18136 - Exalibur - Plans - L1.0 - CZC Landscape PlanE. WATER TOWER ST.
S. ADKINS WAY
PROPOSED
SHOP/SHOWROOM
(10,980 SF)
COVERED
ENTRY
SECURED
PARKING
PUBLIC PARKING
1C
10
5
PATIO AREA
6
1
2
2
2
3 3 3 3
4
5
5
5
6
6
1
TT
3
JH
5
PV
1
PO
3
EP
5
AR
6
SS
3
YF
6
PV
2
HS
2
HL
6
EP
1
HS
6
PV
2
HS
6
SS
3
YF
1
HS
2
HL
6
EP
6
PV
3
YF
6
SS
3
EP
9
SS
3
CC
5
JH
12
PO
3
JC
3
JC
6
CC
1
TT
1
JH
5
PV
7
MP
7
MP
5
MP
3
JC
3
PO
3
PO
6
JH
2
TT
7
EP
7
EP
7
EP
4
YF
1
L-1.0
2
L-1.0
3
L-1.0
4
L-1.0
PLANT SCHEDULE
QTY KEY BOTANICAL NAME COMMON NAME SIZE NOTES
DECIDUOUS SHADE TREES
5 AR Acer rubrum 'JFS-KW78' PP 25301 Armstrong Gold Maple 2" CAL. B&B Class II - 40' H x 12' W
9 CC Carpinus caroliniana 'Uxbridge' Rising Fire American Hornbeam 2" CAL. B&B Class II - 30' H x 15' W
4 TT Tilia Tomentosa 'Sterling' Sterling Silver Linden 2" CAL. B&B Class II - 45' H x 30' W
SHRUBS/PERENNIALS/ORNAMENTAL GRASSES
67 EP Echinacea purpurea 'Tiki Torch' Big Sky Tiki Torch Coneflower 1 gal. cont. 3' H x 2' W
6 HL Humulus lupulus 'Aureus' Common Hops 1 gal. cont. 25' H x 3' W
11 HS Hosta sieboldiana 'Elegans' Elegans Hosta 1 gal. cont. 2' H x 3' W
9 JC Juniperus chinensis 'Spartan' Spartan Juniper 6-7' HGT. B&B 15' H x 5' W
15 JH Juniperus horizontalis 'Bar Harbor' Bar Harbor Juniper 5 gal. cont. 1' H x 6' W
19 MP Miscanthus 'Purpurascens' Flame Grass 1 gal. cont. 5' H x 3' W
47 PV Panicum virgatum 'Heavy Metal' Heavy Metal Blue Switch Grass 1 gal. cont. 3' H x 2' W
19 PO Physocarpus opulifolius 'Mindia' Coppertina Ninebark 5 gal. cont. 8' H x 5' W
60 SS Sedum spurium 'Dragon's Blood' Dragon's Blood Sedum 1 gal. cont.
17 YF Yucca filamentosa 'Excalibur' Excalibur Yucca 2 gal. cont. 2' H x 3' W
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
D
C
B
A
L-1.0
CZC
LANDSCAPE
PLAN
LA-16654
S
T
A
T
E
O
F
I
D
A
H
O
L
I
C
E
N
S
E
D
L
A
N
D
S
C
A
P
E
A
R
C
H
I
T
E
C
T
B
E
N
J
A
M
I
N
S
H
A
W
S
E
M
P
L
E
reandpartners.com + 208-514-3300 + 1014 S. La Pointe, Boise, Idaho 83706
LANDSCAPE ARCHITECTURE
+ URBAN DESIGN
+ LAND PLANNING
+ GRAPHIC COMMUNICATION
+ PROJECT MANAGEMENT
PRELIMINARY
NOT FOR
C O N S T R U C T I O N
SCALE: 1" = 20'-0"
C Z C L A N D S C A P E P L A N
DELTA DATE DESCRIPTION- COMMENTS
EXCALIBUR METAL DESIGN
HATCH DESIGN
ARCHITECTURE
6126 W. STATE ST.
BOISE, IDAHO 83703
OFFICE: (208) 475-3204
FAX: (208) 475-3205
THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED OR
COPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BE
ASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENT
AND PROPER COMPENSATION TO HATCH DESIGN
ARCHITECTURE.
