Haven Behavioral Health Site PlanGENERAL NOTES
SITE KEYNOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS AND SHALL
NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND CONFIGURATIONS SHOWN IN THE
CONSTRUCTION DRAWINGS.
EXISTING MECHANICAL, PLUMBING, ELECTRICAL SYSTEMS MUST
CONTINUE TO OPERATE AS REQUIRED TO SATISFY OWNER
THROUGHOUT THE CONSTRUCTION PERIOD.
CONTRACTOR SHALL INSTALL FENCING TO SECURE SITE AT
APPROXIMATE LOCATIONS SHOWN. PROVIDE HINGED GATES AS
REQUIRED TO PROVIDE EASY ACCESS TO SITE FOR ALL
CONSTRUCTION WORK TO OCCUR.
CONTRACTOR SHALL PROVIDE TREE PROTECTION WHERE TREES
TO REMAIN ARE AFFECTED BY CONSTRUCTION WORK.
CONTRACTOR SHALL EMPLOY DUST REDUCTION MEASURES WHEN
PERFORMING EXCAVATION GRADING OR DEMOLITION WORK ON SITE.
CONTRACTOR SHALL PROVIDE WASH-DOWN FACILITIES TO CLEAN
LOOSE DIRT, ROCK, VEGETATION OR ANY TYPE OF DEMOLITION
DEBRIS FROM TRUCKS EXITING THE PROPERTY.
ALL TRUCKS EXITING THE SITE MUST BE COVERED BY DUST
REDUCING TOPS.
SITE INFORMATION SHOWN ON ARCHITECTURAL SITE PLANS ARE FOR
REFERENCE ONLY. REFER TO CIVIL DRAWINGS FOR EXACT SCOPE.\
REFERENCE CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES
WITHIN THEIR RESPECTIVE PORTIONS OF WORK.
CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL
EQUIPMENT, INCLUDING CONTRACTOR-FURNISHED CIVIL,
STRUCTURAL, ARCHITECTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNER AND
ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION.
NEW
BEHAVIORAL
HEALTH HOSPITAL
ONE-STORY / 60,751 SF
FINISH FIRST FLOOR
ELEVATION ??' = 0'-0"
NEW
CANOPY
NEW
CANOPY
NEW
CANOPY
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A1.0
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
SIT
E
P
L
A
N
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/32" = 1'-0"A1.0
01 COMPOSITE SITE PLAN
B
A
C
11
22
33
55
44
66
6.7
7 8
9 9
10 10
11 11
13 13
12 12
14 14
15 15
16
17.6
17
18 18
17.5
19
20 20
22 22
21 21
23 23
24 24
25 25
3.4
5.9
6.1 6.4
6.51
6.8
7.3
7.3 6.9
6.9
6.5
6.5
6.6
6.6
7.4
A
A
A.3
A.3
A.7
A.7
B
B
C D
D D.1 E
E
F
F
H
H
K
K
M
M
P
PM.6
M.7 L
G
G
J
J
S
S
U
U
W
W
Y
Y
R
R
T
T
V
V
X
XP.5
P.5
C.3
C.5
A.4
C.4
C.1 B.9
OF FI CE
A 156
T RE A T ME NT PLA NNI NG
A 161
ST
A 157
ELE CT RI C
D138 IT
A 147
DI RE CT O R
HR
A 132 HR AS S I ST A NT
A 131
HR
WA IT ING
A 130
ST
B 108
ACTI V IT Y
THE RA P Y
W O RK R O O M
B 124
SO I LE D
HO LDI NG
B 122
S T O RA G E
B 125
HO US E K E E P I NG
MA I N
B 127
AMB ULA NCE W O RK R O O M
B 123 CLE A N
LI NE N
HO LDI NG
B 121
ME D G A S
B 135
MA I NT E NA NCE / G RO UNDS S T O RA G E
B 136
MS T
B120T
MA T E RI A LS MA NA G E ME NT
B 133
PT/ S
C124T
ST
C133
SE RV I CE
CO RRI DO R
B 131
DRY
S T O RA G E
A 159
PT/ S
C126T
PT/ S
C132T
AP T/ S
C131T
THE RAP I S T
OF F I CE
A 127
DI RECT O R OUT P A TI E NT
THE RA P Y
A 128
ME CHA NI CA L
B 128
E ME RG E NCY ELE CT RI C
B 130
NO RMA L
ELE CT RI C
B 129
KI T CHE N
A 155 DI NI NG
A 152
PT/ S
C130T
PT/ S
