Loading...
A1-0a Site Plan5.0 47.5 3.5 5.0 20.0 36.0 20.0 7.0 5.0 8.2 55.5 229.0 45.3 29.0 35 . 0 LA N D S C A P E BU F F E R 1. 0 5. 8 42 . 7 7. 5 20 . 0 36 . 0 20 . 0 8. 0 8. 8 24 . 0 18 . 7 8.0 5.99.0 6.0 5.2 6.0 4.0 15.0 4.0 15.0 50.5 21 . 0 13 7 . 4 4.0 15 . 0 4 . 0 15 . 0 25.5 36.0 55.7 36.0 35.0 LANDSCAPE BUFFER 18. 0 41.3 36.0 5. 0 3 6 . 0 3 0 . 0 2 4 . 4 1 5 . 0 1 0 . 0 10.0 6.0 5. 0 6.0 1 4 . 0 12.0 4.4 15.9 19.1 R 1 5 . 0 R15.0 18.0 S0 0 ° 0 0 ' 0 0 " E - 2 8 8 . 0 ' 111 . 7 1 ' C13 S 4 4 ° 5 9 ' 5 7 " E - 7 0 . 7 0 ' S0 0 ° 0 0 ' 0 0 " E - 1 4 7 . 6 0 ' N90°00'00"W - 217.57' N89°38'43"W - 157.20'N89°38'43"W - 172.62' N48°26'55"W - 38.79' N0 2 ° 5 6 ' 1 6 " W - 1 4 2 . 1 3 ' 32 . 0 6 ' 6. 0 12 . 0 52 . 7 7. 5 2. 0 21.8 26 . 1 11.3 92 . 1 2 1 . 2 124.4 12 . 0 R 2 0 . 0 R12. 0 R 5 . 0 4.0 3. 8 22.2 R15 . 0 R 5 . 0 R 5 . 0 1 6 . 2 8 . 3 R3.0 R3. 0 24.4 24.2 14.910.0R5.5 26. 8 8.3 8. 0 6.1 R 3 0 . 0 R20.0 7 3 . 0 2. 0 R5. 0 7. 9 R1 5 . 0 R15. 0 16.5 18.0 R 2 0 . 0 R20 . 0 R3. 0 R5. 0 18 . 4 16. 2 1. 9 2.0 R3.0 14.9 31 . 9 R30 . 0 R7.0 R 3 0 . 5 13.0 R 5 . 0 R 1 5 . 0 7. 5 16.2 R1.5 7.0 12 . 7 R5.0 R1 5 . 0 0.6 R1 5 . 0 R15.0 1.5 1.5 12.1 11.6 11.6 12.1 29 . 5 15 . 0 7. 5 7. 5 4. 4 6. 5 1. 5 1. 5 1.5 1.5 0. 8 3.0 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 10.4 15 . 4 17.5 6.5 19.3 35 . 9 94.920 . 9 11.9 44 . 4 15.5 A3 A7.1 A3 A1.0c A2 A4.1 1 1 2 2 2 3 3 3 3 3 4 4 4 4 55 6 7 7 7 7 8 8 8 8 8 8 9 10 10 11 12 6 13 13 13 14 date drawn job no. sheet number: checked sheet title: THESE DOCUMENTS HAVE BEEN PRODUCED AS AN INSTRUMENT OF SERVICE AND ARE INTENDED SOLELY FOR THE PURPOSE OF CONSTRUCTING, USING AND MAINTAINING THE PROJECT. HOWA DESIGN, INC., AS THE ARCHITECT OF RECORD FOR THE PROJECT RETAINS OWNERSHIP OF THESE DOCUMENTS. ANY USE OF THESE DOCUMENTS OR USE OF THIS DESIGN, IDEAS OR CONCEPTS DESCRIBED HEREIN IN WHOLE OR PART BY ANY MEANS WHATSOEVER IS STRICTLY PROHIBITED EXCEPT BY WRITTEN CONSENT OF HOWA DESIGN, INC. REPRODUCTION OF THIS DOCUMENT IS STRICTLY PROHIBITED EXCEPT BY WRITTEN CONSENT OF HOWA DESIGN, INC. COPYRIGHT 2018 HOWA DESIGN, INC. 11 9 2 8 W . N E T H E R L A N D D R I V E BO I S E , I D A H O 8 3 7 0 9 PH . ( 2 0 8 ) 8 4 1 - 4 5 2 4 issued for 54321 A B C D A B C D 54321 revisions: stamp RO C K E T E X P R E S S C A R W A S H ME R I D I A N , I D A H O 17 1 7 W . I S L A N D G R E E N D R I V E ME R I D I A N , I D A H O 8 3 6 4 6 1718-01 04/18/2018 JEH JEH PERMIT HORIZONTAL CONTROL SITE PLAN A1.0aSCALE: HORIZONTAL CONTROL PLAN 1:20 NORTH 1.CONCRETE ACCESS PER ACHD STANDARD DETAILS. 2.NEW CURB, GUTTER AND SIDEWALK AT THIS BOUNDARY. 3.EXISTING CURB, GUTTER AND SIDEWALK AT THIS BOUNDARY. 