Amity CZC Package_2.21.2019Planning Division
CERTIFICATE OF ZONING COMPLIANCE
Application Checklist
Community Development Planning Division 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642
Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning
(09/14/2018)
Project name: "Amity" Horizon Tower new unmanned wireless telecommunications monopine facility File #:
Applicant/agent: Zachary Williams. Powder River Development Services, LLC
All applications are required to contain one copy of the following unless otherwise noted:
Applicant
()
Description
Staff
()
Completed and signed Development Review Application
Narrative fully describing the proposed use of the property, including the following:
Information on any previous approvals or requirements for the requested use (i.e.,
applicable conditions of approval or Development Agreement)
Recorded warranty deed for the subject property
Affidavit of Legal Interest signed and notarized by the property owner (If owner is a corporation,
submit a copy of the Articles of Incorporation or other evidence to show that the person signing is an authorized agent)
Scaled vicinity map showing the location of the subject property
Stamped site plan from Republic Services approving the details and location of the trash
enclosure and access drive. Contact Richard Scott at rscott3@republicservices.com or by
phone 208-685-7729
Civil Site/Dimension Plan – 1 full size copy (folded to 8 ½” x 11” size)
A photometric test report for any light fixture(s) with a maximum output of 1,800 lumens
or more (see UDC 11-3A-11)
Copy of the recorded plat the property lies within (8 ½” x 11”)
Copy of address verification letter from Development Services. See attached request form
Site Plan—*1 copy (folded to 8 ½” x 11” size)
Plan must have a scale no smaller than 1” = 50’ (1” = 20’ is preferred) and be on a standard
drawing sheet, not to exceed 36” x 48” (24” x 36” is preferred). A plan which cannot be drawn in
its entirety on a single sheet must be drawn with appropriate match lines on two or more sheets
The following items must be shown on the site plan:
Date, scale, dimensions, north arrow, and project name (scale not less than 1”=50’)
Names, addresses, and telephone numbers of the developer and the person and/or
firm preparing the plan
Parking stalls and drive aisles
Location and detail of bicycle parking facilities
Trash and/or recycling enclosure(s) location
Detail of trash and/or recycling enclosure (must be screened on 3 sides)
Location and specifications for underground irrigation (Pressurized irrigation can only be
waived if you prove no water rights exist to subject property)
Sidewalks or pathways (proposed and existing)
Location of proposed building on lot (include dimensions to property lines)
Fencing (proposed and existing)
Calculations table including the following:
Number of parking stalls required and provided (specify handicap and compact stalls)
Number of bicycle stalls required and provided
Building size (sq. ft.)
Lot size (sq. ft.)
Setbacks
Easement locations
Reduction of the site plan (8 ½” x 11”)
Landscape Plan – *1 copy (folded to 8 ½” x 11” size)
Plan must have a scale no smaller than 1” = 50’ (1” = 20’ is preferred) and be on a standard
X
X
X
Community Development Planning Division 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642
Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning
drawing sheet, not to exceed 36” x 48” (24” x 36” is preferred). A plan which cannot be drawn in
its entirety on a single sheet must be drawn with appropriate match lines on two or more sheets
The following items must be included on the landscape plan:
Date, scale, dimensions, north arrow, and project name
Names, addresses, and telephone numbers of the developer and the person and/or
firm preparing the plan
Stamp/signature of a landscape architect, landscape designer, or qualified
nurseryman preparing the plan
Existing natural features such as canals, creeks, drains, ponds, wetlands,
floodplains, high groundwater areas, and rock outcroppings
Location, size, and species of all existing trees on site with trunks 4 inches or
greater in diameter, measured 6 inches above the ground. Indicate whether the
tree will be retained or removed
A statement of how existing healthy trees proposed to be retained will be
protected from damage during construction
Existing and/or structures, planting areas, light poles, power poles, walls, fences,
berms, parking and loading areas, vehicular drives, trash areas, sidewalks,
pathways, fire hydrants, stormwater detention areas, signs, street furniture, and
other man-made elements
Existing and proposed contours for all areas steeper than 20% slope. Berms shall
be shown with one-foot contours
Sight Triangles as defined in 11-3A-3 of this ordinance
Location and labels for all proposed plants, including trees, shrubs, and
groundcovers (trees must not be planted in City water or sewer easements or within five feet of fire
hydrants). Scale shown for plant materials shall reflect approximate mature size
A plant list that shows the plant symbol, quantity, botanical name, common name,
minimum planting size and container, tree class (I, II, or III), and comments (for
spacing, staking, and installation as appropriate)
Calculations of project components to demonstrate compliance with the
requirements of this ordinance, including:
Width of street buffers, lineal feet of street frontage, and number of street trees
