BUILDING 8S 88°58'53" E 102.38' S 00°00'00" E 365.13' N 00°00'00" E S 89°01'30" W 215.01' N 89°56'11" E 112.62' 370.49' LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 24 LOT 25 COMMON LOT 23 COMMON LOT 9 27.00' 5.00' 20.68' 9.63' NE 4TH STREET E. BADLEY AVENUE S 00°00'00" E 365.13' 57.76' 29.05' 104.00' 20.00' 84.00' LOT 15 193.28' 3'-0" 3'-0" 40'-0" 12'-0" 12'-0" A/C UNIT GAS A/C UNIT GAS POWER METER POWER METER A/C UNIT BUILDING 8 GRASS S H E A R W A L L S C H E D U L E SW1 7/16" APA RATED w/ 8d @ 6" & 12" O.C. CEILING FAN (WITH LIGHT AS INDICATED) L E G E N D T.K. 2-1/2x12 TOE KICK REGISTER DUPLEX OUTLET SWITCH 40" A.F.F. (UNLESS NOTED OTHERWISE) 220 VOLT OUTLET 4x10 FLOOR VENT LIGHT FIXTURE WALL SCONCE RECESSED CAN LIGHT FIXTURE FLOOR LIGHT/ STAIR LIGHT SMOKE DETECTOR EXHAUST FAN: 100 CFM INTERMITTENT - KITCHENS CARBON MONOXIDE DETECTOR NOTE: A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS 50 CFM INTERMITTENT - BATHROOMS/UTIILTY SAFETY GLAZING. WITH FRAMER BEFORE CONSTRUCTION. 11. CONTRACTOR TO VERIFY WINDOW HEIGHTS 6. PROVIDE 1/2 " MOISTURE PROOF GYPSUM BOARD OF 18" A.F.F. 4" CONC. SLAB CONC. SHOP FLOOR SLOPE EXP. JOINTS AS REQ'D SLOPE TO DRAIN ON 4" COMPACTED GRAVEL BASE @ 1/4" PER FT. BLOCK OUT FOR 16'-0" O.H. DOOR SLOPE SLOPE CONC. GARAGE FLOOR EXP. JOINTS AS REQ'D 4" CONC. SLAB SLOPE TO DRAIN ON 4" COMPACTED GRAVEL BASE @ 1/4" PER FT. BLOCK OUT FOR 20'-0" O.H. DOOR CONCRETE PAD WITH MANUFACTURER HOUSE EXEPT THE BACK OF HOUSE AND GARAGE. 8"X16" CONC. FOOTING 6"X28" CONC. FOUNDATION WALL W/ 1. ASSUME MIN. SOIL BEARING VALUE OF 1500 PSI- HOLD DOWNS 1 L E G E N D 7. VERIFY FLOOR TRUSSES AND MICROLAMS 4. ALL WOOD WITH-IN 1" OF CONC. OR 6" OF EXPOSED F O U N D A T I O N N O T E S: EARTH TO BE APPROVED TREATED WD OR HRT. REDWD AS REQ'D. 5. SLAB ON GRADE. 2. ALL FND. WALLS & FTG'S TO BE CONT. CONC. AS VERIFIES AS REQ'D. PRIOR TO CONSTRUCTION. SPEC -WALLS TO BE 6"X28" ON 16"X8" FTG'S OR FND. DESIGN & CONSTRUCTION. - CONTRACTOR 10 1/2" x 28" ON 24"x8" AS NOTED ON PLAN & DETAILS. TREATED GREEN BOARD SILL PL'S W/ 10" J BOLTS 3. FND. WALLS TO BE CAPPED WITH 2X6 PRESSURE APPROVED SILL SEALER AS REQ'D 72" O.C. & MAX 12" OF ALL JOINTS-SET ON 6. FOUNDATION DRAINS AROUND ALL SIDES OF THE SANDY LOAM & CLAY OTHER CONDITIONS MAY REQUIRE SPECIAL PROVISIONS. 