CA-3_Elevations
INFINIGY
FROM ZERO TNFI O I NGY I
the solutions are endless
2 EXISTING WEST ELEVATION 0" 1 PROPOSED WEST ELEVATION
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' 8' 0"
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' 8'
NOTES:
x THESE DRAWINGS ARE NOT INTENDED TO BE A
VERIFICATION THAT THE STRUCTURE OR
MOUNTS ARE ADEQUATE TO SUPPORT THE
PROPOSED LOADING. VERIFICATION THAT THE
EXISTING STRUCTURE AND MOUNTS CAN
SUPPORT THE PROPOSED LOADING SHALL BE
PERFORMED BY A REGISTERED PROFESSIONAL
ENGINEER PRIOR TO CONSTRUCTION.
x CONTRACTOR TO REFER TO THE STRUCTURAL
ANALYSIS AND MOUNT ASSESSMENT AND
VERIFY LOADING WITH THE MOST RECENT RFDS
PRIOR TO CONSTRUCTION.
"LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT:
THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF
THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES
OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION,
MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS
SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF
THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING
FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE
LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE
ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY
TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT
TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS
INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING
EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO
YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO
GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR
NOTICE TICKET.
EXISTING PANEL ANTENNAS
BY OTHERS MOUNTED TO
MONOPOLE, TYP.
EXISTING ICE BRIDGE
BY OTHERS
EXISTING EQUIPMENT
CABINET BY OTHERS
EXISTING EQUIPMENT
SHELTER BY OTHERS
GRADE
ELEV. = 0'-0" AGL (±2662.0' AMSL)
℄ OF PROPOSED AT&T ANTENNAS
ELEV. = ±110'-0" REF., ±111'-3" AGL
TOP OF PROPOSED AT&T ANTENNAS
ELEV. = ±114'-0" REF., ±115'-3" AGL
BOTTOM OF TOWER STEEL
ELEV. = 0'-0" REF., 1'-3" AGL
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±79'-0" REF., ±80'-3" AGL
PROPOSED AT&T ANTENNAS WITH
ASSOCIATED EQUIPMENT MOUNTED TO
MONOPOLE - SEE SHEET A-4
PROPOSED AT&T
EQUIPMENT AT GROUND
- SEE SHEET A-2
EXISTING CROWN
CASTLE MONOPOLE
EXISTING
PLASTIC FENCE
TOP OF EXTENDED MONOPOLE
ELEV. = ±110'-0" REF., ±111'-3" AGL
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±96'-0" REF., ±97'-3" AGL
TOP OF EXISTING MONOPOLE
ELEV. = ±100'-0" REF., ±101'-3" AGL
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±79'-0" REF., ±80'-3" AGL
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±96'-0" REF., ±97'-3" AGL
EXISTING PANEL ANTENNAS
BY OTHERS MOUNTED TO
MONOPOLE, TYP.
EXISTING CROWN
CASTLE MONOPOLE
EXISTING
PLASTIC FENCE
PROPOSED 10'-0" MONOPOLE EXTENSION
EXISTING ICE BRIDGE
BY OTHERS
EXISTING EQUIPMENT
CABINET BY OTHERS
EXISTING EQUIPMENT
SHELTER BY OTHERS
GRADE
ELEV. = 0'-0" AGL (±2662.0' AMSL)
BOTTOM OF TOWER STEEL
ELEV. = 0'-0" REF., 1'-3" AGL
PROPOSED AT&T (1) FIBER CABLE
& (2) DC POWER CABLES ROUTED
UP MONOPOLE
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±78'-0" REF., ±79'-3" AGL
℄ OF EXISTING ANTENNAS BY OTHERS
ELEV. = ±78'-0" REF., ±79'-3" AGL