Loading...
Landscape PlansLANP5C,APE REaUIREMENT5: • PER CITY OF MERIDIAN GORE BUFFERING 4 5CREENING: *PROVIDE A MIX OF MATERIALS, TREES SHALL TOUGH AT MATURITY; ALONG PROPERTY LINES OF INCOMPATIBLE USES • BUFFER ADJACENCY LENGTH TREES REQ'D TREES PROV'D • NORTH -W AG -RUT 665 1 5 (45'W) 0 (SEE BELOW) • NORTH -E 5AME U5E N/A N/A N/A • EA5T-N SAME USE N/A N/A N/A • EA5T-5 RES 335 10 10 (2 EXI5TIN6) • SOUTH SAME USE N/A N/A N/A • WE5T 5EWER N/A N/A N/A NOTE: *NO TREES ON NORTH PERIMETER ADJACENT AG -RUT PER IRRIGATION LINE, LARGE SHRUB5 IN LIEU MINIMUM PLANT SIZES: PLANT TYPE: MINIMUM SIZE *SHADE TREES: 2" CALIPER *CONIFER TREES: 6HIGH *WOODY SHRUBS: 2 GAL ADDITIONAL REQUIREMENT5: *"TREES SHALL NOT BE PLANTED WITHIN 1 O' OF ACHD STORM DRAIN PIPE, STRUCTURES OR FACILITIES", or 1 O' WITHIN A FIRE HYDRANT *5EEPA6E BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM *NO TREES OR SHRUBS OVER 36" HIGH SHALL BE PLANTED WITHIN THE 40'X40' CLEAR VISION TRIAN6LE5 AT INTERSECTIONS NOTE5: 1. DO NOT DAMAGE OR GUT LEADER 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. 3. TREE 5TAKIN6 SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP 3 OF THE ROOTBALL. 6. 5DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3" OF MULCH MIN. DO NOT PLACE MULCH WITHIN 2" OF TRUNK OF TREE. 7. ALL LARGE AND ORNAMENTAL TREES TO RECEIVING 5TAKIN6 PER DETAIL 1 /L 1. 10 TOP TWO STRUCTURAL ROOTS: <3" BELOW TOP OF ROOTBALL LOWEST STRUCTURAL ROOT <5" BELOW TOP OF ROOT BALL 501L SAUCER >3" HI6 REMOVE AT END OF PROJECT GUT AND FOLD WIRE BASKET FROM TOP ROOTBALL =T VISIBLE ABOVE 501L LINE NE OF THE TOP OF :OOT BALL AFTER ,/INC EXCESS SOIL. 2-3" OF MULCH BACKFILL MIX 5EE NOTES AND SPECIFICATIONS. c.vMPAG 1501E UNDER ROOTBALL TO q0010 PROCTOR. BALL AND BURLAP TREE PUNTING 3/4" = 1'-O" 329343.33-05 LANPSCAPE NOTES: 1. REGULATIONS $ STANDARDS 1.1. All contractor work shall be conducted in accordance with I5PY4G (Idaho Standard Public Works Gonstruction), 201-7; and City of Meridian, ID codes, standards and state and local regulations. 2. EXISTING CONDITIONS 2.1. All utilities shall be located prior to construction and protected. Any damage to structures, utilities or concrete will be replaced at contractor's expense. 2.2. The site has many existing improvements such as underground utilities, curb and gutter, light poles and sidewalks. 3. GRADING a 51TE PREPARATION 3.1. Prepare finish grades for planting by grubbing and removing weeds. If necessary apply Round -Up (or equivalent herbicide), using a certified applicator. Remove rocks and other materials over 2". 3.2. All gravel overprep to be removed and disposed of off site. 3.3. Finish grade to be smooth transition to allow for entire site to be a natural flowing space. 3.4. Fine grade lawn areas to elevations set by Engineer's plans with positive drainage away from structures. 3.4.1. Refer to Engineer's plans for grading information a for all drainage pipes and locations. Protect and retain drainage at all times. 3.5. No pooling or standing water will be accepted per industry standards. 4. SOILS 4.1. All planter beds to receive a minimum of 15" depth of screened topsoil. Spread, compact, and fine grade to smooth and uniform grade 2" below adjacent surfaces. 4.2. All lawn areas to receive a minimum of 1 2" depth of screened topsoil. Spread, compact, and fine grade topsoil to a smooth uniform grade 1 " below adjacent surfaces. 