Loading...
L-100_Building A Landscape PlanBUILDING A 3,259 sf BUILDING B 4,663 sf BUILDING C 3,587 sf BUILDING D 5,201 sf S. W O O D S A G E A V E . W. OVERLAND RD. S 89°07'22" E 280.41' N 89°00'00" W 301.86' N 0 1 ° 0 0 ' 0 0 " E 25 6 . 6 1 ' S 0 0 ° 4 1 ' 2 8 " W 27 7 . 4 3 ' N 45°37'56" E 28.41' LANDSCAPE LEGEND MULCH GROUND COVER IN PLANTING AREA Mixed bulbs & perennials PINUS FLEXILIS 'VANDERWOLF'S PYRAMID' QTY: 18 HEIGHT: 20 -30' SPREAD: 10 -15' NEW 3 QT. QTY: 88 HOSTA PLANTAGINEA 'APHRODITE PLANTAIN LILY' LANDSCAPE NOTES 1. THE TOP 3" OF SOIL (1" MINUS) IN PLANTING BEDS/NON -TURF AREAS SHALL BE COVERED W/SMALL BARK CHIPS AFTER PLANTING. 2. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED I F NOT IN A SOUND AND HEALTHY CONDITION. 3. OTHER VARIETIES WITH SIMILAR GROWTH HABIT AND EXACT CONDITIONS REQUIREMENTS MAY BE USED. 4. MIXED BULBS -PROVIDE MIXED COLOR EARLY SINGLE FLOWERING EMPEROR AND GREIGIL AND MID -SPRING FLOWERING DARWIN HYBRID. TOP SIZE 12 CM. PLANT IN FALL 4" DEEP, 8" o.c. 5. MULCH SHALL BE PLACED A MINIMUM OF 2" AWAY FROM ANY PLANT TRUNK OR STEM. 6. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, I.E. . . .FROM BEING BLOWN OVER, PLANTED W/LOOSE ROOT BALL, ETC. 7. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY OWNER -REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY W/THE SAME SIZE & SPECIES AT NO COST TO THE OWNER. 8. ALL EXISTING TREES, PLANTS, SOD, AND ROCK OUTCROPPINGS IN SETBACK AREAS TO REMAIN OR TO BE RELOCATED OR REPLACED AS NEEDE D. 9. RE -USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETING REQUIREMENTS AND AMEND WHERE NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCK S, GRASS OR OTHER FOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON -SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A) PROVIDE APPROVED IMPORTED TOPSOIL, OR B) IMPROVE ON -SITE WITH METHODS APPROVED BY ARCHITECT. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS, SODS, STONES, CLAY LUMPS, AND OTHER EXTRANEOUS MATERIALS H ARMFUL TO PLANT GROWTH. IMPORTED TOPSOIL SHALL BE OBTAINED FROM A LOCAL SOURCE OR AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FO UND ON PROJECT SITE. REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, AND GENERAL TEXTURE BY A RECOGNIZED GOVERNMENT AGENCY. 10. IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6" INCHES OF TOPSOIL WILL BE AMENDED AT A RATIO OF 3 CUBIC YARDS OF COMPOST/O RGANIC MATTER PER 1000 SQUARE FEET. ROTO -TILL ORGANIC MATTER A MINIMUM OF 6" INTO TOPSOIL. ALL TREE PITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL AND 3 PARTS COMPOST/ORGANIC MATTER, BY VOLUME. 11. ALL PLANTING BEDS SHALL HAVE A MINIMUM OF OF 18" TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3" BELOW SURFACE OF WALKS AND CURBS IN PLANTING BED AREAS, AND 1/2" IN LAWN AREAS. 12. FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. 13. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY O FF SITE. 14. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY Z ONED FOR REQUIRED WATER USES. 15. EACH HYDRO -ZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. 16. POP -UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 18" AT PLANTER BEDS, 4" AT LAWN AREAS. 17. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS OR POP -UP SPRAY SYSTEMS. ANNUALS, PERENNIALS, GROUND COVERS, OR SHRUB MASSINGS SHALL HAVE A POP -UP SPRAY SYSTEM. 18. ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: -PRECISE INDIVIDUAL STATION TIMING -RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES -AT LEAST ONE PROGRAM FOR EACH HYDROZONE -SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN -OFF 19. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVI DUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WA TER TO RESPECTIVE HYDRO -ZONES. 20. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO -ZONES. 21. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPR OPRIATE. 22. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS SIDEWALKS, DRIVEWAYS, AND PARKING AREA. 23. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLY AS PER CITY OF MERIDIAN STANDARDS (SEE DETAIL THIS PAGE), KEEPING FREE OF ROCKS AND/OR OTHER DEBRIS DURING INSTALLATION. NEW 1 GAL QTY: 32 BUXUS 'GREEN VELVET BOXWOOD' NEW 1 GAL QTY: 55 SALVIA MALUS 'SPRING SNOW CRABAPPLE' QTY: 21 HEIGHT: 20 -25' SPREAD: 15 -20' NEW 1 GAL QTY: 49 FESTUCA GLAUCA 'ELIJAH BLUE' NEW 1 GAL QTY: 26 EUONYMUS FORTUNEI 'EMERALD AND GOLD' NEW 1 GAL QTY: 50 CORTADERIA SELLOANA 'PAMPAS GRASS' GRASS CL I E N T : JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY N O T F O R P E R MI T 17110 Sa g e w o o d C o m m e r c i a l S h e l l Bu i l d i n g A 10 5 5 O v e r l a n d R D M e r i d i a n , A d a , I D 8 3 6 4 2 L-100 Pr i d e , L L C . LANDSCAPE PLAN JDB NO. DESCRIPTION DATE A CZC/DR 6/30/17 1" = 20'-0" 1 LANDSCAPE PLAN 1/2" = 1'-0" 3 PLANTER EDGE CUT DETAIL 1/2" = 1'-0" 4 SHRUB PLANTING DETAIL 1/2" = 1'-0" 2 TREE PLANTING DETAIL