Loading...
CZC Report and ApplicationCERTIFICATE OF ZONING COMPLIANCE REPORT DATE: November 13, 2017 C��fIEF� �J TO: Richard Wilmot, ALC Architecture FROM: Bill Parsons, Planning Supervisor SUBJECT: Panda Daycare Center - CZC (A-2017-0212) OWNER: Craig SJoberg DESCRIPTION OF APPLICANT'S REQUEST The applicant request Certificate of Zoning Compliance (CZC) approval to convert an existing vacant tenant space (Suite A) to a daycare center and occupy suite E as a learning center for a maximum of 73 children on the site. The proposed site improvements include adding an outdoor play area and additional landscaping on the east and south side of the building. The property is 0.94 acres in the Limited Office Zoning district (L -O). The daycare center use is a principally permitted use in the L -O zone, subject to the specific use standards set forth in UDC 11-4-3-9. The site is located at 1552 N. Crestmont Drive. DECISION The applicant's request for Certificate of Zoning Compliance is tentatively approved with the conditions listed in this report. Approval shall be finalized upon completion of specific use requirements in Unified Development Code 11-4-3-9. Note: This is not a building permit. Please contact Building Services at (208) 887-2211 to ver, if you need a building permit and/or inspection. If you do need a building permit, you must complete that process before you commence the use or construction. Please contact Building Servicesfor additional details about building permits and inspections. Site Conditions of Approval 1. Prior to certificate of occupancy, proof of background check and fire inspection shall be provided to the Planning Division. The applicant or owner shall comply with all State of Idaho and Department of Health and Welfare requirements for daycare facilities. 2. All outdoor play areas shall be completely enclosed by minimum six foot (6) non - scalable fences to secure against exit/entry by small children and to screen abutting properties. 3. Business hours of operation within the L -O districts shall be limited from 6 am to 10 pm as set forth in UDC 11 -2B -3A4. The applicant is proposing to operate between the hours of 6am and 6pm consistent with this standard. 4. The applicant shall construct a 20 -foot wide landscape buffer along a portion of the east and south boundary in accord with UDC Table 11-213-3. The landscape buffer shall comply with the landscape requirements set forth in UDC 11-313-9C. The existing vegetation along these boundaries must be protected during the Conditions Document 1 Panda Daycare Center - CZC - A-2017-0212 construction of the outdoor play area. Process Conditions of Approval 1. No signs are approved with this application. Prior to installing any signs on the property, the applicant shall submit a sign permit application consistent with the standards in UDC Chapter 3 Article D and receive approval for such signs. 2. The applicant shall complete all improvements related to public life, safety, and health as set forth in UDC 11 -5C -3B. A surety agreement may be accepted for other improvements in accord with UDC 11 -5C -3C. 3. The site plan prepared by ALC Collaborative, dated November 1, 2017, labeled Site Plan, is approved by the City of Meridian Planning Division as shown in Exhibit B, with the following comments: a. The existing parking stalls and drive aisles shall comply with the dimensions set forth in UDC Table 11-3C-5. b. Add a bike rack near the main entrance of the facility in accord with UDC 11 -3C -5C and 11 -3C -6G. 4. The approved site/landscape plan may not be altered without prior written approval of the City of Meridian Planning Division. 5. The applicant shall pay any applicable impact fees prior to the issuance of a building permit. 6. If any changes must be made to the site plan to accommodate ACRD requirements, the applicant shall submit a new site plan to the City of Meridian Planning Division for approval prior to issuance of the building permit. 