Loading...
CC - Approved Landscape PlanX L 11 J G F U E e` a a� c 0 D o 0 co O Q - U) a C C 0 0 Q B _v B 0 0 0 0 L0 L0 O AN 0 L- C) _I C6 I I I I I I I I I ------------- T N LANDSCAPE PLAN LANDSCAPE NOTES: ggg�!Ilp I. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHIGH IMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK. 2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE MATERIALS OF 51MILAR 51ZE AND CHARACTER MAY BE GON51DERED IF SPECIFIED PLANT MATERIALS GAN NOT BE OBTAINED. 3. COORDINATE ALL WORK WITH ALL OTHER 51TE RELATED DEVELOPMENT DRAWINGS. 4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION START-UP. 5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS. 6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. 7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND GALL OUT SYMBOL NUMBERS. 8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF SMALL I" MINUS BARK MULCH. SUBMIT SAMPLE FOR APPROVAL. G. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BE6INNIN6 AT THE DATE OF ACCEPTANCE BY THE OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME 51ZE AND SPECIES AT NO G05T TO THE OWNER. 10. FINISH 6RADE5 SHALL PROVIDE A SMOOTH TRANSITION WITH ADJAGENT SURFACES AND ENSURE POSITIVE DRAINAGE IN ACCORDANCE WITH THE SITE GRADING PLAN. II. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE GUBIG YARDS OF APPROVED GOMP05T PER 1000 SQUARE FEET. ROTO -TILL ORDANIG MATTER A MINIMUM OF (9 INCHES INTO TOPSOIL. 12. FERTILIZE ALL TREES AND SHRUBS WITH 'ADRIFORM' PLANTING TABLETS. QUANTITY PER MANUFAGTURER'5 RECOMMENDATIONS. 13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18" DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE A MINIMUM 12" DEPTH OF TOPSOIL. SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3" BELOW ADJAGENT 5URFAGE5 OF PLANTER BED AREAS, 1-1/2" BELOW ADJAGENT SURFACES OF TURF 500 AREAS, AND I" BELOW ADJAGENT SURFACES OF TURF SEED AREAS. 14. REUSE EXISTING TOP501L STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. PERFORM SOIL TEST/ ANALYSIS AND PROVIDE ADDITIONAL AMENDMENT AS DETERMINED BY 501L TESTS. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, GLEAN AND FREE OF TOXIG MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, 6RA55 OR OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTOR 15 RESPONSIBLE TO EITHER: A) PROVIDE APPROVED IMPORTED TOPSOIL, OR B) IMPROVE ON-SITE TOP501L WITH METHODS APPROVED BY THE LAN05GAPE ARCHITECT. 