C129T
PT/ S
C128T
PT/ S
C127T
PT/ S
D146T
PT/ S
C149T
S T O RA G E
D147T
PT/ S
D151T
PT/ S
C144T PT/ S
C147T
PT/ S
C146T
ST
D136
PT/ S
D133T
AP T/ S
D134T
PT/ S
D131T
NO IS Y ACT IV IT Y
D125
PT/ S
D132T
PT/ S
D130T
PT/ S
D128T
PT/ S
D126T
S T O RA G E
D123
PT/ S
D109T
PT/ S
D105T
PT/ S
D104T PT/ S
D102T
PT/ S
D106T
PT/ S
D103T
PT/ S
D107T
LA UN DRY
D100A
PT/ S
D100T ST
D101A
AP T/ S
D101T
PLA NT
O P S
W O RK R O O M
B 126
ADMI S SI O NS
W O RK R O O M
A 102
TRA INI NG
A 151
HR TE S TI NG
A 133
YA RD
S T O RA G E
A 142
VE S T IB ULE
1001
PT/ S
D129T
ELE CT RI C
C136
SO CI A L W O RK
W O RK R O O M
A 149
PA T IE NT
RO O M
D131
PA T IE NT
RO O M
D129
PA T IE NT
RO O M
D128
PA T IE NT
RO O M
D130
PA T IE NT
RO O M
D124
PA T IE NT
RO O M
D126
PA T IE NT
RO O M
D132
ADA
PA T IE NT
RO O M
D134
PA T IE NT
RO O M
D133
CO MF O RT
D119
CO NS ULT
D145
LA UN DRY
D135
NURS E MA NA G E R
D115
NO URI S H
D116
CO NS ULT
D120
PA T IE NT RO O M
D109
CO NS ULT
D111
ME DI CI NE
D137
CLE A N LI NE N
D112B
S T O RA G E
D112A
E X A M
D139
JA NIT O R
D141
S E CLUS I O N
D143B
S E CLUS I O N
D143A
PT
D143T
A NT E
D143
PA T IE NT RO O M
D105
PA T IE NT
RO O M
D107
PA T IE NT
RO O M
D106
PA T IE NT RO O M
D104
PA T IE NT
RO O M
D100
PA T IE NT
RO O M
D102
ADA
PA T IE NT
RO O M
D101
PA T IE NT
RO O M
D103
CO RRI DO R
1020
S T O RA G E
D108
CO RRI DO R
1023
S T A F F B RE A K / LO CK E R
A 148
CO NF E R E NCE
A 145
LO B B Y
1002
PA T IE NT RO O M
D149
PA T IE NT RO O M
D151
PA T IE NT RO O M
D150
PA T IE NT RO O M
D148
PA T IE NT
RO O M
C149
PA T IE NT RO O M
C147
PA T IE NT RO O M
C146
PA T IE NT RO O M
C132
PA T IE NT RO O M
C129
ADA PA T IE NT
RO O M
C131
PA T IE NT RO O M
C128
PA T IE NT RO O M
C127
PA T IE NT RO O M
C126
PA T IE NT RO O M
C124
CF O
A 139
CO O
A 137
CE O
A 135
CO P Y /
MAI L
A 141
DI RE CT O R
PT / RM
A 136
DI RE CT O R SO CI A L
SE RV I CE S
138
FILE/ S T O RA G E
A 140
ME DI CA L
DI RE CT O R
B 109
DO N
B 111
UR/ B O W O RK R O O M
B 114
BUS I NE S S DE V E LO P ME NT
B 115
PHY S ICI A N
LO UNG E
B 117
HA LL
B 118
MR W O RK R O O M
B 112
ACT IV I T Y T HE RA P Y
C140
S T A F F B RE A K / LO CK E R
B 143
T RE A T ME NT PLA NNI NG
B 142 G Y MNA S I UM
B 141
LO CK E R/
S E A RCH
A 103
A S S E S S ME NT
A 104
A S S E S S ME NT
A 106
A S S E S S ME NT
A 108
NO URI S H
A 110
A S S E S S ME NT
A 107
PT
A 111
S T A F F
BRE A K /
LO CK E R
A 105
OUT P A TI E NT NURS E
A 126
DI RE CT O R
ADMI S SI O NS
A 109
PT
A 122
OUT P A TI E NT
PHYS I CI A N
A 124
ST AF F
HALL
A 118
ST
A 120
PT
A 119
ADMIS S IO NS
SUB W A IT I NG
A 101
HA LL
A 113
OUT P A TI E NT W O RK RO O M
A 116
G RO UP T HE RA P Y
B 104
G RO UP T HE RA P Y
B 103
G RO UP T HE RA P Y
B 101
HA LL
A 129
HA LL
B 106
G RO UP T HE RA P Y
B 102
UR W O RK R O O M
B 116
PA T IE NT EF F E CT S
B 144
FS L
B 119
P HA RM A CY
W O R K
B 145
CO RRI DO R
1006
FS T
B119T
PT
B 138
CO RRI DO R
1008
PA T IE NT
RO O M
D146
