Haven Behavioral Health Site PlanGENERAL NOTES SITE KEYNOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONFIGURATIONS SHOWN IN THE CONSTRUCTION DRAWINGS. EXISTING MECHANICAL, PLUMBING, ELECTRICAL SYSTEMS MUST CONTINUE TO OPERATE AS REQUIRED TO SATISFY OWNER THROUGHOUT THE CONSTRUCTION PERIOD. CONTRACTOR SHALL INSTALL FENCING TO SECURE SITE AT APPROXIMATE LOCATIONS SHOWN. PROVIDE HINGED GATES AS REQUIRED TO PROVIDE EASY ACCESS TO SITE FOR ALL CONSTRUCTION WORK TO OCCUR. CONTRACTOR SHALL PROVIDE TREE PROTECTION WHERE TREES TO REMAIN ARE AFFECTED BY CONSTRUCTION WORK. CONTRACTOR SHALL EMPLOY DUST REDUCTION MEASURES WHEN PERFORMING EXCAVATION GRADING OR DEMOLITION WORK ON SITE. CONTRACTOR SHALL PROVIDE WASH-DOWN FACILITIES TO CLEAN LOOSE DIRT, ROCK, VEGETATION OR ANY TYPE OF DEMOLITION DEBRIS FROM TRUCKS EXITING THE PROPERTY. ALL TRUCKS EXITING THE SITE MUST BE COVERED BY DUST REDUCING TOPS. SITE INFORMATION SHOWN ON ARCHITECTURAL SITE PLANS ARE FOR REFERENCE ONLY. REFER TO CIVIL DRAWINGS FOR EXACT SCOPE.\ REFERENCE CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK. CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL EQUIPMENT, INCLUDING CONTRACTOR-FURNISHED CIVIL, STRUCTURAL, ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNER AND ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. NEW BEHAVIORAL HEALTH HOSPITAL ONE-STORY / 60,751 SF FINISH FIRST FLOOR ELEVATION ??' = 0'-0" NEW CANOPY NEW CANOPY NEW CANOPY A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A1.0 SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N SIT E P L A N BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/32" = 1'-0"A1.0 01 COMPOSITE SITE PLAN B A C 11 22 33 55 44 66 6.7 7 8 9 9 10 10 11 11 13 13 12 12 14 14 15 15 16 17.6 17 18 18 17.5 19 20 20 22 22 21 21 23 23 24 24 25 25 3.4 5.9 6.1 6.4 6.51 6.8 7.3 7.3 6.9 6.9 6.5 6.5 6.6 6.6 7.4 A A A.3 A.3 A.7 A.7 B B C D D D.1 E E F F H H K K M M P PM.6 M.7 L G G J J S S U U W W Y Y R R T T V V X XP.5 P.5 C.3 C.5 A.4 C.4 C.1 B.9 OF FI CE A 156 T RE A T ME NT PLA NNI NG A 161 ST A 157 ELE CT RI C D138 IT A 147 DI RE CT O R HR A 132 HR AS S I ST A NT A 131 HR WA IT ING A 130 ST B 108 ACTI V IT Y THE RA P Y W O RK R O O M B 124 SO I LE D HO LDI NG B 122 S T O RA G E B 125 HO US E K E E P I NG MA I N B 127 AMB ULA NCE W O RK R O O M B 123 CLE A N LI NE N HO LDI NG B 121 ME D G A S B 135 MA I NT E NA NCE / G RO UNDS S T O RA G E B 136 MS T B120T MA T E RI A LS MA NA G E ME NT B 133 PT/ S C124T ST C133 SE RV I CE CO RRI DO R B 131 DRY S T O RA G E A 159 PT/ S C126T PT/ S C132T AP T/ S C131T THE RAP I S T OF F I CE A 127 DI RECT O R OUT P A TI E NT THE RA P Y A 128 ME CHA NI CA L B 128 E ME RG E NCY ELE CT RI C B 130 NO RMA L ELE CT RI C B 129 KI T CHE N A 155 DI NI NG A 152 PT/ S C130T PT/ S C129T PT/ S C128T PT/ S C127T PT/ S D146T PT/ S C149T S T O RA G E D147T PT/ S D151T PT/ S C144T PT/ S C147T PT/ S C146T ST D136 PT/ S D133T AP T/ S D134T PT/ S D131T NO IS Y ACT IV IT Y D125 PT/ S D132T PT/ S D130T PT/ S D128T PT/ S D126T S T O RA G E D123 PT/ S D109T PT/ S D105T PT/ S D104T PT/ S D102T PT/ S D106T PT/ S D103T