THE USE OF THE PLANS SHALL BE RESTRICTED TO THE
ORIGINAL SITE FOR WHICH THEY WERE PREPARED.
DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,
INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BY
THE DESIGNER AND THE DESIGNER'S CONSULTANTS ARE
INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT
TO THIS PROJECT. THE DESIGNER AND THE DESIGNER'S
CONSULTANTS SHALL BE DEEMED THE AUTHORS AND
OWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICE
AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND
OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.
SHEET TITLE
SHEET NUMBER
SHEET
NEW CONSTRUCTION FOR:
1322 E. WATER TOWER ST. MERIDIAN, ID, 83642
DATE:
JOB NUMBER: 18136/18052
DEC 2018
DRAWN BY:
CHECKED BY: BSS
BSS
C O P Y R I G H T 2 0 1 8
H A T C H D E S I G N
A R C H I T E C T U R E
LANDSCAPE NOTES:
1. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE
PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.
2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL.
ALTERNATE MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF SPECIFIED PLANT MATERIALS CAN
NOT BE OBTAINED.
3. COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS.
4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION
START-UP.
5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS.
6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN.
PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.
7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL
OUT SYMBOL NUMBERS.
8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF 1" MINUS BARK MULCH OVER APPROVED
TOPSOIL . SUBMIT SAMPLE FOR APPROVAL.
9. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE
BY THE OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE
SAME SIZE AND SPECIES AT NO COST TO THE OWNER.
10. FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE
IN ACCORDANCE WITH THE SITE CIVIL GRADING PLAN.
11. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC YARDS OF APPROVED COMPOST PER 1000 SQUARE
FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL.
12. FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS. QUANTITY PER MANUFACTURER'S
RECOMMENDATIONS.
13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18" DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE A MINIMUM 12" DEPTH
OF TOPSOIL. SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3" BELOW ADJACENT
SURFACES OF PLANTER BED AREAS, 1-1/2" BELOW ADJACENT SURFACES OF TURF SOD AREAS, AND 1" BELOW
ADJACENT SURFACES OF TURF SEED AREAS.
14. REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE
INSUFFICIENT. VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. PERFORM SOIL TEST/
ANALYSIS AND PROVIDE ADDITIONAL AMENDMENT AS DETERMINED BY SOIL TESTS. TOPSOIL SHALL BE A LOOSE,
FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR
OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM
STANDARDS, CONTRACTOR IS RESPONSIBLE TO EITHER:
A) PROVIDE APPROVED IMPORTED TOPSOIL, OR
B) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT.
15. IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE, NATURAL LOAM,
SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS,
STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL
TO PLANT GROWTH.
A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THOSE
FOUND ON THE PROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL
OCCURS AT A DEPTH OF NOT LESS THAN 4 INCHES.
B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, TOXICITY, AND GENERAL TEXTURE BY A
RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND
RECOMMENDATIONS SHALL BE FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL
SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION. ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.
16. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND
DISPOSE OF PROPERLY OFF SITE.
17. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0" CLEAR ZONE OF ALL STORM DRAIN PIPE, STRUCTURES, OR FACILITIES.
18. STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION
AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM.
19. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.
LANDSCAPE LEGEND
QUANTITY
PLANT IDENTIFICATION KEY
EXISTING TREES / PLANTS
TO REMAIN
TREES / PLANTS TO BE INSTALLED
CORTEN STEEL EDGING
PROPERTY LINE (VERIFY)
2
QC
CALLOUT NOTES # CALLOUT NUMBERS
REFER TO NUMBERED
NOTES BELOW
MAINTAINED LAWN AREAS
TURF SOD AND TOPSOIL AS
SPECIFIED
1" MINUS BARK MULCH OVER
TOPSOIL AS SPECIFIED
LANDSCAPE REQUIREMENTS
TOTAL SITE AREA: 36,105 ± S.F. - 0.83 ACRES
TOTAL LANDSCAPE AREA: 5,851 S.F.