7. The applicant shall complete all required improvements prior to issuance of a Certificate of Occupancy. It is unlawful to use or occupy any building or structure until the Building Official has issued a Certificate of Occupancy. Ongoing Conditions of Approval 1. The applicant and/or assigns shall have the continuing obligation to provide irrigation that meets the standards as set forth in UDC 11-313-6 and to install and maintain all landscaping as set forth in UDC 11-3B-5, UDC 11-313-13 and UDC 11-313-14. 2. The applicant shall comply with the outdoor storage as an accessory use standards as set forth in UDC 11-3A-14. 3. The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site (Midtown Square No. 2 PFP 1998). 4. The issuance of this CZC does not release the applicant from any previous requirements of the other permits issued for the site. 5. The applicant and/or property owner shall have an ongoing obligation to prune all trees to a minimum height of six feet above the ground or sidewalk surface to afford greater visibility of the area. 6. The applicant has a continuing obligation to comply with the outdoor lighting provisions as set forth in UDC 11-3A-11. 7. The applicant and/or property owner shall have an ongoing obligation to maintain all landscaping and constructed features within the clear vision triangle consistent with the standards in UDC 11-3A-3. 8. The applicant and/or assigns shall have the continuing obligation to meet the specific use standards for the proposed use as set forth in UDC 11-4-3-9 Daycare Facility. The operator of the facility shall ensure that parents park in designated parking stalls Conditions Document 2 Panda Daycare Center - CZC - A-2017-0212 to ensure safe discharge and pick up of children. CITY COUNCIL REVIEW The applicant or a party of record may request City Council review of a decision of the Director. All requests for review shall be filed in writing with the Planning Division on or before November 28, 2017, within fifteen (15) days after the written decision is issued, and contain the information listed in UDC 11 -5A -6B. If City Council review of the decision is not requested, the action of the Director represents a final decision on a land use application. You have the right to request a regulatory taking analysis under Idaho Code 67-8003. EXPIRATION The Certificate of Zoning Compliance shall expire if the construction, alteration or the use has not commenced within one year of the date of issuance of the Certificate of Zoning Compliance. In accord with the above provisions, the subject Certificate of Zoning Compliance is valid until November 13, 2018. Conditions Document 3 Panda Daycare Center - CZC - A-2017-0212 Exhibit A: Vicinity Map Vicinity Map °°' C_ 540 I 522 UN � 424 WC 1 429 Tm Kormathn anown on MIS msp D Canp1120 tram v3M Legend C C - mkez r no lamb jeOY V mart a aS 00 n. 001 ftn of AleNUn - -- mates ro warrantry or g:ealanr_ as m the oo�nt SJ 1261W. , r�Prop«Locawn %=raCr, trremesa, or o3i lexnees. or reltiWrl of an/ ottre �irT^1 W CH data pmvuea, for sad phos-, aro assim i. M v;al Aea o'1bbfY brSle lY,Om13D2n Cottlt+eO on Tl6 m]. ■,Ar_o of krp�- 24 -� A4rlalan Ul Lhl TE STE �F�rcr's-I�krtlen IIS;,. -STEL STEN STEF 41>;!lai o 1 o ISfi STE A e 155: 3'q 423 °122 e1;s L-0 '�' ,1 ISf:• t QCe e 157• ST 1551 15y, 'a I I.t ISen ISS: STE STE Iy� 15ty STEE STE G STE IN I:S 101 IS" I5:•. i 111 155] STE G :[�' j 701E e o 155:• 0 155: STEL 15:4 STE IGSo 0 15K ST �C STE E 117 1 4P - ISq; IS'i_ STE 105o 8 15 Sl- STow EIS o 155] STE F sr e- +so3 4• ! - ,ea 550 s24 501 4e2 � r'A e ISGS f✓' ' 3� e5so I es2J •soai eu2 °161 148 � 15 615 e 1485 a 1152 X47• WAACKJwE 1615 e1171 -- 1452 �5f7 R 1 19f 43 '4[4 -o I 1447 ( �1 •SIT •451 0471 °1161 3 ° I1JT N 1430 1 .