4.3. Reuse of existing topsoil that has been stockpiled on site is permitted if: 4.3.1. Topsoil is tested and analyzed to ensure a proper growing medium. Provide additional NOTES: REMOVE ALL TAGS, TWINE OR OTHER NON BIODEGRADABLE MATERIALS ATTACHED TO PLANT OR ROOT MASS. PLANT PIT HOLE TO BE MIN 6" WIDER AND 6" DEEPER THAN NURSERY CONTAINER FOLD BURLAP FROM TOP OF ROOT BALL DOWN INTO GROUND; SET TOP OF BALL FLUSH WITH FINISH GRADE 1 2" TO 1 8" FOR LARGER SHRUB ROOT BALLS, MAKE DEPTH MIN. 4" DEEPER THAN BALL) SOIL SURFACE— R000HENED TO BIND WITH NEW SOIL SHRUB PUNTING 1 " = 1 '-O" BACKFILL SHALL BE 100% TOPSOIL. WATER SETTLE ALL PLANTINGS TO ENSURE PLANT ROOTBALL MAINTAINS 2" HEIGHT ABOVE EXISTING SOILS WHEN COMPLETE. PLANTER FERTILIZER TABLETS SET 3" BELOW GRADE, APPROVED BY OWNER AND/OR MAINTENANCE COMPANY. 3" BELOW GRADE, QUANTITY PER PLAN & SPECS. MULCH 2" MIN. AWAY FROM TRUNK OF PLANT. 3" DEEP MULCH MIN. LAWN OR PAVING BALL AND BURLAP PLANT (IF CONTAINER - GROWN PLANT WITH ROOTS L005ENED AND PULLED OUT TO PREVENT PLANT FROM BECOMING ROOT BOUND) 329333.16-01 amendments as determined by soil tests. And 4.3.2. Topsoil is to be loose, friable sandy loam that is clean and free of toxic materials, noxious weeds, weed seeds, rocks, grass or other foreign materials. 4.3.3. Topsoil should have a ph of 6.5 to 8.0. 4.3.4. If onsite topsoil does not meet these minimum standards contractor is responsible for providing approved imported topsoil or improving onsite topsoil per the approval of the project manager. 4.4. If imported topsoil is used it must be from a local source and be screened free of any debris or foreign matter. Topsoil must not contain rocks, sticks, lumps, or toxic matter. 4.5. Smooth, compact, and fine grade topsoil in lawn areas to smooth and uniform grade .5" below adjacent surfaces. 4.6. Prepare finish grade of topsoil to elevations set by Engineer's plans with positive drainage away from structures. Refer to Civil Engineer's plans for grading information. 4.7. Amend all new plantings with 2 parts topsoil and 1 part compost. 5. PLANTER BED MULCH 5.1.1. 2" depth of black and tan mini or approved other. install over commercial grade weed -barrier fabric, per manufacturer recommendations. 6. LAWN AREAS 6.1. Sodded, to be tall turf -type fescue or approved equal per approved by owner, regionally grown, provide same mix as seeded or approved equal (above), to be installed 6 weeks min prior to opening date. 6.2. Lay sod within 24 hrs of harvesting. Lay sod to form a solid mass with offset, tightly fitted joints on even grades. 6.3. Strip, repair and replace dead sod as needed 6.4. All lawn areas to have cut edge. 7. PLANTS 7.1. All plant material shall be installed per industry standards. 7.2. All plant material shall meet or exceed the minimum federal standards as regulated by ANSI z60. 1, American Standard for Nursery Stock. Plants not meeting these standards for quality, or plants determined to be unhealthy by Owner's representative, will be rejected. 7.3. All Ball and Burlap trees to be installed per Balled and Burlapped planting detail 1 /L 1.00. 7.4. All shrubs to be installed per detail 2/L 100. 