ACT IV I T Y
T HE RA P Y
D142
HA LL
D140
SO I LE D
LI NE N
D144
CO RRI DO R
1015
CO RRI DO R
1016
G RO UP T HE RA P Y
D147
G RO UP
T HE RA P Y
C145
PA T IE NT
RO O M
C144
CO MF O RT
C119
CO NS ULT
C143
HA LL
C138A
CO NS ULT
C121
S T O RA G E
C120
SO I LE D
LI NE N
C142
ME DI CI NE
C112
CLE A N LI NE N
C135
CO RRI DO R
1010
NO URI S H
C116
CO RRI DO R
1011
PT/ S
D149T
LA UN DRY
C145A
NO IS Y
ACT IV T Y
C125
LA UN DRY
C134 A NT E
C141
PT
C141T
S E CLUS I O N
C141B
JA NIT O R
C139
E X A M
C137
S E CLUS I O N
C141A
JA NIT O R
A 158
THE RAP I S T
OF F I CE
A 123
THE RAP I S T OF F I CE
A 121
THE RAP I S T OF F I CE
A 125
RE CE P T I O N
A 100
HA LL
A 112
OUT P A TI E NT SUB W A IT I NG
A 115
CO MM O N
A RE A
B 100
CO RRI DO R
1004
CO RRI DO R
1003
PT
A 146
RE CEP T IO N/ SUB W A IT I NG
A 134
NO URI S H
B 107
HA LL
A 144
HA LL
A 143
HA LL
A 114
CO RRI DO R
1007
MS L
B 120
NURS E
ST A TI O N
B 139
1
B 137A
2
B 137B
3
B 137C
4
B 140A
E CT
P RO CE DURE
B 140 E CT
P RE P / RE CO V E RY
B 137
CO RRI DO R
1012
PA T IE NT
RO O M
C122
CO RRI DO R
1014
S E RV E RY
A 153
DI S HW A S HE R
A 154 HA LL
A 160
QUIE T
ACT IV IT Y
D110
W O RK R O O M
D114
CO RRI DO R
1017
CO RRI DO R
1021
CO RRI DO R
1018
NURS E
MA NA G E R
C115
CO NS ULT
C111
W O RK R O O M
C114
PA T IE NT
RO O M
C103 PT/ S
C103T
AP T/ S
C104T
ADA
PA T IE NT
RO O M
C104
PA T IE NT
RO O M
C102 PT/ S
C102T
PA T IE NT RO O M
C100
PT/ S
C100T
PT/ S
C101T PA T IE NT RO O M
C101
PA T IE NT
RO O M
C106
ADA
PA T IE NT
RO O M
C105
AP T/ S
C105T
PT/ S
C107T
PT/ S
C106T
PT/ S
C109T
PA T IE NT RO O M
C109
PA T IE NT RO O M
C107
PA T IE NT RO O M
C148
PT/ S
C148T PT/ S
D150T
UNI S E X
P UB I C
TO I LE T
1002T
S T O RA G E
C123
PT/ S
C122T
PA T IE NT
RO O M
D121
PT/ S
D121T
PT/ S
D122T
PA T IE NT RO O M
D122
PT/ S
D124T
WA LK - I N CO O LE R WA LK- I N
F RE E Z E R
QUIE T ACT IV IT Y
C110
G RO UP
T HE RA P Y
C108
S T O RA G E
B 105A
ELE CT RI C
B 105B
PT/ S
B 134
A MB ULA NCE
P RO CE S S I NG
B 132
ACT IV IT Y YA RD
PT/ S
D148T
IT
C138B
V E NDI NG
A LCO V E
A 152A
W O RK R O O M
D117
NURS E ST A TI O N
D118
NURS E
ST A TI O N
C118
NURS E
ST A TI O N
D113
NURS E
ST A TI O N
C113
W O RK R O O M
C117B
W O RK R O O M
C117A
A7.1 01
A7.1
02
A7.1 03
A7.1
04
A7.1
05
A7.1 06
A7.1
04 SIM
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A4.1
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
CO
M
P
O
S
I
T
E
F
L
O
O
R
P
L
A
N
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/16" = 1'-0" A4.1
01 COMPOSITE FLOOR PLAN
BEHAVIORAL HEALTH HOSPITAL RENOVATION
KEYPLAN
NOT TO SCALE
AREA 'D'
AREA 'C'AREA 'B'
AREA 'A'
B
A
C
Canopy A existing conditions.
The new Canopy A will match this
existing adjacent canopy.
Canopy B existing conditions.
The new Canopy B will match
this existing adjacent camopy.
Canopy C existing conditions.
The new Canopy C shall be constructed of metal, and match
the adjacent exterior window system color.
