Loading...
G-001_Cover Sheet 4-plexPROJECT NARRATIVE THIS PROJECT CONSISTS OF THE CONSTRUCTION OF FOUR -PLEX APARTMENTS IN A NEWLY DEVELOPED SITE THAT INCLUDES (2) 8 -PLEX BUILDINGS AS WELL. THIS DEVELOPMENT WILL PROVIDE VARIATION TO THE NEIGHBORING LOCAL COMMUNITY WHICH CONSISTS PRIMARILY OF SINGLE -FAMILY RESIDENCES, BY INTEGRATING A MULTI -FAMILY RESIDENTIAL COMPONENT. EACH NEW 4 -PLEX UNIT IS A TWO -STORY 4,702 SQ. FT. BUILDING OF WOOD TYPE V -B CONSTRUCTION. THIS PROJECT IS 13 -R FIRE SPRINKLED. ZONING: R -8 AREAS & OCCUPANT LOAD FACTORS: TABLE 1004.1.1: AREAS & OCCUPANT ANALYSIS: RESIDENTIAL AREAS: 200 GROSS APARTMENT BUILDING TOTAL: 4,702sf / 200 = 24 OCCUPANTS PER UNIT A & C = 1,056sf / 200 = 6 PER UNIT B & D = 1,295sf / 200 = 7 APPLICABLE CODES: Seismic Design Category B; Roof Snow Load 25 psf; Wind Load 115 mph, Exposure C per IBC; Frost Depth 24” APARTMENT BUILDING: R-2 OCCUPANCY (RESIDENTIAL) (PER CHAPTER 3) BASIC DESIGN CRITERIA: OCCUPANCY GROUPS: 2 STORY, + -30' IN HEIGHT (2 STORIES ALLOWED, PER TABLE 503) NUMBER OF STORIES / BUILDING HEIGHT 7,000sf ALLOWED > 4,702sf PROPOSED = PASSES TYPE V -B (PER TABLE 601) TYPE OF CONSTRUCTION 0-HR RATED CONSTRUCTION, COMBUSTIBLE MATERIALS OK (PER TABLE 601) FIRE RESISTIVE REQUIREMENTS R-2 OCCUPANCY, SEPARATION WALLS BETWEEN UNITS REQUIRED (PER SECT. 708) PROVIDED, SEE PLANS -FIRE PARTITION / COMMON WALL RATED STAGGERED STUD RATED ASSEMBLY SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY ENTIRE BUILDING = 24; PER DWELLING UNIT = 6 -7; SEE NOTES ABOVE (PER TABLE 1004.1.2) OCCUPANT LOADS (1) REQUIRED, (2) PROVIDED PER UNIT (PER TABLE 1014 thru 1015) SPACES w/ (1) ALLOWED EXIT TO MEET TABLE 1015.1 EXITS REQUIRED (WIDTH) OCCUPANCIES R REQUIRES 125' MAX IF SPRINKLED -PROVIDED (PER SECTION 1014.3) COMMON PATH OF EGRESS ALLOWABLE AREAS BY OCCUPANCY & AREA INCREASES OCCUPANCIES R REQUIRES 250' MAX IF SPRINKLED -PROVIDED (PER SECTION 1016) SPACES w/ (1) ALLOWED EXIT TO MEET TABLE 1021.2, 125' MAX. TRAVEL DISTANCE EXIT ACCESS TRAVEL DISTANCE REQUIRED & PROVIDED PER IBC SECT. 903, NFPA 13 -RAUTOMATIC SPRINKLER SYSTEM (FIRE ALARM) PLUMBING FIXTURE COUNT PER UNIT: WATER CLOSETS: 1 2 2 LAVATORIES: 1 2 2 TUB / SHOWERS: 1 1 2 CLOTHES WASHER CONNECTION: 1 1 1 DISHWASHER: 0 1 1 DOUBLE KITCHEN SINK: 1 1 1 HOSE BIBS (ENTIRE BLDG): 4 PROVIDED CODE ANALYSIS INTERNATIONAL BUILDING CODE (2012 EDITION) INTERNATIONAL FIRE CODE (2012 EDITION) HANDICAP ACCESSIBILITY PER IBC CHAPTER 11 AND CABO/ANSI A -117.1, 2009 EDITION INTERNATIONAL ENERGY CONSERVATION CODE (2012 EDITION) INTERNATIONAL MECHANICAL CODE (2012 EDITION) INTERNATIONAL FUEL GAS CODE (2012 EDITION) IDAHO STATE PLUMBING CODE (2009 EDITION) NATIONAL ELECTRICAL CODE (2014 EDITION) INTERNATIONAL RESIDENTIAL CODE (2012 EDITION) CURRENT LOCAL CODES AND AMENDMENTS. REQ'D PER UNIT PROVIDED - UNIT A & C PROVIDED - UNIT B & D 796 SF Unit B 536 SF Unit C 796 SF Unit D 536 SF Unit A TOTAL FIRST FLOOR GROSS SQUARE FOOTAGE: 2,664sf FED = 51' -0" FED = 52' -6" FED = 52' -6" FED = 51' -0" 100 SF PATIO 80 SF PATIO 80 SF PATIO 80 SF PATIO MAIN ENTRY B MAIN ENTRY A MAIN ENTRY C MAIN ENTRY D 499 SF Unit B 520 SF Unit C 499 SF Unit D 520 SF Unit A TOTAL 2ND FLOOR GROSS SQUARE FOOTAGE: 2,038sf PRESCRIPTIVE ENERGY COMPLIANCE (2012 IECC) INSULATION BY COMPONENT CLIMATE ZONE WINDOW U - FACTOR WINDOW SHGC CEILING R-VALUE WOOD WALL R-VALUE UNHEATED SLAB 5 .35 .32 R-38 R-21 R-10 for 24" below G-001 Cover Sheet G-002 Standards & Abbreviations G-003 Fire Rating C-1 Cover Sheet, General Notes, & Legend C-2 Horizontal