-- 1425'' _— 14201—�} 1427 t °1425 •1420 11 °1127 5 x° .rte/.t -/39a hint DOW I T / 15/2]17 User- tporons Conditions Document 4 Panda Daycare Center - CZC - A-2017-0212 Exhibit B: Site/Landscape Plan (dated: March 17, 2017) a�nG cae� sp Fa Nusnxcsun,s ----- w "M2 (9,M SQ, Ft,) OM(VILLILAIC R/M �A� [ AREA aNLrns i f KEYNOTES 1 o� o� A - o oZ _ o�� Qi aPs+µossa �s pas�a O) c O� IyicrNtrymp m panda daycare Conditions Document 5 Panda Daycare Center - CZC - A-2017-0212 ( � 1w WE NDIANj =-•- Iranl�c> Planning Division CERTIFICATE OF ZONING COMPLIANCE Application Checklist Project name: MPA EMc440File #: Applicant/agent ALz- �Z.G.E(('tZAArc All applications are required to contain one copy of the following unless otherwise noted: ant App�l�i) Description Staff 4 X Completed and signed Development Review Application x !Narrative fully describing the proposed use of the property, including the following: for ➢ Information on any previous approvals or requirements the requested use (i.e., applicable conditions of approval or Develo went Agreement) ;Recorded•warrant deed -for the subject• ro er tl X Affidavit of Legal Interest signed and notarized by the property owner (If owner is a corporation, submit a copy of the Articles of Incorporation or other evidence to show that the person signing is an authorized a ent Scaled vicinity map showing the location of the subject property Stamped site plan fi•om Republic Services approving the details and location of the trash enclosure and access drive. Contact Bob Olson at ROlson a re publicservices.com or by �/� hone 208-685-7729 Civil Site/Dimension Plan - 1 full size co folded to 8 ''/i" x 11" size) lA A photometric test report for any light fixture(s) with a maximum output of 1,800 lumens I /X or more (see UDC 11-3A-11 Copy of the recorded plat the property lies within (8 'h" x 11'' ',Copy of address verification letter from Development Services. See attached request form 'Site Plan—*1 copy (folded to 8'/a" x 11" size) Plan must have a scale no smaller than I " = 50' (1 " = 20' is preferred) and be on a standard drawing sheet, not to exceed 36"x 48" (24"x 36" is preferred). A plan which cannot be draivn in its entirety on a single sheet must be drawn with appropriate match lines on two or more sheets The following items must be shown on the siteplan: • Date, scale, dimensions, north arrow, and project name (scale not less than I"=50') • Names, addresses, and telephone numbers of the developer and the person and/or X firm preparing the plan • Parking stalls and drive aisles • Location and detail of bicycle parking facilities • Trash and/or recycling enclosure(s) location • Detail of trash and/or recycling enclosure (nmst be screened on 3 sides) N Location and specifications for underground irrigation (Pressurized irrigation can only be waived if you prove no water rights exist to subject properL) • Sidewalks or pathways (proposed and existing) • Location of proposed building on lot (include dimensions to property lines) • Fencing (proposed and existing) X • Calculations table including the following: ➢ Number of parking stalls required and provided (specify handicap and compact stalls) ➢ Number of bicycle stalls required and provided ➢ Building size (sq. ft.) ➢ Lot size (sq. ft.) ➢ Setbacks ➢ Easement locations ,Reduction of the site plan 8 '/2" x I 1") Landscape Plan - *I copy (folded to 8 'h" x 11" size) " " be a standard Plan nnrst have a scale no smaller than 1 = 50'Ll = 20' is referred and on Community Development ■ Planning Division ■ 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www meridiancity.ora/planninQ (07/2512017) s i i Community Development ■ Planning Division ■ 33 E. Broadway Avenue, Ste. luZ Meridian, tdano 6.30'+L Phone: 208-884-5533 Fax: 208-888-6854 www trreridiancityorg[planninQ dravingsheet, not to exceed 36"x 48" (24"x 36" is preferred). A plat which cannot be drawn in its entireh, on a single sheet nnist be drawn with appropriate match lines on two or store sheets The following items must be included on the landscapeplan: RP• Date, scale, dimensions, north arrow, and project name � �(rr . Names, addresses, and telephone numbers of the developer and the person and/or l'tk firm preparing the plan �A, JCC • Stamp/signature of a landscape architect, landscape designer, or qualified nurseryman preparing the plan `r Existing natural features such as canals, creeks, drains, ponds, wetlands, 1 floodplains, high