15. IF IMPORTED TOP501L FROM OFF-51TE SOURCES 15 REQUIRED, ENSURE IT 15 FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIG MATTER HARMFUL TO PLANT GROWTH. A) OBTAIN TOP501L FROM LOCAL SOURCES OR FROM AREAS HAVING 51MILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE PROJEGT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL -DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4 INCHES. B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, TOXICITY, AND GENERAL TEXTURE BY A REG06NIZED COMMERCIAL OR GOVERNMENT ADENGY AND COPIES OF THE TESTING ADENGY'5 FINDINC75 AND RECOMMENDATIONS SHALL BE FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOP501L SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION. ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6. I6. IMMEDIATELY GLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE 51TE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE. 17. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0" CLEAR ZONE OF ALL STORM DRAIN PIPE, 5TRUGTURE5, OR FACILITIES. 18. SEEPAGE BEDS AND OTHER STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE GON5TRUGTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. IG. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 1 1 2 1 3 I 4 1 5 II LANDSCAPE LEGEND EXISTING TREES TO REMAIN PLANTS TO BE INSTALLED WROUGHT IRON FENCE IN CONCRETE MOW STRIP CEDAR FENCE AS DETAILED -- -- PROPERTY LINE (VERIFY) —x—x—x—x—x—x—x—x— EXISTING FENCE VERTICAL GURBIND LOCATION " B AND GUTTER LOCATION IRE JOINT (TYPICAL) ANSION JOINT (TYPICAL) ,E551BLE RAMP LOCATION WITH EGTABLE WARNING SURFACE I VLY I CONCRETE FLATWORK QUANTITY PLANT IDENTIFICATION KEY a SION LOCATION- ALL SION POLES LOCATED IN TURF AREAS TO RECEIVE CONCRETE MOW5TRIP5- SEE DETAIL S1 51TE SIGNAGE IDENTIFICATION =-0 LIGHT POLE WITHOUT CONCRETE APRON BARK MULCH AND TOP501L AS SPECIFIED FESCUE TURF 6 7 8 9 10 11 PLANT SCHEDULE RIGINAL SURVEY ON EILE AT IDAHO SURVEY GROUP P.C. I QTY. KEY BOTANICAL NAME COMMON NAME SIZE CLASS DECIDUOUS SHADE TREES 8 AG Acer compestre 'Evelyn' Queen Elizabeth Maple 2" GAL. BffB II 22 6T 61edit5ia triacanthos inermis '5hodemoster' Shodemaster Hone locust 2" GAL, Bff B III ORNAMENTAL FLOWERING TREES 8 PG Prunus cerasifero 'Thundercloud' Thunder Cloud Plum 2" GAL. B$B I SHRUBS/PERENNIALS/ORNAMENTAL GRASSES 50 PO Physocorpus opullfollus 'Seward' Summer Wine Ninebark #5 85 50 Salvia officinalis 'Purpurescens' Purple Sage #1 43 5Z 5pirea x 'Zelda' Solar Flare 5pirea #5 46 TO Thula occidentalis 'Emerald' Emerald Green Arborvitae #5 2G WF Dark Horse Wel ela 12 CALLOUT LEGEND O6-0" HEIGHT WROUGHT IRON FENCE, SEE DETAIL 4/L1.5. AT PROPERTY LINE LOCATIONS THE FENCE 15 SHOWN 0'-6" OFF OF PROPERTY LINE FOR 6RAPHIG CLARITY. Q5-0" WIDTH WROU6HT IRON GATE SEE DETAIL 5/L1.5. 