Residential subdivision trees
Acreage and percentage dedicated for common open space
Acreage and percentage dedicated for qualified open space
Number of trees provided on common lot(s)
Mitigation for removal of existing trees
Planting and installation details as necessary to ensure conformance with all
required standards
Design drawing(s) of all fencing proposed for screening purposes. Include height
and material
Reduction of the landscape plan (8 ½” x 11”)
Building elevations showing construction materials – *1 copy (folded to 8 ½” x 11” size)
Reduction of the elevations (8 ½” x 11”)
Electronic version of the site plan, landscape plan, and building elevations in pdf format
submitted on a disk with the files named with project name and plan type (i.e. site plan,
landscape plan, elevations, etc.). We encourage you to submit at least one color version
If applying for approval of a public school, provide additional information as required by
the Public School Facility supplemental checklist per §67-6519
Fee (If this project had prior approval on a site plan, reduced fees may apply)
For applications requiring a change of use or new construction we recommend you contact
the Ada County Highway District at (208) 387-6170 to determine any fees or requirements
For new public utility construction (water, sewer, reclaimed water) applicants are required to submit:
(2) Sets of conceptual engineering plans including pipe sizes and profiles, in a format that
complies with the specifications for project Drawings found at:
N/A www.meridiancity.org/public_works/autocad_standards/index.asp
X
X
N/A Unmanned
X
N/A unmanned
X
X
X
X
X
N/A Unmanned
N/A Unmanned
N/A Unmanned
N/A Unmanned
N/A
N/A
X
X
X
X
N/A
Site Name/#: AMITY - ID4301 AUTHORIZATION
The undersigned is the "Owner" of the real property ("Property") described below, and hereby
authorizes, consents and agrees with Horizon Tower Limited Partnership-II, a Kansas Limited
Partnership, by Horizon Tower, LLC, its Operations Partner ("Horizon"), as follows:
1. Entry. Owner consents and agrees that Horizon, its employees, agents and
independent contractors ("Authorized Parties") may enter upon the Property to
conduct and perform some of all of the following activities ("Permitted Activities"):
Surveys, geotechnical soil borings and analysis, phase I environmental audits,
boundary surveys, radio propagation studies, and such other tests and inspections of
the Property which Horizon, may deem necessary or advisable. Horizon agrees to be
responsible for any and all costs related to the Permitted Activities, including
installation on and operation and removal of equipment on the Property. Horizon
agrees to indemnify, save harmless and defend Owner, its directors, officers,
employees and agents from and against any and all claims, actions, damages, liability
and expense in connection with personal injury and/or damage to property arising
from or out of any occurrence in, upon or at the Property caused by any act or
omission of the Authorized Parties in conducting the Permitted Activities.
2. Filings. Owner consents and agrees that the Authorized Parties may make and file
applications on Owner's behalf of such local, state and federal governmental entities
whose approval Horizon may consider necessary or advisable to have the Property
approved as a tower or antenna site, including, but not limited to, governmental
approval for zoning variances, rezoning applications, building permits, and wetland
permits. Owner hereby agrees that a copy of this Agreement is as effective as the
original. However, if requested by the Authorized Parties, Owner agrees to execute
such other and further documents as may be required by the governmental entity in
question to evidence Owner's consent to the action which is proposed to be taken.
Owner: Hill & Hill Properties LP, an Idaho limited partnership
Date: J\Wj VI '2Dlg
Property address: Amity Road and Eagle Road, Meridian, Ada County, Idaho
Community Development Planning Division 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642
Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning
Meridian Development Services
Address Verification Request
Requestor
Name Phone
Address
Email
Please check the appropriate box below and submit the required information to
communitydevelopment@meridiancity.org. Please allow one business day for reply.
Commercial Project
Required Information:
Project Name
Address (if known)
Lot _______ Block _______ Subdivision
Site Plan - Include adjacent street name(s)
Detailed Floor Plan to include:
Entrances – Designate “main entrance” if occupying more than one space
Proposed number of tenants and spaces – Define clearly on plan
CO/Tenant Improvement Project
Required Information:
Project Name
Address (including suite number)
Lot _______ Block _______ Subdivision
Detailed Floor Plan to include:
Entrances – Designate “main entrance” if occupying more than one space
Proposed number of tenants and spaces – Define clearly on plan
Sign Permit Application
Required Information:
Project Name
Building Permit#
Address (including suite number)
Lot _______ Block _______ Subdivision
Zachary Willilams - Powder River Development Services , LLC 208-963-4026
408 S. Eagle Rd. Suite 200. Eagle, ID. 83616
Zachary.williams@powderriverdev.com
"Amity" Horizon Tower new unmanned wireless telecommunications monopine facility
No Situs. Parcel: S1133223010. Southeast corner of S. Eagle Rd and E. Amity Rd.
