CC - Staff ReportSeyam East – FP H-2018-0055 PAGE 1
STAFF REPORT
MEETING DATE: June 26, 2018
TO: Mayor & City Council
FROM: Sonya Allen, Associate City Planner
208-884-5533
Bruce Freckleton, Development Services Manager
208-887-2211
SUBJECT: Seyam East - FP (H-2018-0055)
I. APPLICATION SUMMARY
The applicant, Volante Investments, LLLP, has applied for a final plat (FP) consisting of 10 building
lots on 22.98 acres of land in the I-L (Light Industrial) zoning district.
II. STAFF RECOMMENDATION
Staff recommends approval of the Seyam East subdivision final plat based on the analysis provided
below in Section V.
III. PROPOSED MOTION
Approval
I move to approve File Number H-2018-0055 as presented in the staff report for the hearing date of
June 26, 2018, with the following modifications: (Add any proposed modifications.)
Denial
I move to deny File Number H-2018-0055, as presented during the hearing on June 26, 2018, for the
following reasons: (You should state specific reasons for denial.)
Continuance
I move to continue File Number H-2018-0055 to the hearing date of (insert continued hearing date
here) for the following reason(s): (You should state specific reason(s) for continuance.)
IV. APPLICATION AND PROPERTY FACTS
A. Site Address/Location:
The subject property is generally located on the north side of E. Franklin Road, midway between
N. Eagle Rd. and N. Cloverdale Rd., in the south ½ of Section 9, T. 3N., R. 1E.
B. Applicant:
Volante Investments, LLLP
3084 E. Lanark St.
Meridian, ID 83642
C. Owner:
Same as applicant
Seyam East – FP H-2018-0055 PAGE 2
D. Representative:
Kent Brown, Kent Brown Planning Services
3161 E. Springwood Dr.
Meridian, ID 83642
V. STAFF ANALYSIS
The proposed final plat depicts 10 building lots on 22.98 acres of land in the I-L zoning district.
Staff has reviewed the proposed final plat for substantial compliance with the approved preliminary
plat in accord with the requirements listed in UDC 11-6B-3C.2. Because the number of buildable lots
on the proposed final plat is the same as shown on the approved preliminary plat, staff deems the final
plat in substantial compliance with the approved preliminary plat.
VI. SITE SPECIFIC CONDITIONS
1. Applicant shall meet all terms of the approved annexation and preliminary plat (H-2017-0159),
and development agreement (Instrument No. 2018-052342).
2. The applicant shall obtain the City Engineer’s signature on the final plat within two (2) years of
City Council approval of the preliminary plat (by 3/20/2020); or, apply for a time extension in
accord with UDC 11-6B-7.
3. Prior to submittal for the City Engineer’s signature, have the Certificate of Owners and the
accompanying acknowledgement signed and notarized.
4. The final plat prepared by Wellington Land Surveying, stamped on 5/11/18 by Steven C.
Wellington, included in Exhibit C shall be revised as follows:
a. Easement Notes #7, 8 and 10 (pg. 2): Include recorded instrument number.
b. Notes (pg. 2): Re-number note #12; it should be #8.
5. The landscape plan prepared by South Landscape Architecture, dated 11/17/17, included in
Exhibit D is approved as submitted.
6. The facades of structures and portions of the site on Lot 1, Block 1 and Lots 1 and 4, Block 2
adjacent to Franklin Road, an entryway corridor, shall develop in accord with the standards
contained in the City’s Architectural Standards Manual for commercial developments, rather than
industrial developments, because of their location adjacent to an entryway corridor (Franklin
Road. The facades and portions of the site not directly adjacent to Franklin Rd. may develop in
accord with the standards contained in the Architectural Standards Manual for industrial
developments.
7. All fencing installed on the site must comply with the standards listed in UDC 11-3A-6 and 11-
3A-7. If permanent perimeter fencing is not provided along the boundaries of the site, temporary
fencing to contain debris during construction shall be installed prior to release of building
permits.
8. Staff’s failure to cite specific ordinance provisions or conditions from the preliminary plat does
not relieve the Applicant of responsibility for compliance.
9. Additional streetlights are required on all roads to meet the minimum spacing required in drawing
6C of the Meridian Design Standards. Two additional type 1 or davit poles are required on
Franklin Road. Plan requirements can be found in section 6-5 of the Improvement Standards for
Street Lighting at http://www.meridiancity.org/public_works.aspx?id=272
Seyam East – FP H-2018-0055 PAGE 3
10. Applicant to coordinate fire hydrant locations during plan review. Available flow at longest
proposed dead end is 1500 gpm at 20 psi at the main.
VII. GENERAL REQUIREMENTS
1. Sanitary sewer service to this development is available via extension of existing mains adjacent to
the development. The applicant shall install mains to and through this subdivision; applicant shall
coordinate main size and routing with the Public Works Department, and execute standard forms
of easements for any mains that are required to provide service. Minimum cover over sewer
mains is three feet, if cover from top of pipe to sub-grade is less than three feet than alternate
materials shall be used in conformance of City of Meridian Public Works Departments Standard
Specifications.
2. Water service to this site is available via extension of existing mains adjacent to the development.
The applicant shall be responsible to install water mains to and through this development,
coordinate main size and routing with Public Works.
3. All improvements related to public life, safety and health shall be completed prior to occupancy
of the structures. Where approved by the City Engineer, an owner may post a performance surety
for such improvements in order to obtain City Engineer signature on the final plat as set forth in
UDC 11-5C-3B.
