Exterior+ElevationsA. GENERAL NOTES APPLY TO ALL DRAWING SETS.
B. RE: SHEET A700 FOR DOOR TYPES & SCHEDULE.
C. RE: SHEET A701 FOR WINDOW TYPES.
D. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
NOTIFY ARCHITECT IMMEDIATELY IF ANY CONFLICTS OR
DISCREPANCIES OCCUR BEFORE PROCEEDING WITH WORK.
E. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT
NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT
LIMIT APPLICATION OF ANY DRAWING OR DETAIL. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE
DETERMINED, CONSULT THE ARCHITECT PRIOR TO
PROCEEDING WITH WORK. IF DESIGN INTENT REMAINS
UNCLEAR THEN PROVIDE MOST EXPENSIVE OPTION IN BID.
F. DIMENSIONS ARE TO GRID LINE OR FACE OF STRUCTURAL
MEMBER UNLESS OTHERWISE NOTED. DOOR & WINDOW
OPENING DIMENSIONS ARE TO ROUGH OPENING OR
CENTERLINE OF OPENING. CONCRETE AND BRICK DIMENSIONS
ARE GIVEN TO THE FACE OF CONCRETE OR MASONRY AND TO
THE FACE OF ROUGH OPENINGS.
G. UNLESS NOTED OTHERWISE, USE BASF MASTERSEAL NP 150
FOR SEALANT AT ABOVE GRADE EXTERIOR JOINTS.
COORDINATE COLOR W/ ARCHITECT. FOR BELOW GRADE
APPLICATIONS USE DE NEEF SWELLSEAL WA.
H. INSTALL FENESTRATION PRODUCTS SUCH AS, EXTERIOR
WINDOWS, DOORS AND SKYLIGHTS, PER GUIDELINES
ESTABLISHED IN ASTM E 2112-01. REFERENCE GUIDE FOR
INSTALLATION DETAILS AND TECHNIQUES FOR WATER
PROOFING AND WEATHER BARRIER INSTALLATION.
GENERAL NOTES EXTERIOR
ELEVATIONS:
1ST FLOOR
0' - 0"
LOWER ROOF
11' - 4"
ABDEF
UPPER ROOF
19' - 0"
MAX HEIGHT
22' - 0"
C1
A310
2
A320
5
A320
6
A320
2
A310
T.O. COPING
6' - 0"
1ST FLOOR
0' - 0"
LOWER ROOF
11' - 4"
A B D E F
UPPER ROOF
19' - 0"
MAX HEIGHT
22' - 0"
C 1
A310
3
A320
8
A320
2
A310
T.O. COPING
6' - 0"
1ST FLOOR
0' - 0"
LOWER ROOF
11' - 4"
123456
UPPER ROOF
19' - 0"
MAX HEIGHT
22' - 0"
7 5
A310
1
A320
4
A320
3
A310
4
A310
6
A310
T.O. COPING
6' - 0"
1ST FLOOR
0' - 0"
LOWER ROOF
11' - 4"
1 2 3 4 5 6
UPPER ROOF
19' - 0"
MAX HEIGHT
22' - 0"
75
A310
4
A320
7
A320
3
A310
4
A310
6
A310
T.O. COPING
6' - 0"
RIGID INSULATION (SECTION)
ACOUSTIC/THERMAL
INSULATION
(SECTION)
BRICK
GRANULAR FILL
CONCRETE MASONRY UNITS
STUD WALL (PLAN & SECTION)
EXISTING WALL TO REMAIN
(PLAN & SECTION)
DEMO WALL (PLAN & SECTION)
STEEL (SECTION)
ALUMINUM (SECTION)
WOOD - FINISH (SECTION)
LUMBER - FINISH (SECTION)
MATERIAL LEGEND:
CONCRETE (SECTION)
DIMENSIONAL LUMBER
CONTINUOUS (SECTION)
DIMENSIONAL LUMBER
BLOCKING (SECTION)
EARTHWORK (SECTION)
PROJECT DATE
ARCHITECT:
PROJECT PHASE
COLE ARCHITECTS | 1008 W Main St
Boise, ID 83702 | (208) 345 -1800
colearchitects.net
CONSULTANT:
STAMP:
SHEET NUMBER:
REVISIONS:
PROJECT INFORMATION:
NOT FOR
CONSTRUCTION
SHEET NAME:
A300
OCTOBER 05, 2018
PROJECT # | 18 - 019
CZC SUBMITTAL
EXTERIOR ELEVATIONS
ICON CREDIT UNION 10
MILE BRANCH
N. TEN MILE RD. MERIDIAN ID, 83646
1/8" = 1'-0" 4 EAST ELEVATION
1/8" = 1'-0" 3 WEST ELEVATION
1/8" = 1'-0" 2 NORTH ELEVATION
1/8" = 1'-0" 1 SOUTH ELEVATION
MARK DATE DESCRIPTION