12" SONOTUBE 4" CONC. SLAB ON 4" COMPACTED GRAVEL BASE HTT4 (SEE CHART - SHEET A5.0) 1 8"X24" CONC. FOOTING 10-1/2"X28" CONC. FOUNDATION WALL W/ SLOPE 4" CONC. SLAB CONC. GARAGE FLOOR EXP. JOINTS AS REQ'D SLOPE TO DRAIN ON 4" COMPACTED GRAVEL BASE 4'-0" 1'-6" 2'-6" 2'-0" 1050 FX 20'-0" 2'-0" 16'-0" 2'-0" 5'-4" 3'-11" DW DINING 9'-0" CEILING 10'-0" x 11'-10" VINYL 2X6 WALL 3'-0" 2650 SH 5'-6" 6'-6" 7'-6" 9'-0" CEILING W/H FURN UP 5-0 SLIDER COAT 16 RISERS 10" TREADS KITCHEN HRDWD 9'-0" CEILING ENTRY VINYL BATH VINYL 9'-0" CEILING LIVING ROOM 15'-0" x 11'-10" 25'-6" x 14'-10" CARPET 3030 SL 2-4 3-0 2-8 9' CLG / VINYL UTILITY 2-4 2-6 SW1 SW1 SW1 SW1 PANTRY 20'-0" 2-0 UP 72'-0" 51'-6" 3050 SH 3050 SH VINYL BATH 2-4 3-0 2040 FX 2040 FX 2040 FX 8'-9" 4'-0" 4'-0" 8'-9" 20'-0" 2'-0" 25'-6" 4'-0" 8'-4" 5'-9" 5'-3" CARPET 14'-6" x 10'-6" 8'-0" CEILING 7'-6" 5'-0" MSTR BDRM 3010 FX 4040 SL 20'-0" 7'-6" 3'-3" 2'-9" 4'-101 2" 4'-9" 2030 SH BATH 3'-61 2" 1'-8" 10'-2" 2040 SH 5'-10" 6'-4" 6'-01 2" 2'-4" 5'-8 1 2" BDRM #3 11'-5" x 11'-4" 8'-0" CEILING CARPET CARPET 4-0 BI-PASS 6'-21 2" 4040 SL FURN BATH 4010 FXD 4040 SL 4-0 BI-PASS 8'-0" CEILING BDRM #2 5'-81 2" 11'-5" x 11'-4" 2-6 2-6 2-4 2-4 2-4 2-6 DN ACCESS ATTIC DN 2-4 3010 FX 51'-6" 44'-0" 2-4 2020 FX 2020 FX TO BE 4X8 FIR BEAM (EXCEPT AS SHOWN) NOTE: ALL WINDOW AND DOOR HEADERS MICRO LAM BEAM/HEADER GIRDER TRUSS/TRUSSES (2) 9 1/2" MLAM (DN) 11 7/8" TJI 110's OR EQUAL @ 16" O.C. PRE-ENG MONO TRUSSES @ 24" O.C. L E G E N D OVER 7/8" OSB IN-WALL BOX GIRDER TRUSS IN-WALL BOX GIRDER TRUSS IN-WALL BOX GIRDER TRUSS 11 7/8" TJI 110's OR EQUAL @ 16" O.C. OVER 7/8" OSB (2) 11 7/8" MLAM (2) 11 7/8" MLAM HIP GIRDER TRUSS HIP GIRDER TRUSS PRE-ENG ROOF TRUSSES @ 24" O.C. HIP GIRDER TRUSS DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A3.0 APRIL 10, 2019 FRAMING & ROOF PLAN BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 4'-0" 1 SECOND FLOOR FRAMING 1/4"=1'-0" 0" 4'-0" 2 ROOF PLAN 1/4"=1'-0" STUCCO SHINGLE SIDING ARCHITECTURAL SHINGLES 30 YR. 12 5 DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A4.0 APRIL 10, 2019 EXTERIOR ELEVATIONS BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 4'-0" 1 SIDE ELEVATION 1/4"=1'-0" 0" 4'-0" 2 FRONT ELEVATION 1/4"=1'-0" ARCHITECTURAL SHINGLES 30 YR. 12 5 DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A4.1 