PT/ S D107T LA UN DRY D100A PT/ S D100T ST D101A AP T/ S D101T PLA NT O P S W O RK R O O M B 126 ADMI S SI O NS W O RK R O O M A 102 TRA INI NG A 151 HR TE S TI NG A 133 YA RD S T O RA G E A 142 VE S T IB ULE 1001 PT/ S D129T ELE CT RI C C136 SO CI A L W O RK W O RK R O O M A 149 PA T IE NT RO O M D131 PA T IE NT RO O M D129 PA T IE NT RO O M D128 PA T IE NT RO O M D130 PA T IE NT RO O M D124 PA T IE NT RO O M D126 PA T IE NT RO O M D132 ADA PA T IE NT RO O M D134 PA T IE NT RO O M D133 CO MF O RT D119 CO NS ULT D145 LA UN DRY D135 NURS E MA NA G E R D115 NO URI S H D116 CO NS ULT D120 PA T IE NT RO O M D109 CO NS ULT D111 ME DI CI NE D137 CLE A N LI NE N D112B S T O RA G E D112A E X A M D139 JA NIT O R D141 S E CLUS I O N D143B S E CLUS I O N D143A PT D143T A NT E D143 PA T IE NT RO O M D105 PA T IE NT RO O M D107 PA T IE NT RO O M D106 PA T IE NT RO O M D104 PA T IE NT RO O M D100 PA T IE NT RO O M D102 ADA PA T IE NT RO O M D101 PA T IE NT RO O M D103 CO RRI DO R 1020 S T O RA G E D108 CO RRI DO R 1023 S T A F F B RE A K / LO CK E R A 148 CO NF E R E NCE A 145 LO B B Y 1002 PA T IE NT RO O M D149 PA T IE NT RO O M D151 PA T IE NT RO O M D150 PA T IE NT RO O M D148 PA T IE NT RO O M C149 PA T IE NT RO O M C147 PA T IE NT RO O M C146 PA T IE NT RO O M C132 PA T IE NT RO O M C129 ADA PA T IE NT RO O M C131 PA T IE NT RO O M C128 PA T IE NT RO O M C127 PA T IE NT RO O M C126 PA T IE NT RO O M C124 CF O A 139 CO O A 137 CE O A 135 CO P Y / MAI L A 141 DI RE CT O R PT / RM A 136 DI RE CT O R SO CI A L SE RV I CE S 138 FILE/ S T O RA G E A 140 ME DI CA L DI RE CT O R B 109 DO N B 111 UR/ B O W O RK R O O M B 114 BUS I NE S S DE V E LO P ME NT B 115 PHY S ICI A N LO UNG E B 117 HA LL B 118 MR W O RK R O O M B 112 ACT IV I T Y T HE RA P Y C140 S T A F F B RE A K / LO CK E R B 143 T RE A T ME NT PLA NNI NG B 142 G Y MNA S I UM B 141 LO CK E R/ S E A RCH A 103 A S S E S S ME NT A 104 A S S E S S ME NT A 106 A S S E S S ME NT A 108 NO URI S H A 110 A S S E S S ME NT A 107 PT A 111 S T A F F BRE A K / LO CK E R A 105 OUT P A TI E NT NURS E A 126 DI RE CT O R ADMI S SI O NS A 109 PT A 122 OUT P A TI E NT PHYS I CI A N A 124 ST AF F HALL A 118 ST A 120 PT A 119 ADMIS S IO NS SUB W A IT I NG A 101 HA LL A 113 OUT P A TI E NT W O RK RO O M A 116 G RO UP T HE RA P Y B 104 G RO UP T HE RA P Y B 103 G RO UP T HE RA P Y B 101 HA LL A 129 HA LL B 106 G RO UP T HE RA P Y B 102 UR W O RK R O O M B 116 PA T IE NT EF F E CT S B 144 FS L B 119 P HA RM A CY W O R K B 145 CO RRI DO R 1006 FS T B119T PT B 138 CO RRI DO R 1008 PA T IE NT RO O M D146 ACT IV I T Y T HE RA P Y D142 HA LL D140 SO I LE D LI NE N D144 CO RRI DO R 1015 CO RRI DO R 1016 G RO UP T HE RA P Y D147 G RO UP T HE RA P Y C145 PA T IE NT RO O M C144 CO MF O RT C119 CO NS ULT C143 HA LL C138A CO NS ULT C121 S T O RA G E C120 SO I LE D LI NE N C142 ME DI CI NE C112 CLE A N LI NE N C135 CO RRI DO R 1010 NO URI S H C116 CO RRI DO R 1011 PT/ S D149T LA UN DRY C145A NO IS Y ACT IV T Y C125 LA UN DRY C134 A NT E C141 PT C141T S E CLUS I O N C141B JA NIT O R C139 E X A M C137 S E CLUS I O N C141A JA NIT O R A 158 THE RAP I