Loading...
Gardner Homes Office Site Plan_12-21-2018 (002) RevisionX X X X X X X X X X X w ss ss ss ss ss ss ss ss ss ss w w w w w w w w w w w w w w w w ss s w w w w w w w w ss ss ss pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi pi 2078 W EVEREST LN. MERIDIAN, ID 83646 PROPOSED OFFICE BUILDING 3,300.69 SF FINISHED FLOOR ELEVATION 19'-7" 5.5' 7' 10' 7' 5' 7.2' 7.8' 11.6' 6.5' 5.8' 12.8' 14' 8' 6' 25' 19' 8.5' 2.6' 6.5' 9' 19' 9' 12' 12' 25' H:\!2018\ID-1403-1810 Gardner Homes Office Building\Project Data\02 CAD\2.03 Sheet Files\Construction Drawings\PLANS\ID-1403-1810_C05_SITE PLAN.dwg - Layout1 - 12/21/2018 11:18am, mattc 1 5 REVISIONS REV # DATE DRAWING INFO DATE DESIGNED DRAWN *SEE GENERAL NOTES SHEET WARNING 0 1 2 IF THIS BAR DOES NOT MEASURE 2" THEN DRAWING IS NOT TO SCALE www.horrocks.com PAGE C PROJECT CHECKED D B A # 2 3 4 2775 W. Navigator Dr., Suite 210 Meridian, ID 83642 (208) 895-2520 PRELIMINARY NOT FOR CONSTRUCTION ########### ##### #### #### 12-12-2018 ################# SITE PLAN EXHIBIT GARDNER HOMES OFFICE BUILDING ADDRESS, CITY, STATE # ##### H O R R O C K S E N G I N E E R S N 0 10' 20' SCALE: 1" = 10' PARKING ANALYSIS REQUIREMENTS REQUIRED PROVIDED CITY OF MERIDIAN PARKING REQUIREMENTS (1 SPOT PER 500 SF) 7 STALLS 13 STALLS BUILDING ANALYSIS BUILDING AREA TOTAL 3,300.69 SF MAIN FLOOR 3,300.69 SF MAX BUILDING HEIGHT 17-0" BUILDING TYPE (IBC) * VB* NOTES: * BUILDING TYPE TO BE VERIFIED WITH ARCHITECTURAL PLANS, ARCHITECTURAL PLANS TO SUPERCEDE. LIGHT DUTY ASPHALT, SEE FLEXIBLE PAVEMENT SECTION TABLE, THIS SHEET CONSTRUCT ADA RAMP PER (ISPWC SD-712G) W/ TRUNCATED DOMES PER (ISPWC SD-712) CONCRETE SIDEWALK PER (ISPWC SD-709) ALL SIDEWALK TO HAVE 4" OF 3/4" MINUS BASE, MIN. CONCRETE TO BE 3,600 PSI IN 28 DAYS ADA ACCESSIBLE PARKING STALLS TO COMPLY WITH ADA STANDARDS, SECTION 502 12' X 12' DUMPSTER PAD. SEE DETAIL X THIS SHEET. SEE ARCHITECTURAL PLANS FOR DUMPSTER ENCLOSURE DESIGN INFORMATION. BIKE RACK, SEE ARCHITECTURAL PLANS FOR DETAILS 1.5' FLAT PAN CURB AND GUTTER PER DETAIL X THIS SHEET SAWCUT EXISTING ASPHALT 2' FROM EXISTING EDGE. TACK COAT SHALL BE APPLIED TO JOINT AT SAWCUT. TACK COAT SHALL BE CSS-1 DILUTED EMULSIFIED ASPHALT APPLIED AT A RATE OF 0.07 GAL/SY. SEE ISPWC SD-806 LANDSCAPING, SEE SHEET L.1.0 FOR DETAILS ADA HANDICAP SIGN SEE DETAIL X, THIS SHEET PROPOSED TRANSFORMER LOCATION AS REQUIRED BY ELECTRICAL POWER COMPANY 1 SITE PLAN KEY NOTES: 2 3 4 5 6 7 8 9 10 1. DRIVE AISLE DIMENSIONS MEASURED TO FACE OF CURB, WHERE CURB IS PROPOSED OR TO EDGE OF PAVEMENT OTHERWISE. LENGTH OF CURB IS MEASURED TO THE TOP BACK OF CURB. SHEET NOTES: 11 SCALE: A - TYPICAL HANDICAP SIGN DETAIL NTS CAP TOP OF POST 3/8"X3 1/2" CADMIUM PLATED HEX HEAD BOLT WITH FLAT LOCK WASHER AND NUT 4" 6'-0" 6" 18" 12" BLUE BACKGROUND W/ WHITE SYMBOL AND LETTERING PROVIDE SIGN THAT IDENTIFIES ALL VAN ACCESSIBLE STALLS. REFER TO PLAN FOR LOCATIONS NOTE: TOP OF POST TO BE CUT 1/2" BELOW TOP OF SIGN SCALE: 2 - FLAT PAN CURB NTS NO.4 REINF. RODS SECTION B-B 3,600 PSI CONCRETE 12" O.C. BOTH WAYS NO.4 REINF. RODS 8" A.B.C. 12" 6" 12" 2" PLAN 6" 12' 12' 1% SLOPE TO FRONT B B SCALE: 3 - DUMPSTER PAD NTS COMPACTED SUB-GRADE FIN. GRADE (W/ LIP FLAT) CONC. CURB & GUTTER 3/4'' GRAVEL ROAD BASE ASPHALT PAVEMENT 1.0' 0.5' 0.5' 1-1/2''± 2'' 1.5' FLEXIBLE PAVEMENT SECTION SUMMARY CLASSIFICATION LIGHT DUTY ASPHALTIC CONCRETE 2.5" CRUSHED AGGREGATE BASE 4.0" STRUCTURAL SUBBASE 12.0" SUBGRADE PREPARATION (MAX LIFT PER GEOTECHNICAL REPORT) SEE PAVEMENT SUBGRADE PREPARATION SECTION NOTES: FLEXIBLE PAVEMENT SPECIFICATIONS ARE PER GEOTECHNICAL REPORT PREPARED BY XXX AND DATED XX-XX-201X MATERIAL SPECIFICATIONS: ASPHALTIC CONCRETE: ASPHALT MIX SHALL MEET THE REQUIREMENTS OF THE ISPWC, SECTION 810 CLASS III PLANT MIX. MATERIALS SHALL BE PLACED IN ACCORDANCE WITH ISPWC STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. AGGREGATE BASE: MATERIAL COMPLYING WITH ISPWC STANDARDS FOR CRUSHED AGGREGATE MATERIALS STRUCTURAL SUBBASE: GRANULAR STRUCTURAL FILL MATERIAL COMPLYING WITH THE REQUIREMENTS DETAILED IN THE THE STRUCTURE FILL SECTION OF THE GEOTECHINCAL REPORT (PREPARED BY MTI DATED 4-11-2017) EXCEPT THAT THE MAXIMUM MATERIAL DIAMETER IS NO MORE THAN 2 3 THE COMPONENT THICKNESS. GRADATION AND SUITABILITY REQUIREMENTS SHALL BE PER ISPWC SECTION 801, TABLE 1. LD - IT WILL BE REQUIRED FOR MTI PERSONNEL TO VERIFY SUBGRADE COMPETENCY AT THE TIME OF CONSTRUCTION 1 1 4 6 11 6 10