APRIL 10, 2019 EXTERIOR ELEVATIONS BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 4'-0" 1 SIDE ELEVATION 1/4"=1'-0" 0" 4'-0" 2 REAR ELEVATION 1/4"=1'-0" R-21 INSULATION 7/8" T&G FLOORING ENGINEERED FLOOR TRUSSES 8'-0" R-30 INSULATION @ TRUSS & RIM JOISTS END 2x6 PRESSURE 7 16" OSB SHEATHING SIDING OVER 1 2" GYP. WALL BRD. OVER 2x6 WALLS @ 16" O.C. R-38 INSULATION PRE-ENG. ROOF TRUSSES @ 24" O.C. 16"x8" SOFFIT VENTS @ 8' O.C. 30 YEAR SHINGLES OVER 7/16" OSB R-21 INSULATION @ 2x6 WALLS 4" CONCRETE SLAB #4 BAR RUN HORIZ. (TYP. OF 2) TOP FTG. GRADE BOT. FTG. 1X6 FASCIA OVER 2x4 SUB FASCIA 1'-4" 5" 6" 5" 8" 9'-0" 1'-4" 2'-4" 2'-0" MIN. EXP. JOINT #4 BAR @ 48" O.C. VERICAL #4 BAR @ 24" O.C. HORIZ. TREATED SILL PL. 4" COMPACTED GRAVEL OVER 2" RIGID INSULATION & 6 MIL VAPOR BARRIER DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A5.0 APRIL 10, 2019 DETAILS BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 1 TYPICAL WALL SECTION 3 R602.10.6.4 3/4"=1'-0" 4 R602.10.4 N.T.S. N.T.S. PRESERVATIVE-TREATED BARRIER MAY BE REQ'D 3" MIN 8'-9" 8'-0" 8'-9" 25'-6" 3'-6" 3-0 8'-0" 11'-0" 25'-0" 11'-0" 3'-4" 2'-6" 13'-0" 3'-2" STORAGE UNFINISHED 1,122 S.F. FUTURE DOOR SEE SHEET A0.0 FOR GENERAL NOTES AND LEGENDS T T 4040 SL 4040 SL 13'-0" 18'-0" 13'-0" S.D. S.D. S.D. S.D. F F S S S S S S S S S S S DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A2.1 APRIL 10, 2019 UPPER FLOOR PLAN BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 4'-0" 1 UPPER FLOOR PLAN 1/4"=1'-0" 0" 4'-0" 2 ELECTRICAL PLAN 1/4"=1'-0" 12'-10" 5'-4" 13'-0" 7'-6" 3050 SH 3050 SH 3050 SH 9'-3" 4'-0" 4'-0" 13'-9" 6'-3" 3'-7" 3'-10" 6'-11" 4'-0" 4'-5" 2'-4" 28'-0" 15'-0" 6'-0" 9'-5" SW1 SW1 SW1 SW1 2 CAR GARAGE CONCRETE 403 S.F. 16'X8' O.H. GARAGE DOOR 20 MIN FIRE RATED SELF CLOSING SHOP AREA CONCRETE 766 S.F. 2 CAR GARAGE CONCRETE 677 S.F. 20'X8' O.H. GARAGE DOOR SW1 SW1 SW1 59'-8" SEE SHEET A0.0 FOR GENERAL NOTES AND LEGENDS T DOOR OPENER VENTS IN CEILING TYP DOOR OPENER S.D. 220V F F S S S S S S S S S S S S S S S S S S S S S S F T DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A2.0 APRIL 10, 2019 FLOOR PLAN BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 8'-0" 1 FLOOR PLAN 1/4"=1'-0" 0" 8'-0" 2 ELECTRICAL PLAN 1/4"=1'-0" @ 1/4" PER FT. 1 1 6'-0" 20'-0" 25'-6" 