Linder Professional Building_Site Plan & EasementE
P
E
P
R
O
W
R
O
W
ROW ROW ROW
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
W W W W W W W W W W W W W W W W W W W W W
SS SS SS SS SS SS SS
S
S
S
S
S
S
S
S
S
S
S
S
SS SS SS SS SS SS SS SS SS SS SS SS SS
S
S
S
S
F
O
F
O
F
O
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
POW POW
P
O
W
POWPOW
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
P
O
W
C
A
B
L
E
C
A
B
L
E
CABLE CABLE CABLE
S
S
P
O
W
D
D
D
D
D
D
W
SD SD
F
O
T
T
T
TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TELFOFOFOFOFOFOFOFOFOFOFOFOGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS
C
A
B
L
E
C
A
B
L
E
CABLE CABLE
GAS GAS
G
A
S
G
A
S
G
A
S
G
A
S
W
NEW HYDRANT
1
0
+
0
0
1
1
+
0
0
12+0012+35
BP: 10+00.00
PI: 11+24.34
E
P
:
1
2
+
3
4
.
8
2
G
A
S
N. PENNGROVE WAY
N
. P
E
N
N
G
R
OVE WAY
M
C
M
I
L
L
A
N
R
O
A
D
LINDER ROAD
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
2
'
'
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
2
'
'
P
I
R
R
W W W W W W W
W
W
W
W
W
S
S
S
S
S
S
S
S
SSSSSSSS S
S
W
W
W
W
W
W
W
W
W
W
SS
S
S
S
S
S
S
W
W
PIRR
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
P
I
R
R
W W
W
W
W
W
W
W
S
S
PIRR PIRR PIRR
S
S
S
S
S
S
P
I
R
R
P
I
R
R
(SCALE IN FEET)
1:30 (22x34 FULL SIZE)30 15 90300
SITE PLAN & DIMENSION PLAN
60' x 95'
5,700 SQ. FT.
60' x 100'
10,000 -12,000 SQ. FT.
TWO STORY BUILDING
60' x 100'
6,000 SQ. FT.
29.59'
30.00'
30.00'
30.00'
135°'
DEVELOPED LOT
25.00'
19.01'
9.00'
MIN
50' x 84'
4,200 SQ. FT.
50' x 66'
3,300 SQ. FT.46' x 82'
3,772 SQ. FT.29.59'
9.00'
MIN
8.68'
4.77'
41.31'
8
8
6.00'
8.33'
29.67'
34.16'
25.41'
18
17
30.21'
23.76'
4.04'
30.18'
30.02'
10.00'
25.00'
24.01'
6.00'
120.50'
5
10.00'
7.00'
7.00'
20.00'
30.00'
10.00'
11
35.42'
8
3
11
31.91'
4.77'10.00'
25.01'25.02'
10.00'
6.09'
5.03'
5
17.41'16.87'16.11'18.88'
RETAINING WALL 34.61'33.60'
6.86'
25.09'
24
25.01'
38.00'25.09'25.01'
10.07'
25.03'
7
10
35.02'
4.77'23.76'
6.12'
25.03'
19.01'
5
11
9.50'
27.59'
27.59'
TRASH ENCLOSURE
TYPE 1, 35' STREET
LIGHT, TYP
5.50'
5.00'
NEW PEDESTRIAN RAMP PER ISPWC SD-712C
TYP
NEW SIDEWALK PER ISPWC SD-709
TYPE 2 STREET LIGHT, TYP
MAX SPACING 220'
19.00'
MIN
8
EXISTING LANDSCAPING CONTAINS
GRASS AND 15 TREES
EXISTING LANDSCAPING
CONTAINS GRASS AND
9 TREES
EXISTING SIDEWALK, TYP
EXISTING FIRE HYDRANT, TYP
EXISTING LANDSCAPING CONTAINS
GRASS AND 8 TREES
April 2018
PL
O
T
T
E
D
B
Y
:
CA
L
E
B
K
E
N
Y
O
N
DA
T
E
P
L
O
T
T
E
D
:
4/
3
/
2
0
1
8
4
:
5
8
:
1
5
P
M
PA
T
H
:
A:
\
A
B
C
O
E
N
G
I
N
E
E
R
I
N
G
\
J
O
B
S
L
A
N
D
E
D
\
1
6
-
4
4
3
3
Z
-
-
L
I
N
D
E
R
P
R
O
F
E
S
S
I
O
N
A
L
P
L
A
Z
A
S
U
B
D
I
V
I
S
I
O
N
(
M
C
C
A
R
T
E
R
M
O
O
R
H
O
U
S
E
)
\
0
0
A
B
C
O
C
A
D
\
1
6
-
4
4
3
3
Z
-
0
3
-
C
S
-
1
0
1
-
A
L
T
E
R
N
A
T
E
F
O
R
C
E
R
T
O
F
O
C
C
.