7.5. Trees and shrubs over 36" shall not be planted within clear vision triangles per city code. 7.6. Fertilize all trees and shrubs with 'Agriform' planting tablets or approved equal. Apply per manufacturers recommendations. 7.7. All landscape trees shall be pruned in accordance with the American National Standards. (Latest Edition ANSI A300) 8. IRRIGATION 8.1. Irrigation system shall be built to the following specifications: 8.1.1. Adhere to city codes when connecting to city water. 8.1.2. All irrigation material to be new with manufacturers' warranty fully intact. 8.1.3. Install outdoor rated controller to be located as indicated on plan; coordinate with project manager and site electrician on exact location. 8.1.3.1. Controller to have On/Off rain switch or rain shut off device that does not alter program. Install in steel lock box with (2) keys. 8.1.4. All remote control valves (including master control valve) to have flow control device. 8.1.5. Irrigation system piping to be minimum class 200 PVG or approved equal, sleeves to be double the size of pipes located within, all wires to be contained in separate sleeves 1 - 1 /2" dia min. 8.1.6. Use common trenching where possible.. 8.1.7. All PVC located under hardscapes to be schedule 40 PVG with same req's as above. 8.1.8. All mainline pipe and wires to be buried a minimum of 15" and all lateral piping to be buried a minimum of 1 2" below grade. 8. 1.q. All wires to be 14 gauge direct bury wire at a minimum. Size wire for correct voltage loss. 8.1.10. Supply a minimum of (2) spare wires to PLAN O\/ER\/IEYN couNTP RUT furthest valves from controller in all directions. 5.1.11. Sprinkler heads shall have amatched precipitation within each control circuit. Velocities shall not exceed 5 feet per second. 5.1.12. Gontractor is responsible complying with all codes and paying all permits necessary. 8.1.13. Sprinkler heads shall have matched precipitation within each control circuit. Velocities shall not exceed 5 feet per second. 5.1.14. water schedule to be provided at a min of 80010 evapotranspiration as determined by the local ET. 5.1.15. Install all irrigation per irrigation drawings. utilize material specified or approved equal. 5.1.16. All landscaping areas shall be provided with an undergroud irrigation system. Landscaping shall be maintained according to current accepted industry standards to promaote good plant health, and any dead or diseased plants shall be replaced. all landcsape areas with shrub shrubs shall have an approved mulch such as bark or soil aid. q. CONTRACTOR RESPONSIBILITIES q. 1. Gontractor i5 responsible for 1 year of maintenance starting at the final date of acceptance by owner. q.2. Estimated quantities are shown for general reference only. Contractor shall be responsible for all quantity estimates. C1.5. Refer to note 2.1 regarding damages to existing utilities a permitting note in Irrigation section. q.4. All plant material and workmanship shall be guaranteed for a period of one year beginning at the date of Acceptance by Owner. Replace all dead or unhealthy plant material immediately with same type and size at no cost to Owner. q.5. Landscape contractor to turn in as built drawings at the end of project. Substantial completion will not be granted until 2 copies @ 1 "=20' scale are turned in and approved by owner's representative. 