PZ - Staff Report - REV 10/18Paramount Director MDA, PP, RZ H-2016-0104 PAGE 1
STAFF REPORT
HEARING DATE: October 20, 2016
(Continued from: October 6, 2016)
TO: Planning & Zoning Commission
FROM: Sonya Allen, Associate City Planner
208-884-5533
Bruce Freckleton, Development Services Manager
208-887-2211
SUBJECT: Paramount Director – MDA, PP, RZ (H-2016-0104)
I. SUMMARY DESCRIPTION OF APPLICANT’S REQUEST
The applicant, Brighton Investments/Land Holdings, has submitted the following applications:
A modification to the existing development agreement (MDA) to amend certain provisions and
include a conceptual development plan for the site;
A rezone (RZ) of 37.31 acres of land from the C-C and TN-C zoning districts to the R-15 zoning
district; and
A preliminary plat consisting of 196 building lots, 12 common area lots and 2 future right-of-way
lots on 35.63 acres of land in the R-15 zoning district.
See Section VIII, Analysis, for more information.
II. SUMMARY RECOMMENDATION
Staff recommends approval of the proposed MDA, RZ and PP applications with the conditions of
approval in Exhibit B, based on the Findings of Fact and Conclusions of Law in Exhibit D of the Staff
Report.
III. PROPOSED MOTION
Approval
After considering all staff, applicant and public testimony, I move to recommend approval of File
Number H-2016-0104 as presented in the staff report for the hearing date of October 20, 2016, with
the following modifications: (Add any proposed modifications.)
Denial
After considering all staff, applicant and public testimony, I move to recommend denial of File
Number H-2016-0104, as presented during the hearing on October 20, 2016, for the following
reasons: (You should state specific reasons for denial.)
Continuance
I move to continue File Number H-2016-0104 to the hearing date of (insert continued hearing date
here) for the following reason(s): (You should state specific reason(s) for continuance.)
IV. APPLICATION AND PROPERTY FACTS
A. Site Address/Location:
The subject property is located at the southwest corner of W. Chinden Blvd. and N. Meridian
Road, in the northeast ¼ of Section 25, Township 4 North, Range 1 West.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 2
B. Applicant:
Brighton Investments/Land Holdings
12601 W. Explorer Drive, Suite 200
Boise, ID 83713
C. Owner:
Same as applicant
D. Representative:
Michael D. Wardle, Brighton Corporation
12601 W. Explorer Drive, Suite 200
Boise, ID 83713
E. Applicant's Statement/Justification: Please see applicant’s narrative for this information.
V. PROCESS FACTS
A. The subject application is for a development agreement modification which requires a public
hearing before the City Council; and a rezone and preliminary plat which require a public hearing
before the Planning & Zoning Commission and City Council, consistent with Meridian City Code
Title 11, Chapter 5.
B. Newspaper notifications published on: September 19 and October 3, 2016
C. Radius notices mailed to properties within 300 feet on: September 8, 2016
D. Applicant posted notice on site by: October 10, 2016
VI. LAND USE
A. Existing Land Use(s) & Zoning: This site consists of vacant/undeveloped land, zoned C-C and
TN-C.
B. Character of Surrounding Area and Adjacent Land Use and Zoning:
North: W. Chinden Blvd., agricultural and commercial land, zoned MU-DA in Ada County
South: W. Director Street and single-family residential properties, zoned R-8
East: N. Meridian Road and a church, zoned RUT in Ada County
West: N. Fox Run Way and single-family residential properties, zoned R-8; and an assisted living
facility, zoned C-C
C. History of Previous Actions:
In 2013, the subject property was annexed (AZ-13-005, Paramount Northeast).
A Development Agreement (DA) modification application (H-2015-0022) was approved in
2015 to include the annexation area in the existing DA (Inst. No. 1031317116, amended as Inst.
No. 113083665) for Paramount Subdivision, recorded as Instrument No. 2016-005060.
In January 2016, a preliminary plat (Paramount North Forty, H-2016-0034) was approved for
the subject property. A final plat was never submitted.
D. Utilities:
Location of sewer: Sanitary sewer mains intended to serve the eastern portion of the subject site
currently exist directly adjacent to the subject parcel in W. Director Street,
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 3
and a main intended to provide service to the western portion of the subject
site is currently under construction as part of the Paramount Veranda Assisted
Living project.
Location of water: Water mains intended to serve the eastern portion of the subject site currently
exist directly adjacent to the subject parcel in W. Director Street, and a main
intended to provide service to the western portion of the subject site is
currently under construction as part of the Paramount Veranda Assisted
Living project.
Issues or concerns: None.