S T OF F I CE A 123 THE RAP I S T OF F I CE A 121 THE RAP I S T OF F I CE A 125 RE CE P T I O N A 100 HA LL A 112 OUT P A TI E NT SUB W A IT I NG A 115 CO MM O N A RE A B 100 CO RRI DO R 1004 CO RRI DO R 1003 PT A 146 RE CEP T IO N/ SUB W A IT I NG A 134 NO URI S H B 107 HA LL A 144 HA LL A 143 HA LL A 114 CO RRI DO R 1007 MS L B 120 NURS E ST A TI O N B 139 1 B 137A 2 B 137B 3 B 137C 4 B 140A E CT P RO CE DURE B 140 E CT P RE P / RE CO V E RY B 137 CO RRI DO R 1012 PA T IE NT RO O M C122 CO RRI DO R 1014 S E RV E RY A 153 DI S HW A S HE R A 154 HA LL A 160 QUIE T ACT IV IT Y D110 W O RK R O O M D114 CO RRI DO R 1017 CO RRI DO R 1021 CO RRI DO R 1018 NURS E MA NA G E R C115 CO NS ULT C111 W O RK R O O M C114 PA T IE NT RO O M C103 PT/ S C103T AP T/ S C104T ADA PA T IE NT RO O M C104 PA T IE NT RO O M C102 PT/ S C102T PA T IE NT RO O M C100 PT/ S C100T PT/ S C101T PA T IE NT RO O M C101 PA T IE NT RO O M C106 ADA PA T IE NT RO O M C105 AP T/ S C105T PT/ S C107T PT/ S C106T PT/ S C109T PA T IE NT RO O M C109 PA T IE NT RO O M C107 PA T IE NT RO O M C148 PT/ S C148T PT/ S D150T UNI S E X P UB I C TO I LE T 1002T S T O RA G E C123 PT/ S C122T PA T IE NT RO O M D121 PT/ S D121T PT/ S D122T PA T IE NT RO O M D122 PT/ S D124T WA LK - I N CO O LE R WA LK- I N F RE E Z E R QUIE T ACT IV IT Y C110 G RO UP T HE RA P Y C108 S T O RA G E B 105A ELE CT RI C B 105B PT/ S B 134 A MB ULA NCE P RO CE S S I NG B 132 ACT IV IT Y YA RD PT/ S D148T IT C138B V E NDI NG A LCO V E A 152A W O RK R O O M D117 NURS E ST A TI O N D118 NURS E ST A TI O N C118 NURS E ST A TI O N D113 NURS E ST A TI O N C113 W O RK R O O M C117B W O RK R O O M C117A A7.1 01 A7.1 02 A7.1 03 A7.1 04 A7.1 05 A7.1 06 A7.1 04 SIM A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A4.1 SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N CO M P O S I T E F L O O R P L A N BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/16" = 1'-0" A4.1 01 COMPOSITE FLOOR PLAN BEHAVIORAL HEALTH HOSPITAL RENOVATION KEYPLAN NOT TO SCALE AREA 'D' AREA 'C'AREA 'B' AREA 'A' B A C Canopy A existing conditions. The new Canopy A will match this existing adjacent canopy. Canopy B existing conditions. The new Canopy B will match this existing adjacent camopy. Canopy C existing conditions. The new Canopy C shall be constructed of metal, and match the adjacent exterior window system color. 2 3 5 44 66 77 9 9 10 10 11 12 12 3.4 5.9 6.1 6.4 6.51 6.8 7.3 7.3 6.9 6.9 6.5 6.5 6.6 6.6 7.4 A.7 A.7 B B C D D D.1 E E L L G G J J C.3 C.5 A.4 C.4 C.1 B.9 THERAPIST OFFICE A123 THERAPIST OFFICE A125 OFFICE A156 TREATMENT PLANNING A161 ST A157 ELECTRIC D138 IT A147 DRY STORAGE A159 THERAPIST OFFICE A127 DIRECTOR OUTPATIENT THERAPY A128 KITCHEN A155 DINING A152 PT/S D146T PT/S D102T PT/S D106T ADMISSIONS WORKROOM A102 TRAINING A151 VESTIBULE 1001 SOCIAL WORK WORKROOM A149 MEDICINE D137 STORAGE D112A JANITOR A158 EXAM D139 JANITOR D141 SECLUSION D143B SECLUSION D143A PT D143T ANTE D143 PATIENT ROOM D106 PATIENT ROOM D104 PATIENT ROOM D100 PATIENT ROOM D102 CORRIDOR 1023 STAFF BREAK/LOCKER A148 CONFERENCE A145 LOBBY 1002 PATIENT ROOM D150 