Loading...
REVISED A2 LANDSCAPE_ SITE PLAN _ Layout (1) (002)DATE:3/4/19 NETWORK ARCHITECTS COPE COLLISION WORKING DRAWINGS 1752 E. FRANKLIN RD. MERIDIAN ID 83642 PLOTDATE: Monday, March 4, 2019 A2 prosecuted to the fullest extent of the law at the minimum of $100,000 per incident. or referenced without prior written approval by Network Architects. All violations will be strictly controlled by US copyright law. This document and design may not be copied, emulated, © Copyright 2018 Network Architects. The use of this document and the home herein is JRS 12/21/18 D E S I G N O R I E N T E D P R O J E C T S 2517 W. NEFF CT. BOISE, IDAHO 83702 PHONE: 208-315-1967 www.networkarch.com Imagery ©2018 Google, Map data ©2018 Google 200 ft Updated just now Set a home address Set a work address Light tra1c in this area Typical conditions Meridian 90° Project Title: Report date: 08/15/18 Data filename: copeCOMCHK.cck Page 1 of 3 COMcheck Software Version 3.9.2 Envelope Compliance Certificate 2012 IECC Section 1: Project Information Project Type: New Construction Project Title : Construction Site: Owner/Agent: Designer/Contractor: Section 2: General Information Building Location (for weather data): Meridian, Idaho Climate Zone: 5b Building Type for Envelope Requirements: Nonresidential Vertical Glazing / Wall Area Pct.: 13% Building Type Floor Area Automotive facility 8486 Office 1883 Section 3: Requirements Checklist Envelope PASSES: Design 2% better than code. Climate-Specific Requirements: Component Name/Description Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U-Factor(a) South walls: Wood-Framed, 16" o.c. 1407 21.0 0.0 0.062 0.064 Window 1: Metal Frame:Double Pane with Low-E, Tinted, Fixed, SHGC 0.60 262 --- --- 0.250 0.380 Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, SHGC 0.60 46 --- --- 0.250 0.380 West Walls: Wood-Framed, 16" o.c. 2161 21.0 0.0 0.062 0.064 Window 1 copy 1: Metal Frame:Double Pane with Low-E, Tinted, Fixed, SHGC 0.60 202 --- --- 0.250 0.380 Door 1 copy 1: Glass (> 50% glazing):Metal Frame, Entrance Door, SHGC 0.60 46 --- --- 0.250 0.380 Door 3: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, SHGC 0.60 336 --- --- 0.136 0.380 Door 4: Other Door, Non-Swinging 196 --- --- 0.136 0.136 North Walls: Wood-Framed, 16" o.c. 1497 21.0 0.0 0.062 0.064 Door 4 copy 1: Other Door, Non-Swinging 196 --- --- 0.136 0.136 Door 6: Insulated Metal, Swinging 21 --- --- 0.250 0.370 East Walls: Wood-Framed, 16" o.c. 2102 21.0 0.0 0.062 0.064 Window 1 copy 1: Metal Frame:Double Pane with Low-E, Tinted, Fixed, SHGC 0.60 45 --- --- 0.250 0.380 Door 4 copy 2: Other Door, Non-Swinging 196 --- --- 0.136 0.136 Door 6 copy 1: Insulated Metal, Swinging 21 --- --- 0.250 0.370 Roof 1: Insulation Entirely Above Deck 1940 --- 30.0 0.032 0.039 Roof 2: Attic Roof with Wood Joists 8700 0.0 30.0 0.032 0.027 Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft. 447 --- 10.0 --- --- Project Title: Report date: 08/15/18 Data filename: copeCOMCHK.cck Page 2 of 3 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other' components require supporting documentation for proposed U-factors. Air Leakage, Component Certification, and Vapor Retarder Requirements: ❑ 1. Continuous air barrier is provided throughout the building thermal envelope. ❑ 2. Air barrier joints and seams are sealed. The joints and seals are securely installed in or on the joint for its entire length. ❑ 3. Penetrations of the air barrier and paths of air leakage are caulked, gasketed or otherwise sealed in a manner compatible with the construction materials and location. Joints and seals are sealed in the same manner or taped or covered with a moisture vapor-permeable wrapping material. The joints and seals are securely installed in or on the joint for its entire length. ❑ 4. The air barrier is continuous for all assemblies that are the thermal envelope and across the joints and assemblies. ❑ 5. