Loading...
REVISED A2.01 Plan & Building Elevations11'-6" 20'-6" 4'-0" 6'-6" 3'-6" 9'-0 3/4" 11'-5 1/4" 1300 Davenport Drive 318/377-1030 Minden, Louisiana 71055 CORPORATION FIBREBOND BLDG. NO. Made in the U.S.A. R 6" 6'-0" 10'-1 1/2" 10'-1 1/2" 6'-0" 6'-0" 6'-0" 3'-0" 2'-0" 3" 3" 3" LINE OF PREFABRICATED BUILDING by FIBREBOND. REFER TO FIBREBOND PERMIT SET, FOR BUILDING-TO-FOUNDATION CONNECTION DETAILS, ON SHEET B. 4" CONC SLAB (3,500 PSI MIN.) w/ 6x6 W2.1/W2.1 W.W.F.,OVER COMPACTED GRAVEL BASE. CLEAR CLEAR CLEAR #3 TIES @ 24" O.C. (6) #5 BARS HORIZONTAL CONC FOUNDATION (3,500 PSI MIN.) FINISHED GRADE MIN. 6" 1806 A201.DWG A2.01 AS NOTED PLAN & BUILDING ELEVATIONS CONSTRUCTION TYPE: LIGHTWEIGHT CONCRETE OUTSIDE DIMENSION: 11'6" W X 20'6" L X 10'1" H WEIGHT: 40,806 LBS. WIND DESIGN LOAD: 190 MPH FLOOR DESIGN LOAD: 150 PSF ROOF DESIGN LOAD: 150 PSF SEE FIBERBOND DRAWINGS CONST. DETAILS SCALE: PREFABRICATED OTN FLOOR PLAN - 236 S.F. A1 3/8" = 1'-0" SCALE: PREFABRICATED OTN BUILDING ELEVATIONS F1 3/8" = 1'-0" SCALE: PHOTOGRAPH OF SIMILAR PREFABRICATED OTN 0 2' 4' 5' 8' A12 NTS WEST ELEVATION CONCRETE PANELS WITH EXPOSED AGGREGATE. PAINTED STEEL DOOR AND FRAME. CONCRETE SLAB AND FOUNDATION. RE: DETAIL A8/A2.01 PAINTED TRIM. CONCRETE PANELS WITH EXPOSED AGGREGATE. CONCRETE PANELS WITH EXPOSED AGGREGATE. CONCRETE PANELS WITH EXPOSED AGGREGATE. PAINTED TRIM. PAINTED TRIM. PAINTED TRIM. MEMBRANE ROOF SYSTEM. MEMBRANE ROOF SYSTEM. MEMBRANE ROOF SYSTEM. MEMBRANE ROOF SYSTEM. W S E N CONCRETE WALL PANELS. RE: ELEVATIONS & FIBREBOND PERMIT DRAWINGS. SCALE: FOUNDATION / SLAB DETAIL A8 1"=1'-0" FIBREBOND ELEVATION "B" NORTH ELEVATION FIBREBOND ELEVATION "C" EAST ELEVATION FIBREBOND ELEVATION "D" SOUTH ELEVATION FIBREBOND ELEVATION "A" EMERGENCY GENERATOR A8 A2.01 A8 A2.01 A8 A2.01 A8 A2.01 CONCRETE SLAB AND FOUNDATION. RE: DETAIL A8/A2.01 CONCRETE SLAB AND FOUNDATION. RE: DETAIL A8/A2.01 CONCRETE SLAB AND FOUNDATION. RE: DETAIL A8/A2.01 REFER TO FIBREBOND PERMIT SET, FOR ADDITIONAL INFORMATION CONCERNING PREFABRICATED BUILDING . BUILDING-TO-FOUNDATION CONNECTION. REFER TO FIBREBOND PERMIT SET. BUILDING-TO-FOUNDATION CONNECTION. REFER TO FIBREBOND PERMIT SET. EQUIPMENT ROOM PREFABRICATED BUILDING, PLACED ON CONCRETE SLAB-ON-GRADE. RE: DETAIL A8/A2.01 FINISHED GRADE. CONCRETE LANDING w/ TURNED DOWNED EDGES CONCRETE LANDING at DOORS. A8 A2.01 A8 A2.01 A8 A2.01 A8 A2.01 WALL MOUNTED HVAC UNITS. GEN SET MUFFLER POWER CONNECTION CONCRETE LANDING w/ TURNED DOWNED EDGES WALL MOUNTED HVAC UNITS. REFER TO FIBREBOND PERMIT SET, FOR ADDITIONAL INFORMATION CONCERNING PREFABRICATED BUILDING , INCLUDING FIELD WORK REQUIRED. THESE DESIGNS AND DRAWINGS ARE THE EXCLUSIVE PROPERTY OF RUDEEN & ASSOCIATES ARCHITECTS, AND ARE NOT TO BE USED OR DUPLICATED WITHOUT PERMISSION. COPYRIGHT © 2012, ALL RIGHTS RESERVED. 1806 February 07, 2019 PREFABRICATED OTN BUILDING New Construction 1406 W. Cherry Lane Meridian, ID 83646 rudeenarchitects Boise + San Francisco 199 North Capitol Blvd. Suite 602 Boise, Idaho 83702 Phone 208-338-1413 Fax 208-336-0371 info@rudeenarchitects.com architecture planning project management CZC RESUBMITTAL SET WALL MOUNTED HVAC UNITS. WALL MOUNTED HVAC UNITS GEN SET MUFFLER 6' HIGH VINYL FENCE, BEYOND. 6' HIGH VINYL FENCE, BEYOND. 6' HIGH VINYL FENCE, BEYOND. 6' HIGH VINYL FENCE, BEYOND. 6' TALL VINYL SCREEN FENCE ALL SIDES 6' TALL VINYL SCREEN FENCE ALL SIDES 6' TALL VINYL SCREEN FENCE ALL SIDES 6' TALL VINYL SCREEN FENCE ALL SIDES