groundwater areas, and rock outcroppings • Location, size, and species of all existing trees on site with trunks 4 inches or greater in diameter, measured 6 inches above the ground. Indicate whether the tree will be retained or removed • A statement of how existing healthy trees proposed to be retained will be protected from damage during construction • Existing and/or structures, planting areas, light poles, power poles, walls, fences, berms, parking and loading areas, vehicular drives, trash areas, sidewalks, pathways, fire hydrants, stormwater detention areas, signs, street ftirniture, and other man-made elements µr� • Existing and proposed contours for all areas steeper than 20% slope. Berms shall ` be shown with one -foot contours • Sight Triangles as defined in 11-3A-3 of this ordinance • Location and labels for all proposed plants, including trees, shrubs, and ``'' (t�1( groundcovers (trees nmst not be planted in City water or sewer easements or within five feet of fire hydrants). Scale shown for plant materials shall reflect approximate mature size A plant list that shows the plant symbol, quantity, botanical name, common name, minimum planting size and container, tree class (I, II, or III), and comments (for s acing, staking, and installation as appropriate) • Calculations of project components to demonstrate compliance with the requirements of this ordinance, including: I" N� ➢ Width of street buffers, lineal feet of street frontage, and number of street trees ➢ Residential subdivision trees ➢ Acreage and percentage dedicated for common open space ➢ Acreage and percentage dedicated for qualified open space ➢ Number of trees provided on common lot(s) ➢ Mitigation for removal of existing trees Planting and installation details as necessary to ensure conformance with all {t� f+ required standards 14 Design drawing(s) of all fencing proposed for screening purposes. Include height and material Reduction of the landscape plan 8 '/2" x 11" Building elevations showingconstruction materials — *1 co folded to 8'h" x 11"size Reduction of the elevations 8 ''/2" x 11" Electronic version of the site plan, landscape plan, and building elevations in pdf format type (i.e. site submitted on a disk with the files named with project name and plan plan, landsca a lan, elevations, etc.. We encourage you to submit at least one color version If applying for approval of a public school, provide additional information as required by the Public School Facilitysupplemental checklist per §67-6519 'Fee (If this project had prior approval on a site plan, reduced fees may apply) For applications requiring a change of use or new construction we recommend you contact District at (208) 387-6170 to determine any fees or re emeirts x the Ada County Highwayuir For new ublie utility construction water, sewer, reclaimed water applicants are required to submit: (2) Sets of conceptual engineering plans including pipe sizes and profiles, in a format that for Drawings found at: P complies with the specifications project www. meridiancit .or / ublic works/autocad standardsliudex.as Community Development ■ Planning Division ■ 33 E. Broadway Avenue, Ste. luZ Meridian, tdano 6.30'+L Phone: 208-884-5533 Fax: 208-888-6854 www trreridiancityorg[planninQ (.- � � VIENI�IAN�-- ii)I-\4iO Planning Division DEVELOPMENT REVIEW APPLICATION STAFF USE ONL n Project name: File number(s): Assigned Planner: l( ot/1-,?5 Related files: Type of Review Requested (check all that apply) ❑ Accessory Use ❑ Planned Unit Development ❑ Administrative Design Review ❑ Preliminary Plat ❑ Alternative Compliance ❑ Private Street ❑ Annexation and Zoning ❑ Property Boundary Adjustment Certificate of Zoning Compliance ❑ Rezone ❑ City Council Review ❑ Short Plat ❑ Comprehensive Plan Map Amendment ❑ Time Extension: ❑ Comprehensive Plan Text Amendment Director/ Commission/Council (circle one) ❑ Conditional Use Permit ❑ UDC Text Amendment ❑ Conditional Use Modification ❑ Vacation: Director/Commission (circle one) Director/ Council (circle one) ❑ Development Agreement