10. In the event of a discrepancy, notify the General Gontractor. THE GRAPHICS AND DESIGN5 ON THIS SHEET ARE DELIVERABLES THAT REMAIN AT ALL TIMES PROPERTY OF STACK ROCK GROUP, INC. _- REPRODUCTION OR REUSE OF THIS s PRODUCT CONTAINED HERE IN IS PROHIBITED S T A C K R 0 C K CONSENT OFWITHOUT THE WRITTEN STAK ROCK &ROUP, INC. GROUP ®2016 STACK ROCK GROUP, INC. STAGK ROGK GROUP, ING. LANDSCAPE ARCHITECTURE/ MASTER PLANNING W W W.STACKROCKG ROUP.GOM Maxey TookeyArchitects, L.L.P. 1412 W. IDAHO ST, SUITE 210 Boise, Idaho 83702 PHONE,- (208) 344-9600 hto.//www.maxey-tookey.corn chuck@maxey-tookeycom PRELIMINARY .0%0,11111111111", 0FIIj ' 9 o 7.2 5.17 G NOT FOR CONSTRUCTION Q0 0 N 000 00 (D a M 0 M o E 21m^ OU 0 00 0U) U Q 0 N x E a D Z � B � 4- C14 > > I v 0 m N 0 � O O O E N LTJ C) L `� N O IV a- 0 O 0 1F' w J Q U N z o} _ m Q LLJ Y O W U LTJ O _ I� (f) a 0 zZ N L Q N 0 Z O } �=Z m LLJ O Z m ry O 0~ O a W D O 0 0 J JOB #: FBC# ??? JOB #: MTA #1701 ISSUE DATE: 5-15-17 ISSUE: DESIGN REVIEW SHEET: L 1.00 OF SHEETS PLANT SCHEPULF— TREES BOTANICAL NAME / COMMON NAME CONT GAL 2 QTY 0 Gledit5ia triacantho5 inermi5 'Skycole' TM / Skyline Thornless Honey Locust 45'W x 35'W B & B 2"Gal 6 8 SHRUBS BOTANICAL NAME / COMMON NAME SIZE FIELD2 9 QTY 10 Gornu55ericea / Red Twig Dogwood 9'H x 5'W 2 gal 55 Prunus laurocerasus 'Otto Luyken' / Luykens Laurel 4'H x 8'W 2 gal 54 REFERENCE NOTES SCHEDULE CODE I7E5GRIPTION 1 5TORAGE BUILDING, SEE ARCH 2 STORMWATER DETENTION POND, SEE CIVIL 3 FIRE HYDRANT, TYP, SEE GIVIL 5 DRAINAGE STRUCTURES 8 FACILITIES, 5EE CIVIL 6 ROCK MULCH IN THIS AREA ONLY, OVER FABRIC, NO IRRIGATION ON SHARED SAME USE PERIMETER -7 FENCE, SEE CIVIL 8 EXI5TING TREES, PRESERVE AND PROTEGT, NO WORK WITHIN CRITICAL ROOT ZONE LIMITS 9 RE5EED TO NATIVE HERE 10 REVEGETATE TO NATIVE ONLY AS NEEDED I -r- -�- I I v �o I 2 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I STACK ROCK GROUP THE GRAPHICS AND DESIGNS ON THIS SHEET ARE DELIVERABLES THAT REMAIN AT ALL TIMES PROPERTY OF STACK ROCK GROUP, INC. REPRODUCTION OR REUSE OF THIS PRODUCT CONTAINED HERE IN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF STACK ROCK GROUP, INC. @201 6 STACK ROCK GROUP, INC. STACK ROCK GROUP, ING. LANDSCAPE ARCHITECTURE/ MASTER PLANNING W W W.STACKROGK6ROURGOM FAI Maxey TookeyArchitects, L.L.P. 1412 W. IDAHO ST, SUITE 210 Boise, Idaho 83702 PHONE: (208) 344-9600 &P.//wwwmaxey-tookey. com chuck@maxey-tookey. com PRELIMINARY 000III fill,, . `S OF I �• =* v y - d - -1 3 7.2 5.17 NOT FOR CONSTRUCTION O N 00cm O 00 a o m O 2' m^0 l0 O cn O C a O N X z N li -0 QN Z3 Un o p O 4- C'4 o m N 4- I0 N O 41 o c O 0^0 E ON W o L � N p N a- 0 O L 00 m I� �.i J Q U U) + z om _ m QLd OY U w I I U O J I� c a D z z c� LLJa N a: �0 z O } Z m � 0 z m O F7 - a --D w D o p U J JOB #: FBC# ??? JOB #1 MTA #1701 ISSUE DATE: 5-15-17 ISSUE: DESIGN REVIEW SHEET: L1.01 OF SHEETS PLANT SCHEPULF- TREES BOTANICAL NAME / COMMON NAME CONT GAL 2 0 Gledit5ia triacantho5 inermi5 'Skycole' TM / Skyline Thornle55 Honey Locust 45'W x 35'W B & B 2"Gal DRAINAGE STRUCTURES 8 FACILITIES, 5EE CIVIL SHRUBS BOTANICAL NAME / COMMON NAME SIZE FIELD2 i EXI5TING TREES, PRESERVE AND PROTEGT, NO WORK WITHIN CRITICAL ROOT ZONE LIMITS Gornu55ericea / Red Twig Dogwood 9'H x 5'W 2 gal 10 ! Prunus laurocerasus 'Otto Luyken' / Luykens Laurel 4'H x 8'W 2 gal ! REFERENCE NOTE5 SCHEDULE CODE I7E5GRIPTION 1 5TORAGE BUILDING, SEE