Loading...
CC - OM Fountain Feature Olive Tree Fountain Feature Fountain Operations and Maintenance SPURWING SUBDIVISION FOUNTAIN Section 33, T.4N, R. 1W B.M. Meridian, Idaho Fountain Operations and Maintenance System Owner Spurwing Ltd. Partnership 1406 N. Main Street, #205 Meridian, Idaho 83642 Architect Larson Architects, P.A. 210 Murray Street Boise, Idaho 83714 208-376-7502 Engineer Structural Engineering Consultants, LLC Steve Cornwell, P.E. 410 S. Orchard STreet, Suite 116 Boise, Idaho 83705 208-887-7760 Fountain Consultant Custom Pools Steve Chandler 4048 Chinden Blvd Garden City, Idaho 83714 208-345-2792 June 16, 2015 Page 1 Olive Tree Entry Fountain Feature Fountain Operations and Maintenance Table of Contents Fountain Feature Description p. 3 Inspection Frequency p. 4 Maintenance Activity & Safety Information p. 5 Maintenance p. 6 Appendices A. Pertinent Design Drawings p. 7 - 9 B. Example Inspection & Maintenance Logs p. 10 - 12 Page 2 Olive Tree Fountain Feature Fountain Operations and Maintenance Project & Site Description The site is located north of West Chinden Bolevard off of West Balata Court. The entry features are set within the development and located within the ACHD right-of-way. South of the main entry monuments and arch is a circular tiered fountain with landscaping. The fountain will have small spray jets with the water cascading to the lower pool. The fountain will be constructed of cast stone which match the monuments and cast stone ornamental capstones. On both sides of the fountain is a pedestrian sidewalk providing connectivity among the residential proper- ties. 1A-1.0 A-4.0 A-4.0 1 4 5-24-17 AREA SITE PLAN 1 / 16" = 1'-0" 1A-1.0 A-4.0 A-4.0 1 4AREA OF WORK OVERALL SITE PLAN Page 3 Olive Tree Fountain Feature Fountain Operations and Maintenance Inspection Frequency / Scope of Work The Spurwing Home Owners Association must hire a professional Engineer (Structural) to perform the inspections and maintenance of the Fountain Feature. The recommended inspection and maintenance frequencies in this report are based on the recommendation from a Structural Engineer. Depending on many factors, more frequent maintenance may be justified for the entry feature. It shall be the responsib- ility of the HOA to develop a routine maintenance procedures on the actual preform- ance of the fountain. Inspections during the first years of construction may reveal that more frequent inspections and maintenance are necessary, in which case the recom- mended maintenance intervals should be adjusted accordingly. The HOA shall keep on file for eight years of previous inspections and maintenance records completed todate. Records of any and all major maintenance performed on the fountain feature shall be kept on file for the life of the entry feature. After each inspection the report must be reported to ACHD along with the plan of action for any item on the inspection log with five (5) business days of the inspection. If repairs are needed the HOA shall address the problem with 48 hours and repair with 30 days. Fountain Monument Feature The following inspection and maintenance schedule is provided as a guide for the HOA. At a minimum, the provided inspection and maintenance procedure shall be complied with. After the inspection a report of finding shall be prepared and kept on file for records and use during the next inspection. If any deficiencies are discovered a plan of action shall be determined to remedy those areas. Page 4 Olive Tree Fountain Feature Fountain Operations and Maintenance Maintenance Activity Performed Inspect for overall structural stability. Look for anything that doesn’t appear to be performing as intended. 48 Months Verify that plaster coatings are in good condtion and preventing corrosion of strucutral members 48 Months Inspect overall quality of stone veneer and attachment to concrete structure 48 Months Collect a photo record of the structure and any problem that may be found. 48 Months Safety Information The inspector shall be a PE (Strucutural Engineer) and have the proper safety equipment and training prior to conducting any inspections. If the entry feature inspection reveals a safety concern, the HOA may need to modify the site activities to reduce or eliminate the safety risk. The following is a list of safety precautions an inspector should be aware of when conducting inpections. Page 5 Olive Tree Fountain Feature Fountain Operations and Maintenance Maintenance All maintenance work should be done in accordance with OSHA regulations. Maintenance personnel should have the proper safety equipment and training prior to performing any mainte-nance on the entry feature. The following is a list of safety precautions maintenance personnel should be aware of when they perform maintenance on the entry feature. • Operate equipment safety and in accordance with manufacturers specifications. Equipment operators should be aware of site personnel at all time to avoid causing injury to others.