Modification ❑ Variance ❑ Final Plat ❑ Other ❑ Final Plat Modification Applicant Information Applicant name: At-,-' A44"I Phone: •sl�•Z�� 3 Applicant address: J j "sT, STlI s_ "%r �Fil Email: � Dw���• Curl City: t— State: %�� Zip: f33�fe Applicant's interest in property: IkOwn ❑ Rent ❑ Optioned ❑ Other Owner name: pj%Phone: Owner address: 21 Z -17,e `��''�� Email: City: &Z"i "mw State:1PAZip: r5Z•�' Agent/Contact name (e.g., architect, engineer, developer, representative): .0jjea Firm name: AL.CiA4A b Gw- we, Pho�nle:�1�514- *5 G Agent address: IL(1j V"✓1 !WV4? — Email: rl c, t K) e,at"r�+�1� � City: ykkle— State: X44111"� Zip: 933""= •` Primary contact is: ❑ Applicant ❑ Owner Agent/Contact Subject Property Information Location/street address: 15'SZ &0fS-rAA*41- M(J&ownship, range, section: SX11WIS Assessor's parcel number(s): 1Z5707.AW ZW Total acreagep . 141 Z! Zoning district: 1-'0 Community Development ■ Planning Division ■ 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.ore/planning I- (Rex 06112/1014) Project/subdivision name: m1 Imo`"''` y&LAe�' General description of proposed project/request: A "4Ax-y- 7wAArr iti*wAA&t'A-T' ) (A 601'0- .A Proposed zoning district(s): L^per Acres of each zone proposed: Type of use proposed (check all that apply): ❑ Residential ❑ Office PtCommercial ❑ Employment ❑ Industrial ❑ Other Who will own & maintain the pressurized irrigation system in this development? Which irrigation district does this property lie within? X14 Primary irrigation source: Secondary: Square footage of landscaped areas to be irrigated (if primary or secondary point of connection is City water): Residential Project Summary (if applicable) Number of residential units: Number of common lots: Number of building lots: Number of other lots: Proposed number of dwelling units (for multi -family developments only): 1 bedroom: 2-3 bedrooms: Minimum square footage of structure (excl. garage): Minimum property size (s.f): Gross density (Per UDC 11-1A-1): Acreage of qualified open space: _ 4 or more bedrooms: Maximum building height:. Average property size (s.£): - Net density (Per UDC 11-1A-1): Percentage of qualified open space: Type and calculations of qualified open space provided in acres (Per UDC 11 -3G -3B): Amenities provided with this development (if applicable): Type of dwelling(s) proposed: ❑ Single-family Detached ❑ Single-family Attached ❑ Townhouse ❑ Duplex ❑ Multi -family ❑ Vertically Integrated ❑ Other Non-residential Project Summary (if applicable) Number of building lots: _ Common lots: 1 Other lots: Gross floor area proposed: Existing (if applicable) Hours of operation (days and hours): &AA4 I o>,4-7 3 Building height: E-kt SP A16 Total number of parking spaces provided: �57 Number of compact spaces provided: Authorization Print applicant name: Applicant signature: Date: el. Z7./7 Community Development ■ Planning Division ■ 33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/plamrine -2- (Reu 06//2/20/4) September 27, 2017 November 2, 2017, revised ollabor ative City of Meridian Community Development — Planning Division 33 East Broadway Avenue, Suite 102 Meridian, Idaho 83642 Attn : Planner p. 208.884.5533 Re: Certificate of Zoning Compliance - Narrative To whom it may concern : We are proposing a Daycare Tenant Improvement within an existing building and partially within an existing tenant suite. There is a portion of the proposed Daycare Tenant Improvement that will encompass a portion of the existing building that has not been occupied, this space is described in the attached exhibits as Suite 'A'. Adjacent tenants are compatible with typical office space / use. Adjacent properties are solely single-family residential. The licensed daycare intends to accommodate 25 pre-school age children. The existing learning center (non -licensed) will accommodate another 48 children and adults. Within the facility there will be approximately 73 children and adults at maximum capacity. The main entrance to the Daycare will be along the West side of the existing Building, which