E. Physical Features:
1. Canals/Ditches Irrigation: The North Slough crosses the southwest corner of this site.
2. Hazards: Staff is unaware of any hazards that may exist on this site.
3. Flood Plain: This property does not lie within the floodplain or flood way.
VII. COMPREHENSIVE PLAN ANALYSIS
Land Use: Approximately 26 acres of the site is designated Mixed Use - Community (MU-C) and
approximately 15 acres is designated Medium Density Residential (MDR) on the Future Land Use
Map (FLUM) contained in the Comprehensive Plan.
The purpose of the MU-C designation is to allocate areas where community-service uses and
dwellings are seamlessly integrated into the urban fabric. The intent of the MU-C designation is to
integrate a variety of uses, including residential, and to avoid mainly single-use and strip commercial
type buildings. Development should comply with the general guidelines for development in all mixed
use areas and have a mix of at least 3 land use types. Residential uses should comprise a minimum of
20% of the development area at densities ranging from 6 to 15 units/acre. See pages 27-28 in the
Comprehensive Plan for more information.
The intent of the MDR designation is to allow smaller lots for residential purposes within City limits.
Uses may include single-family homes at gross densities of 3 to 8 units/acre.
The applicant proposes to develop the site with single-family attached homes consisting of a total of
196 units at a gross density of 5.5 dwelling units per acre and a net density of 9.92 units per acre.
Single-family attached homes (2 attached units on individual properties) are listed as an appropriate
use in the MDR designation but are not specifically listed as an appropriate use in the MU-C
designation; townhomes (3 or more attached units on individual properties) are listed as an
appropriate use. Because single-family attached and townhome units are both located on individual
lots, the proposed density and zoning (R-15) is consistent with both FLUM designations for this site,
and age qualified 55+ housing is proposed for variety in half of the development, staff feels the
proposed use is appropriate.
This site is located at the corner of a major arterial intersection (W. Chinden Blvd./N. Meridian Rd.).
A residential care facility is currently under construction at the west boundary of this site at the
southeast corner of Chinden & Fox Run; and a church, private school, and Zamzow’s retail store exist
to the east across Meridian Road. The proposed development will contribute to the variety of
residential housing options and mix of uses in this area.
The following items from the Comprehensive Plan are considered when reviewing development
applications in Mixed Use areas: (Staff’s analysis in italics)
“Residential densities should be a minimum of 6 dwelling units/acre.” (pg. 23)
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 4
The proposed gross density of the development is 5.5 dwelling units/acre gross and 9.92
dwelling units per acre net, consistent with that desired in MU-C and MDR designated areas.
“Where feasible, higher density and/or multi-family residential development will be
encouraged, especially for projects with the potential to serve as employment, destination
centers and when the project is adjacent to US 20/26, SH-55, SH-16 or SH-69.” (pg. 23)
The proposed project provides for higher density residential development adjacent to US
20/26 (Chinden Blvd.) and contributes to the variety of housing options in this area. This
area is predominately developed with single family detached residential homes; a residential
care facility is currently under construction to the west. Staff believes the prosed attached
units will provide additional housing options at a higher density near employment and
mobility corridors.
“A mixed use project should include at least 3 types of land uses; exceptions may be granted
for smaller sites on a case by case basis.” (pg. 24)
The larger mixed use area consists of a variety of uses including single-family detached
homes, a residential care facility, a church, a private school and a retail store (Zamzow’s).
There is also quite a bit of land to the west within the MU-C designated area that is yet to
develop which will further contribute to the variety of uses in this area.
“Support a variety of residential categories (low-, medium-, medium-high and high-density
single-family, multi-family, townhouses, duplexes, apartments, condominiums, etc.) for the
purpose of providing the City with a range of affordable housing opportunities.” (3.07.01E)
Although staff is unaware of how “affordable” the proposed units will be, the medium density
development will contribute to the variety of lot sizes, prices and types of housing in this
area.
“Provide for a wide diversity of housing types (single-family, modular, mobile homes and
multi-family arrangements) and choices between ownership and rental dwelling units for all
income groups in a variety of locations suitable for residential development.” (3.07.03B, pg.
56)
The proposed attached units will contribute to the diversity in housing types as well as
provide for age qualified (55+) housing in this area; however, staff is unaware if the units
will be owner occupied or rentals.
“Permit new development only where urban services can be reasonably provided at the time
of final approval and development is contiguous to the City.” (3.01.01F, pg. 45)
City services are available to be extended to this development.