N/A N/A 3N 1E 33
Planning Division
DEVELOPMENT REVIEW APPLICATION
Community Development Planning Division 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642
Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning
-1 Rev:(2/2/20182/7/2018)
STAFF USE ONLY:
Project name:
File number(s):
Assigned Planner: Related files:
Type of Review Requested (check all that apply)
Accessory Use (check only 1)
Daycare
Home Occupation
Home Occupation/Instruction for 7 or more
Administrative Design Review
Alternative Compliance
Annexation and Zoning
Certificate of Zoning Compliance
City Council Review
Comprehensive Plan Map Amendment
Comprehensive Plan Text Amendment
Conditional Use Permit
Conditional Use Modification (check only 1)
Director
Commission
Development Agreement Modification
Final Plat
Final Plat Modification
Landscape Plan Modification
Preliminary Plat
Private Street
Property Boundary Adjustment
Rezone
Short Plat
Time Extension (check only 1)
Director
Commission
UDC Text Amendment
Vacation (check only 1)
Director
Commission
Variance
Other
Applicant Information
Applicant name: Phone:
Applicant address: Email:
City: State: Zip:
Applicant’s interest in property: Own Rent Optioned Other
Owner name: Phone:
Owner address: Email:
City: State: Zip:
Agent/Contact name (e.g., architect, engineer, developer, representative):
Firm name: Phone:
Agent address: Email:
City: State: Zip:
Primary contact is: Applicant Owner Agent/Contact
Subject Property Information
Location/street address: Township, range, section:
Assessor’s parcel number(s): __________________________ Total acreage: Zoning district:
X
Community Development Planning Division 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642
Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning
-2- Rev:(2/7/2018)
Project/subdivision name:
General description of proposed project/request:
Proposed zoning district(s):
Acres of each zone proposed:
Type of use proposed (check all that apply):
Residential Office Commercial Employment Industrial Other
Who will own & maintain the pressurized irrigation system in this development?
Which irrigation district does this property lie within?
Primary irrigation source: Secondary:
Square footage of landscaped areas to be irrigated (if primary or secondary point of connection is City water):
Residential Project Summary (if applicable)
Number of residential units: Number of building lots:
Number of common lots: Number of other lots:
Proposed number of dwelling units (for multi-family developments only):
1 bedroom: 2–3 bedrooms: 4 or more bedrooms:
Minimum square footage of structure (excl. garage): Maximum building height:
Minimum property size (s.f): Average property size (s.f.):
Gross density (Per UDC 11-1A-1): Net density (Per UDC 11-1A-1):
Acreage of qualified open space: __________________ Percentage of qualified open space: __________________
Type and calculations of qualified open space provided in acres (Per UDC 11-3G-3B):
Amenities provided with this development (if applicable):
Type of dwelling(s) proposed: Single-family Detached Single-family Attached Townhouse
Duplex Multi-family Vertically Integrated Other ____________________________________
Non-residential Project Summary (if applicable)
Number of building lots: Common lots: Other lots:
Gross floor area proposed: Existing (if applicable):
Hours of operation (days and hours): Building height:
Total number of parking spaces provided: Number of compact spaces provided:
Authorization
Print applicant name:
Applicant signature: Date:
X Wireless telecommunications facility
N/A. Unmanned facility
3N 1E 33
Construction of a new wireless telecommunications facility.
Scope of Work includes 100' stealth monopine with a fenced 20' X 70' lease area.