4.ADA CONCRETE SIDEWALK RAMP PER ACHD STANDARD DETAILS. 5.ADA RAMP WITH MAXIMUM 1:12 SLOPE. 6.PV CANOPY STRUCTURE TWILL BE PROVIDED AS A DEFERRED SUBMITTAL. AT THAT TIME, SEE STRUCTURAL AND ELECTRICAL DRAWINGS AND SUPPLEMENTAL INSTALLATION LITERATURE PROVIDED BY PV CANOPY VENDOR. 7.TYPICAL 2' Ø x 6' LENGTH CONCRETE REINFORCED SONOTUBES FOR MOUNTING OF VACUUM ARCH STANCHIONS. SONOTUBES TO EXTEND 2" ABOVE ADJACENT PAVEMENT AND 70" BELOW GRADE. PROVIDE #3 REBAR CAGE AT 8" O.C. EACH WAY TOP TO BOTTOM. CONDUIT FOR ARCHES SHALL EXTEND AT CENTER OF SONOTUBE. PRIOR TO FABRICATION, CONTRACTOR SHALL RECEIVE OWNER PROVIDED TEMPLATE FOR PLACEMENT OF 1" J-BOLTS. REFER TO VACUTECH DRAWINGS FOR SONOTUBE FABRICATION. 8.STRIPING PAINT, TYPICAL. 9.BIKE RACK MANUFACTURED FOR A MINIMUM OF (3) BIKES. ANCHOR TO SIDEWALK PER MANUFACTURE'S PUBLISHED INSTRUCTIONS. 10.VACUUM PRODUCER. 11.MAT CLEANERS (6 UNITS). 12.KIOSK FOR EMPLOYEE SHELTER PROVIDED BY OWNER, OFF-LOADED, SET IN PLACE AND INSTALLED BY CONTRACTOR. DIVISION 16 CONTRACTOR TO COORDINATE CONNECTION REQUIREMENTS AND CONDUIT STUB-UP LOCATIONS WITH SHOP DRAWINGS TO BE PROVIDED BY OWNER. 13.APPROXIMATE LOCATION OF SIGN. SIGNS REQUIRE A SEPARATE PERMIT. 14.STRIPING TO PROVIDE CLEAR AREA FOR FIRE DEPARTMENT HAMMER-HEAD TURN AROUND SPACE. KEYNOTES # A.CONTRACTOR SHALL REPORT TO ARCHITECT ALL CONDITIONS WHICH IMPAIR AND / OR PREVENT THE PROPER EXECUTION OF THIS WORK PRIOR TO BEGINNING WORK. B.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS ON THE JOB SITE AND SHALL NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING WORK. REFER CLOSELY TO BUILDING LAYOUT DRAWINGS IN RELATION TO SITE LAYOUT ITEMS. CONTRACTOR TO VERIFY LISTED DIMENSIONS PRIOR TO CONSTRUCTION. C.ALL CHANGES REQUIRE PRIOR, WRITTEN APPROVAL BY ARCHITECT. D.ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO APPLICABLE SPECIFICATIONS OF THE CITY OF MERIDIAN, ACHD, AND OTHER APPROPRIATE AGENCIES. E.CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COSTS INCURRED DUE TO DAMAGE AND TAKE REPLACEMENT OF SAID UTILITIES. LOCATION OF EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ACTUAL CONSTRUCTION. F.CONTRACTOR SHALL NOT WILLFULLY PROCEED WITH CONSTRUCTION AS DESIGNED WHEN IT IS OBVIOUS THAT UNKNOWN OBSTRUCTIONS, AREA DISCREPANCIES AND/OR GRADE DIFFERENCES EXIST THAT MAY NOT HAVE BEEN KNOWN DURING DESIGN. SUCH CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION. G.