“Restrict private curb cuts and access points on collectors and arterial streets.” (3.06.02D)
There are no direct access points for this site proposed via Chinden Blvd., a state highway, or
N. Meridian Road, an arterial street. An access via N. Fox Run Way, a collector street, was
previously approved for this property; two other accesses are proposed via W. Director
Street, a collector street. Access via a local street is not available. Because two accesses are
required for emergency purposes, one of the accesses via Director is allowed; the other
requires Council approval of a waiver to UDC 11-3A-3.
“Ensure development provides safe routes and access to schools, parks and other community
gathering places.” (3.07.02N)
A detached 10-foot wide multi-use pathway is required along W. Chinden Blvd. and N.
Meridian Road and exists along W. Director Street which will provide a safe route to the
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 5
church and private school to the east and the internal amenities and the public schools to the
west as well as other community gathering places in the vicinity.
VIII. ANALYSIS
A. Analysis of Facts Leading to Staff Recommendation:
1. DEVELOPMENT AGREEMENT MODIFICATION (MDA): A modification to the existing
development agreement (DA) (Instrument No. 2015-005060) is requested to amend certain
provisions and include a conceptual development plan for the site (see Exhibits A.6 and A.7).
The existing DA requires the agreement to be modified to include a conceptual development plan
for the subject property. The concept plan is required to show access and circulation, a mix of at
least 3 land use types, and residential densities ranging from 6 to 15 units per acre in the MU-C
designated area and 3 to 8 units per acre in the MDR designated area per the Comprehensive
Plan.
The applicant proposes to amend the DA as follows: (The Applicant’s requested changes are in
underline/strike-out format; Staff’s proposed changes are in double underline/strike-out format;
and Staff’s comments in regard to the proposed changes are in italics below.)
#6.3 – “A detached10-foot wide multi-use pathway shall be provided within the street buffers
along W. Chinden Boulevard, along the west side of N. Meridian Road, and along the north
side of W. Director Street within a public use easement in accord with UDC 11-3H-4C.4. The
public use easement shall be submitted to the City, approved by City Council and recorded
prior to issuance of any Certificate of Zoning Compliance or, approval of any subsequent
land use application for the C-C and TN-C zoned properties the City Engineer signing the
final plat.”
The proposed changes are consistent with that approved with the preliminary plat for
Paramount North Forty – Staff is in agreement with the proposed change.
#6.4 – “Right-of-way (ROW) shall be dedicated reserved in the amount required by the Idaho
Transportation Department for the expansion of W. Chinden Boulevard with development of
the C-C and TN-C zoned properties adjacent to Chinden Boulevard.”
The term “dedicated” implies donation of ROW to ITD; the proposed change reserves the
area which is the intent. Zoning designations are not necessary to include and is proposed to
change. Staff is in agreement with the proposed changes.
#6.8 – “A modification of the development agreement is required to include a conceptual
development plan for the TN-C and C-C zoned property located at the southwest corner of
W. Chinden Blvd. and N. Meridian Road and at the southwest corner of W. Chinden Blvd.
and N. Fox Run Way prior to submittal of a Certificate of Zoning Compliance application (if
required) or issuance of any building permits.”
The concept plan(s) should include a site plan showing access and circulation; and a mix of at
least 3 land use types; and residential densities ranging from 6 to 15 units/acre in the MU-C
designated area and 3 to 8 units/acre in the MDR designated area as required in the
Comprehensive Plan (pgs. 27-28 and pg. 20 respectively).
Zoning designations are not necessary to include and are proposed to change. A mix of uses
is required for the overall MU-C designated area, not just this site. The existing and
proposed uses in the overall MU-C area meet this requirement. Staff is in agreement with the
proposed changes.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 6
In addition to the Applicant’s proposed changes, Staff recommends the following change:
#6.2 – A minimum 35-foot wide street buffer is required along W. Chinden Boulevard, an
entryway corridor, on the C-C and TN-C zoned properties and shall be landscaped in accord
with the standards listed in UDC 11-3B-7C.
The zoning districts aren’t necessary to include and are proposed to change with this
application.
The proposed conceptual development plan depicts a 196-unit single-family attached housing
development with two types of products for variety – single-story units for age qualified 55+ on
the west side of the development adjacent to the residential care facility; and 2-story units with 3
bedrooms (+ another bedroom/bonus room) on the east end of the development – all with
common driveways and side entry garages.
Public streets are proposed for internal circulation throughout the development with landscaped
chokers for traffic calming and aesthetic appeal. The proposed use contributes to the mix of uses
and housing options in this area as required in MU-C designated areas. Therefore, staff is in
general support of the proposed concept plan.
2. REZONE (RZ): A rezone of 37.31 acres of land from the C-C and TN-C zoning districts to
the R-15 zoning district for the development of 196 single-family residential attached units is
proposed consistent with the associated MU-C and MDR FLUM designations for this site.
