Loading...
CC - Revised Site Plan and Street LightingE P E P E P E P E P E P E P E P E P E P E P E P E P D D D D D D SD SDN. PENNGROVE WAY N . P E N N G R OVE WAY M C M I L L A N R O A D LINDER ROAD (SCALE IN FEET) 1:30 (22x34 FULL SIZE)30 15 90300 SITE PLAN & STREET LIGHTING PLAN 60' x 90' 5,400 SQ. FT. 60' x 100' 10,000 -12,000 SQ. FT. TWO STORY BUILDING 60' x 100' 6,000 SQ. FT. CROSS ACCESS EASEMENT UTILITY EASEMENT CROSS ACCESS EASEMENT UTILITY EASEMENT 29.59' 30.00' 30.00' 30.00' INTERSECT EXISTING ACCESS EASEMENT 135°' DEVELOPED LOT EXISTING UTILITY EASEMENT 25.00' 19.01' 9.00' MIN 50' x 84' 4,200 SQ. FT. 50' x 66' 3,300 SQ. FT.46' x 82' 3,772 SQ. FT.29.59' 25.00' 9.54' 8.68' 4.77' 36.54' 5 8 6.00' 8.33' 29.67' 34.16' 25.41' 18 5 7 30.21' 23.76' 4.04' 30.18' 25.41' 23.76' 30.02' 10.00' 25.00' 24.01' 6.00' 25.00'5 10.00' 7.00' 7.00' 20.00' 30.00' 10.00' 11 35.42' 8 3 11 31.91' 4.77'10.00' 25.01'25.01' 10.00' 6.09' 5.03' 11 4 17.41'16.87'16.11'18.88' RETAINING WALL 34.61'33.60' 6.86' 25.09' 24 25.01' 38.00'25.09'25.01' 10.07' 25.03' 10 10 35.02' 4.77'23.76' 6.12' 25.03' 19.01' 5 11 9.50' 27.59' 27.59' TRASH ENCLOSURE RE:CS-501 TYPE 1, 35' STREET LIGHT, TYP T Y P E 2 S T R E E T LI G H T , T Y P 5.50' 5.00' NEW PEDESTRIAN RAMP PER ISPWC SD-712C TYP NEW SIDEWALK PER ISPWC SD-709 NEW 10' STREET BUFFER ALONG N PENNGROVE WAY November 2017 PL O T T E D B Y : CA L E B K E N Y O N DA T E P L O T T E D : 11 / 2 / 2 0 1 7 6 : 1 9 : 5 0 P M PA T H : A: \ A B C O E N G I N E E R I N G \ J O B S L A N D E D \ 1 6 - 4 4 3 3 Z - - L I N D E R P R O F E S S I O N A L P L A Z A S U B D I V I S I O N ( M C C A R T E R M O O R H O U S E ) \ 0 0 A B C O C A D \ 1 6 - 4 4 3 3 Z - 0 3 - C S - 1 0 1 . D W G FILE NUMBER: SHEET NUMBER: DESIGNED BY: DATE DE S C R I P T I O N DA T E RE V I S I O N S BY NO . DRAWN BY: AB C O EN G I N E E R I N G 2101 Delta Drive Nampa, Idaho 83687 Phone (208) 955-8126 N. L I N D E R R O A D C. Kenyon CS-101 ME R I D I A N , I D A H O SI T E P L A N MC C A R T E R M O O R H O U S E , L L C 4 OF 11 AD A C O U N T Y LI N D E R P R O F E S S I O N A L P L A Z A S U B D I V I S I O N H.White 16-4433Z LEGEND MAJOR CONTOUR LINE MINOR CONTOUR LINE CENTER LINE EDGE OF PAVEMENT EDGE OF GRAVEL FENCE LINE GAS LINE OVERHEAD POWER LINE PROPERTY LINE UTILITY EASEMENT LINE SEWER LINE TELEPHONE LINE WATER LINE PRESSURE IRRIGATION LINE CROSS ACCESS EASEMENT LINE STORM DRAIN LINE GRADE BREAK LINE BENCH MARK BM ELEVATION EL EXISTING EX FINISH GRADE FG FINISH FLOOR FF GRADE BREAK GB INVERT INV MATCH MA NATURAL GROUND NG RADIUS R REBAR CAP RC RIM OF FEATURE RIM TOP OF CONCRETE TC TOP OF PAVEMENT TA TOP OF RETAINING WALL TW BOTTOM OF RETAINING WALL BW WATER METER WM NUMBER OF PARKING SPACES ASPHALT PAVEMENT CONCRETE EP EP EG EG X X GAS GAS OHP SS SS TEL TEL W W PIRR PIRR CALL BEFORE YOU DIG! 1.THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALL UTILITY COMPANIES OF THE CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE WHICH MAY OCCUR BY FAILURE TO EXACTLY LOCATE AND PROTECT ALL UTILITIES. 2.CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY EARTH DISTURBING ACTIVITIES ON SITE, AND REQUEST LOCATE OF UNDERGROUND UTILITIES. *The 811 logo is a registered trademark of the CGA. Know what's below. before you dig.CallR SD SD ## 1 1 1 / 1 7 C K C I T Y C O M M E N T S