LANDSCAPE BUFFER REQUIREMENTS:
SOUTH BOUNDARY STREET BUFFER: 171 LIN. FT. (WATER TOWER ST.)
TREES REQUIRED - 4
TREES PROVIDED - 5 PROPOSED
WIDTH OF BUFFERS REQUIRED: 20'
WIDTH OF BUFFERS PROVIDED: 20'
WEST PERIMETER BUFFER: 205 LIN. FT. (COMMERCIAL SITE)
TREES REQUIRED - 6
TREES PROVIDED - 6 PROPOSED
WIDTH OF BUFFER REQUIRED: 5'
WIDTH OF BUFFER PROVIDED: VARIES 6'-7'
NORTH PERIMETER BUFFER: 177 LIN. FT. (COMMERCIAL SITE)
TREES REQUIRED - 6
TREES PROVIDED - 6 (2 PROPOSED, 4 EXISTING ON ADJACENT
PROPERTY)
WIDTH OF BUFFER REQUIRED: 5'
WIDTH OF BUFFER PROVIDED: 10'
EAST BOUNDARY STREET BUFFER: 199 LIN. FT. (ADKINS)
TREES REQUIRED - 6
TREES PROVIDED - 6 PROPOSED
WIDTH OF BUFFER REQUIRED: 10'
WIDTH OF BUFFER PROVIDED: 15'
WIDTH OF PARKING LOT PERIMETER LANDSCAPE STRIP: VARIES
BETWEEN 5' - 10'
BUFFER BETWEEN DIFFERENT LAND USES: NOT APPLICABLE
NUMBER OF PARKING STALLS: 22
TOTAL NUMBER OF TREES: 18
TOTAL NUMBER OF TREE SPECIES:
REQUIRED - 3
PROPOSED - 3
TREE MITIGATION: ALL EXISTING TREES ON PROPERTY AND
ADJACENT PROPERTIES SHALL BE SAVED AND PROTECTED
1. TRASH ENCLOSURE
2. VISION TRIANGLE
3. EXISTING TREE
4. BIKE RACK
5. TREE GRATE IN PLAZA
6. IRRIGATION EASEMENT
3 SHRUB PLANTING NOT TO SCALE
1. SHRUB SHALL BEAR SAME RELATIONSHIP TO GRADE AS IT DID IN NURSERY.
2. WATER SHRUB TWICE WITHIN FIRST 24 HOURS.
3. THIN BRANCHES AND FOLIAGE BY 1
3.
4. DO NOT CUT LEADERS TO RETAIN NATURAL SHRUB SHAPE.
5. FOR CONTAINER GROWN PLANTS THAT ARE ROOTBOUND, SPLIT THE ROOTBALL WITH 3 EQUAL SPACED
VERTICAL CUTS.
NOTES:
REMOVE ANY PLASTIC, BURLAP, NAILS, OR OTHER
MATERIALS FROM THE ROOTBALL WHICH MAY LIMIT
ROOT GROWTH
CONSTRUCT 2" EARTH BERM TO FORM A WATER
RETENTION BASIN, FILL BERM WITH MULCH, AS
SPECIFIED
MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO
NOT COVER CROWNS OF PLANTS
PROVIDE COMMERCIAL FERTILIZER TABLETS AND
BIOSTIMULANT, AS SPECIFIED, FOR EACH SHRUB
BACKFILL WITH APPROVED TOPSOIL AND SOIL
AMENDMENTS, AS SPECIFIED. BACKFILL IN 6" LIFTS,
WATER EACH LAYER, DO NOT TAMP OR OVER
COMPACT.