is located very near (9) existing parking spaces, that can be utilized as the child drop-off zone. Adjacent tenants do not currently utilize the West side entrances of the existing building and therefore this area would be purposed solely for the Daycare use entrance. As part of the Daycare use, it is desired to have an outdoor play yard. This play yard would be located at the East end of the building in area of the site that is currently utilized as parking. The portion of the property where the play yard will be located is adjacent to residential uses and therefore requires a 20'-0" landscape buffer. A landscape buffer is shown on the updated site plan. Currently, a 6'-0" tall non -scalable fence exists along the Southern and Eastern property lines. In order to maintain delineation of the landscape buffer between the play yard and the residential properties we propose a shorter (4'-0" tall) interior chain-link fence. This chain-link would allow visual of the 20'-0" landscape buffer. The play yard would be accessible from with the proposed tenant suite and we would provide a new 6'-0" tall visually solid fence with gate to the existing exterior sidewalk. A detail of the chain-link and solid fence are provided for reference. We plan to provide a more suitable play surface, by removing the existing asphalt or by covering the existing asphalt, surfacing at this time is undetermined, however we are planning to provide a rubberized mulch to soften the surface of the asphalt. Within the play yard the tenant does not intend to have play equipment that is taller than 6'-0" in height and therefore play equipment is not indicated on the proposed site plan. ALC ARCHITECTURE ❑ 1119 EAST STATE STREET ❑ EAGLE, IDAHO 83616 Should you have any questions or concerns regarding this response letter please feel free to contact me at your earliest convenience. We thank you for your time and consideration for this project and look forward to your approval. Thank you Richqfd Wilmot- Project Manager ALCjkrchitecture richardw@alcarchitecture.com 208.514.2713 sm Rubberized Playground Surface — Cut Sheet Floor Plan and Site Plan, dated 11.01.17 ALC ARCHITECTURE ❑ 1119 EAST STATE STREET ❑ EAGLE, IDAHO 83616 LA } Q ) < B < � ;( *\\ (- §§()$ 00000Geeee0G@@ee m OV � A � a ADA COUNTY RECORDER Christopher D. Rich AMOUNT 10.00 1 BOISE IDAHO 10/09/2013 04:21 PM r�tine>�£0�►Or DEPUTY Bonnie Oberbillig ' o n t v r. u [ r r n n Sinrplifile Electronic Recording I IIIIII VIII I'I'I VIII IIIIII II IIIIIIII VIII VIII III VIII III) IIII RECORDED -REQUEST OF J 5680 E. franklinRd.,Ste. 250 PIONEER TITLE COMPANY OF ADA C 113113940 Nampa, ID 83687 ELECTRONICALLY RECORDSD.DO NOT REMOVE THE COUNTY STAMPED FIRST PAGE AS IT 18 NOW INCORPORATED AS PART OF THE ORIGINAL DOCUMENT 1: €le No. 538528 CORPORATE WARRANTY DEED FOR VALUE RECEIVED, Idaho Banking Company a corporation duly organized and existing under the laws of the State of , Grantor, does hereby Grant, Bargain, Sell and Convey unto Bornal Associates, LLC, a California. Limited Stability Company Grantee, whose address is: 5000 Pleasanton Ave, ft'1l0 Pleasanton, CA 94566, the following described real estate, to -wit: Lots 2 and 3 in Took I of Midtown Square Park No 2, according to the plat thereof, filed in Book 76 of Plats at Pages) 7996-7997, records of Ada County, Idaho. SUBJECT TO ourrent years taxes, irrigation district assessment, public utility easements, subdivision, restrictions, U.S. patent reservations, easements of record and easements visible upon the said premises. TO HAVE AND TO BOLD the said premises, with their appurtenances unto the said Grantee, his heirs and assigns forever. And the said Grantor does hereby covenant to and with the said Grantee, that it Is the owner in fee simple of said premises; that they are free from all encumbrances and that it will warrant and defend the same from all lawful claims whatsoever. IN WYINESS WHISREOF, the Grantor, pursuant to a resolution of its Board of Directors has caused its corporate name tobe ere -unto subscribed by its officers this October 8, 2013. Idah� 'ng By: NIML. Ba ecial Assets State of Idaho, County of Canyon On this i day of October in the year of 2013 before me, the undTrsigned, a Notary Public in and for s�i�State, persogpily ppeared �f/�� gc Tcnown or identified to me to be the V r.G(� S - of the corporation that executed tho instrument or the person/persons who excoutefl the Instrument on bph if of said corporation, and acknowledged to me that such corporation executed the same. Commission E-xP`i1,0S: -.. 