none
N/A
1
none
N/A unmanned occupancy 100' monopine
N/A unmanned N/A
lease area 1400 sf
Zachary Williams
2/20/2019
No change
Powder River Development Services, LLC on behalf of Horizon Tower and Verizon 208-963-4026
408 S Eagle Rd, Ste 200 zachary.williams@powderriverdev.com
Eagle ID 83616
X Construction of a wireless telecom facility
X
Horizon Tower / Verizon Wireless c/o Powder River Development Services, LLC
Zachary Williams - Authorized Agent
208-963-4026
408 S Eagle Rd, Ste 200 Zachary.Williams@powderriverdev.com
Eagle ID 83616
Marti Hill & David Turnbill
No Situs. On SE Corner of Amity and Eagle Rd
S1133223010
208-378-4000
39.71 R-8
3N 1E 33
12601 W Explorer, Ste 200 dturnbill@brightoncorp.com
Boise ID 83713
Narrative
Conditional Use Application for Horizon Tower
‘Amity’ Monopine Wireless Communication
Facility
A Proposal Submitted to the City of Meridian
Prepared for:
Horizon Tower
Verizon Wireless
Prepared by:
408 S Eagle Rd, Ste. 200
Eagle, ID 83616
February 20, 2019
Contents
Description of Project ......................................................................................................... 2
Description of current and proposed uses ........................................................................... 2
Response to 11-4-3-43: Wireless Communication Facilities Approval Criteria ................ 2
Response to 11-5B-6: Conditional Uses: ............................................................................ 8
Conclusion ........................................................................................................................ 12
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
2
Description of Project
With the Treasure Valley being one of the fastest growing regions in the US, there has
been an increased network demand for cellular service. As illustrated in the enclosed
drawings, the proposed 100’ monopine will support panel antennas, and new ground
mounted equipment will be located within a fenced enclosure. Additional space on the
monopine is available to accommodate additional wireless carriers as needed for future
collocation opportunities. The new wireless facility will add to Verizon Wireless’ existing
network and provide improved services to customers and improved calling/data
capacity, thereby improving overall system performance. Verizon Wireless and Horizon
Tower is committed to providing the latest in quality wireless services to the City of
Meridian and the surrounding area for years to come.
Description of current and proposed uses
The proposed location of this development in the R‐8 (Medium‐density residential
district) zoning district, is allowed with a Conditional Use Permit (Title 11‐4‐3‐43 C. 5. a.
City of Meridian Unified Development Code Chapter 4 Specific Use Standards). The
proposed facility will be located near the corner southeast of S. Eagle Road and Amity
Road, on a lot shared with a single‐family residence and farm field. Because
maintenance visits occur approximately once a month, there will be virtually no
transportation impact to the surrounding area.
Response to 11‐4‐3‐43: Wireless Communication Facilities Approval
Criteria
All responses by Powder River Development Services (applicant) are in bold.
11-4-3-43: WIRELESS COMMUNICATION FACILITY:
A. Purpose: The purpose of this section is to accommodate the communications needs of the city of
Meridian's residents and businesses while at the same time protecting the safety, aesthetic appeal
and general welfare of the community. Furthermore, it is the purpose of this section to regulate
the impact of communication towers within the city limits and to provide for the wireless
communication needs of the public.
The intent of this section is to:
1. Facilitate the provision of wireless telecommunication services to the residents and businesses
of the city of Meridian.
2. Minimize the adverse visual effects of communication towers and other similar structures
through careful design standards.
3. Avoid potential damage to adjacent properties from the structural failure of towers and other
such structures through structural standards and setback requirements.
4. Require the collocation of new wireless communication equipment, when possible, in order to
reduce the number of towers required to serve the city.
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
3
5. Encourage the location of wireless communication facilities in nonresidential districts and/or
districts where nonresidential uses are allowed.
6. Encourage the construction of stealth communication towers which are compatible with their
surroundings and do not detract from the overall visual quality of the city.
B. Applicability: The following provisions shall apply to any construction, installation, addition to or
increase in the height of any wireless communication tower.
C. Process: The process for wireless communication facilities is dependent upon standards as set forth
in this section and the district in which the facility is located.
1. All proposed communication towers shall be designed (structurally and electrically) to
accommodate the applicant's antennas as well as collocation for at least one additional user.
Response: The 100’ monopine will accommodate future collocations for multiple
carriers using a stealth design.
2. A proposal for a new commercial communication tower shall not be approved unless the
decision making body finds that the telecommunications equipment planned for the proposed
tower cannot be accommodated on an existing or approved structure and/or tower.
Response: Based on the design criteria for selecting wireless facilities, Verizon
Wireless’ radio frequency engineers first develop a “Search Area” that identifies the
geographic area where the site must be located in order to provide additional network
capacity service. The location of the search area is based on radio frequency coverage
objectives including, usage patterns, topography and other technical factors. There are
no existing towers or structures within the geographic area capable of meeting the
proposed facility’s requirements.
The search area size is very important to maintain adequate separation from Verizon
Wireless’ existing sites in their network. There is very little flexibility for the location
of new facilities in the network because of the very low powered transmitters, which
cover a relatively small geographic area, and the limitations of locating within Verizon
Wireless’ existing dense urban network of sites. The location of the search area is
based on radio frequency coverage objectives, usage patterns, the location of adjacent
Verizon Wireless facilities, topography and other technical factors.