PATIENT ROOM D148 CFO A139 COO A137 CEO A135 DIRECTOR PT/RM A136 DIRECTOR SOCIAL SERVICES 138 LOCKER/ SEARCH A103 ASSESSMENT A104 ASSESSMENT A106 ASSESSMENT A108 NOURISH A110 ASSESSMENT A107 PT A111 STAFF BREAK / LOCKER A105 OUTPATIENT NURSE A126 DIRECTOR ADMISSIONS A109 PT A122 OUTPATIENT PHYSICIAN A124 STAFF HALL A118 ADMISSIONS SUBWAITING A101 HALL A113 HALL A129 PATIENT ROOM D146 ACTIVITY THERAPY D142 HALL D140 RECEPTION A100 HALL A112 CORRIDOR 1004 CORRIDOR 1003 PT A146 RECEPTION/ SUBWAITING A134 HALL A143 HALL A114 SERVERY A153 DISHWASHER A154 HALL A160 QUIET ACTIVITY D110 CORRIDOR 1024 UNISEX PUBIC TOILET 1002T CORRIDOR 1021 WALK-IN COOLER WALK-IN FREEZER STAFF PATIO NEW CANOPY VENDING ALCOVE A152A A101A A 1 0 1 B A100 A 1 0 2 A11 2 A118A A122 A109 A124 A126 A105A A105B A107 A104 A106 A108 A110 A1 0 3 100 3 A 1002A A138 A139 A136 A137 A135 A1 3 4 1003B A14 5 A146 A153A A153B A1 5 4 A1 4 7 A1 4 9 A16 0 D1 4 0 A D1 4 0 B D1 4 2 D13 8 D13 9 D14 1 D1 4 3 D1 4 3 A D1 4 3 B A 1 51 A15 2 A155B A15 9 A15 8 A15 7 A15 6 A16 1 A1 4 8 1021A A142 A140 A114 A1 2 0 D15 0 T D1 4 6 T D1 1 2 B D13 7 A D143T D10 6 T D1 0 2 T 1 002 T A111 A151A 03 A8.2 02 A8.2 02 A8.2 SIM 01 A8.2 A121 A123 A125 A127 A128 GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK. CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL EQUIPMENT, INCLUDING CONTRACTOR FURNISHED ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED FACE OF WALL UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF 8'-0" A.F.F. EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS). ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE NOTED. REFERENCE SPECIFICATION SECTION 102800 FOR TOILET ACCESSORY ITEMS DEFINED BY THE TA-X TAG. REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER. FLOOR PLAN KEYNOTES CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL BLOCKING FOR THE FOLLOWING ITEMS: FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES, MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS, COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS, PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED. REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF THE PROJECT MANUAL SHALL STILL BE MET. PLAN NOTE EQUIPMENT NUMBER NEW DOOR/ NUMBER EXTERIOR ELEVATION INTERIOR ELEVATION SECTION ROOM NAME/ NUMBER FRAME ELEVATION/ GLASS TYPE XXXXX.XX G-X PARTITION TYPE XX XXX PLAN LEGEND XXX XXXXX XX A7.X A8.X CORNER GUARD 3H A8.X XX XX LIFE SAFETY PARTITION LEGEND 1-HOUR FIRE BARRIER SMOKE BARRIER XXX A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A4.1A SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N PA R T I A L F L O O R P L A N - A R E A ' A ' BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/8" = 1'-0" A4.1A 01 PARTIAL FLOOR PLAN - AREA 'A' BEHAVIORAL HEALTH HOSPITAL RENOVATION KEYPLAN NOT TO SCALE AREA 'D' AREA 'C'AREA 'B' AREA 'A' C 12 12 14 14 15 15 17 17 18 18 17.5 19 21 21 23 23 A A A.3 A.3 A.7 A.7 B B C C D D E E F F H H THERAPIST OFFICE A121 THERAPIST OFFICE A123 DIRECTOR HR A132 HR ASSISTANT A131 HR WAITING A130 ST B108 ACTIVITY THERAPY WORKROOM B124 SOILED