Loading...
FP-13-006 MULBERRY SUBDIVISIONOlrft IDIAN Planning Department lUi\i-]!) FINAL PLAT r Application Checklist Proiect name: Mulberry Park Subdivision Applicant/agent: Settlers Park LLC /Becky McKay, Engtqqe1rnglqlqqng,llB All applications are required to contain one copy of the following: Note: Only one copy of the above items need be submitted when submitting multiple applications Additional Requirements for Final Plat Applications: 33 E. Broadway Avenue, Suite 210 o Meridian, Idaho 83642 Phone: (208) 884-5533 o Facsimile: (208) 888-6854 I Website: www.meridiancity.org (Rev. 1 l/4/08) & Commission & Council Review Narrative fully describing the proposed project Legal description ofthe subject property (Lot, Block, and Subdivision name iflocated in a recorded subdivision OR a metes and bounds legal description of the property if not in a sgbc!!vis!qn.) Affidavit of Legal Interest signed & notarized by the properfy owner (lf owner is acorporation, submit a copy of the Articles of Incorporation or other evidence to show that the person signing Ls CryCqS!?g1lgCglA Scaled vicinity map showing the location of the subject properfy (lf this is a phased development, show this phase in relation to previously approved phases.) Fee (Please call Planning Department to cqlculate correct fee. Applications with incorrectfees will not be accepted.) Include the following additional information in the project narrative: requirements or conditions thereof. If not in conformance, describe the proposed changes and why they are needed.* surveying practices and local standards. recorded instrument number Copy of the approved preliminary plat (8 Yz" x ll") Copy of the "final" Ada County Sffeet Name pyg!4!o4 Lg!g! Detail of any proposed amenities (tot lot play equipment, etc.) InCZC Submit lot closure sheet for plat t. ,UI i I Submit two (2) sets of final engineering construction drawings for streets, water, sewer, sidewalks, irrigation and other public improvements with two (2) copies of the final plat attached to Public Works Department for approval (208-s98-5500). These drawings must be stamped and signed by a registered engineer/surveyor in the State ofldaho. Storm drainage calculations must be submitted for private drives and parking areas within subdivisions Applicant's engineer is required to submit a signed, stamped statement certif,ing that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. N/A Submit cross section (civil plan drawing) of private street to planning department /1ft (if applicable) Recorded warranfy deed for the subject properry L/ l/ t-/ pinii ptat-S2 copies (not including copies for P.W. above), dimensions of 18" x 27" per Idaho Code (folded to I k" x I l" size) The following items must be included on the final plat: a name a Year of Section location and a North arrow ffi a Scale of smaller than I ":1 a Streets and alleys with widths and bearings Street names a Consecutive of all lots in each b and each block numbered a Each and all ofthe boundaries ofeach lot curve and./or line table ./ Exterior boundaries shown by distance and bearing (heavier lines than streets and lots) curve and/or line table a of monuments a Initial point and tie to at least two public land survey corners or, in lieu thereof, to two monuments the orC or a Common area lots and/or landscape easements and easements show on the a Pertinent notes for etc. a Basis of a Land seal a Land business name and address a of ls a subdivision names Reduction of the final plat (8 %" x 11") sheet ofthe final 4 N/A Landscape plan - 3 copies (folded to 8 %" x I l" size) NOTE: Internal (parking lot) landscaping will not be reviewed with the final plat for commercial developments unless a separate CZC application is submitted concurrently. PlanmusthaveascalenosmallerthanI":50'(l":20'ispreferred)andbeonastandarddrawing sheet,nottoexceed36"x48"(24"x36"ispreferred). Aplanwhichcannotbedrawninitsentirety on a single sheet must be drawn with appropriate match lines on two or more sheets. The follow items must be included on the a Date, scale, north arrow, and project name a Names, addresses, and telephone numbers of the developer and the person and./or f,rm the a Stamp/signature ofa landscape architect, Iandscape designer, or qualified nurseryman preparing the plan. a Existing natural features such as canals, creeks, drains, ponds, wetlands, floodplains, groundwater areas, and rock outcroDpinss a Location, size, and species of all existing trees on site with trunks 4 inches or greater in diameter, measured 6 inches above the ground. Indicate whether the tree will be retained or removed. a A statement of how existing healthy trees proposed to be retained will be protected from damage during construction a Existing buildings, structures, planting areas, light poles, power poles, walls, fences, berms, parking