D
W
G
FILE NUMBER:
SHEET NUMBER:
DESIGNED BY:
DATE
DE
S
C
R
I
P
T
I
O
N
DA
T
E
RE
V
I
S
I
O
N
S
BY
NO
.
DRAWN BY:
AB
C
O
EN
G
I
N
E
E
R
I
N
G
2101 Delta Drive
Nampa, Idaho 83687
Phone (208) 955-8126
N.
L
I
N
D
E
R
R
O
A
D
C. Kenyon
CS-101
ME
R
I
D
I
A
N
,
I
D
A
H
O
SI
T
E
P
L
A
N
MC
C
A
R
T
E
R
M
O
O
R
H
O
U
S
E
,
L
L
C
1 OF 2
AD
A
C
O
U
N
T
Y
LI
N
D
E
R
P
R
O
F
E
S
S
I
O
N
A
L
P
L
A
Z
A
S
U
B
D
I
V
I
S
I
O
N
C. Kenyon
16-4433Z
NOTES
MAJOR CONTOUR LINE
MINOR CONTOUR LINE
CENTER LINE
EDGE OF PAVEMENT
EDGE OF GRAVEL
FENCE LINE
GAS LINE
OVERHEAD POWER LINE
PROPERTY LINE
UTILITY EASEMENT LINE
SEWER LINE
TELEPHONE LINE
WATER LINE
PRESSURE IRRIGATION LINE
CROSS ACCESS EASEMENT LINE
STORM DRAIN LINE
GRADE BREAK LINE
NUMBER OF PARKING SPACES
ASPHALT PAVEMENT
CONCRETE
1.EXISTING TREES WILL REMAIN 20' MIN OUTSIDE OF
CONSTRUCTION AREA AND WILL BE PRESERVED WITH FENCING
WHERE REQUIRED.
2.NO BICYCLE PARKING IS PROVIDED FOR THIS DEVELOPMENT.
3.THE FOLLOWING INFORMAITON IS NOT PROVIDED DUE TO THE
DEVELOPMENT BEING NON RESIDENTIAL
RESIDENTIAL SUBDIVISION TREES.
ACREAGE AND PERCENTAGE FOR COMMON OPEN SPACE
ACREAGE AND PERCENTAGE FOR QUALIFIED OPEN SPACE
4.NO COMMON LOTS WITHIN THE SUBDIVISION.
EP EP
EG EG
X X
GAS GAS
OHP
SS SS
TEL TEL
W W
PIRR PIRR
CALL BEFORE YOU DIG!
1.THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN
ARE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALL UTILITY
COMPANIES OF THE CONSTRUCTION SCHEDULE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE
CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE
WHICH MAY OCCUR BY FAILURE TO EXACTLY LOCATE AND
PROTECT ALL UTILITIES.
2.CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY
EARTH DISTURBING ACTIVITIES ON SITE, AND REQUEST LOCATE OF
UNDERGROUND UTILITIES.
*The 811 logo is a registered trademark of the CGA.
Know what's below.
before you dig.CallR
SD SD
##
DEVELOPER
MCARTER-MOORHOUSE
3536 W. RYDER CUP DRIVE, MERIDIAN ID 83646
208-908-1332
E
P
E
P
R
O
W
R
O
W
ROW ROW ROW
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
N. PENNGROVE WAY
N
. P
E
N
N
G
R
OVE WAY
M
C
M
I
L
L
A
N
R
O
A
D
LINDER ROAD
P
I
R
R
P
I
R
R
PIRR PIRR PIRR
P
I
R
R
P
I
R
R
CROSS ACCESS
EASEMENT
UTILITY EASEMENT
INTERSECT EXISTING
ACCESS EASEMENT
NEW 10' STREET BUFFER ALONG N PENNGROVE WAY
(SCALE IN FEET)
1:30 (22x34 FULL SIZE)30 15 90300
SITE PLAN & EASEMENT LOCATIONS
60' Idaho Power Easement
Inst. No. 99016374
50' Settlers Irr. District
Settlers Canal License
Agreement
Inst. No. 105185815
25' Homeowner's Assocation
Landscape Esmt. #106129395
M
e
r
i
d
i
a
n
C
i
t
y
W
a
t
e
r
&
S
e
w
e
r
E
s
m
t
.