The Propagation Study maps in conjunction with the ‘Location in Relation to Existing
Sites’ map illustrate the geographic area where the proposed site must be located to
provide its service. Due to the close proximity of existing Verizon Wireless sites to the
north, south, east, and west, the proposed site would interfere with one or more of
Verizon Wireless’ neighboring sites, and leave a gap in service if it were located
outside of the search area. Interference could result in poor network quality, dropped
calls, coverage gaps, fast busy signal and inability to initiate calls or access data. The
proposed site location has been identified within the prescribed search area. As stated
in the enclosed Propagation Maps, Verizon Wireless needs a new wireless
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
4
communication facility at this location to improve network capacity and offload
demand from their existing network serving the area.
3. It shall be the burden of the applicant to demonstrate the proposed tower or antenna cannot be
accommodated on an existing or approved tower or structure. One or more of the following
documentation shall be provided as proof that the new tower is necessary:
Response: See enclosed ‘Amity Cell Tower: Location in Relation to Existing Sites’ map
demonstrating no other existing cell towers within 1 mile are suitable to
accommodate the needed equipment to provide coverage. Again, there are no
existing towers or structures within the geographic area capable of meeting the
proposed facility’s requirements.
a. Unwillingness of other tower or facility owners to entertain shared use.
Response: No viable existing towers in area to accommodate a collocation of
equipment.
b. The proposed collocation of an existing tower or facility would be in violation of any state or
federal law.
Response: No viable existing towers in area to accommodate a collocation of
equipment.
c. The planned equipment would exceed the structural capacity of existing towers, as
documented by a qualified and licensed structural engineer.
Response: No viable existing towers in area to accommodate a collocation of
equipment.
d. The planned equipment would cause interference, materially impacting the usability of other
existing or planned equipment on the tower as documented by a qualified and licensed
engineer.
Response: No viable existing towers in area to accommodate a collocation of
equipment.
e. Existing or approved towers cannot accommodate the planned equipment at a height necessary
to function reasonably as documented by a qualified radio frequency engineer.
Response: No viable existing towers in area to accommodate a collocation of
equipment.
4. N/A. New tower build.
5. Stealth tower facilities shall meet the following standards:
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
5
a. Stealth towers in residential districts with allowed nonresidential uses shall require conditional
use permit approval. In all other districts, stealth towers shall be deemed a principally
permitted use and shall require a certificate of zoning compliance prior to installation.
Response: The property for the proposed stealth monopine WCF is zoned R‐8.
b. Facilities shall meet the setbacks of the zoning district, except for facilities on a property
abutting a residential use or a public right of way shall be set back a distance equal to the
height of the tower.
Response: Immediately north is a parcel for the Idaho Power electric substation. There
are single‐family residences to the south of the subject parcel. There will be future
single‐family properties zoned residential to the North across the street of Amity
Road. The monopine tower will be a total height of 100’. The tower will be setback
approximately 911’ from the neighboring residential properties to the south.
c. Any facilities not meeting these standards shall require approval of a conditional use permit, in
addition to any other necessary permits.
Response: The facility proposed exceeds the stealth tower facility standards set forth
by the City of Meridian. Therefore, a Conditional Use Permit is required.
6 - 10. N/A
D. Required Documentation: The applicant shall provide the following documentation with the request
for approval of a wireless communication facility:
1. For all wireless communication facilities, a letter of intent committing the tower owner and his, her
or its successors to allow the shared use of the tower, as required by this section, if an additional
user agrees in writing to meet reasonable terms and conditions for shared use.
Response: Letter of Intent attached with this application.
2. Propagation charts showing existing and proposed transmission coverage at the subject site and
within an area large enough to provide an understanding of why the facility needs to be in the
chosen location.
Response: Propagation charts and RF study attached to application.
3. A statement regarding compliance with regulations administered and enforced by the federal
communications commission (FCC) and/or the federal aviation administration (FAA).
Response: FCC /FAA compliance letter attached.
E. Design Standards: All new communications towers shall meet the following minimum design
standards:
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
6
1. All towers shall be designed to be architecturally compatible with the surrounding buildings and
land uses in the zoning district, or otherwise integrated to blend in with existing characteristics of
the site.
Response: Many design amenities will be included into the design to promote the
appearance of the proposed facility and help blend the tower facility to the natural
and built environment. Although visible, the monopine is a passive object in a large
viewshed. In an effort to limit visual impacts, Horizon Tower has selected a site which
will be located within a future storage facility. The stealth nature on the monopine
design is the most appropriate design at this location. The monopine will blend in with
the existing vegetation in the area. Additionally, by locating the facility with a setback
of approximately 150 feet from South Eagle Road, potential views of the monopine
will be less significant because the monopine occupies a smaller portion of the view.
