Loading...
A1.01_SITE PLAN8" INTEGRAL COLOR SPLIT-FACE CMU BLOCK, RE: STRUCTURAL 4" 5' - 8 " 6' - 0 " 2" x 2-1/2" x 1/4" ANGLE FRAME W/ 22 GA. B-DECK WELDED TO FRAME. PAINT GATE TO MATCH BUILDING CONCRETE FOOTING, RE: STRUCTURAL PROVIDE DIAGONAL 'X' BRACING BEHIND B-DECKING PROVIDE NON-REMOVABLE 3/4" DIA. x 24" CANE BOLTS AT EACH GATE DOORS TO OPEN TO 120 DEGREES WITH WIND STOPS PRECAST CONCRETE CAP, PAINT 8" INTEGRAL COLOR SPLIT-FACE CMU BLOCK, RE: STRUCTURAL PRECAST CONCRETE CAP, PAINT CONCRETE FOOTING, RE: STRUCTURAL 8" INTEGRAL COLOR SPLIT-FACE CMU BLOCK, RE: STRUCTURAL PRECAST CONCRETE CAP, PAINT 8" INTEGRAL COLOR SPLIT-FACE CMU BLOCK, RE: STRUCTURAL PRECAST CONCRETE CAP, PAINT 14'-0" 1'-4"1'-4" 12'-0"14'-0"12'-0" 6'-8"3'-4"2'-0" 6' - 0 " 6' - 0 " 6' - 0 " CONCRETE FOOTING, RE: STRUCTURAL CONCRETE FOOTING, RE: STRUCTURAL 2'-8" 3-LOOP 1'-0"8"1'-0" 4" R = 6 " T Y P . NOTE: ALL EXPOSED METAL SHALL BE POWDER COATED OR GALVANIZED. RE: ARCHITECT FOR FINISH COLOR. 2" DIA. METAL PIPE EMBEDDED IN CONCRETE FOOTING. CONCRETE FOOTING. CONCRETE SIDEWALK OR PAVING PER CIVIL DRAWINGS. 3' - 6 " 1' - 2 " 6" 8" TYP. 1'-0" 1' - 6 " 5" 10" 2' - 8 " 4" 3' - 0 " 5' - 0 " 2" INTERNATIONAL SYMBOL OF ACCESSIBILITY. PAINTED TO ASPHALT IN THE CENTER OF DESIGNATED ACCESSIBLE PARKING SPACE(S). BLUE BACKGROUND WITH WHITE SYMBOL. 1/ 2 " NOTE: ISA SIGN SHALL BE LOCATED AT EACH ACCESSIBLE PARKING STALL. 3' - 0 " 3'-0" ACCESSIBLE PARKING STALL SIGNAGE CAP AT TOP OF POST (BEHIND) INTERNATIONAL SYMBOL OF ACCESSIBILITY. BLUE BACKGROUND WITH WHITE SYMBOL & LETTERING AT PARKING SPACES WITH 8'-0" ADJACENT AISLE FOR THE USE OF SIDE LIFT ACCESSIBLE VEHICLES 2" DIA. METAL POST EMBEDDED IN CONCRETE FOOTING CONCRETE FOOTING LANDSCAPING,CONCRETE SIDEWALK OR PAVING AS SHOWN ON SITE PLAN 2" COMPACTED SUB-GRADE. ACCESSIBLE PARKING STALL SYMBOL 6" 1" CONC. FOOTING #6 BAR THRU PIPE, WELD CONC. GROUT CAP, SLOPE TO SHED WATER 6" DIA. PIPE FILLED W/ CONC. PAINT CONC. / PAVING SLOPE AWAY FROM PIPE NOTE: INSTALL STEEL PIPE MIN. 8" FROM FACE OF WALL 1" 3' - 0 " 3' - 0 " 3" 3" 1'-0" A1.01 J7 A1.01 J13 A1.01 J10 A1.01 J2 E10 A1.011 2 3 4 5 7 68910111213 20 21 19 18 17 16 15 14 A10 A1.01 TYP. OF (4) E13 A1.01 M 1713 16 JANUARY 2018 rudeenarchitects Boise + San Francisco 199 North Capitol Blvd. Suite 602 Boise, Idaho 83702 Phone 208-338-1413 Fax 208-336-0371 info@rudeenarchitects.com architecture planning project management THESE DESIGNS AND DRAWINGS ARE THE EXCLUSIVE PROPERTY OF RUDEEN & ASSOCIATES ARCHITECTS, AND ARE NOT TO BE USED OR DUPLICATED WITHOUT PERMISSION. COPYRIGHT © 2018, ALL RIGHTS RESERVED. Jade Way Office Building New Construction: 1739 S. Jade Way Meridian, Idaho 83642 Harris Cuatro LLC 2 OWNER CORRECTION FEBRUARY 1 2018 1713 A101.DWG A1.01 AS NOTED SITE PLAN SCALE: SITE PLAN 1" = 20'-0"A2 0 40'20'10' W S E N SCALE: TRASH ENCLOSURE ELEVATION 1/4" = 1'-0"J2 SCALE: TRASH ENCLOSURE ELEVATION 1/4" = 1'-0"J7 SCALE: TRASH ENCLOSURE ELEVATION 1/4" = 1'-0"J10 SCALE: TRASH ENCLOSURE ELEVATION 1/4" = 1'-0"J13 SCALE: ACCESSIBLE PARKING SIGN DETAIL 1/2" = 1'-0"E10 SCALE: BICYCLE PARKING DETAIL 1/2" = 1'-0"E13 SCALE: PIPE BOLLARD DETAIL 3/4" = 1'-0"A10 PARKING REQUIRED (TITLE 11-3C-6): BUILDING AREA -5950 / 500 = 11.9 TOTAL PARKING STALLS REQUIRED = 12 STALLS TOTAL ACCESSIBLE STALLS REQUIRED = 1 STALLS PARKING PROVIDED: STANDARD STALLS = 20 STALLS ACCESSIBLE STALLS = 1 STALLS TOTAL PROVIDED = 21 STALLS BICYCLE PARKING REQUIRED (TITLE 11-3C-6): PARKING SPACES -21 / 25 = 1 SPACE TOTAL BICYCLE PARKING PROVIDED = 2 SPACES PARKING ANALYSIS UTILITY TRANSFORMER, RE: ELECTRICAL. MAIN METER, RE: ELECTRICAL. LIGHT FIXTURE, TYP. RE: ELECTRICAL. LIGHT FIXTURE, TYP. RE: ELECTRICAL. WATER FEATURE, RE: CIVIL / LANDSCAPE & ELECTRICAL 2