7-'t a (1) Disk with electronic version of the conceptual engineering plans in the format specified bove. . AFMAVIT OF LEGAL INTEREST STATE OF I)DA)ll<U } } COUNTY OF ADA ) I, CV0 tlee-rwt 2A 2-1 2-71-4-1— 1-L lam✓ ff t (e,x�..x. (address) —_� �—.�.ity) (state) being first duly sworn upon, oath, depose and say: 1. That I am the record owner of the property described on the attached, and I grant my permission to: 1117 it> y $ 3�� ..' (name) (address) to submit the accompanying application(s) pertaining to that property. 2. 1 agree to indemnify, defend and hold the City of Meridian and its employees harmless from any claim or liability resulting from any dispute as to the statements contained herein or as to the ownership ofthe property which is the subject of the application. I hereby grant permission to City of Meridian staff to enter the subject property for the purpose of site inspections related to processing said application(s). Dated this day of , 20-/-_ (Signa �' SUBSCRIBED AND SWORN to before me the day and year first above written. (Notary Public for Idaho) r Residing at: _. My Commission Expires: Community Development • Planning Division r 33 B. Broadway Avenue., Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 pax: 208-888-6854 wwSv.mendiauoitv,oref nin ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validitv of that document. State of California County of Alameda On 09/21/2017 before me, Ricky Diefenderfer (insert name and title of the officer) personally appeared Craig C Sjoberg who proved to me on the basis of satisfactory evidence to be the subscri ed to the within instrument and acknowledged o e that tf (he it authorized capaclty(i s), and that by / eir sig perscffi/tA, or the entity upon be if of which the person acted, whose nam i Bey executed the sadne in on the instrument the the instrument, I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature (Seal) ���ititiY Ot�Eti CommiWOO 0 2130352 NO" Pak - cal"Ownwok, M'i�Ot a f fret 4011 2019+ M 0 N N 1S FIfaZ ('AN M CO IS Ppb MN C*1 4R CL fIf L f) IS till' MN IS 'lit PAN IS LIMCIIpil^1 N .1 r( ;Y U _r Gtie� � •f - o I �I a I IS Il1L 1AN i17 2iepurne i N rn i 3S 1118 WN 0 0 0 0 > r `v v O n 3 N cc x Gni T Co OC) I a U M J t El 1:1 0 N N 1S FIfaZ ('AN M CO IS Ppb MN C*1 4R CL fIf L f) IS till' MN IS 'lit PAN IS LIMCIIpil^1 N .1 r( ;Y U _r Gtie� � •f - o I �I a I IS Il1L 1AN i17 2iepurne i N rn i 3S 1118 WN Y N J Q Z O W O Q Z'�I2Z�mD _� 5 0 ;0 w�0 a�w�FMQ �Y ZF-Q Q O O M W 0 � O 0-1 J O q � F F _ 3 zZ - s F � z W Q 00 N 3 Z CY) €.A =o Z U CY) z a mm JI m II I�� I Y N J Q Z O W O Q Z'�I2Z�mD _� 5 0 ;0 w�0 a�w�FMQ �Y ZF-Q Q O O M W 0 � O 0-1 J O q 'W'8 •'3'l'N •'N'£'1 C1+ 14.8 •'MT8 •'NT'1 0 y66 � •�� U S yi i1 I m a 4� 2 Oj � F I fi 5 i� nw I o al I"In' bo s n8 oa0 / O 8g o y / / n i I I N ar-TT_— s w� 1ZI O ?I I ww m J 99l M SZ 90.00 S I - UI Loo olI c o I H ;oo.mt 3-00,00.00 s I o d N I w j p o I I 91999CS61 '1SN11 I I N �.j vi� �< 1N3Y135V3 tl3HOd pV, z Im o tI�l Nmul OHVO S 0018'24' E 109.76' I'�Iri W 9999056/ '1SNI 1N3Y13SV3 I Z I. 934Od OHVOI OZ ONLLSIX3 �o I of O Y 00'00'00 E _145: 4. 1 NI O I J ri-i - �I ISI O^ ISI w 3 I_I Im1 I' wl lel I I�� I of ldl IPa I wl qlI INS ml ISI �I0 Z,i olo z ll w< / WNi Oo awe 3 s 1 z I\\\ \ I z l w I wl \\ tis 3 m " gry 21 p x a I ml I I I � 0 �_9i60 i2 � m w � w N i WNz LU"i m wOz a� o \ o i UN 5 S� iW g 5�� �F miO ` � x a I ro o w w0O\ 8 i W9 Pw� �� ' «o zJ �w S :�'<-� E -Z a . 