6-0" HEIGHT WROUGHT IRON FENCE IN 3 CONCRETE MOWSTRIP, SEE DETAILS 4 AND 6/L1.5. AT PROPERTY LINE LOCATIONS THE FENCE 15 SHOWN 0'-6" OFF OF PROPERTY LINE FOR 6RAPHIG CLARITY. OFIVE MILE GREEK PATHWAY 516N AND POST, SEE DETAIL 7/L1.5. RETAIN AND PROTECT EXISTING Q VEGETATION. OEXISTING IRRIGATION PUMP HOUSE. 13 14 PROJECT INFORMATION TOTAL OPEN/COMMON SPACE: 47,750 S.F. PERIMETER LAN05GAPIN6 TREE REQUIREMENTS: NORTH BOUNDARY: 436LIN. FT. REQUIRED- I TREE PER 35; 12 PROVIDED- 12 SOUTH OF RE51DENGES: 567' LIN. FT. REQU I RED- I TREE PER 30'; 16 PROVIDED- 17 NUMBER OF STREET TREES: 12 TOTAL NUMBER OF TREES: 35 TOTAL NUMBER OF TREE SPECIES: 3 TOTAL NUMBER OF SHRUBS/PERENNIALS/GRASSES: 206 SIGNAGE LEGEND mmMr CAEEI(PAiHWAY 1 10"x 24" 15 16 y L 10 O C 0 r Cr 75 C N Z u� l D ,^ N C U p'nj op rW O W E: E'� a ,'o(� �m aU7 op.5 cW �a�U,=E �c0 �E LU u�i.4L'Z �aoN `oU LU w a �-0 0 u Z C 'j C O� C C UJWC� � J mL (D m .. 9 v 9 3 1L a CD p Copyright © 2017 All rights reserved. Reproduction or use in any form or by any means without written permission of Breckon Land Design, Inc. is unlawful and subject to criminal prosecution. 0 a0cW W W ywGa'O �� g0a F yVv'W=W n Gov p Mau' a�W W JQox 7W 4z>. j U REVISIONS Date Description 3-27-17 Plan Revisions 4/19/17 City Comments 5/3/17 QLPE Comments 6/7/17 ACHD Comments PROJECT NO.: 15014 DRAWN BY: LP, BS, AJ, TC CHECKED BY: JB, MD DATE: 08-18-16 SHEET NUMBER L1.1 Z O U U) Z O U O U- 0 W 0 0 in I..L L J KEEP &ROUND LINE SAME AS NURSERY LINE REMOVE ANY PLASTIC, BURLAP, NAILS, OR OTHER MATERIALS FROM THE ROOTBALL WHIGH MAY LIMIT ROOT GROWTH CONSTRUCT 2" EARTH BERM TO FORM A WATER RETENTION BASIN, FILL BERM WITH MULCH, AS SPECIFIED MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER GROWN5 OF PLANTS PROVIDE DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL BACKFILL WITH APPROVED TOPSOIL AND SO 1 L AMENDMENTS, AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER EACH LAYER, DO NOT TAMP OR OVER COMPACT. 114 y I C. CONSTRUCT 6" MOUND OF TOPSOIL I. WATER SHRUB TWIGE WITHIN FIRST 24 HOURS. 2. APPLY SPECIFIED PRE -EMERGENT PER MANUFAGTURER'S RECOMMENDATIONS TO ALL &ROUNOGOVER BEDS. �SHRUB PLANTING PLAN V___ _ NOT TO SGALC A = LENGTH, AS SPECIFIED OR PER PLANT SCHEDULE B = 85% OF X FINISH GRADE PER PLANS EDGING, PER PLANS AND DETAILS &ROUNDGOVER PLANTING PER PLANTING PLAN MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER GROWNS OF PLANTS SPLIT ALL ROOT BOUND ROOTS WITH 3 EQUAL SPACED VERTICAL GUTS. TILL SOIL TO A DEPTH OF 12", BAGKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS, AS SPECIFIED. DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL NOTES: �5UB&RADE I. ALL 6ROUNDGOVER PLANTS TO BE PLANTED ON CENTER AND IN A TRIANGULAR PATTERN. 