HOLDING B122 STORAGE B125 HOUSEKEEPING MAIN B127 AMBULANCE WORKROOM B123 CLEAN LINEN HOLDING B121 MED GAS B135 MAINTENANCE/GROUNDS STORAGE B136 MST B120T MATERIALS MANAGEMENT B133 SERVICE CORRIDOR B131 MECHANICAL B128 EMERGENCY ELECTRIC B130 NORMAL ELECTRIC B129 PLANT OPS WORKROOM B126 HR TESTING A133 YARD STORAGE A142 CFO A139 COPY/ MAIL A141 DIRECTOR SOCIAL SERVICES 138 FILE/ STORAGE A140 MEDICAL DIRECTOR B109 DON B111 UR/BO WORKROOM B114 BUSINESS DEVELOPMENT B115 PHYSICIAN LOUNGE B117 HALL B118 MR WORKROOM B112 STAFF BREAK/LOCKER B143 TREATMENT PLANNING B142 GYMNASIUM B141 NOURISH A110 PT A111 PT A122 STAFF HALL A118 ST A120 PT A119 OUTPATIENT WORKROOM A116 GROUP THERAPY B104 GROUP THERAPY B103 GROUP THERAPY B101 HALL B106 STORAGE B105A GROUP THERAPY B102 UR WORKROOM B116 PATIENT EFFECTS B144 FSL B119 PHARMACY WORK B145 CORRIDOR 1006 FST B119T PT B138 CORRIDOR 1008 3 B137C OUTPATIENT SUBWAITING A115 COMMON AREA B100 NOURISH B107 HALL A144 HALL A143 HALL A114 CORRIDOR 1007 MSL B120 NURSE STATION B139 1 B137A 2 B137B 4 B140A ECT PREP/RECOVERY B137 ECT PROCEDURE B140 CORRIDOR 1004 ACTIVITY YARD ELECTRIC B105B PT/S B134 AMBULANCE PROCESSING B132 A118A A122 A110 A138 A139 A142 A144B A140 A144A B108 B109 B111 B112 B116 B117 B115 B1 1 8 100 5 A141 B105B B105A B10 6 B103 B101 B104 B102 A130 A13 1 A132 A114 A1 2 0 A1 1 9 A12 9 1006 10 0 7 A B145 1007B B132 B134 B14 4 B13 7 B138 B1 4 1 B14 2 B14 3 1010A A111 01 A8.1 04 A8.2 02 A8.1 02 A8.2 SIM 02 A8.2 SIM A121 A123 GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK. CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL EQUIPMENT, INCLUDING CONTRACTOR FURNISHED ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED FACE OF WALL UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF 8'-0" A.F.F. EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS). ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE NOTED. REFERENCE SPECIFICATION SECTION 102800 FOR TOILET ACCESSORY ITEMS DEFINED BY THE TA-X TAG. REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER. FLOOR PLAN KEYNOTES CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL BLOCKING FOR THE FOLLOWING ITEMS: FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES, MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS, COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS, PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED. REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF THE PROJECT MANUAL SHALL STILL BE MET. PLAN NOTE EQUIPMENT NUMBER NEW DOOR/ NUMBER EXTERIOR ELEVATION INTERIOR ELEVATION SECTION ROOM NAME/ NUMBER FRAME ELEVATION/ GLASS TYPE XXXXX.XX G-X PARTITION TYPE XX XXX PLAN LEGEND XXX XXXXX XX A7.X A8.X CORNER GUARD 3H A8.X XX XX LIFE SAFETY PARTITION LEGEND 1-HOUR FIRE BARRIER SMOKE BARRIER XXX A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A4.1B SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N PA R T I A L F L O O R P L A N - A R E A ' B ' BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/8" = 1'-0" A4.1B 01 PARTIAL FLOOR PLAN - AREA 'B' BEHAVIORAL HEALTH HOSPITAL RENOVATION KEYPLAN NOT TO SCALE