1 JL, H O i c— Q R �+- 0 is 1k,'yo . o y%dss J w �� p � u nFp gyp` �w 8-- 49 of w Coln <wo 5 0 t✓,9ni o ;Nrc ��< V aF aw zy�� yzN 5 g oS- zm <+ F a< Z�' P yKK oiw 0 0� U NF 0300 5f'.1'. U ~U''SmZ Po ZJ Via ?'z �«o Ux h0 N< 36 €� Uw ylw O _ yyNU� F� ryOjn �0 w SZ JWP` ws U a� amo, 90 oW 7h z5 a� s R n" 0 v 44 mU <3K45< 0< D w0< O'U, � • 3 zZ O $n? Fn z W Q 00 N 3 Z CY) €.A =o Z U CY) z a mm JI m m m < ZD _ _ �u • 'W'8 •'3'l'N •'N'£'1 C1+ 14.8 •'MT8 •'NT'1 0 y66 � •�� U S yi i1 I m a 4� 2 Oj � F I fi 5 i� nw I o al I"In' bo s n8 oa0 / O 8g o y / / n i I I N ar-TT_— s w� 1ZI O ?I I ww m J 99l M SZ 90.00 S I - UI Loo olI c o I H ;oo.mt 3-00,00.00 s I o d N I w j p o I I 91999CS61 '1SN11 I I N �.j vi� �< 1N3Y135V3 tl3HOd pV, z Im o tI�l Nmul OHVO S 0018'24' E 109.76' I'�Iri W 9999056/ '1SNI 1N3Y13SV3 I Z I. 934Od OHVOI OZ ONLLSIX3 �o I of O Y 00'00'00 E _145: 4. 1 NI O I J ri-i - �I ISI O^ ISI w 3 I_I Im1 I' wl lel I I�� I of ldl IPa I wl qlI INS ml ISI �I0 Z,i olo z ll w< / WNi Oo awe 3 s 1 z I\\\ \ I z l w I wl \\ tis 3 m " gry 21 p x a I ml I I I � 0 �_9i60 i2 � m w � w N i WNz LU"i m wOz a� o \ o i UN 5 S� iW g 5�� �F miO ` � x a I ro o w w0O\ 8 i W9 Pw� �� ' «o zJ �w S :�'<-� E -Z a . 1 JL, H O i c— Q R �+- 0 is 1k,'yo . o y%dss J w �� p � u nFp gyp` �w 8-- 49 of w Coln <wo 5 0 t✓,9ni o ;Nrc ��< V aF aw zy�� yzN 5 g oS- zm <+ F a< Z�' P yKK oiw 0 0� U NF 0300 5f'.1'. U ~U''SmZ Po ZJ Via ?'z �«o Ux h0 N< 36 €� Uw ylw O _ yyNU� F� ryOjn �0 w SZ JWP` ws U a� amo, 90 oW 7h z5 a� s R n" 0 v 44 mU <3K45< 0< D w0< O'U, r I I Is I u■■ �■■■■■� Y I I� w I U I J I I I I ulIV I I I n —mss I 19- ILL I I I 1 e _ z U 0 0 4 U n z F) u■■ �■■■■■� monsoon .■..i U n z F) ...�O ro in U n z F) RUBBERBOND" looks like traditional poured -in-place, but that's where the similarity ends. RUBBERBONDT" is a revolutionary patent pending unitary surface whose safety surpasses all other poured -in-place surfaces. Its unrivaled 16'fall height protection sets the bar on safety and accessibility at no additional cost. Our unique hybrid system combines the superior safety ratings associated with loose -fill systems with the accessibility, low -maintenance and design options that a unitary surface provides. RUBBERBOND's compacted, no binder cushion layer formula is patent pending, softer, safer, longer lasting and environmentally friendly. • THICKEST WEARCOURSE IN THE INDUSTRY • 100% RECYCLED • COST-EFFECTIVE • REMAINS SOFT YEAR AFTER YEAR • MAINTENANCE -FREE • ADA ACCESSIBLE RubberBond Vs. Traditional Poured -in -Place Description Traditional P.I.P. RubberBond Wear Course Thickness Overall Thickness Average HIC Ratings Average Fall Height Rating Weight Per Sq.Ft. Warranty 3/8 -1/2" 2-31/2" 800 plus 6-8' 5 - 7 pounds 5 years 11/2" 51 /2" 400 16' 15 pounds 5 Years COLORS TAN 1 LIGHT BLUE Summary 200% Thicker 50 -175%Thicker 50% Better safety performance More than double the fall height performance More than twice the material used Same standard warranty A RUBBERECYCLE i COMPANY PLAYS FER, D � � Technical Specifications Test Description ASTM Reference Results Test Lab Test Date Impact Attenuation F1292 Refer to chart below TUU America 03-15 Permeability F1551 2245.5 inches/hour TSI 03-11 Slip Resistance C1028 0.74 wet/0.55 dry TSI 03-11 Tear Strength D624 4.5 lbs/force TSI 03-11 Peak Tear Load D624 2.6 lbs/force TSI 03-11 Tensile Strength D412 13.5 psi TSI 03-11 Elongation D412 14.6% TSI 03-11 Flammability D2859 Pass TSI 03-11 Critical Fall Height Reference Chart — Impact Attenuation ASTM F1292-13 Specified Impact Height Feet 6 8 10 12 14 15 16 Reference Temp 23 C (73.4 F) G -Max NIC 37.5 107 51 183 58.5 277 67 395 107.5 767 113 822.5 119.5 902 Reference Temp 49 C (120.2 F) G -Max HIC 43.5 126 54.5 210 61 270.5 69.5 367 88.5 577,5 97 656 110.5 808.5 .% 0,0, RubbeRecycle Recycled Rubber Products Reference Temp -6 C (21.2 F) G -Max HIC 49 160 62 276.5 70.5 337.5 72 382 111 728.5 125.5 899.5 132 942.5 Rubberecycle, LLC 1985 Rutgers University Blvd., Lakewood, NJ 08701 Phn: 888-436-6846 • Phn: 732-363-0600 • Fax: 732-370-4247 • Email: info@rubbermulch.com QJ0'c, AYSUg14. IPEMA CERTIFIED ASTM P1292 , Tom[ µ�oaodo.,unmgoo, vla ww.Ipe —g