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COORDINATION WITH SUBCONTRACTORS AS REQUIRED TO ACCOMPLISH ALL CONSTRUCTION OPERATIONS. ALL PIPING, CONDUIT, SLEEVES, ETC., SHALL BE SET IN PLACE PRIOR TO INSTALLATION OF CONSTRUCTION ITEMS. H.ALL EXISTING IMPROVEMENTS TO REMAIN SHALL BE PROPERLY AND ADEQUATELY PROTECTED FROM DAMAGE DURING CONSTRUCTION OPERATIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RESTORE THE ORIGINAL CONDITION ANY EXISTING ITEMS THAT ARE DAMAGED OR DISTURBED IN ANY WAY. ALL MATERIALS TO BE REUSED OR SALVAGED SHALL BE STORED IN AN AREA DESIGNATED BY THE OWNER FOR THAT PURPOSE. ALL SALVAGED MATERIALS SHALL REMAIN THE PROPERTY OF THE OWNER. I.ALL MATERIALS SPECIFIED TO BE REMOVED SHALL BE DISPOSED OF OFF-SITE PER LOCAL CODES AND REGULATIONS. J.THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING UTILITIES AND IMPROVEMENTS. ANY DAMAGE TO EXISTING FACILITIES OR IMPROVEMENTS RESULTING FROM THE CONTRACTORS OPERATIONS, SHALL BE REPAIRED OR REPLACED AT CONTRACTORS EXPENSE. K.DURING THE COURSE OF THE WORK, THE CONTRACTOR SHALL COORDINATE AND ACCOMMODATE OTHER CONTRACTORS, OWNER'S CONSTRUCTION FORCES, OPERATIONS OF THE OWNER AND LOCAL AND STATE AGENCIES. L.SITE UTILITIES SHALL BE STUBBED 5' FROM BUILDING FACE. TYPICAL UNLESS OTHERWISE NOTED. M.THE CONTRACTOR SHALL NOTIFY THE CITY OF MERIDIAN BUILDING DEPARTMENT AND ACHD BEFORE BEGINNING ANY CONSTRUCTION ACTIVITIES IN THE CITY RIGHT-OF-WAY. ALL RIGHT-OF-WAY IMPROVEMENTS SHALL BE REVIEWED AND AUTHORIZED IN WRITING BY THE CITY RIGHT-OF-WAY COORDINATOR. N.THE LOCATION OF UNDERGROUND UTILITIES ARE SHOWN HORIZONTALLY IN AN APPROXIMATE MANNER ONLY. THE CONTRACTOR SHALL COMPLY WITH LOCAL CODE REQUIREMENTS REGARDING UNDERGROUND FACILITIES DAMAGE PROTECTION. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL ALL EXISTING FACILITIES PRIOR TO COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF FAILURE TO EXACTLY LOCATION AND PRESERVE ANY AND ALL UTILITIES. THE CONTRACTOR SHALL CONTACT THE APPROPRIATE UTILITY COMPANIES OR DIGLINE FOR EXACT LOCATIONS A MINIMUM OF 48 HOURS PRIOR TO DIGGING. O.PRESERVE AND PROTECT ALL FACILITIES AND LANDSCAPING OUTSIDE OF THE PROJECT AREA. P.CONTRACTOR SHALL REFER TO PROJECT SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. Q.ALL DIMENSIONS ARE TO FACE OF CURB, EDGE OF WALK, EDGE OF PAVEMENT, EDGE OF FOUNDATION, FACE OF WALL FRAMING, OR CENTER OF COLUMNS. R.TRANSITION OF CURVES TO OTHER CURVES AND CURVES TO TANGENTS SHALL BE SMOOTH AND CONTINUOUS. S.ALL ACCESSIBLE PARKING STALLS AND SIGNS SHALL CONFORM TO ALL FEDERAL, STATE AND LOCAL REQUIREMENTS FOR ACCESSIBLE PARKING. T.PROVIDE STRIPING WHERE ILLUSTRATED. USE 4" WIDE WHITE TRAFFIC MARKINGS. CONTRACTOR TO REVIEW DIRECTIONAL ARROWS NOT ILLUSTRATED WITH OWNER PRIOR TO BID AND MAINTAIN WRITTEN RECORD OF QUANTITY AND LOCATION OF DIRECTIONAL ARROWS DECIDED. PROVIDE RUSTOLOEUM LATEX PROFESSIONAL TRAFFIC STRIPING PAINT #2593 WHITE OR ARCHITECT APPROVED EQUAL. GENERAL NOTES