Where visible, the significance of views of the facility will vary inversely with distance
from the site. That is, the farther away the viewer, the less significant the monopine,
because it occupies a smaller portion of the person’s view as that person moves
farther from the site. The proposed monopine design utilizes a low profile design to
achieve the height requirements of the proposed facility. The monopine has slim
silhouette and footprint compared to more massive alternates, such as a lattice
towers with their many cross members and large footprint, and guy towers with their
many guy wires radiating out from the tower. When viewed from the surrounding
areas, the proposed monopine will blend with the surrounding vegetation.
2. The facility shall be painted a neutral, nonreflective color that will blend with the surrounding
landscape. Recommended shades are gray, beige, sand, taupe, or light brown. All metal shall be
corrosive resistant or treated to prevent corrosion.
Response: The proposed monopine structure will be stealth in design and blend in
with existing vegetation in the area, greatly reducing visual impact.
3. All new communication tower facilities shall be of stealth or monopole design, unless the decision
making body determines that an alternative design would be appropriate because of location or
necessity.
Response: Stealth monopine proposed.
4. No part of any antenna, disk, array or other such item attached to a communications tower shall be
permitted to overhang any part of the right of way or property line.
Response: All ground equipment and structures of the WCF will be contained in a 20’ X
70’ lease area served by an access/utility easement
5. The facility shall not be allowed within any required street landscape buffer.
Response: The proposed project is in a farm field to the rear of an existing electric
distribution center.
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
7
6. All new communication tower facility structures require administrative design review approval, in
addition to any other necessary permits. Structures contained within an underground vault are
exempt from this standard.
Response: Design Review Checklist, Architectural Standards Design Review Checklist
included.
7. Any equipment at ground level shall be screened by a sight obscuring fence or structure.
Response: The proposed compound will be screened by a fence.
8. All tower facilities shall include a landscape buffer. The buffer shall consist of a landscape strip of
at least five feet (5') wide outside the perimeter of the compound. A minimum of fifty percent
(50%) of the plant material shall be of an evergreen variety. In locations where the visual impact of
the tower is minimal, the applicant may request a reduction to these standards through the
alternative compliance process in accord with chapter 5, "Administration", of this title.
Response: There is currently a 35’ wide landscape buffer immediately north of the
proposed cell tower project site for the existing Idaho Power electric substation.
Landscape buffers to the east and west sides of the compound will not be necessary as
a future storage facility is proposed surrounding the project site. A buffer on the south
side of the project site is not feasible as this needs to be open for easement access for
maintenance visits.
9. All climbing pegs within the bottom twenty feet (20') of the tower shall be removed except when
the tower is being serviced.
Response: The tower is stealth design to resemble a pine tree and will not have
climbing pegs exposed within the bottom 20’ of the tower.
F. Abandoned Or Unused Towers Or Portions Of Towers: All abandoned or unused towers and
associated facilities shall be required to be removed within sixty (60) days of cessation of use as a
wireless communication facility, unless a time extension is granted by the City Council. A copy of
the relevant portions of a signed lease, which requires the applicant to remove the tower and
associated facilities upon cessation of the use as a wireless communication facility, shall be
submitted at the time of application and resubmitted upon renewal or termination. In the event that
the tower and associated facilities are not removed within the sixty (60) days, the tower and
associated facilities may be removed by the City and the costs of removal assessed against the real
property.
Response: Upon expiration or termination hereof, Lessee shall restore the Premises to
the condition in which it existed upon execution hereof, reasonable wear and tear and
loss by casualty or other causes beyond Lessee’s control excepted.
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
8
Response to 11‐5B‐6: Conditional Uses:
A. Purpose: The purpose of this section is to establish procedures that allow for a particular
use on a particular property subject to specific terms and conditions of approval. (Ord.
05-1170, 8-30-2005, eff. 9-15-2005)
B. Applicability: The provisions of this section shall apply to:
Response: Refer to Title 11‐4‐3‐43 C. 5. a.: City of Meridian Unified Development Code
Chapter 4 Specific Use Standards a. Stealth towers in residential districts with allowed
nonresidential uses shall require conditional use permit approval.
C. Process:
1. The applicant shall complete a preapplication conference with the Director prior to submittal
of an application for a conditional use.
Response: A pre‐application meeting was held on June 8, 2018.
