CA-3_Elevations
INFINIGY
1490 W. 121ST AVENUE, SUITE 101
WESTMINSTER, COLORADO 80234
ENGINEERING, PLLC
2 EXISTING SOUTH ELEVATION 4' 0" 4' 1 PROPOSED SOUTH ELEVATION
22"x34" SCALE: 3/16" = 1'-0"
11"x17" SCALE: 3/32" = 1'-0" 2' 4' 0" 4'
22"x34" SCALE: 3/16" = 1'-0"
11"x17" SCALE: 3/32" = 1'-0" 2'
EXISTING CROWN CASTLE
50'-0" MONOPOLE
EXISTING PANEL ANTENNAS
BY OTHERS MOUNTED TO
EXISTING MONOPOLE, TYP.
℄ OF EXISTING T-MOBILE ANTENNAS
ELEV. = ±50'-0"
TOP OF EXISTING MONOPOLE
ELEV. = ±50'-0"
TOP OF EXISTING T-MOBILE ANTENNAS
ELEV. = ±54'-0"
EXISTING T-MOBILE ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPOLE
TOP OF EXISTING MONOPOLE
ELEV. = ±50'-0" REF., ±50'-3" AGL
TOP OF PROPOSED T-MOBILE ANTENNAS
ELEV. = ±54'-0" REF., ±54'-3" AGL
PROPOSED T-MOBILE ANTENNAS
WITH ASSOCIATED EQUIPMENT
MOUNTED TO MONOPOLE
EXISTING CROWN CASTLE
50'-0" MONOPOLE
EXISTING AND PROPOSED
T-MOBILE CABLING
EXISTING T-MOBILE CABLING
NOTES:
x THESE DRAWINGS ARE NOT INTENDED TO BE A
VERIFICATION THAT THE STRUCTURE OR
MOUNTS ARE ADEQUATE TO SUPPORT THE
PROPOSED LOADING. VERIFICATION THAT THE
EXISTING STRUCTURE AND MOUNTS CAN
SUPPORT THE PROPOSED LOADING SHALL BE
PERFORMED BY A REGISTERED PROFESSIONAL
ENGINEER PRIOR TO CONSTRUCTION.
x CONTRACTOR TO REFER TO THE STRUCTURAL
ANALYSIS AND MOUNT ASSESSMENT AND
VERIFY LOADING WITH THE MOST RECENT RFDS
PRIOR TO CONSTRUCTION.
"LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT:
THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF
THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES
OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION,
MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS
SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF
THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING
FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE
LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE
ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY
TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT
TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS
INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING
EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO
YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO
GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR
NOTICE TICKET.
GRADE
ELEV. = 0'-0" AGL (±2608.3' AMSL)
℄ OF PROPOSED T-MOBILE ANTENNAS
ELEV. = ±50'-0" EXISTING T-MOBILE ANTENNAS
WITH ASSOCIATED EQUIPMENT
TO BE RELOCATED
GRADE
ELEV. = 0'-0" AGL (±2608.3' AMSL)
2
A-4
1
A-4
1
A-4
EXISTING PANEL ANTENNAS
BY OTHERS MOUNTED TO
EXISTING MONOPOLE, TYP.
2
A-4
1
A-4