2
3
5
44
66
77
9 9
10 10
11
12 12
3.4
5.9
6.1
6.4
6.51
6.8
7.3
7.3 6.9
6.9
6.5
6.5
6.6
6.6
7.4
A.7
A.7
B
B
C D
D D.1 E
E
L
L
G
G
J
J
C.3
C.5
A.4
C.4
C.1 B.9
THERAPIST
OFFICE
A123
THERAPIST
OFFICE
A125
OFFICE
A156
TREATMENT
PLANNING
A161
ST
A157
ELECTRIC
D138
IT
A147
DRY
STORAGE
A159
THERAPIST
OFFICE
A127
DIRECTOR
OUTPATIENT
THERAPY
A128
KITCHEN
A155
DINING
A152
PT/S
D146T
PT/S
D102T
PT/S
D106T
ADMISSIONS
WORKROOM
A102
TRAINING
A151
VESTIBULE
1001
SOCIAL WORK
WORKROOM
A149
MEDICINE
D137
STORAGE
D112A
JANITOR
A158
EXAM
D139
JANITOR
D141
SECLUSION
D143B
SECLUSION
D143A
PT
D143T ANTE
D143
PATIENT ROOM
D106
PATIENT ROOM
D104
PATIENT ROOM
D100
PATIENT ROOM
D102
CORRIDOR
1023
STAFF
BREAK/LOCKER
A148
CONFERENCE
A145
LOBBY
1002
PATIENT ROOM
D150
PATIENT ROOM
D148
CFO
A139
COO
A137
CEO
A135
DIRECTOR
PT/RM
A136
DIRECTOR
SOCIAL
SERVICES
138
LOCKER/
SEARCH
A103
ASSESSMENT
A104
ASSESSMENT
A106
ASSESSMENT
A108
NOURISH
A110
ASSESSMENT
A107
PT
A111
STAFF BREAK /
LOCKER
A105
OUTPATIENT
NURSE
A126
DIRECTOR
ADMISSIONS
A109
PT
A122
OUTPATIENT
PHYSICIAN
A124
STAFF HALL
A118
ADMISSIONS
SUBWAITING
A101
HALL
A113
HALL
A129
PATIENT ROOM
D146
ACTIVITY
THERAPY
D142
HALL
D140
RECEPTION
A100
HALL
A112
CORRIDOR
1004
CORRIDOR
1003
PT
A146
RECEPTION/
SUBWAITING
A134
HALL
A143
HALL
A114
SERVERY
A153
DISHWASHER
A154 HALL
A160
QUIET ACTIVITY
D110
CORRIDOR
1024
UNISEX
PUBIC TOILET
1002T
CORRIDOR
1021
WALK-IN
COOLER WALK-IN
FREEZER
STAFF PATIO
NEW CANOPY
VENDING
ALCOVE
A152A
A101A A 1 0 1 B
A100
A 1 0 2
A11
2
A118A
A122
A109 A124
A126
A105A A105B
A107
A104
A106
A108
A110
A1
0
3
100
3
A
1002A
A138 A139
A136 A137
A135
A1
3
4
1003B
A14
5
A146
A153A
A153B
A1
5
4
A1
4
7
A1
4
9
A16
0
D1
4
0
A
D1
4
0
B
D1
4
2
D13
8
D13
9
D14
1
D1
4
3
D1
4
3
A
D1
4
3
B
A 1 51
A15
2
A155B
A15
9
A15
8
A15
7
A15
6
A16
1
A1
4
8
1021A
A142 A140
A114
A1
2
0
D15
0
T
D1
4
6
T
D1
1
2
B
D13
7
A
D143T
D10
6
T
D1
0
2
T
1 002 T A111
A151A
03
A8.2
02
A8.2
02
A8.2
SIM
01
A8.2
A121
A123
A125
A127
A128
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL,
AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL
ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK.
CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL
EQUIPMENT, INCLUDING CONTRACTOR FURNISHED
ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND
ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION
GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL
EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS
OTHERWISE NOTED.
ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED
FACE OF WALL UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND
WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF
8'-0" A.F.F.
EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT
GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO
RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS).
ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS
OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE
OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE
INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE
NOTED.
REFERENCE SPECIFICATION SECTION 102800 FOR TOILET
ACCESSORY ITEMS DEFINED BY THE TA-X TAG.
REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW
ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER.
FLOOR PLAN KEYNOTES
CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL
BLOCKING FOR THE FOLLOWING ITEMS:
FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES,
MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS,
COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC
SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS,
PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED.
REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING
REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS
NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF
THE PROJECT MANUAL SHALL STILL BE MET.