and loading areas, vehicular drives, trash areas, sidewalks, pathways, stormwater detention areas, signs, street furniture, and other man-made elements. aBerms Existing and proposed contours for all areas steeper than20o/o slope. shall a a a a be shown with one-foot contours. If the number of buildable lots has increased or there has been an overall reduction in the amount of open space, the final plat shall be determined not to be in substantial compliance with the preliminary plat. If the Director - determines that there is substantial difference in the final plat than that which was approved as a preliminary plat or conditions that hove not been met, the Director may require that a new preliminary plat be submitted to the Commission (UDC I l-68-3C2b) APPLICATION WILL NOT BE ACCEPTED UNLESS ALL APPLICABLE ITEMS ON THE CHECKLIST ARE SUBMITTED, a Site Triangles as defined in 1l-3A-5 of this ordinance. Location and labels for all proposed plants, including trees, shrubs, and groundcovers. Scale shown for plant materials shall reflect approximate mature a slze. A plant list that shows the plant symbol, quantity, botanical name, corlmon name, minimum planting size and container, tree class (I, II, or III), and comments (for and installation as a aall Planting and installation details as necessary to ensure conformance with standards. a Location and I ofall proposed fencing Calculations of project components to demonstrate compliance requirements of this ordinance, including: > Width of street buffers, lineal feet of street frontage, and number of street trees ) Residential subdivision trees ) Acreage dedicated for common open space ) Number of trees provided on common lot(s) a with the for removal of trees N/xllA Reduction of the 8Yz" Electronic version of the approved preliminary plat, format on a disk with the files named with project name & plan type (i.e. approved preliminary plat, final plat, landscape plan, amenities, etc.). We encourage you to submit at least one color version for final plat, & landscape plan in pdf Barbara Shiffer From: Sent: Subject: Machelle Hill Wednesday, February 13, 2013 1 1 :55 AM FW: City of Meridian Dev App - Mulberry Subdivision FP 13-006 From: Machelle Hill Sent: Wednesday, February 13,207311:53 AM Subject: City of Meridian Dev App - Mulberry Subdivision FP 13-006 ilNAHO City of Meridian City Clerk's Office 33 E. Broadway Avenue Meridian, ID 83642 City Council D evelo pme nt Ap p lic ation Trans mittsl To: Citv Departments Comments due by: February 19,2013 Transmittal Date: February 13,2013 File No.: FP 13-006 Hearing Date: February 26,2013 Request: Final Plat approval consisting of 5 multi-family residential building lots on approximately 2.4 acres of land in an R-15 zoning district for Mulberry Subdivision By: Settlers Park, LLC Location of Property or Proiect: SWC of N. Meridian Road and W. Ashby Drive City Council Action: The City of Meridian is requesting comments and recommendations on the application referenced above. To review detailed information about the request, please click on the file number above to take you directly to the application. We request that you submit your comments or recommendations by date specified above. When responding, please reference the file number of the project. lf responding by email, please send comments to clerk@meridiancitv.orq. For additional information associated with this application please contact City Clerk's Office at number below. Thank you, Machelle Hill Meridian City Clerk's Office 33 E. Broadway Avenue Meridian, lD 83642 (208) 888-4433 m h ill@meridiancity. orq 1 Changes to Agenda: None ry Item #7A: Mulberry (FP.13-006) Application(s): ) Final Plat Size of property, existing zoning, and location: This site consists of approximately 2.4 acres, is cunenfly zoned R-15 and is located on the southwest corner of W. Ashby Drive and N. Meridian Road. Summary of Request: The applicant has applied for final plat approval consisting of five (5) multi-family residential lots. The l\,4ulberry Subdivision was approved by City Council on october g, 2012. Concurrently, Council appioved a conditional use permit that allows the proposed lots to develop with thirty-six (36) multi-family units. Landscaping for the site is also tied to the approval of the conditjonal use permit and will be reviewed for conformance with a future certificate of zonrng compliance and administratve design review application. Staff has reviewed the proposed finalplat for consistency with the approved preliminary plat and City Code. The proposed plat is found it to be in substantial conformance with the approved preliminary plat. Written Testimony: The applicant is in agreement with the conditions of approval contained in the staff report. Outstanding lssue(s) for City Council: None Notes: ilLN A0a du-r-*s'