Loading...
A2.31_ROOF PLANSL O P E 1/ 4 : 1 2 SL O P E 1/ 4 : 1 2 RI D G E VAL L E Y VA L L E Y VALL E Y A1 A4.01 F1 A4.01 A10 A2.31 A10 A2.31 A10 A2.31 E10 A2.31 EA. SIDE A10 A2.31 E10 A2.31 A10 A2.31 A10 A2.31 F1 A3.02 A1 A3.01 F1 A3.01 800 POUNDS 800 POUNDS VALL E Y VA L L E Y V A L L E Y V A L L E Y RIDGE E10 A2.31 A10 A2.31 E10 A2.31 E10 A2.31 A10 A2.31 E10 A2.31 800 POUNDS A1 A3.02 45 MIL T.P.O. SINGLE-PLY ROOFING SYSTEM PIPE BOOT PER ROOFING MANUF. BUILT-UP INSULATION o/ 6 MIL VAPOR BARRIER ROOF SHEATHING, RE: STRUCTURAL CLAMPING RING WATER STOP & SEALANT PER ROOFING MANUF. RECOMMENDATIONS VENT OR PIPE PENETRATION, RE: MECHANICAL 12 " M I N . 45 MIL T.P.O. SINGLE-PLY ROOFING SYSTEM CANT STRIP BUILT-UP INSULATION o/ 6 MIL VAPOR BARRIER ROOF SHEATHING, RE: STRUCTURAL INSULATED METAL CURB RE: MECHANICAL METAL CURB CAP AND FLASHING AS REQUIRED PER UNIT. RE: MECHANICAL FASTENERS AS REQUIRED ROOF TOP UNIT. RE: MECHANICAL ROOF FRAMING, RE: STRUCTURAL PRE-FINISHED METAL PARAPET CAP W/ DRIP EDGE, RE: ELEVATIONS VARIES T.O. PLATE 6" CONCEALED CLIP & FASTENER WRAP SINGLE-PLY ROOFING OVER T.O. WALL ASSEMBLY SEALANT STUCCO FINISH SYSTEM o/ RIGID INSULATION VAPOR RETARDANT BUILDING PAPER 3" 1/ 2 " SLOPED 1/2" PLYWOOD WOOD BLOCKING FASTENER W/ NEOPRENE WASHER SINGLE PLY ROOFING FULLY ADHERED @ WALL CONT. CANT ROOF ASSEMBLY, RE: ROOFING PLAN HOT AIR WELD LEDGER, RE: STRUCTURAL WALL ASSEMBLY, RE: FLOOR PLAN EXTEND BATT INSUL. TO T.O. ROOF INSUL MIN. SIDING VARIES, RE: ELEVATIONS 4"2 1/2" 8" PRE-FINISHED METAL PARAPET CAP W/ DRIP EDGE, RE: ELEVATIONS VARIES T.O. PLATE CONCEALED CLIP & FASTENER WRAP SINGLE-PLY ROOFING OVER T.O. WALL ASSEMBLY SEALANT VAPOR RETARDANT BUILDING PAPER 6" 1/ 2 " SLOPED 1/2" PLYWOOD WOOD BLOCKING FASTENER W/ NEOPRENE WASHER SINGLE PLY ROOFING FULLY ADHERED @ WALL CONT. CANT ROOF ASSEMBLY, RE: ROOFING PLAN HOT AIR WELD LEDGER, RE: STRUCTURAL WALL ASSEMBLY, RE: FLOOR PLAN EXTEND BATT INSUL. TO T.O. ROOF INSUL MIN. 3/4" 3-PART CEMENT PLASTER SYSTEM O/ METAL LATH, RE: ELEVATIONS SCALE: ROOF PARAPET CAP 1-1/2" = 1'-0"A10 SCALE: ROOF PARAPET CAP 1-1/2" = 1'-0"E10 1713 16 JANUARY 2018 rudeenarchitects Boise + San Francisco 199 North Capitol Blvd. Suite 602 Boise, Idaho 83702 Phone 208-338-1413 Fax 208-336-0371 info@rudeenarchitects.com architecture planning project management THESE DESIGNS AND DRAWINGS ARE THE EXCLUSIVE PROPERTY OF RUDEEN & ASSOCIATES ARCHITECTS, AND ARE NOT TO BE USED OR DUPLICATED WITHOUT PERMISSION. COPYRIGHT © 2018, ALL RIGHTS RESERVED. Jade Way Office Building New Construction: 1739 S. Jade Way Meridian, Idaho 83642 Harris Cuatro LLC 2 OWNER CORRECTION FEBRUARY 1 2018 SCALE: ROOF PLAN 1/8" = 1'-0"A1 16'8'4'0 16' W S EN 1713 A231.DWG A2.31 AS NOTED ROOF PLAN KEY NOTES:# 1.LINE OF WALL, BELOW. 2.PROVIDE OVERFLOW DRAIN PER MECHANICAL PLANS. 3.OVERBUILD THIS PORTION OF ROOF TO ACHIEVE POSITIVE DRAINAGE. 4.MECHANICAL UNIT ON MECHANICAL CURB PER MECHANICAL PLANS AND DETAIL K4/A2.31. 5.CONDENSING UNIT PER MECHANICAL PLANS. 6.MECHANICAL VENT OR PIPE PENETRATION, RE: MECHANICAL AND DETAIL K1/A2.31 SIM. 7.INSULATED METAL ROOF ACCESS LADDER, RE: DETAIL A10/A2.11. 8.MECHANICAL CURB LOCATION FOR FUTURE MECHANICAL UNIT, RE: MECHANICAL AND DETAIL K4/A2.31. 9.45 MIL SINGLE PLY TPO ROOFING SYSTEM o/ (2) LAYERS OF 2-1/2" (R-30) MIN. POLY ISO RIGID INSULATION, TYP. o/ ROOF SHEATHING PER STRUCTURAL. 10.WALK PADS, TYP. SCALE: TYPICAL ROOF PENETRATION DETAIL 1-1/2" = 1'-0"K1 SCALE: TYPICAL ROOF CURB DETAIL 1-1/2" = 1'-0"K4 1 TYP. 8 4 3 1 TYP. 1 TYP. 6 6 7 2 TYP. 2 TYP. 2 TYP. 9 TYP. 9 TYP. 5 4 10 TYP. 10 TYP. 10 TYP. 2