2. APPLY SPECIFIED PRE -EMERGENT PER MANUFAGTURER'5 RECOMMENDATIONS TO ALL 6ROUNDGOVER BEDS. PERENNIA�LAN D GROUNDCOVER 0 NOTE: L PLANTING 2"X2" HOLLOW STEEL SUPPORT PICKET WHEN PRESENT: BUD SUPPORT PICKET 6O.G. TOP OF STOCK. POINT (A MINOR ROOT FLARE/COLLAR (SWELLING AT �" HOLLOW STEEL CROOK IN THE TRUNK SOIL LINE WHERE STEM TISSUE 4C' SOLID BAR RING JUST ABOVE THE TRANSITIONS INTO ROOT TISSUE) TO RESPONSIBLE SOIL LINE) TO BE HOLLOW SITOLTAL BOLT, STRIKER PLATE, 5ELF-LATGHIN6 BE AT SOIL LINE. APPROXIMATELY I Y2" BOLT AND KEY LOCKED BOTH SIDES, Z Z PREVAILING WIND ABOVE THE SOIL ROOT PROBE DIRECTION DRAWINGS TO AMERICAN FENGIN6 PRODUCTS. LINE F BE REVIEWED w I_ o N SOIL LINE 'N HINGES " HOLLOW STEEL N REMOVE DEAD/DAMAGED BRANCHES LANDSCAPE a N AND PRUNE TO INTERNATIONAL ARCHITECT SOCIETY OF ARBORICULTURE STANDARDS; IMPROPERLY PRUNED TREES (AS DETERMINED BY THE INSTALLATION. _ Q a LANDSGAPE ARCHITECT) SHALL BE I. TOP OF POST L2 HIGHEST ROOT SHALL tin REMOVED AND REPLACED. DO NOT F& o BE 2" MAXIMUM REMOVE MAIN LEADERII BELOW SOIL LINE. PAINTED W/ N U UTILIZE SOIL/ROOTRUBBER CINCH TIE E ELE6TSTATIC PROBE AROUND. HOLLOW STEEL a TRUNK (APPROX 1"-2" 2"x 2" WOOD STAKE (LENGTH AS AWAY FROM TRUNK) REQUIRED) -DO NOT PENETRATE COLOR AS 6. 6' 0. C. TO LOCATE HIGHEST z ROOTBALL. SEE NOTE I. SET STAKES DIRECTED BY ROOTS. �o CD PARALLEL TO PREVAILING WIND. w Of U J U REMOVE TREE WRAP TRUNK WROUGHT -6 o PROTECTION, AFTER INSTALLATION - z bi Q CONSTRUCT 2" EARTH BERM AT E06E C O LO m OF ROOTBALL, FILL TREE RING W/ Ln o MULCH, AS SPECIFIED. p o REMOVE BURLAP, co TWINE, AND WIRE 3" THICK MULCH LAYER, KEEP MULCH BASKET FROM TOP 3" AWAY FROM TRUNK. OF ROOTBALL, FINISH GRADE REMOVE ALL NAILS, o TIES, AND PLASTIC V)/j�/jam///j�// //\ //\/////// // / / COMMERCIAL SLOW RELEASE FROM ROOTBALL. IF<w FERTILIZER TABLETS CIL SYNTHETIC BURLAP IS a — N // / UTILIZED TO WRAP - _� =_ __ =1 SIDES OF HOLE ROUGH 4 UNEVEN THE ROOTBALL, IT / SHALL BE =III—! BAGKFILL WITH APPROVED TOPSOIL COMPLETELY i, III AND SOIL AMENDMENTS AS C ° REMOVED. ONLY -I 1=1 = =� SPECIFIED. BAGKFILL IN 6" LIFTS, BIODEGRADABLE WIDTH WIDTH WIDTH WIDTH WIDTH WATER EACH LAYER, TAMP 77 77 BURLAP SHALL BE OF BALL OF BALL OF BALL OF BALL OF BALL LIGHTLY AS REQUIRED, BAGKFILL LEFT ON THE BOTTOM SOIL EVEN W/ TOP OF ROOTBALL, 5' MIN. DIA. �r OF THE ROOTBALL. DO NOT OVER GOMPAGT!I o TREE RING LO SET ROOTBALL ON NATIVE, NOTES: UNDISTURBED SOIL I. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO Q INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY B PERIOD OR I YEAR AFTER SUBSTANTIAL COMPLETION WHIGHEVER IS GREATER. ALL STAKING SHALL BE REMOVED v AT THE END OF THE WARRANTY PERIOD. B o 2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE `o LANDSCAPE ARCHITECT BEFORE PROGEEDIN6. 3. LANDSGAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT MATERIAL. cn 4. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR F16URE EIGHT TYIN6 METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. 5. WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 6. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT 0 IMMEDIATELY. -7. FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER (DEEPROOT #24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. ALL TREE INSTALLATIONS SHALL CONFORM TO ALL A6ENGY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY N PRIOR TO ANY INSTALLATIONS. A DECIDUOUS TREE PLANTING 0 L 3 NOT To SC LE _L 1 2 3 4 5 6 7 0 NOTE: 2"X2" TUBULAR STEEL 2"X2" HOLLOW STEEL SUPPORT PICKET FOR GATE AND TERMINAL POST GAP SUPPORT PICKET 6O.G. TOP OF STOCK. CONTRACTORS ARE �" HOLLOW STEEL PLAN VIEW 4C' SOLID BAR RING RESPONSIBLE Z11111twZ11110 HOLLOW SITOLTAL BOLT, STRIKER PLATE, 5ELF-LATGHIN6 FOR SHOP BOLT AND KEY LOCKED BOTH SIDES, Z Z co DRAWINGS TO AMERICAN FENGIN6 PRODUCTS. SOLID BAR RING 1 BE REVIEWED w I_ o N H BY 0 J HINGES " HOLLOW STEEL F& LANDSCAPE a N ARCHITECT BEFORE . o NOTE: INSTALLATION. _ I. TOP OF POST WROU6HY I RON F& TO BE GUT 1/2" GATE TO BE PAINTED W/ N (I)4" HORIZONTAL BELOW TOP OF ELE6TSTATIC HOLLOW STEEL SIGN. STATIC PAINT - COLOR AS 6. 6' 0. C. CONCRETE FOOTING DIRECTED BY OWNER. WROUGHT IRON FENCE - (04' HORIZONTAL HOLLOW STEEL 5' O.C. CONCRETE SIDEWALK NOTE: 6 CONCRETE FOOTING CONTRACTORS ARE RESPONSIBLE FOR SHOP DRAWIN65 TO BE REVIEWED BY LANDSCAPE ARCHITECT BEFORE INSTALLATION. WROU&HY IRON &ATE TO BE PAINTED W/ELECTO STATIC PAINT - COLOR AS DIRECTED BY OWNER. WROUGHT IRON 5 Scale: 1/4"= -0" fol PEDESTRIAN GATE PLAN VIEW CONCRETE MOW5TRIP CONCRETE FOOTING SCORE JOINT, AT EACH POST FENCE POST FENCE POST, SET POST PRIOR TO INSTALLATION OF MOW5TRIP CONCRETE MOWSTRIP, PLACE MOW5TRIP PRIOR TO INSTALLATION OF FENCE FABRIC SET FINISH GRADE AS SPECIFIED SET TOP OF POST FOOTING 6" BELOW FINISH 6RADE CONCRETE FOOTING SECTION VIEW ° <~ , °III - COMPACT 5UB6RADE NOTES: — — I. REFER TO LAYOUT PLAN FOR MOW5TRIP LOCATIONS. 2. SCORE JOINTS 0 10' O.G. OR AT EACH POST. 6 FENCE IN MOW STRIP 0 10 11 Seale: 5/4"= 1'-0" 12 N JLi V) SIGN, TYPICAL z�� UJ 0 o�z o I o \_ RIGINAL SURVEY ON EILE AT IDAHO SURVEY GROUP P.C. 2" x 2" x 10' (MINIMUM) SQUARE GALVANIZED PERFORATED SIGN POST (12 GAUGE MIN. WALL THICKNESS) 3/a" x 36" CADMIUM PLATED HEX HEAD BOLT WITH FLAT LOCK WASHER AND NUT -FINISH GRADE PER PLANS -SLOPE TOP OF CONCRETE TO ENSURE POSITIVE DRAINAGE AWAY FROM SIGN POST -26" x 2Y2" x 15" LON& ANCHOR SLEEVE, NON -PERFORATED (12 GAUGE MIN. WALL THICKNESS) -WRAP ANCHOR SLEEVE AND ANCHOR POST WITH (1) LAYER OF DUCT TAPE - 2Y4" x 2Y4" x 36" L 0 N 6 ANCHOR POST, NON-PERFORTED (12 GAUGE MIN. WALL THIGKNE55) -CONCRETE FOOTING SECTION VIEW SIGN POST AND FOOTING SECTION A—A' 1"x4" CEDAR BOARD 2"x4" CEDAR TOP RAIL 2-3/8" DIA. 16 GAUGE GALVANIZED STEEL POST Seale: CHAMFER PICKET TOP; BY OWNER 1"x4" CEDAR BOARD SPACE 1/2" APART 2"x4" CEDAR TOP RAIL SET 12" BELOW TOP OF POST SIMPSON PIPE GRIP TIES 11i-111 -III' \-2"x4" CEDAR BOTTOM RAIL SET I I-- d II - 12" ABOVE FINISH GRADE o N I� 1111111 a III SET FINISH GRADE AS SPECIFIED I.IIIIIII a d II 2-3/8" 16 GAUGE GALVANIZED 1= POST, SET 8'-0" APART O.G. 1m T! 1 ELEVATION II VIII- _ =111 CONCRETE FOOTING AS 111LIIIli___I11111 `I SPECIFIED !, 6" AGGREGATE BASE NOTE: 44� 2244 COMPACTED 5UB6RADE I. REFER TO PLAN FOR FENCE LOCATION. 2. PANELS OF FENCE TO ALTERNATE SIDES AT EVERY POST. SEE SECTION A -A'. CEDAR FENCE Scale: -`TH OF MULCH AT -ER BEDS APPROVED TOPSOIL AND SOIL FINISH 6RADE, AMENDMENTS A5 5PEGIFIED PER PLANS \-GUT EDGE PLANTER BED CUT EDGE 9 (TYPICAL AT TREES IN TURF AREAS) 13 14 15 NOT TO SCALE 16 M y N 10 co (D = U aa,, W W O W optE5m 00(9 30 L)`5 E'� a mUD u=i m aa) op'� =W N C7� =o.rXjU=E i0 �� LU u�i.4L'Za ,ODN `oU 2 N O- Ic -O -0 o U) Z CD = Oto � C C -O UJWCD J mL (D m • • • • • • 3 uL a CD CD Copyright © 2017 All rights reserved. Reproduction or use in any form or by any means without written permission of Breckon Land Design, Inc. is unlawful and subject to criminal prosecution. u y .-a --Ux rn W ` 2womonj EU W20 D*2*mWW NG0Q40M U) MZ2 JQ�V7W g_>.Wi 2 0 REVISIONS r , Date Description V 3-27-17 Plan Revisions 4/19/17 City Comments 5/3/17 QLPE Comments O 6/7/17 ACHD Comments LL PROJECT NO.: 15014 0 DRAWN BY: w LP, BS, AJ, TC CHECKED BY: O JB, MD N DATE: Of 08-18-16 in I..L SHEET NUMBER L1.5 2"X2" HOLLOW STEEL SUPPORT PICKET FOR GATE AND TERMINAL POST GAP TOP OF STOCK. �" HOLLOW STEEL (2)-I" HORIZONTAL HOLLOW STEEL SOLID BAR RING "AMERISTAR" LOCK SYSTEM WITH DEAD BOLT, STRIKER PLATE, 5ELF-LATGHIN6 o BOLT AND KEY LOCKED BOTH SIDES, Z Z MODEL # HB50CI. ADA APPROVED AMERICAN FENGIN6 PRODUCTS. Z 1-500-321-5-724 OR I -888-333-3422. Q I_ o TWO - SELF-CLOSING GATE HINGES F& N d (04' HORIZONTAL HOLLOW STEEL 5' O.C. CONCRETE SIDEWALK NOTE: 6 CONCRETE FOOTING CONTRACTORS ARE RESPONSIBLE FOR SHOP DRAWIN65 TO BE REVIEWED BY LANDSCAPE ARCHITECT BEFORE INSTALLATION. WROU&HY IRON &ATE TO BE PAINTED W/ELECTO STATIC PAINT - COLOR AS DIRECTED BY OWNER. WROUGHT IRON 5 Scale: 1/4"= -0" fol PEDESTRIAN GATE PLAN VIEW CONCRETE MOW5TRIP CONCRETE FOOTING SCORE JOINT, AT EACH POST FENCE POST FENCE POST, SET POST PRIOR TO INSTALLATION OF MOW5TRIP CONCRETE MOWSTRIP, PLACE MOW5TRIP PRIOR TO INSTALLATION OF FENCE FABRIC SET FINISH GRADE AS SPECIFIED SET TOP OF POST FOOTING 6" BELOW FINISH 6RADE CONCRETE FOOTING SECTION VIEW ° <~ , °III - COMPACT 5UB6RADE NOTES: — — I. REFER TO LAYOUT PLAN FOR MOW5TRIP LOCATIONS. 