CONSTRUCT 6" MOUND OF TOPSOIL
DECIDUOUS TREE IN PLAZA
2 PLANTER NOT TO SCALE
LIMB TREE TO 8'-0" ABOVE
SIDEWALK GRADE
TREE GRATE AS SPECIFIED
BARK MULCH LAYER - 3"
DEPTH. SET ROOT BALL 1"
ABOVE ADJACENT FINISH
GRADE
TREE ROOT BARRIER- 1/2"
ABOVE GRADE
FINISH GRADE
COMMERCIAL FERTILIZER
TABLETS
3
4" MINUS DRAIN GRAVEL
ROOT ZONE SPRINKLER, SEE
ROOT ZONE SPRINKLER IN
IRR. DETAILS
UNDISTURBED SUBSOIL
1. PLANT TREE IN CENTER OF WELL.
2. REFER TO DECIDUOUS TREE PLANTING FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
NOTES:
BACKFILL WITH APPROVED TOPSOIL AND SOIL
AMMENDMENTS AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER
EACH LAYER, TAMP LIGHTLY AS REQUIRED, BACKFILL SOIL
EVEN W/ TOP OF ROOTBALL, DO NOT OVER COMPACT!!
ISOMETRIC VIEW
SECTION
4 CORTEN METAL EDGING NOT TO SCALE
CORTEN STEEL EDGING,
TOP OF EDGING TO BE A
MAXIMUM OF 1
2" ABOVE
SURFACE MATERIAL
BED MEDIA OR
AGGREGATE
COMPACT GRADES
ADJACENT TO EDGING
TO AVOID SETTLING
EDGING PEGS SPACED 5'
ALONG LENGTH OF
EDGING AND AT ALL
JOINTS
ATTACHMENT
SCREWS
(4 PER PEG)
EDGING PEGS
1 DECIDUOUS TREE PLANTING NOT TO SCALE
SOIL LINE
ROOT FLARE TO BE AT SOIL LINE
NOTES:
1. REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP 2
3 OF ROOTBALL. REMOVE ALL NAILS, TIES, AND PLASTIC FROM
ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY
BIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL.
2. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO ENSURE
THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEAR
AFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THE
WARRANTY PERIOD.
3. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE
ARCHITECT BEFORE PROCEEDING.
4. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT
MATERIAL.
5. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING
METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE.
6. WATER TREE TWICE WITHIN THE FIRST 24 HOURS.
7. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.
8. FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER (DEEPROOT
#24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. ALL TREE INSTALLATIONS
SHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS.
REMOVE DEAD/DAMAGED BRANCHES AND
PRUNE TO INTERNATIONAL SOCIETY OF
ARBORICULTURE STANDARDS; IMPROPERLY
PRUNED TREES (AS DETERMINED BY THE
LANDSCAPE ARCHITECT) SHALL BE REMOVED
AND REPLACED. DO NOT REMOVE MAIN
LEADER!!
RUBBER CINCH TIE
2"x 2" WOOD STAKE (LENGTH AS
REQUIRED)-DO NOT PENETRATE ROOTBALL.
SEE NOTE 1. SET STAKES PARALLEL TO
PREVAILING WIND.
REMOVE TREE WRAP TRUNK PROTECTION,
AFTER INSTALLATION
CONSTRUCT 2" EARTH BERM AT EDGE OF
ROOTBALL, FILL TREE RING W/ MULCH, AS
SPECIFIED.
3" THICK MULCH LAYER, KEEP MULCH 3" AWAY
FROM TRUNK.
FINISH GRADE
PREVAILING WIND DIRECTION
COMMERCIAL SLOW RELEASE FERTILIZER
TABLETS
SIDES OF HOLE ROUGH & UNEVEN
BACKFILL WITH APPROVED TOPSOIL AND
SOIL AMENDMENTS AS SPECIFIED.
BACKFILL IN 6" LIFTS, WATER EACH LAYER,
TAMP LIGHTLY AS REQUIRED, BACKFILL
SOIL EVEN W/ TOP OF ROOTBALL,
DO NOT OVER COMPACT!!
SET ROOTBALL ON NATIVE, UNDISTURBED
SOIL