#
2
0
1
7
-
0
6
6
0
4
4
I
n
g
r
e
s
s
-
E
g
r
e
s
s
A
c
c
e
s
s
E
s
m
t
.
#
2
0
1
7
-
0
7
4
0
8
8
U
t
i
l
i
t
y
&
I
n
g
r
e
s
s
/
E
g
r
e
s
s
E
a
s
e
m
e
n
t
I
n
s
t
.
#
2
0
1
5
-
0
5
1
8
0
7
U
t
i
l
i
t
y
&
I
n
g
r
e
s
s
/
E
g
r
e
s
s
E
a
s
e
m
e
n
t
I
n
s
t
.
#
2
0
1
5
-
0
5
1
8
0
7
M
e
r
i
d
i
a
n
C
i
t
y
W
a
t
e
r
E
s
m
t
.
#
1
0
6
1
2
9
3
9
5
M
e
r
i
d
i
a
n
C
i
t
y
S
e
w
e
r
E
s
m
t
.
#
1
0
6
1
2
9
3
9
5
M
e
r
i
d
i
a
n
C
i
t
y
S
e
w
e
r
E
s
m
t
.
#
1
0
6
1
2
9
3
9
5
25' Cross-Access and Meridian
Sewer & Water Easement
#106129395
14.5'
27'
10' Public Utility,
Irrigation and Lot
Drainage Esmt. #106129395
442 LF
April 2018
PL
O
T
T
E
D
B
Y
:
CA
L
E
B
K
E
N
Y
O
N
DA
T
E
P
L
O
T
T
E
D
:
4/
3
/
2
0
1
8
4
:
5
8
:
3
3
P
M
PA
T
H
:
A:
\
A
B
C
O
E
N
G
I
N
E
E
R
I
N
G
\
J
O
B
S
L
A
N
D
E
D
\
1
6
-
4
4
3
3
Z
-
-
L
I
N
D
E
R
P
R
O
F
E
S
S
I
O
N
A
L
P
L
A
Z
A
S
U
B
D
I
V
I
S
I
O
N
(
M
C
C
A
R
T
E
R
M
O
O
R
H
O
U
S
E
)
\
0
0
A
B
C
O
C
A
D
\
1
6
-
4
4
3
3
Z
-
0
3
-
C
S
-
1
0
2
-
A
L
T
E
R
N
A
T
E
F
O
R
C
E
R
T
O
F
O
C
C
.
D
W
G
FILE NUMBER:
SHEET NUMBER:
DESIGNED BY:
DATE
DE
S
C
R
I
P
T
I
O
N
DA
T
E
RE
V
I
S
I
O
N
S
BY
NO
.
DRAWN BY:
AB
C
O
EN
G
I
N
E
E
R
I
N
G
2101 Delta Drive
Nampa, Idaho 83687
Phone (208) 955-8126
N.
L
I
N
D
E
R
R
O
A
D
C. Kenyon
CS-102
ME
R
I
D
I
A
N
,
I
D
A
H
O
SI
T
E
P
L
A
N
MC
C
A
R
T
E
R
M
O
O
R
H
O
U
S
E
,
L
L
C
2 OF 2
AD
A
C
O
U
N
T
Y
LI
N
D
E
R
P
R
O
F
E
S
S
I
O
N
A
L
P
L
A
Z
A
S
U
B
D
I
V
I
S
I
O
N
C. Kenyon
16-4433Z
CALL BEFORE YOU DIG!
1.THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN
ARE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALL UTILITY
COMPANIES OF THE CONSTRUCTION SCHEDULE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE
CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE
WHICH MAY OCCUR BY FAILURE TO EXACTLY LOCATE AND
PROTECT ALL UTILITIES.
2.CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY
EARTH DISTURBING ACTIVITIES ON SITE, AND REQUEST LOCATE OF
UNDERGROUND UTILITIES.
*The 811 logo is a registered trademark of the CGA.
Know what's below.
before you dig.CallR