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, tested to <=2.0 cfm, and are sealed with gasket or caulk. ❑ 6. Materials making up the air barrier have air permeability <=0.004 cfm/ft2 or are qualifying materials as per Section C402.4.1.2.1. ❑ 7. Air leakage of fenestration. Windows/non-glazed sliding and swinging doors/skylights with no weepage openings <= 0.20 cfm/ft2. Skylights with weepage <= 0.30 cfm/ft2. Curtain walls/storefront glazing <= 0.06 cfm/ft2. Doors: glazed swinging entrance/revolving/rolling <= 1.00 cfm/ft2. Doors: garage <= 0.40 cfm/ft2. Exceptions: ❑ Field-fabricated assemblies. ❑ 8. Doors and access openings from conditioned space to shafts, chutes stairways and elevator lobbies are gasketed, weatherstripped or sealed. Exceptions: ❑ Door openings required to comply with International Building Code as per Section C402.4.4. ❑ 9. Stairway and shaft vents are provided with Class I motorized dampers with a leakage rate <= 4 cfm/ft2. Dampers are installed with controls so that they are capable of automatically opening upon activation of any fire alarm or the interruption of power to the damper. ❑ 10.Outdoor air supply and exhaust openings are provided with Class IA motorized dampers having a leakage rate <=4 cfm/ft2. Exceptions: ❑ Gravity (nonmotorized) dampers having a leakage rate <=20 cfm/ft2 are permitted for exhaust and relief dampers for buildings less than three stories in height above grade, or where the design outdoor air intake or exhaust capacity <=300 cfm. ❑ Dampers smaller than 24 inches in either dimension are permitted to have a leakage <=40 cfm/ft2. ❑ 11.Cargo doors and loading dock doors are weather sealed. ❑ 12.Building entrance doors have a vestibule equipped with self-closing devices. Exceptions: ❑ Building entrances with revolving doors. ❑ Doors not intended to be used as a building entrance by the public, or intended solely for employee use. ❑ Doors that open directly from a space less than 3000 sq. ft. in area. ❑ Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. ❑ Doors opening directly from a sleeping/dwelling unit. ❑ 13.Component R-values & U-factors labeled as certified. ❑ 14.No roof insulation is installed on a suspended ceiling with removable ceiling panels. ❑ 15.'Other' components have supporting documentation for proposed U-Factors. ❑ 16.Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Except when instructed otherwise, edge joints between overlapping layers of continuous insulation are staggered. ❑ 17.Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5 Minimum Skylight-Daylighting Requirements: ❑ 18.In enclosed spaces > 10,000 ft2 directly under a roof with ceiling heights >15 ft. and used as an office, lobby, atrium, concourse, corridor, storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non-refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply unless exempted: ❑ The daylight zone under skylights is >= half the floor area; ❑ The skylight area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. Exceptions: ❑ Spaces where the proposed general lighting power densities < 0.5 W/ft2. ❑ Areas with obstructions that block direct beam sunlight on >= 1/2 of the roof over the enclosed area for more than 1,500 daytime hours per year between 8 am and 4 pm. ❑ Spaces where the daylight zone under rooftop monitors is > 50 percent of the enclosed space floor area. ❑ 19.Skylights in office, storage, automotive service, manufacturing, non-refrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight. Project Title: Report date: 08/15/18 Data filename: copeCOMCHK.cck Page 3 of 3 Additional Efficiency Package Requirements: ❑ 1. The reduced interior lighting power option has been selected as the additional efficiency package required by this energy code. Requirements for this package are applied to the interior lighting allowance calculations. Full compliance with this efficiency option requires inspection and verification that the interior lighting allowances and fixture schedule found in the interior lighting report are compliant and deemed to pass. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2012 IECC requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date SITE LOCATION NOT TO SCALE SITE 320 11th Ave S, Nampa, ID 83651 (208) 466-3331 DEVELOPER S 79'-53/4" 77'-10 3/4" 66'-3" 64'-2 1/2" 77'-11 3/4" 75' 69'-11 3/4" 25' 19' 85'-11" 103'-11" 48' 30' 22' 20' 6' 36'-1" 43'-43/4" 19'-91/2" 5' 5' 10,356.82 sq ft CONCRETE WALK CONCRETE SIDEWALK & GUTTER EXISTING APPROVED ACCESS VERIFY W/ CIVIL DRAWINGS 5' WIDE ACCESSIBLE ROUTE CONCRETE SIDEWALK & GUTTER GRASS LAWN 10' LANDSCAPE BUFFER LINE EXISTING OVERHEAD POWERLINES VERIFY ALL TREES PLANTED BELOW 15' MAXIMUM HT. SO AS NOT TO IMPEAD OR BECOME ENTANGLED WITH LINES. 6' DIA BARK MULCH RING AROUND BASE OF TREE. TO SEPARATE TREE TRUNK FROM GRASS LAWN (TYP) EXISTING IRRIGATION LINES AND HOOKUPS NEW SYSTEM TO STUB INTO EXISTING AT APPROPRIATE LOCATION V.I.F. W/ LANDSCAPE SUB CONTRACTOR 6' HIGH WIRE FENCING W/ CONCEALING FABRIC OVER AROUND WEST AND BACK OF THE REAR PORTION OF THE PROPERTY USE EXISTING CURB CUT ACCESS ONTO NOLA ROAD VERIFY W/ CIVIL DRAWINGS. FUTURE STORAGE BUILDING AND COVERED PARKING PLACED AT PROPERTY LINE TO HELP CONCEAL REAR PARKING AREA. 6' HIGH STUCCO CONCEALING WALL AROUND SOUTH AND EAST SIDES OF THE REAR PORTION OF THE PROPERTY GRAVEL AREA 5' LANDSCAPE BUFFER & SCREEN W/ SHRUBS AND TREES CREEPING THYME XERESCAPE NEW BUILDING COVERED ENTRY AND DROP OFF PARKING FOR BICYCLES UNDER THE ENTRY COVER SEE MAIN FLOOR PLAN & SPECIFICATION SHEETS OF BIKE RACK. COVERED STORAGE ASPHALT PARKING LOT 20' WIDE MOTORIZED GATE ENTRY W/ KEYPAD ACCESS 20' WIDE MOTORIZED GATE ENTRY W/ KEYPAD ACCESS 636.69' S 0˚ 28' 15" E 87.34' S 1˚ 18' 44" E 185.29' S 0˚ 28' 15" W 26.87' S 3˚ 28' 42" W 33.49' S 45˚ 15' 11" W 116.57' N 89˚ 57' 53" W 93.60' S 89˚ 57' 53" W 50.00' N 89˚ 57' 53" W 317.60' S 89˚ 57' 53" W 6.96' S 83˚ 06' 40" W 588.48' N 89˚ 34' 20" W 313.45' N 0˚ 00' 22" E E. FRANKLIN ROAD N. NOLA RD. 35' ROAD SETBACK LOT INFORMATION ZONING - I-L LOT SIZE= 75,335 SQ. FEET REQUIRED PARKING SPACES= 22 TOTAL BICYCLE PARKING 1 SPACE FOR EVERY 25 REQUIRED CAR SPACES. 1 BICYCLE SPACES REQUIRED & SINGLE RACK PROVIDED 24 TOTAL PARKING SPACES PROVIDED 2 ACCESSIBLE SPACES FRONT SETBACK 35' FROM ROAD CENTERLINE SIDE AND REAR SETBACKS 0' 25' ARTERIAL LANDSCAPE 10' LOCAL LANDSCAPE PLANTING KEY- ALL PLANTS TO BE VERIFIED AND INSTALLED AS A DESIGN BUILD CONTRACT WITH THE LANDSCAPE SUB - CONTRACTOR. COMMON NAME PLANTIING SIZE MATURE HT. MATURE SPREAD FLOWERING PLUM 5 GAL 15'-20' 15' FLOWERING PEAR 5 GAL 20'-30' 15'-18'' RED/AUTUMN BLAZE MAPLE 5 GAL 35'-45' 20'-25' OR OTHER TALL SHADE TREE GRASS LAWN SOD OR HYDRO SEED LAWN WITH POLYETHYLENE EDGING AT TRANSITION TO MULCHED AREA. BARK MULCH, STONES AND ANUAL PLANTING BEDS AREA FOR ANNUAL COLOR AND PLANTINGS AT VEHICULAR ACCESS POINTS V.I.F. W/ CLIENT. IRRIGATION NOTES: PRESSURIZED IRRIGATION TO BE DESIGN BUILD BY LANDSCAPER/ SUB- CONTRACTOR. VERIFY ALL PLANTINGS RECEIVE APPROPRIATE WATER AMOUNT. VERIFY IN FIELD WITH EXISTING WATER LINE, THE LOCATION AND SIZES OF ALL LINES MANIFOLDS, ANTI SIPHON VALVE AND ALL CLEAN-OUTS. STUB INTO EXISTING IRRIGATION LINES AT APPROPRIATE BOX AND LOCATION V.I.F. DUMPSTER/ TRASH RECEPTICAL SITE / LANDSCAPE PLAN 1" = 30'