2. SCORE JOINTS 0 10' O.G. OR AT EACH POST. 6 FENCE IN MOW STRIP 0 10 11 Seale: 5/4"= 1'-0" 12 N JLi V) SIGN, TYPICAL z�� UJ 0 o�z o I o \_ RIGINAL SURVEY ON EILE AT IDAHO SURVEY GROUP P.C. 2" x 2" x 10' (MINIMUM) SQUARE GALVANIZED PERFORATED SIGN POST (12 GAUGE MIN. WALL THICKNESS) 3/a" x 36" CADMIUM PLATED HEX HEAD BOLT WITH FLAT LOCK WASHER AND NUT -FINISH GRADE PER PLANS -SLOPE TOP OF CONCRETE TO ENSURE POSITIVE DRAINAGE AWAY FROM SIGN POST -26" x 2Y2" x 15" LON& ANCHOR SLEEVE, NON -PERFORATED (12 GAUGE MIN. WALL THICKNESS) -WRAP ANCHOR SLEEVE AND ANCHOR POST WITH (1) LAYER OF DUCT TAPE - 2Y4" x 2Y4" x 36" L 0 N 6 ANCHOR POST, NON-PERFORTED (12 GAUGE MIN. WALL THIGKNE55) -CONCRETE FOOTING SECTION VIEW SIGN POST AND FOOTING SECTION A—A' 1"x4" CEDAR BOARD 2"x4" CEDAR TOP RAIL 2-3/8" DIA. 16 GAUGE GALVANIZED STEEL POST Seale: CHAMFER PICKET TOP; BY OWNER 1"x4" CEDAR BOARD SPACE 1/2" APART 2"x4" CEDAR TOP RAIL SET 12" BELOW TOP OF POST SIMPSON PIPE GRIP TIES 11i-111 -III' \-2"x4" CEDAR BOTTOM RAIL SET I I-- d II - 12" ABOVE FINISH GRADE o N I� 1111111 a III SET FINISH GRADE AS SPECIFIED I.IIIIIII a d II 2-3/8" 16 GAUGE GALVANIZED 1= POST, SET 8'-0" APART O.G. 1m T! 1 ELEVATION II VIII- _ =111 CONCRETE FOOTING AS 111LIIIli___I11111 `I SPECIFIED !, 6" AGGREGATE BASE NOTE: 44� 2244 COMPACTED 5UB6RADE I. REFER TO PLAN FOR FENCE LOCATION. 2. PANELS OF FENCE TO ALTERNATE SIDES AT EVERY POST. SEE SECTION A -A'. CEDAR FENCE Scale: -`TH OF MULCH AT -ER BEDS APPROVED TOPSOIL AND SOIL FINISH 6RADE, AMENDMENTS A5 5PEGIFIED PER PLANS \-GUT EDGE PLANTER BED CUT EDGE 9 (TYPICAL AT TREES IN TURF AREAS) 13 14 15 NOT TO SCALE 16 M y N 10 co (D = U aa,, W W O W optE5m 00(9 30 L)`5 E'� a mUD u=i m aa) op'� =W N C7� =o.rXjU=E i0 �� LU u�i.4L'Za ,ODN `oU 2 N O- Ic -O -0 o U) Z CD = Oto � C C -O UJWCD J mL (D m • • • • • • 3 uL a CD CD Copyright © 2017 All rights reserved. Reproduction or use in any form or by any means without written permission of Breckon Land Design, Inc. is unlawful and subject to criminal prosecution. u y .-a --Ux rn W ` 2womonj EU W20 D*2*mWW NG0Q40M U) MZ2 JQ�V7W g_>.Wi 2 0 REVISIONS r , Date Description V 3-27-17 Plan Revisions 4/19/17 City Comments 5/3/17 QLPE Comments O 6/7/17 ACHD Comments LL PROJECT NO.: 15014 0 DRAWN BY: w LP, BS, AJ, TC CHECKED BY: O JB, MD N DATE: Of 08-18-16 in I..L SHEET NUMBER L1.5