• Contact utility companies before excavating a site. Underground utility may be present. cover or clearly mark excavated areas that will remain open. Backfill at the end of the day and mark to alert of the potential risk.• Wear gloves if any mechancial parts or structural components are going to be handled.• Proper containment and cleanup will be performed in the event of spillage of a hazardous or waste material.• Drop cloths will be used when performing maintenance work, such as painting, scraping, or sand blasting. All collected materials will be properly disposed of daily. Appendix A Pertinent Design Drawings Page 6 Olive Tree Fountain Feature Fountain Operations and Maintenance Page 7 WATER STONE LEGENDS - WALL PANEL SPECIAL RADIUSED SHAPE PANEL F-e STONE LEGENDS - WALL PANEL SPECIAL OUTSIDE RADIUSED SHAPE PANEL F-b, CLIP MOUNT 4' - 3 3 / 4 " WATER 2' - 6 " 8" CL STONE LEGENDS - POOL LEDGE BULLARD 3 #15168 F-a SPECIAL RADIUS PLASTER POOL SKIM COAT BY POOL INSTALLER- HIGH & LOW FOUNTAINS CONCRETE 1' - 9 3 / 4 " 6'-0" 10'-3 5/8" 10'-3 5/8" FACE OF CONC FACE OF CONC FACE OF CURB 1' - 3 5 / 8 " 1' - 3 5 / 8 " 1' - 3 5 / 8 " 34" SPACE - CLIP MOUNT RADIUSED PANELS 3/4" 3/4" 3/4" 8" RUBBER WATER SEAL- 10" CONCRETE CURB 1'-6 3/8"CLEAR L 6'-0" STONE LEGENDS - WALL PANEL SPECIAL RADIUSED SHAPEPANEL F-f C STONE LEGENDS - POOL LEDGEBULLARD 3 #15168 F-g SPECIAL RADIUS 6'-0" WATER COURSE WATER COURSE FACE OF CONCRETE FACE OF CONCRETEFACE OF CONCRETE 10'-3 5/8"FACE OF CONCRETE R61' - 0 " R4' - 0 " R61'-0" R 4 ' - 0 " R61'-0" R61' - 0 " R12'-0" LANDSCAPEAREA LANDSCAPEAREA R6'-0"  26 14 CL CL CL CL FOC A R10'-35 8" ELECTRICAL BOXABOVE GRAD 1'-638" CLEAR 1'-638" CLEAR FOUNTAIN PLAN 1/4" = 1'-0" 1 A-4.0 FOUNTAIN SECTION (HALF) 3/4" = 1'-0" 2 A-4.0 FOUNTAIN ELEVATION 3/8" = 1'-0" 3 A-4.0 FOUNTAIN EQUIPMENT SCHEDULE4 A-4.0 Olive Tree Fountian Feature Fountain Operations and Maintenance Page 8 SMALL MONUMENT MODIFIED SHAPE - MOLDING MARSTEN II - #9640 SM-a SMALL MONUMENT PILASTER BASE - MOLDING BELVUE 1 - #15426 SM-a STONE LEGENDS - POOL LEDGE BULLARD 3 #15168 F-a SPECIAL RADIUS 1'-4 3/4" 3" 1'-6" 1'-2" 2 5 / 8 " 4" 1' - 3 5 / 8 " 1 1/4" CONCRETE WALL CONCRETE WALL 26 PIECES - 3/4" CLIP SPACE BETWEEN EA. PIECE FULL CIRCLE 2'-3 1/2" 2'-11 1/2" R 6 ' - 8 " R 5 ' - 2 " 1 ' - 6 " 1'- 6 " CONCRETE WALL CONCRETE WALL STONE LEGENDS - WALL PANEL SPECIAL INSIDE RADIUSED SHAPE PANEL F-e 11 5 / 8 " 1 1/4" CONCRETE WALL STONE LEGENDS - WALL PANEL SPECIAL OUTSIDE RADIUSED SHAPE PANEL F-b CONCRETE WALL STONE LEGENDS - POOL LEDGE BULLARD 3 #15168 F-a SPECIAL RADIUS 14 PIECES - 38" GROUT SPACE BETWEEN EA. PIECE FULL CIRCLE FOUNTAIN SHAPES CONCRETE WALL 2'-8 7/8" 2'-8 1/4" 1 1 / 4 " 1 1 / 4 " 1 ' - 2 " 1'- 2 " 2'-2 7/8" 2'-6 1/4" R 9 ' - 4 5 / 8 " R 1 0 ' - 6 5 / 8 " 2'-5 5/8" 2'-6" 1 1 / 4 " 1 1 / 4 " R 1 0 ' - 4 3 / 8 " R 1 0 ' - 5 5 / 8 " 2'-3 1/8" 2'-3 3/8" 1 1 / 4 " 1 1 / 4 " R 9 ' - 5 5 / 8 " R 9 ' - 6 7 / 8 " 3/ 4 " 3 / 4 " 3/ 4 " INSIDE OUTSIDE OUTSIDE R 6 ' - 0 3 / 4 " R 6 ' - 2 " Olive Tree Fountain Feature Fountain Operations and Maintenance Page 9 Olive Tree Fountain Feature Fountain Operations and Maintenance Appendix B Example Inspection & Maintenance Logs for Fountain Inspection & Maintenance Page 10 Olive Tree Fountain Feature Fountain Operations and Maintenance Inspection Cover Sheet Project Name: ________________________ Date: ________________ Project Address: _______________________ Project Owner: ________________________ Inspector Name: _______________________ Inspector Contact: ______________________ Inspection Comments: Page 11 Olive Tree Fountain Feature Fountain Operations and Maintenance Maintenance Report Form Project Name: ________________________ Date: ________________ Project Address: _______________________ Name of Maintenance Supervisor: _______________________ Date of last Inspection: ______________________ Describe maintenance activities, including type of work, completion dates contractors, time need to complete task and costs: Page 12