AREA 'D' AREA 'C'AREA 'B' AREA 'A' A B 11 11 13 13 15 15 16 17.6 17 18 18 19 20 20 22 22 24 24 25 25 H H K K M M P PM.6 L R R T T V V X XP.5 P.5 PT/S C124T ST C133 PT/S C126T PT/S C132T APT/S C131T PT/S C130T PT/S C129T PT/S C128T PT/S C127T PT/S C149T PT/S D151T PT/S C144T PT/S C147T PT/S C146T ELECTRIC C136 PATIENT ROOM D151 PATIENT ROOM D150 PATIENT ROOM C149 PATIENT ROOM C147 PATIENT ROOM C146 PATIENT ROOM C132 PATIENT ROOM C129 ADA PATIENT ROOM C131 PATIENT ROOM C128 PATIENT ROOM C127 PATIENT ROOM C126 PATIENT ROOM C124 ACTIVITY THERAPY C140 CORRIDOR 1015 CORRIDOR 1016 GROUP THERAPY C145 PATIENT ROOM C144 COMFORT C119 CONSULT C143 HALL C138A CONSULT C121 STORAGE C120 WORKROOM C117B SOILED LINEN C142 MEDICINE C112 CLEAN LINEN C135 CORRIDOR 1010 NOURISH C116 CORRIDOR 1011 LAUNDRY C145A NOISY ACTIVTY C125 LAUNDRY C134 ANTE C141 PT C141T SECLUSION C141B JANITOR C139 EXAM C137 SECLUSION C141A CORRIDOR 1014 PATIENT ROOM C122 CORRIDOR 1012 PATIENT ROOM C100 PT/S C100T PT/S C101T PATIENT ROOM C101 PT/S C103T PATIENT ROOM C103 PATIENT ROOM C102 PT/S C102T APT/S C104T ADA PATIENT ROOM C104 CONSULT C111 NURSE MANAGER C115 WORKROOM C114 PATIENT ROOM C106 PT/S C106T PT/S C107T APT/S C105T ADA PATIENT ROOM C105 PATIENT ROOM C107 PATIENT ROOM C109 PT/S C109T CORRIDOR 1013 PT/S C122T STORAGE C123 NURSE STATION C118 NURSE STATION C113 PATIENT ROOM C148 PT/S C148T PT/S D150T QUIET ACTIVITY C110 GROUP THERAPY C108 ? ? 1010A 10 1 1 C1 0 0 T C100 C102 C10 2 T C1 0 4 T C104 C106 C10 6 T C108 C112B 10 1 0 B C114 C111 C10 9 T C109 C107 C10 7 T C105 C1 0 5 T C10 3 T C103 C101 C1 0 1 T C11 6 C118 C117 C11 5 C143 C1 1 9 C1 2 3 C1 2 2 C122T C12 0 C12 1 1014 C1 2 4 C124T C1 2 6 C126T C128T C1 2 8 C13 0 C130T C132T C13 2 C13 4 1012 C13 3 C1 3 1 C131T C1 2 9 C129T C12 7 C127T C145 C145A C14 7 T C147 10 1 5 C149 C14 9 T D151 D1 5 1 T D150 10 1 6 D1 5 0 T C148 C14 8 T C146 C14 6 T C144 C14 4 T C142 C1 3 5 C13 6 C138D C138C C1 3 8 A C1 4 0 C141T C14 1 C14 1 A C14 1 B C13 9 C13 7 C11 2 A C13 8 B IT C138B C1 1 3 A C11 3 B WORKROOM C117A 02 A8.2 SIM GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK. CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL EQUIPMENT, INCLUDING CONTRACTOR FURNISHED ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED FACE OF WALL UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF 8'-0" A.F.F. EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS). ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE NOTED. REFERENCE SPECIFICATION SECTION 102800 FOR TOILET ACCESSORY ITEMS DEFINED BY THE TA-X TAG. REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER. FLOOR PLAN KEYNOTES CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL BLOCKING FOR THE FOLLOWING ITEMS: FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES, MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS, COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS, PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED. REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF THE PROJECT MANUAL SHALL STILL BE MET. PLAN NOTE EQUIPMENT NUMBER NEW DOOR/ NUMBER EXTERIOR