4. Upon installation of the landscaping and prior to inspection by Planning Department staff, the
applicant shall provide a written certificate of completion as set forth in UDC 11-3B-14A.
5. A letter of credit or cash surety in the amount of 110% will be required for all incomplete
fencing, landscaping, amenities, pressurized irrigation, prior to signature on the final plat.
6. The City of Meridian requires that the owner post with the City a performance surety in the
amount of 125% of the total construction cost for all incomplete sewer, water infrastructure pri or
to final plat signature. This surety will be verified by a line item cost estimate provided by the
owner to the City. The applicant shall be required to enter into a Development Surety Agreement
with the City of Meridian. The surety can be posted in the form of an irrevocable letter of credit,
cash deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
7. The City of Meridian requires that the owner post to the City a warranty surety in the amount of
20% of the total construction cost for all completed sewer, and water infrastructure for a duration
of two years. This surety amount will be verified by a line item final cost invoicing provided by
the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
8. In the event that an applicant and/or owner cannot complete non-life, non-safety and non-health
improvements, prior to City Engineer signature on the final plat and/or prior to occupancy, a
surety agreement may be approved as set forth in UDC 11-5C-3C.
9. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
10. It shall be the responsibility of the applicant to ensure that all development features comply with
the Americans with Disabilities Act and the Fair Housing Act.
11. Applicant shall be responsible for application and compliance with any Section 404 Permitting
Seyam East – FP H-2018-0055 PAGE 4
that may be required by the Army Corps of Engineers.
12. Developer shall coordinate mailbox locations with the Meridian Post Office.
13. All grading of the site shall be performed in conformance with MCC 11-1-4B.
14. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill, where footing would sit atop fill material.
15. The engineer shall be required to certify that the street centerline elevations are set a minimum of
3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom
elevation of the crawl spaces of homes is at least 1-foot above.
16. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation district
or ACHD. The design engineer shall provide certification that the facilities have been installed in
accordance with the approved design plans. This certification will be required before a certificate
of occupancy is issued for any structures within the project.
17. At the completion of the project, the applicant shall be responsible to submit record drawings per
the City of Meridian AutoCAD standards. These record drawings must be received and approved
prior to the issuance of a certification of occupancy for any structures within the project.
18. Street light plan requirements are listed in section 6-5 of the Improvement Standards for Street
Lighting (http://www.meridiancity.org/public_works.aspx?id=272). All street lights shall be
installed at developer’s expense. Final design shall be submitted as part of the development plan
set for approval, which must include the location of any existing street li ghts. The contractor’s
work and materials shall conform to the ISPWC and the City of Meridian Supplemental
Specifications to the ISPWC. Contact the City of Meridian Transportation and Utility
Coordinator at 898-5500 for information on the locations of existing street lighting.
19. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of
way (include all water services and hydrants). The easement widths shall be 20 -feet wide for a
single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but
rather dedicated outside the plat process using the City of Meridian’s standard forms. The
easement shall be graphically depicted on the plat for reference purposes. Submit an executed
easement (on the form available from Public Works), a legal description prepared by an Idaho
Licensed Professional Land Surveyor, which must include the area of the easement (marked
EXHIBIT A) and an 81/2” x 11” map with bearings and distances (marked EXHIBIT B) for
review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO
NOT RECORD. Add a note to the plat referencing this document. All easements must be
submitted, reviewed, and approved prior to signature of the final plat by the City Engineer.
20. Applicant shall be responsible for application and compliance with and NPDES permitting that
may be required by the Environmental Protection Agency.
21. Any existing domestic well system within this project shall be removed from domestic service per
City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Water Department at
(208)888-5242 for inspections of disconnection of services. Wells may be used for non-domestic
purposes such as landscape irrigation if approved by Idaho Department of Water Resources.
22. Any existing septic systems within this project shall be removed from service per City Ordinance
Section 9-1-4 and 9 4 8. Contact the Central District Health Department for abandonment
procedures and inspections.
23. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water (MCC 9-1-28.C.1). The applicant should be required to use any existing surface
Seyam East – FP H-2018-0055 PAGE 5
or well water for the primary source. If a surface or well source is not available, a single-point
connection to the culinary water system shall be required. If a single -point connection is utilized,
the developer will be responsible for the payment of assessments for the common areas prior to
development plan approval.
24. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be tiled per UDC
11-3A-6. In performing such work, the applicant shall comply with Idaho Code 42-1207 and any
other applicable law or regulation.
V. EXHIIBITS
A. Vicinity Map
B. Approved Preliminary Plat (dated: 10/31/16)
C. Proposed Final Plat (dated: 5/11/18)
D. Proposed Landscape Plan (dated: 11/17/17)
Seyam East – FP H-2018-0055 PAGE 6
Exhibit A – Vicinity/Zoning Map
Seyam East – FP H-2018-0055 PAGE 7
Exhibit B – Approved Preliminary Plat (dated: 10/31/16)
Seyam East – FP H-2018-0055 PAGE 8
Exhibit C – Proposed Final Plat (dated: 5/11/18)
Seyam East – FP H-2018-0055 PAGE 9
Seyam East – FP H-2018-0055 PAGE 10
Exhibit D –Proposed Landscape Plan (dated: 11/17/17)
Seyam East – FP H-2018-0055 PAGE 11
Seyam East – FP H-2018-0055 PAGE 12