2. An application and fees, in accord with article A, "General Provisions", of this chapter, shall
be submitted to the Director on forms provided by the Planning Department.
Response: CUP fees in the amount of $1,369 included.
3. The Director may require additional information concerning the social, economic, fiscal or
environmental effects of the proposed conditional use.
Response: The information provided in this application addresses the social,
economic, fiscal and environmental effects of the proposed conditional use. The
wireless telecommunications facility will provide greater wireless coverage to
residents, providing a necessary, reliable social service that users depend upon for
communication. A majority of households no longer possess a landline for telephone
services and rely on cellular service for 911 services and communication with family
and friends. Reliable cellular coverage used for voice and data services is obligatory
for the City of Meridian’s economic business activities. Fiscally, the City of Meridian is
not required to provide many services to serve the use of the compound, as the
facility is unmanned. Telco, fiber and power are the only services required. There will
be no adverse environmental effects associated with the proposed project. There are
no activities associated with the site that will produce odor, vibration, heat, glare,
radioactive materials, or noxious and toxic material. All equipment and materials
needed to operate the site will be located within the proposed fenced area at the base
of the existing support structure. Since the facility does not have water or sanitary
facilities it will generate no wastewater. An insignificant amount of vehicle trips will
be generated from the establishment of the use since the only visits required are for
monthly maintenance.
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
9
D. Standards: In approving any conditional use, the decision making body may prescribe
appropriate conditions, bonds and safeguards in conformity with this title that:
1. Minimize adverse impact of the use on other property.
Response: The wireless telecommunication facility use will not adversely impact the
electric substation facility run by Idaho Power immediately north of the project site.
The future storage facility use that will eventually surround the project site will be
compatible with the cell tower. The stealth monopine design of the cell tower will
reduce the visual impact on the surrounding residential and future residential
properties in the neighborhood.
2. Control the sequence and timing of the use.
Response: The wireless telecommunication facility is an unmanned use. The only times
the facility will generate trips are for monthly and sporadic maintenance visits.
Therefore, no controls for the sequence or timing of use are necessary for this
application.
3. Control the duration of the use.
Response: In accordance with 11‐4‐3‐43: F. Abandoned Or Unused Towers Or Portions
Of Towers – it is agreed that the facility will be removed within 60 days upon cessation
of use. Upon expiration or termination hereof, Lessee shall restore the Premises to the
condition in which it existed upon execution hereof, reasonable wear and tear and
loss by casualty or other causes beyond Lessee’s control excepted.
4. Assure that the use and the property in which the use is located is maintained properly.
Response: The lease agreement with the property owner ensures the facility will be
maintained to ensure compliance with City of Meridian property code regulations.
5. Designate the exact location and nature of the use and the property development.
Response: The site plan and survey included with this application specify the exact
location and legal description where the project will be constructed.
6. Require the provision for on site or off site public facilities or services.
Response: The use of the wireless telecommunications facility is unmanned.
Therefore, no additional facilities other than telco, fiber and power are required to be
included in the site plan.
7. Require more restrictive standards than those generally required in this title.
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
10
Response: The provisions set forth in Title 11‐4‐3‐43 will be more than sufficient to
ensure the wireless telecommunications facility blends with the surrounding
neighborhood and provides wireless coverage with the least amount of visual impact
using a stealth monopine design.
8. Require mitigation of adverse impacts of the proposed development upon service delivery by
any political subdivision, including school districts, that provides services within the city.
Response: The unmanned occupancy of the facility will not adversely impact the
service delivery of political subdivisions, such as school districts, that provide services
within the city.
E. Findings: The commission shall base its determination on the conditional use permit
request upon the following:
1. That the site is large enough to accommodate the proposed use and meet all the
dimensional and development regulations in the district in which the use is located.
Response: The compound plan includes ground equipment space for (4) carriers within
the proposed compound area to allow for collocation. Furthermore, the 100’
monopine has room for (4) antenna arrays. Verizon will be the first of several carriers
to collocate on the tower. Collocation helps reduce the visual impact of cell towers as
one facility can house multiple wireless tenants versus having multiple towers for
individual carriers in one neighborhood or small geographic area. The tower will easily
accommodate collocations using a stealth design to ensure reduction of adverse visual
impacts in the neighborhood.
2. That the proposed use will be harmonious with the Meridian comprehensive plan and in
accord with the requirements of this title.
Response: The proposed wireless communication tower facility is not in conflict with
the comprehensive plan, and will support the balanced development of the
surrounding area with reliable wireless services. Furthermore, the stealth monopine
design will fit the aesthetics of the residential character of the neighborhood.