ELEVATION INTERIOR ELEVATION SECTION ROOM NAME/ NUMBER FRAME ELEVATION/ GLASS TYPE XXXXX.XX G-X PARTITION TYPE XX XXX PLAN LEGEND XXX XXXXX XX A7.X A8.X CORNER GUARD 3H A8.X XX XX LIFE SAFETY PARTITION LEGEND 1-HOUR FIRE BARRIER SMOKE BARRIER XXX A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A4.1C SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N PA R T I A L F L O O R P L A N - A R E A ' C ' BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/8" = 1'-0" A4.1C 01 PARTIAL FLOOR PLAN - AREA 'C' BEHAVIORAL HEALTH HOSPITAL RENOVATION KEYPLAN NOT TO SCALE AREA 'D' AREA 'C'AREA 'B' AREA 'A' 11 22 33 55 44 66 6.7 7 8 9 9 11 11 M M P P M.7 L L J J S S U U W W Y Y ST A157 ELECTRIC D138 DRY STORAGE A159 PT/S D146T STORAGE D147T ST D136 PT/S D133T APT/S D134T PT/S D131T NOISY ACTIVITY D125 PT/S D132T PT/S D130T PT/S D128T PT/S D126T STORAGE D123 PT/S D109T PT/S D105T PT/S D104T PT/S D102T PT/S D106T PT/S D103T PT/S D107T LAUNDRY D100A PT/S D100T ST D101A APT/S D101T PT/S D129T PATIENT ROOM D131 PATIENT ROOM D129 PATIENT ROOM D128 PATIENT ROOM D130 PATIENT ROOM D124 PATIENT ROOM D126 WORKROOM D117 PATIENT ROOM D132 ADA PATIENT ROOM D134 PATIENT ROOM D133 COMFORT D119 CONSULT D145 LAUNDRY D135 NURSE MANAGER D115 NOURISH D116 CONSULT D120 PATIENT ROOM D109 CONSULT D111 MEDICINE D137 CLEAN LINEN D112B STORAGE D112A JANITOR A158 EXAM D139 JANITOR D141 SECLUSION D143B SECLUSION D143A PT D143T ANTE D143 PATIENT ROOM D105 PATIENT ROOM D107 PATIENT ROOM D106 PATIENT ROOM D104 PATIENT ROOM D100 PATIENT ROOM D102 ADA PATIENT ROOM D101 PATIENT ROOM D103 CORRIDOR 1020 STORAGE D108 PATIENT ROOM D149 PATIENT ROOM D148 PATIENT ROOM D146 ACTIVITY THERAPY D142 HALL D140 SOILED LINEN D144 GROUP THERAPY D147 PT/S D149T NURSE STATION D113 QUIET ACTIVITY D110 WORKROOM D114 NURSE STATION D118 CORRIDOR 1017 CORRIDOR 1018 CORRIDOR 1021 CORRIDOR 1019 PT/S D124T PATIENT ROOM D122 PT/S D121T PT/S D122T PATIENT ROOM D121 D14 0 A D1 4 0 B D1 4 2 D13 8 D13 9 D14 1 D1 4 3 D1 4 3 A D1 4 3 B A15 9 A15 8 A15 7 A16 1 1021A D145 D1 1 9 D147 D146 D1 4 6 T D1 4 8 T D148 D149 D1 4 9 T D147T 101 7 D144 D1 1 2 B D13 7 A D137B 102 1 B D1 1 3 B D143T D112A D1 1 6 D117 D114 D1 1 5 D111 D118 D11 3 A D108 D10 6 T D106 D104 D10 4 T D1 0 2 T D102 D100B D10 0 T D100A D101A D101B D1 0 1 T D103 D10 3 T D10 5 T D105 D107 D1 0 7 T D1 0 9 T D109 1019 D1 2 1 D121T D122T D1 2 2 D1 2 4 D1 2 3 D1 2 0 D124T D1 2 6 D126T D128T D12 8 D13 0 D130T D1 3 2 D132T D1 3 4 D134T D13 6 1018 D13 5 D133T D1 3 3 D131T D1 3 1 D12 9 D129T 102 0 02 A8.2 01 A8.2 GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND FOOD SERVICE DRAWINGS FOR DELINEATION OF ALL ASSEMBLIES WITHIN THEIR RESPECTIVE PORTIONS OF WORK. CONTRACTOR SHALL VERIFY FINAL CONFIGURATION OF ALL EQUIPMENT, INCLUDING CONTRACTOR FURNISHED ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ASSOCIATED WITH EQUIPMENT, WITH OWNERS AND ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION GYPSUM WALLBOARD AND ACOUSTICAL INSULATION SHALL EXTEND TO 6" ABOVE CEILING IN ALL LOCATIONS UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISHED FACE OF WALL UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT GYPSUM BOARD BEHIND AND WITHIN THREE FEET OF ANY PLUMBING FIXTURE TO A HEIGHT OF 8'-0" A.F.F. EXCEPTION: DO NOT PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD AT LOCATIONS SPECIFIED TO RECEIVE WG-2 (REFER TO INTERIOR DESIGN DRAWINGS). ALL INTERIOR PARTITIONS SHALL BE PARTITION TYPE 4 UNLESS OTHERWISE NOTED. EXCEPTION: AT LOCATIONS WHERE ONE SIDE OF INTERIOR PARTITION FACES AN UNOCCUPIABLE SPACE, THE INTERIOR PARTITION SHALL BE TYPE 2 UNLESS OTHERWISE NOTED. REFERENCE SPECIFICATION SECTION 102800 FOR TOILET ACCESSORY ITEMS DEFINED BY THE TA-X TAG. REFERENCE THE FLOOR PLAN FOR TYPICAL EXTERIOR; WINDOW ROUGH OPENING, PILASTER DIMENSIONS, OUTSIDE CORNER. FLOOR PLAN KEYNOTES CONTRACTOR SHALL PROVIDE, COORDINATE AND INSTALL BLOCKING FOR THE FOLLOWING ITEMS: FUTURE HANDRAILS, TOILET ACCESSORIES, DOOR ACCESSORIES, MIRRORS, MARKERBOARDS, CHALKBOARDS, TACKBOARDS, COAT/ROBE HOOKS, WALL MOUNTED EQUIPMENT, DIAGNOSTIC SETS, SHARPS CONTAINERS, MONITORS, TELEVISIONS, CAMERAS, PROJECTORS AND OTHER A/V EQUIPMENT, SIGNAGE IF NEEDED. REFER TO PROJECT MANUAL FOR ADDITIONAL BLOCKING REQUIREMENTS, THIS IS A SUMMARY LISTING OF ITEMS AND IS NOT INTENDED AS A COMPREHENSIVE LIST. REQUIREMENTS OF THE PROJECT MANUAL SHALL STILL BE MET. PLAN NOTE EQUIPMENT NUMBER NEW DOOR/ NUMBER EXTERIOR ELEVATION INTERIOR ELEVATION SECTION ROOM NAME/ NUMBER FRAME ELEVATION/ GLASS TYPE XXXXX.XX G-X PARTITION TYPE XX XXX PLAN LEGEND XXX XXXXX XX A7.X A8.X CORNER GUARD 3H A8.X XX XX LIFE SAFETY PARTITION LEGEND 1-HOUR FIRE BARRIER SMOKE BARRIER XXX A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A4.1D SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N PA R T I A L F L O O R P L A N - A R E A ' D ' BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E TRUE NORTH 1/8" = 1'-0" A4.1D 01 PARTIAL FLOOR PLAN - AREA 'D' BEHAVIORAL HEALTH HOSPITAL RENOVATION KEYPLAN NOT TO SCALE AREA 'D' AREA 'C'AREA 'B' AREA 'A' 14 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 04 A8.2 10' - 0" A.7 B 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 21 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 01 A8.1 02 A8.1 24' - 0" D 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 11' - 6" EG 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 9 17' - 4" T.O. Masonry 15' - 0" T.O. Steel 03 A8.2 02 A8.2 SIM A R C H I T E C T U R E 613 WEST MAIN STREET LOUISVILLE, KENTUCKY 40202 502.893.1875 502.893.1876 fax S T E N G E L H I L L Civil Engineering Structural Engineering Mechanical/Electrical Engineering Interior Design ME R I D I A N , I D A H O A7.1 SHA.HBH1702 26 MARCH 2018 CO N S T R U C T I O N D R A W I N G S - N O T F O R C O N S T R U C T I O N EX T E R I O R E L E V A T I O N S BE H A V I O R A L H E A L T H H O S P I T A L R E N O V A T I O N HA V E N B E H A V I O R A L H E A L T H C A R E 1/8" = 1'-0" A7.1 01 EXTERIOR ELEVATION 1/8" = 1'-0" A7.1 02 EXTERIOR ELEVATION 1/8" = 1'-0" A7.1 03 EXTERIOR ELEVATION 1/8" = 1'-0" A7.1 04 EXTERIOR ELEVATION 1/8" = 1'-0" A7.1 05 EXTERIOR ELEVATION 1/8" = 1'-0" A7.1 06 EXTERIOR ELEVATION AABB CC