ARCH 2 STORMWATER DETENTION POND, SEE CIVIL 3 FIRE HYDRANT, TYP, SEE GIVIL 5 DRAINAGE STRUCTURES 8 FACILITIES, 5EE CIVIL 6 ROCK MULCH IN THIS AREA ONLY, OVER FABRIC, NO IRRIGATION ON SHARED SAME USE PERIMETER -7 FENCE, SEE CIVIL 8 EXI5TING TREES, PRESERVE AND PROTEGT, NO WORK WITHIN CRITICAL ROOT ZONE LIMITS 9 RE5EED TO NATIVE HERE 10 REVEGETATE TO NATIVE ONLY AS NEEDED STACK ROCK GROUP THE GRAPHICS AND DESIGNS ON THIS SHEET ARE DELIVERABLES THAT REMAIN AT ALL TIMES PROPERTY OF STACK ROCK GROUP, INC. REPRODUCTION OR REUSE OF THIS PRODUCT CONTAINED HERE IN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF STACK ROCK GROUP, INC. @201 6 STACK ROCK GROUP, INC. STACK ROCK GROUP, ING. LANDSCAPE ARCHITECTURE/ MASTER PLANNING W W W.STACKROGK6ROURGOM FAI Maxey TookeyArchitects, L.L.P. 1412 W. IDAHO ST, SUITE 210 Boise, Idaho 83702 PHONE: (208) 344-9600 http.//wwwmaxey-tookey, com chudgmaxey-tookey. com PRELIMINARY 000III fill,, . `S OF I �• =* v y - d - -1 3 7.2 5.17 NOT FOR CONSTRUCTION O N 00 O 00 a o U m O U' m^0 `0 00 4 O cn U) U O 04 C a O N X z N li -0 0 t N Z3 Un m L 0 O 14- C14 o m N �°41 o c 0000E O ON W o L � N 0 N a- 0 O L 00 m I� i J Q U (n + z 0 m _ QLd OY U w I I U O J I� c a D z z c� LL] a N a: 0 z O } � z m � O z m o' O F7 - a --D w O D U J JOB #: FBC# ??? JOB #1 MTA #1701 ISSUE DATE: 5-15-17 ISSUE: DESIGN REVIEW SHEET: L 1.02 OF SHEETS I I I I I FUTURE CITADEL I I STORAGE SITE I I I I I I I I O I I O W W W W W W W W W W O • - L 2 x un �. 57< ° I 3 I 1 G a c IF ij 4�I DING PLANT SCHEPULF— TREES BOTANICAL NAME / COMMON NAME CONT GAL 2 QTY 0 Gledit5ia triacantho5 inermi5 'Skycole' TM / Skyline Thornle55 Honey Locust 45'W x 35'W B B B 2"Gal 6 8 SHRUBS BOTANICAL NAME / COMMON NAME SIZE FIELD2 9 QTY 10 Gornu55ericea / Red Twig Dogwood 9'H x 5'W 2 gal 55 Prunus laurocerasus 'Otto Luyken' / Luykens Laurel 4'H x 8'W 2 gal 54 REFERENCE NOTE5 SCHEDULE CODE I7E5GRIPTION 1 5TORAGE BUILDING, SEE ARCH 2 STORMWATER DETENTION POND, SEE CIVIL 3 FIRE HYDRANT, TYP, SEE GIVIL 5 DRAINAGE STRUCTURES 8 FACILITIES, 5EE CIVIL 6 ROCK MULCH IN THIS AREA ONLY, OVER FABRIC, NO IRRIGATION ON SHARED SAME USE PERIMETER -7 FENCE, SEE CIVIL 8 EXI5TING TREES, PRESERVE AND PROTEGT, NO WORK WITHIN CRITICAL ROOT ZONE LIMITS 9 RE5EED TO NATIVE HERE 10 REVEGETATE TO NATIVE ONLY AS NEEDED EG E EG "" w1—w W W—I W y�l W W I I I I STACK ROCK GROUP THE GRAPHICS AND DESIGNS ON THIS SHEET ARE DELIVERABLES THAT REMAIN AT ALL TIMES PROPERTY OF STACK ROCK GROUP, INC. REPRODUCTION OR REUSE OF THIS PRODUCT CONTAINED HERE IN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF STACK ROCK GROUP, INC. @201 6 STACK ROCK GROUP, INC. STACK ROCK GROUP, ING. LANDSCAPE ARCHITECTURE/ MASTER PLANNING W W W.STACKROGK6ROURGOM FAI EG- w— Maxey TookeyArchitects, L.L.P. 1412 W. IDAHO ST, SUITE 210 Boise, Idaho 83702 PHONE: (208) 344-9600 http.//wwwmaxey-tookey. com chuck@maxey-tookey. com PRELIMINARY 000III fill,, . `S OF I �• =* v y - d - -1 3 7.2 5.17 NOT FOR CONSTRUCTION O 0 N 0 00 � I Q O m O U' m^00 0 l0 O cn U O C a O -0 N X z N LL. -0 QN Z3 11) o p O 14- C,4 >_ I @ o m N 0 (0 41 o c 0^0 �w N p N a- 0 O 00a_ i J Q U U) + z 0 m _ QLd OY U w I I U O J I� (f) a 0 z z c� LLJa N a: 0 z O} F --z m ILL] O z m O Q a --D w D o D U J JOB #: FBC# ??? JOB #1 MTA #1701 ISSUE DATE: 5-15-17 ISSUE: DESIGN REVIEW SHEET: L 1.02 OF SHEETS