Control Plan C-3 Street Plan & Profile C-4 Grading & Drainage Plan (Multifamily North) C-5 Grading & Drainage Plan (Multifamily South) C-6 Drainage Details C-7 Water Plan & Sewer Plan & Profile C-8 Water Plan & Sewer Plan & Profile C-9 Pressure Irrigation Plan & Profile C-10 Gravity Irrigation Plan & Profile C-11 Gravity Irrigation Plan & Profile C-12 Pressure Irrigation & Pump Station Details C-13 Street Light Plan C-14 Entrance Improvement Plan A-101 Site Plan A-102 Site Plan A-111 First Floor A-112 Second Floor A-120 Typical Unit A & C Enlarged Plan A-121 Typical Unit A & C Enlarged Plan A-122 Typical Unit B & D Enlarged Plan A-123 Typical Unit B & D Enlarged Plan A-131 Lower Roof Plan A-132 Roof Plan A-141 First Floor -RCP A-142 Second Floor -RCP A-211 Exterior Elevations A-311 Building Sections A-321 Wall Sections A-322 Stair Sections -Unit B & D A-323 Stair Sections -Unit A & C A-324 Stair Details A-341 Firestop Details A-342 Firestop Details A-343 Firestop Details A-421 Interior Elevations A-521 Interior Details A-601 Schedules A-602 Window Schedule S-200 Foundation Plan S-201 Second Floor & Lower Roof Plan S-202 Roof Framing Plan S-300 Foundation Details S-301 Foundation Details S-302 Foundation Details S-400 Framing Details S-401 Framing Details S-402 Framing Details S-100 General Notes & Specifications M-100 Mechanical Cover Sheet M-200 Crawlspace HVAC Plan M-201 First Floor HVAC Plan M-202 Second Floor HVAC Plan M-300 Mechanical Specifications & Energy Compliance P-100 Plumbing Cover Sheet P-200 Crawlspace Waste & Vent Plan P-201 First Floor Waste & Vent Plan P-202 Second Floor Waste & Vent Plan P-300 Crawlspace Plumbing Plan P-301 First Floor Plumbing Plan P-302 Second Floor Plumbing Plan E-0.0 Electrical Symbols & Index E-1.0 Site Photometric Plan E-1.1 Electrical Site Plan E-3.0 One -Line Diagrams E-3.1 Electrical Details E-3.2 Electrical Schedules E-3.3 Electrical Schedules Sheet Number Sheet Name Sheet List MERIDIAN RD., MERIDIAN ID 83642 4-PLEX MULTIFAMILY BUILDING 4,702sf BUILDING WITH FOUR APARTMENTS LICENSED ARCHITECT AR 984486 JAMES L. ESCOBAR STATE OF IDAHO CL I E N T : SHEET DATE JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY 12.04.17 16156 Ma d d y n V i l l a g e 4 - P l e x Me r i d i a n R d . , M e r i d i a n I D 8 3 6 4 2 G-001 05.16.16 Ky l e E n z l e r - M a d d y n H o m e s , L L C . Cover Sheet ALB Project Team: Owner: PROJECT LOCATION General Contractor: MADDYN HOMES 99 E STATE ST EAGLE, ID 83616 TEL | 208.571.3344 KYLE ENZLER KYLE.ENZLER@GMAIL.COM MADDYN HOMES 99 E STATE ST EAGLE, ID 83616 TEL | 208.571.3344 KYLE ENZLER KYLE.ENZLER@GMAIL.COM KYLE ENZLER MADDYN HOMES, LLC. Vicinity Map: Legal Description: TAX PARCEL # : R8189820071 & R8189820013 DESCRIPTION: STRASSER FARMS SUBDIVISION LOT SIZE: 10.325 ACRES ZONING: R -8 TOWNSHIP: 3N, RANGE: 1W, SECTION: 01 Mechanical/ Plumbing Consultant TIKKER ENGINEERING 9384 W. OVERLAND RD. BOISE, IDAHO 83709 TEL l 208.658.0218 CONTACT: EMAIL: Kara Rousselle Kara@tikkerengineers.com Electrical Consultant ELECTRICAL ENGINEERING COMPANY 800 S INDUSTRY WAY SUITE # 350 MERIDIAN, IDAHO 83642 TEL l 208.378.4450 CONTACT: EMAIL: Keith Adams kadams@e2co.com Structural Consultant: GLR ENGINEERS 1211 W. MYRTLE ST. SUITE #105 BOISE, IDAHO 83702 TEL l 208.344.2470 CONTACT: EMAIL: Joe Lane joe@glrengineers.com NEUDESIGN ARCHITECTURE 725 E 2ND ST MERIDIAN, IDAHO 83642 TEL l 208.884.2824 CONTACT: EMAIL: Architect : Jim Escobar jim@neudesignarch.com NO. DESCRIPTION DATE 1 FOR PERMIT 12.04.17 - B u i l d i n g A