3. That the design, construction, operation and maintenance will be compatible with other uses
in the general neighborhood and with the existing or intended character of the general
vicinity and that such use will not adversely change the essential character of the same area.
Response: The proposed wireless communications facility is appropriate to the
location and compatible with the uses permitted in the zoning district. As
demonstrated on the ‘Amity Cell Tower: Location in Relation to Existing Sites’ Map,
the proposed cell tower is strategically located no less than 1 mile from existing cell
towers in the area. The subject property is large enough to accommodate the use, and
the passive, unoccupied use typically only generates an average of one vehicle trip a
month for maintenance, much less than other uses allowed in the R‐8 zone. Its only
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
11
interaction with other uses in the area is providing reliable wireless
telecommunication services to customers in the area.
4. That the proposed use, if it complies with all conditions of the approval imposed, will not
adversely affect other property in the vicinity.
Response: the proposed wireless telecommunications facility will be immediately
adjacent to an existing Idaho Power electrical substation and a future storage facility.
These uses are perfectly suited to compliment the proposed wireless
telecommunications facility. Furthermore, the stealth monopine will blend in with the
existing vegetation and be visually pleasing when viewed from the existing and future
residential properties in the area.
5. That the proposed use will be served adequately by essential public facilities and services
such as highways, streets, schools, parks, police and fire protection, drainage structures,
refuse disposal, water, and sewer.
Response: The use of the wireless telecommunications facility is unmanned.
Therefore, no additional facilities other than telco, fiber and power are required. The
access driveway will accommodate fire trucks in the event of an emergency.
6. That the proposed use will not create excessive additional costs for public facilities and
services and will not be detrimental to the economic welfare of the community.
Response: The unmanned occupancy will not create excessive additional costs for
public facilities and services. The wireless telecommunications facility will not be
detrimental to the economic welfare of the community. The stealth monopine design
will not negatively impact the residential values of homes in the area.
7. That the proposed use will not involve activities or processes, materials, equipment and
conditions of operation that will be detrimental to any persons, property or the general
welfare by reason of excessive production of traffic, noise, smoke, fumes, glare or odors.
Response: There are no activities associated with the site that will produce odor,
vibration, heat, glare, radioactive materials, or noxious and toxic material. All
equipment and materials needed to operate the site will be located within the
proposed fenced area at the base of the existing support structure. Since the facility
does not have water or sanitary facilities it will generate no wastewater. The
unmanned occupancy will generate a very limited amount of vehicle trips for
maintenance, much less so than any other R‐8 zoning district uses.
8. That the proposed use will not result in the destruction, loss or damage of a natural, scenic
or historic feature considered to be of major importance. (Ord. 05-1170, 8-30-2005, eff. 9-15-
2005)
Horizon Tower – Amity Wireless Communications Facility Monopine
Conditional Use Permit Application
12
Response: The stealth monopine will blend in with the natural and scenic views in the
area.
9. Additional findings for the alteration or extension of a nonconforming use:
N/A
Conclusion
Considering the foregoing analysis and findings, the applicant requests approval of this
proposed Conditional Use Permit application. The application meets all applicable
criteria for approval.
TITLE SHEET
DRIVING DIRECTIONS
VICINITY MAP SITE PHOTO
N
APPLICABLE CODES
SCOPE OF WORK
SITE
DRAWING INDEX
100' MONOPINE
NEW SITE BUILD
APPROVALS
HORIZON SITE NAME:
AMITY
ID4301
LOCATION:
S EAGLE RD
MERIDIAN, ID 83642
HORIZON SITE NAME:
AMITY
ID4301
S EAGLE RD
MERIDIAN, ID
83642
T-1
SITE INFORMATION
CONTACT INFORMATION
HORIZON SITE NAME:
AMITY
ID4301
S EAGLE RD
MERIDIAN, ID
83642
Z-1
SITE PLAN
OVERALL SITE PLAN SCALE: 1" = 60' (11x17) 1
N
HORIZON SITE NAME:
AMITY
ID4301
S EAGLE RD
MERIDIAN, ID
83642
COMPOUND PLAN Z-2
COMPOUND
PLAN
SCALE: 1/8" = 1'-0" (11x17) 1
N
HORIZON SITE NAME:
AMITY
ID4301
S EAGLE RD
MERIDIAN, ID
83642
Z-3
ELEVATIONS
PROPOSED ELEVATION SCALE: 1/16" = 1'-0" (11x17) 2 PROPOSED ANTENNA PLAN SCALE: 3/16" = 1'-0" (11x17) 1