI N I GY the solutions are endless 1505 WESTLAKE AVE N, SUITE 800 SEATTLE, WA 98109 50 116TH AVE SE, SUITE 210 BELLEVUE, WA 98004 JURISDICTIONAL APPROVAL: WEST ELEVATIONS 4' 0" 4' 22"x34" SCALE: 3/16" = 1'-0" 2 EXISTING WEST ELEVATION 4' 0" 4' 1 PROPOSED WEST ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 2' 22"x34" SCALE: 3/16" = 1'-0" 11"x17" SCALE: 3/32" = 1'-0" 2' NOTES: · THESE DRAWINGS ARE NOT INTENDED TO BE A VERIFICATION THAT THE STRUCTURE OR MOUNTS ARE ADEQUATE TO SUPPORT THE PROPOSED LOADING. VERIFICATION THAT THE EXISTING STRUCTURE AND MOUNTS CAN SUPPORT THE PROPOSED LOADING SHALL BE PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER PRIOR TO CONSTRUCTION. · CONTRACTOR TO REFER TO THE STRUCTURAL ANALYSIS AND MOUNT ASSESSMENT AND VERIFY LOADING WITH THE MOST RECENT RFDS PRIOR TO CONSTRUCTION. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. EXISTING PLASTIC FENCE EXISTING VERIZON ICE BRIDGE EXISTING EQUIPMENT CABINET BY OTHERS EXISTING VERIZON EQUIPMENT SHELTER TOP OF EXISTING MONOPOLE ELEV. = ±100'-0" REF., ±101'-3" AGL ℄ OF EXISTING VERIZON ANTENNAS ELEV. = ±79'-0" REF., ±80'-3" AGL ℄ OF EXISTING ANTENNAS BY OTHERS ELEV. = ±96'-0" REF., ±97'-3" AGL ℄ OF EXISTING VERIZON ANTENNAS ELEV. = ±78'-0" REF., ±79'-3" AGL TOP OF EXISTING ANTENNAS BY OTHERS ELEV. = ±100'-0" REF., ±101'-3" AGL EXISTING PANEL ANTENNAS BY OTHERS MOUNTED TO MONOPOLE, TYP. EXISTING VERIZON CABLING ROUTED UP OUTSIDE OF MONOPOLE - SEE ANTENNA SCHEDULES ON SHEET A-4 EXISTING CROWN CASTLE MONOPOLE EXISTING VERIZON ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPOLE - SEE SHEET A-4 PROPOSED VERIZON ANTENNAS WITH ASSOCIATED EQUIPMENT MOUNTED TO MONOPOLE - SEE SHEET A-4 TOP OF EXISTING VERIZON ANTENNAS ELEV. = ±82'-11" REF., ±84'-2" AGL TOP OF EXISTING MONOPOLE ELEV. = ±100'-0" REF., ±101'-3" AGL ℄ OF EXISTING VERIZON ANTENNAS ELEV. = ±79'-0" REF., ±80'-3" AGL ℄ OF EXISTING ANTENNAS BY OTHERS ELEV. = ±96'-0" REF., ±97'-3" AGL ℄ OF EXISTING & PROPOSED VERIZON ANTENNAS ELEV. = ±78'-0" REF., ±79'-3" AGL TOP OF EXISTING ANTENNAS BY OTHERS ELEV. = ±100'-0" REF., ±101'-3" AGL TOP OF EXISTING VERIZON ANTENNAS ELEV. = ±82'-11" REF., ±84'-2" AGL TOP OF EXISTING VERIZON ANTENNAS ELEV. = ±81'-0" REF., ±82'-3" AGL EXISTING PANEL ANTENNAS BY OTHERS MOUNTED TO MONOPOLE, TYP. EXISTING & PROPOSED VERIZON CABLING ROUTED UP OUTSIDE OF MONOPOLE - SEE ANTENNA SCHEDULES ON SHEET A-4 EXISTING CROWN CASTLE MONOPOLE