1'-101 2" 20'-3" 1'-41 2" 3'-0" 1'-6" 1'-101 2" 16'-3" 1'-10 1 2" 7'-0" 29'-0" 51'-6" 59'-8" 12'-4" 6'-0" 6'-6" 7'-6" 12'-0" 5'-8" 4'-0" 5'-6" 5'-0" 13'-6" 1 1 3'-10" 4" CONC. SLAB ON 4" COMPACTED GRAVEL BASE 8'-0" 1'-0" 1'-0" 3'-10" 3'-0" BLOCK OUT FOR DOOR DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A1.0 APRIL 10, 2019 FOUNDATION PLAN BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 8'-0" 1 FOUNDATION PLAN 1/4"=1'-0" EXHAUSTED TO THE OUTSIDE. AROUND TUB AND SHOWER ENCLOSURES. 9. ALL EXTERIOR DOORS TO BE SOLID CORE WITH 8. ALL EXTERIOR WINDOWS TO BE DOUBLE GLAZED. 10. ALL SWITCHES, PILOTS, & BURNERS TO BE A MIN. WEATHERSTRIPPING. ARE TO BE VENTED WITH A 90 C.F.M. FAN 7. BATHROOMS, UTILITY ROOMS AND TOILET ROOMS 2. ALL ANGLES TO BE 45° UNLESS OTHERWISE NOTED. 4. ALL SHOWER OR TUB INCLOSURES ARE TO HAVE 5. USE 5/8" TYPE 'X' GWB - SEAMS FIRE TAPED - @ HOUSE & GARAGE WALLS, AND GARAGE CLGS. G E N E R A L N O T E S: 1. EXTERIOR WALLS TO BE 2X6 STUDS 3. ALL WINDOWS WITHIN 18" OF FLOOR OR WITHIN 24" OF DOORS ARE TO BE TEMPERED. T S.D. C.O. 220V S F DRAWN BY: DATE: PROJECT NO. SHEET TITLE: REV: DATE: 43 NORTH SUBDIVISION 1911 NE 4TH & BADLEY MERIDIAN ID 83642 CONSTRUCTION DOCUMENTS MEGAN A0.0 APRIL 10, 2019 SITE PLAN BUILDING 8 CHECKED BY: O'NEIL PERMIT NO. 208.890.4342 tim@elkrunconstruction.com 0" 8'-0" 1 SITE PLAN 1/8"=1'-0" SPECIFICATIONS AND ELEVATIONS PRIOR TO PLAT MAP ON FILE W/ CITY / COUNTY AS REQ'D. 3. ALL UTILITES TO BE RUN UNDERGROUND. 1. ALL SETBACKS TO COMPLY W/ ALL CODES & ZONING REQUIREMENTS & TO BE VERIFIED BY 5. CONTRACOTR SHALL VERIFY ALL DIMENSIONS, 4. ALL DETAILS SHALL BE VERIFIED W/ CURRENT 2. WATER & SEWER BY CITY OR LOCAL WATER COR'D. BUILDING INSPECTOR PRIOR TO CONST. AS REQ'D. CONSTRUCTION. A R E A S MAIN FLOOR PLAN 942 S.F. DRIVEWAY 1,145 S.F. UPPER FLOOR PLAN 888 S.F. COVER SHEET & SITE PLAN D R A W I N G L I S T A0.0 N O T E S P R O P E R T Y A D D R E S S NE 4TH STREET & EAST BADLEY AVENUE MERIDIAN, ID A5.0 DETAILS HOUSE GARAGE CONCRETE 403 S.F. SHOP & GARAGE CONCRETE 1,440 S.F. EXTERIOR ELEVATIONS UPPER FLOOR PLAN A1.0 FOUNDATION PLAN A2.1 A4.0 TOTAL HOUSE AREA 1,834 S.F. CONCRETE SLABS: 0" 32'-0" 2 OVERALL SITE PLAN 1/32"=1'-0" A2.0 MAIN FLOOR PLAN A3.0 FRAMING & ROOF PLAN A4.1 EXTERIOR ELEVATIONS UPPER STORAGE AREA 1,122 S.F.