PLAN
NOTE
EQUIPMENT
NUMBER
NEW DOOR/
NUMBER
EXTERIOR
ELEVATION
INTERIOR
ELEVATION SECTION
ROOM NAME/
NUMBER
FRAME ELEVATION/
GLASS TYPE
XXXXX.XX
G-X
PARTITION
TYPE
XX
XXX
PLAN LEGEND
XXX
XXXXX
XX
A7.X A8.X
CORNER
GUARD
3H
A8.X
XX XX
LIFE SAFETY PARTITION LEGEND
1-HOUR FIRE BARRIER SMOKE BARRIER
XXX
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A4.1A
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PA
R
T
I
A
L
F
L
O
O
R
P
L
A
N
-
A
R
E
A
'
A
'
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/8" = 1'-0" A4.1A
01 PARTIAL
FLOOR PLAN - AREA 'A'
BEHAVIORAL HEALTH HOSPITAL RENOVATION
KEYPLAN
NOT TO SCALE
AREA 'D'
AREA 'C'AREA 'B'
AREA 'A'
C
12 12
14 14
15 15
17 17
18 18
17.5
19
21 21
23 23
A
A
A.3
A.3
A.7
A.7
B
B
C
C
D
D E
E
F
F
H
H
THERAPIST
OFFICE
A121
THERAPIST
OFFICE
A123
DIRECTOR HR
A132
HR ASSISTANT
A131
HR WAITING
A130
ST
B108
ACTIVITY
THERAPY
WORKROOM
B124
SOILED
HOLDING
B122
STORAGE
B125
HOUSEKEEPING
MAIN
B127
AMBULANCE
WORKROOM
B123 CLEAN LINEN
HOLDING
B121
MED GAS
B135
MAINTENANCE/GROUNDS
STORAGE
B136
MST
B120T
MATERIALS
MANAGEMENT
B133
SERVICE
CORRIDOR
B131
MECHANICAL
B128
EMERGENCY
ELECTRIC
B130
NORMAL
ELECTRIC
B129
PLANT OPS
WORKROOM
B126
HR TESTING
A133
YARD
STORAGE
A142
CFO
A139
COPY/
MAIL
A141
DIRECTOR
SOCIAL
SERVICES
138
FILE/ STORAGE
A140
MEDICAL
DIRECTOR
B109
DON
B111
UR/BO
WORKROOM
B114
BUSINESS
DEVELOPMENT
B115
PHYSICIAN
LOUNGE
B117
HALL
B118
MR
WORKROOM
B112
STAFF
BREAK/LOCKER
B143
TREATMENT
PLANNING
B142
GYMNASIUM
B141
NOURISH
A110
PT
A111
PT
A122
STAFF HALL
A118
ST
A120
PT
A119
OUTPATIENT
WORKROOM
A116
GROUP
THERAPY
B104
GROUP
THERAPY
B103
GROUP
THERAPY
B101
HALL
B106
STORAGE
B105A
GROUP
THERAPY
B102
UR WORKROOM
B116
PATIENT
EFFECTS
B144
FSL
B119
PHARMACY
WORK
B145
CORRIDOR
1006
FST
B119T
PT
B138
CORRIDOR
1008
3
B137C
OUTPATIENT
SUBWAITING
A115
COMMON
AREA
B100
NOURISH
B107
HALL
A144
HALL
A143
HALL
A114
CORRIDOR
1007
MSL
B120 NURSE STATION
B139
1
B137A
2
B137B
4
B140A
ECT
PREP/RECOVERY
B137
ECT
PROCEDURE
B140
CORRIDOR
1004
ACTIVITY
YARD
ELECTRIC
B105B
PT/S
B134
AMBULANCE
PROCESSING
B132
A118A
A122 A110
A138 A139
A142
A144B
A140
A144A
B108
B109
B111
B112
B116
B117
B115
B1
1
8
100
5
A141
B105B
B105A
B10
6
B103
B101
B104
B102
A130
A13
1
A132
A114
A1
2
0
A1
1
9
A12
9
1006
10
0
7
A
B145
1007B
B132
B134
B14
4
B13
7
B138
B1
4
1
B14
2
B14
3
1010A
A111
01
A8.1
04
A8.2
02
A8.1
02
A8.2
SIM 02
A8.2
SIM
A121
A123
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL,
AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL
ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK.
CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL
EQUIPMENT, INCLUDING CONTRACTOR FURNISHED
ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND
ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION
GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL
EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS
OTHERWISE NOTED.
ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED
FACE OF WALL UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND
WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF
8'-0" A.F.F.
EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT
GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO
RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS).
ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS
OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE
OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE
INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE
NOTED.
REFERENCE SPECIFICATION SECTION 102800 FOR TOILET
ACCESSORY ITEMS DEFINED BY THE TA-X TAG.
REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW
ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER.
FLOOR PLAN KEYNOTES
CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL
BLOCKING FOR THE FOLLOWING ITEMS:
FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES,
MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS,
COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC
SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS,
PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED.
REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING
REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS
NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF
THE PROJECT MANUAL SHALL STILL BE MET.
PLAN
NOTE
EQUIPMENT
NUMBER
NEW DOOR/
NUMBER
EXTERIOR
ELEVATION
INTERIOR
ELEVATION SECTION
ROOM NAME/
NUMBER
FRAME ELEVATION/
GLASS TYPE
XXXXX.XX
G-X
PARTITION
TYPE
XX
XXX
PLAN LEGEND
XXX
XXXXX
XX
A7.X A8.X
CORNER
GUARD
3H
A8.X
XX XX
LIFE SAFETY PARTITION LEGEND
1-HOUR FIRE BARRIER SMOKE BARRIER
XXX
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A4.1B
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PA
R
T
I
A
L
F
L
O
O
R
P
L
A
N
-
A
R
E
A
'
B
'
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/8" = 1'-0" A4.1B
01 PARTIAL
FLOOR PLAN - AREA 'B'
BEHAVIORAL HEALTH HOSPITAL RENOVATION
KEYPLAN
NOT TO SCALE
AREA 'D'
AREA 'C'AREA 'B'
AREA 'A'
A
B
11 11
13 13
15 15
16
17.6
17
18 18
19
20 20
22 22
24 24
25 25
H
H
K
K
M
M
P
PM.6
L
R
R
T
T
V
V
X
XP.5
P.5
PT/S
C124T
ST
C133
PT/S
C126T
PT/S
C132T
APT/S
C131T
PT/S
C130T
PT/S
C129T
PT/S
C128T
PT/S
C127T
PT/S
C149T PT/S
D151T
PT/S
C144T PT/S
C147T
PT/S
C146T
ELECTRIC
C136
PATIENT ROOM
D151
PATIENT ROOM
D150
PATIENT ROOM
C149
PATIENT ROOM
C147
PATIENT ROOM
C146
PATIENT ROOM
C132
PATIENT ROOM
C129
ADA PATIENT
ROOM
C131
PATIENT ROOM
C128
PATIENT ROOM
C127
PATIENT ROOM
C126
PATIENT ROOM
C124
ACTIVITY
THERAPY
C140
CORRIDOR
1015
CORRIDOR
1016
GROUP
THERAPY
C145 PATIENT ROOM
C144
COMFORT
C119
CONSULT
C143
HALL
C138A
CONSULT
C121
STORAGE
C120
WORKROOM
C117B
SOILED
LINEN
C142
MEDICINE
C112
CLEAN
LINEN
C135
CORRIDOR
1010
NOURISH
C116
CORRIDOR
1011
LAUNDRY
C145A
NOISY ACTIVTY
C125
LAUNDRY
C134
ANTE
C141 PT
C141T
SECLUSION
C141B
JANITOR
C139
EXAM
C137
SECLUSION
C141A
CORRIDOR
1014
PATIENT ROOM
C122
CORRIDOR
1012
PATIENT ROOM
C100
PT/S
C100T
PT/S
C101T
PATIENT ROOM
C101
PT/S
C103T
PATIENT ROOM
C103
PATIENT ROOM
C102
PT/S
C102T
APT/S
C104T
ADA PATIENT
ROOM
C104
CONSULT
C111 NURSE
MANAGER
C115
WORKROOM
C114
PATIENT ROOM
C106
PT/S
C106T
PT/S
C107T
APT/S
C105T
ADA PATIENT
ROOM
C105
PATIENT ROOM
C107
PATIENT ROOM
C109
PT/S
C109T
CORRIDOR
1013
PT/S
C122T
STORAGE
C123
NURSE STATION
C118
NURSE STATION
C113
PATIENT ROOM
C148
PT/S
C148T PT/S
D150T
QUIET ACTIVITY
C110
GROUP
THERAPY
C108
?
?
1010A
10
1
1
C1
0
0
T
C100
C102
C10
2
T
C1
0
4
T
C104
C106
C10
6
T
C108
C112B
10
1
0
B
C114
C111
C10
9
T
C109
C107
C10
7
T
C105
C1
0
5
T
C10
3
T
C103
C101
C1
0
1
T
C11
6
C118
C117
C11
5
C143
C1
1
9
C1
2
3
C1
2
2
C122T
C12
0
C12
1
1014
C1
2
4
C124T C1
2
6
C126T
C128T
C1
2
8
C13
0
C130T C132T
C13
2
C13
4
1012 C13
3
C1
3
1
C131T
C1
2
9
C129T
C12
7
C127T
C145
C145A
C14
7
T
C147
10
1
5
C149
C14
9
T
D151
D1
5
1
T
D150
10
1
6
D1
5
0
T
C148
C14
8
T
C146
C14
6
T
C144
C14
4
T
C142
C1
3
5
C13
6
C138D
C138C
C1
3
8
A
C1
4
0
C141T
C14
1
C14
1
A
C14
1
B
C13
9
C13
7
C11
2
A
C13
8
B
IT
C138B
C1
1
3
A
C11
3
B
WORKROOM
C117A
02
A8.2
SIM
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL,
AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL
ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK.
CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL
EQUIPMENT, INCLUDING CONTRACTOR FURNISHED
ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND
ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION
GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL
EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS
OTHERWISE NOTED.
ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED
FACE OF WALL UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND
WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF
8'-0" A.F.F.
EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT
GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO
RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS).
ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS
OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE
OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE
INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE
NOTED.
REFERENCE SPECIFICATION SECTION 102800 FOR TOILET
ACCESSORY ITEMS DEFINED BY THE TA-X TAG.
REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW
ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER.
FLOOR PLAN KEYNOTES
CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL
BLOCKING FOR THE FOLLOWING ITEMS:
FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES,
MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS,
COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC
SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS,
PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED.
REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING
REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS
NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF
THE PROJECT MANUAL SHALL STILL BE MET.
PLAN
NOTE
EQUIPMENT
NUMBER
NEW DOOR/
NUMBER
EXTERIOR
ELEVATION
INTERIOR
ELEVATION SECTION
ROOM NAME/
NUMBER
FRAME ELEVATION/
GLASS TYPE
XXXXX.XX
G-X
PARTITION
TYPE
XX
XXX
PLAN LEGEND
XXX
XXXXX
XX
A7.X A8.X
CORNER
GUARD
3H
A8.X
XX XX
LIFE SAFETY PARTITION LEGEND
1-HOUR FIRE BARRIER SMOKE BARRIER
XXX
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A4.1C
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PA
R
T
I
A
L
F
L
O
O
R
P
L
A
N
-
A
R
E
A
'
C
'
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/8" = 1'-0" A4.1C
01 PARTIAL
FLOOR PLAN - AREA 'C'
BEHAVIORAL HEALTH HOSPITAL RENOVATION
KEYPLAN
NOT TO SCALE
AREA 'D'
AREA 'C'AREA 'B'
AREA 'A'
11
22
33
55
44
66
6.7
7
8
9 9
11 11
M
M
P
P
M.7 L
L
J
J
S
S
U
U
W
W
Y
Y
ST
A157
ELECTRIC
D138
DRY
STORAGE
A159
PT/S
D146T
STORAGE
D147T
ST
D136
PT/S
D133T
APT/S
D134T
PT/S
D131T
NOISY ACTIVITY
D125
PT/S
D132T
PT/S
D130T
PT/S
D128T
PT/S
D126T
STORAGE
D123
PT/S
D109T
PT/S
D105T
PT/S
D104T PT/S
D102T
PT/S
D106T
PT/S
D103T
PT/S
D107T
LAUNDRY
D100A
PT/S
D100T ST
D101A
APT/S
D101T
PT/S
D129T
PATIENT ROOM
D131
PATIENT ROOM
D129
PATIENT ROOM
D128
PATIENT ROOM
D130
PATIENT ROOM
D124
PATIENT ROOM
D126
WORKROOM
D117
PATIENT ROOM
D132
ADA PATIENT
ROOM
D134
PATIENT ROOM
D133
COMFORT
D119
CONSULT
D145
LAUNDRY
D135
NURSE
MANAGER
D115
NOURISH
D116
CONSULT
D120
PATIENT ROOM
D109
CONSULT
D111
MEDICINE
D137
CLEAN
LINEN
D112B
STORAGE
D112A
JANITOR
A158
EXAM
D139
JANITOR
D141
SECLUSION
D143B
SECLUSION
D143A
PT
D143T ANTE
D143
PATIENT ROOM
D105
PATIENT ROOM
D107
PATIENT ROOM
D106
PATIENT ROOM
D104
PATIENT ROOM
D100
PATIENT ROOM
D102
ADA PATIENT
ROOM
D101
PATIENT ROOM
D103
CORRIDOR
1020
STORAGE
D108
PATIENT ROOM
D149
PATIENT ROOM
D148
PATIENT ROOM
D146
ACTIVITY
THERAPY
D142
HALL
D140
SOILED
LINEN
D144
GROUP
THERAPY
D147
PT/S
D149T
NURSE STATION
D113
QUIET ACTIVITY
D110
WORKROOM
D114
NURSE STATION
D118
CORRIDOR
1017
CORRIDOR
1018
CORRIDOR
1021
CORRIDOR
1019
PT/S
D124T
PATIENT ROOM
D122
PT/S
D121T
PT/S
D122T
PATIENT ROOM
D121
D14
0
A
D1
4
0
B
D1
4
2
D13
8
D13
9
D14
1
D1
4
3
D1
4
3
A
D1
4
3
B
A15
9
A15
8
A15
7
A16
1
1021A
D145
D1
1
9
D147 D146
D1
4
6
T
D1
4
8
T
D148 D149 D1
4
9
T
D147T
101
7
D144
D1
1
2
B
D13
7
A
D137B
102
1
B
D1
1
3
B
D143T
D112A
D1
1
6
D117
D114
D1
1
5
D111
D118
D11
3
A
D108
D10
6
T
D106
D104
D10
4
T
D1
0
2
T
D102
D100B D10
0
T
D100A
D101A
D101B D1
0
1
T
D103
D10
3
T
D10
5
T
D105
D107
D1
0
7
T
D1
0
9
T
D109
1019
D1
2
1
D121T
D122T
D1
2
2
D1
2
4
D1
2
3
D1
2
0
D124T
D1
2
6
D126T
D128T
D12
8
D13
0
D130T
D1
3
2
D132T
D1
3
4
D134T
D13
6
1018
D13
5
D133T
D1
3
3
D131T
D1
3
1
D12
9
D129T
102
0
02
A8.2
01
A8.2
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL,
AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL
ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK.
CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL
EQUIPMENT, INCLUDING CONTRACTOR FURNISHED
ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND
ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION
GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL
EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS
OTHERWISE NOTED.
ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED
FACE OF WALL UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND
WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF
8'-0" A.F.F.
EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT
GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO
RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS).
ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS
OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE
OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE
INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE
NOTED.
REFERENCE SPECIFICATION SECTION 102800 FOR TOILET
ACCESSORY ITEMS DEFINED BY THE TA-X TAG.
REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW
ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER.
FLOOR PLAN KEYNOTES
CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL
BLOCKING FOR THE FOLLOWING ITEMS:
FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES,
MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS,
COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC
SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS,
PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED.
REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING
REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS
NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF
THE PROJECT MANUAL SHALL STILL BE MET.
PLAN
NOTE
EQUIPMENT
NUMBER
NEW DOOR/
NUMBER
EXTERIOR
ELEVATION
INTERIOR
ELEVATION SECTION
ROOM NAME/
NUMBER
FRAME ELEVATION/
GLASS TYPE
XXXXX.XX
G-X
PARTITION
TYPE
XX
XXX
PLAN LEGEND
XXX
XXXXX
XX
A7.X A8.X
CORNER
GUARD
3H
A8.X
XX XX
LIFE SAFETY PARTITION LEGEND
1-HOUR FIRE BARRIER SMOKE BARRIER
XXX
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A4.1D
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PA
R
T
I
A
L
F
L
O
O
R
P
L
A
N
-
A
R
E
A
'
D
'
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
TRUE
NORTH
1/8" = 1'-0" A4.1D
01 PARTIAL
FLOOR PLAN - AREA 'D'
BEHAVIORAL HEALTH HOSPITAL RENOVATION
KEYPLAN
NOT TO SCALE
AREA 'D'
AREA 'C'AREA 'B'
AREA 'A'
14
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
04
A8.2
10' - 0"
A.7 B
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
21
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
01
A8.1
02
A8.1
24' - 0"
D
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
11' - 6"
EG
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
9
17' - 4"
T.O. Masonry
15' - 0"
T.O. Steel
03
A8.2
02
A8.2
SIM
A R C H I T E C T U R E
613 WEST MAIN STREET
LOUISVILLE, KENTUCKY 40202
502.893.1875
502.893.1876 fax
S T E N G E L H I L L
Civil Engineering
Structural Engineering
Mechanical/Electrical Engineering
Interior Design
ME
R
I
D
I
A
N
,
I
D
A
H
O
A7.1
SHA.HBH1702
26 MARCH 2018
CO
N
S
T
R
U
C
T
I
O
N
D
R
A
W
I
N
G
S
-
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
EX
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
BE
H
A
V
I
O
R
A
L
H
E
A
L
T
H
H
O
S
P
I
T
A
L
R
E
N
O
V
A
T
I
O
N
HA
V
E
N
B
E
H
A
V
I
O
R
A
L
H
E
A
L
T
H
C
A
R
E
1/8" = 1'-0" A7.1
01 EXTERIOR ELEVATION
1/8" = 1'-0" A7.1
02 EXTERIOR ELEVATION
1/8" = 1'-0" A7.1
03 EXTERIOR ELEVATION
1/8" = 1'-0" A7.1
04 EXTERIOR ELEVATION
1/8" = 1'-0" A7.1
05 EXTERIOR ELEVATION
1/8" = 1'-0" A7.1
06 EXTERIOR ELEVATION
AABB
CC