The legal description submitted with the application, included in Exhibit C, shows the boundaries
of the property proposed to be rezoned.
The City may require a development agreement (DA) in conjunction with a rezone pursuant to
Idaho Code section 67-6511A. Because an amendment to the existing DA is proposed with this
application that will update the agreement in accord with the proposed plan, staff does not
recommend a new DA is required for this site.
PRELIMINARY PLAT (PP): A preliminary plat is proposed that consists of 196 building lots, 12
common area lots and 2 future right-of-way lots on 35.63 acres of land in the proposed R-15
zoning district.
Two different types of single-family attached structures are proposed within this development.
The Encore units are an age qualified 55+ single-story, attached product configured in quads with
shared driveways and side-entry garages located at the west end of the development consisting of
98 units. The Cadence units are a 2-story, attached product with side-entry garages accessed from
shared driveways located at the east end of the development consisting of 98 units (see Exhibit
A.4).
Dimensional Standards: The lots in the proposed subdivision are required to comply with the
dimensional standards of the R-15 zoning district listed in UDC Table 11-2A-7 and the block
length standards listed in 11-6C-3F. Staff has reviewed the proposed plat and found it in
compliance with these standards.
Building setbacks are required to comply with the setbacks noted in UDC Table 11-2A-7 for the
R-15 district. Based on the common driveway exhibit in Exhibit A.5 for the Encore units, the
rear building setback needs to be extended from 3 feet to a minimum of 12 feet. The
applicant states that the lots can be lengthened into the adjacent common area to accommodate
this requirement on the affected lots.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 7
Access: One access is proposed via N. Fox Run Way, a collector street, which was previously
approved with the development agreement and preliminary plat for Paramount North Forty and is
shared with the residential care facility. Two accesses are proposed via W. Director Street, a
collector street; one of those is required for emergency access. The other access via Director
requires Council approval of a waiver to UDC 11-3A-3 for access. No access is proposed or
allowed via W. Chinden Blvd. and N. Meridian Road.
The Idaho Transportation Department (ITD) is the transportation authority for US-20/26/W.
Chinden Blvd. abutting this development on the north. The Ada County Highway District
(ACHD) is the transportation authority for all other public streets within and abutting this
development. ITD and ACHD’s comments on this application are included in Exhibit B, Sections
7 and 8.
A 30-foot wide common lot is proposed along Chinden and a 40-foot wide common lot is
proposed along Meridian for future right-of-way for the expansion of these streets.
Landscaping: A 35-foot wide street buffer is required along US-20/26/W. Chinden Blvd., a state
highway/arterial street and along N. Meridian Road, an arterial street (both entryway corridors);
and a 20-foot wide street buffer is required along N. Fox Run Way, a collector Street.
Landscaping is required within the street buffers in accord with the standards listed in UDC 11-
3B-7C. The plat depicts a 75-foot wide buffer along Chinden Blvd. and a 40-foot wide buffer
along Meridian Rd.
The common lots proposed along Chinden Blvd. and Meridian Road for future right-of-way for
the expansion of these streets is required to be landscaped in the interim with vegetative
groundcover in accord with UDC 11-3B-7C.5.
Parkways: Six-foot wide parkways are proposed in bulb-outs and within common areas adjacent
to streets. Because the parkways are only proposed to be 6-feet wide, root barriers are
required. All parkways shall be constructed in accord with the standards listed in UDC 11 -3A-
17.
Common Open Space & Site Amenities: Based on the size of the proposed development, a
minimum of 10% (or 3.6 acres) of qualified open space is required as set forth in UDC 11-3G-3B;
and a minimum of one qualified site amenity is required as set forth in UDC 11-3G-3C.
A total of 8.63 acres (or 24.2%) of qualified open space is proposed consisting of half of the 35-
foot wide street buffers required along W. Chinden Blvd. and N. Meridian Road, both arterial
streets, plus additional area outside of the required buffer that’s part of those lots; all of the street
buffer and common area along N. Fox Run Way and W. Director Street (within the boundary of
the proposed plat), both collector streets; and common areas where amenities for the development
are proposed.
Proposed site amenities consist of a swimming pool and clubhouse in the Encore portion of the
development; a swimming pool with a restroom facility, tot lot and associated parking area in the
Cadence portion of the development; and segments of the City’s multi-use pathway system along
W. Chinden Blvd. and N. Meridian Rd., in compliance with UDC standards. A Certificate of
Zoning Compliance and Design Review application is required to be submitted and approved for
the swimming pools, clubhouse, restroom facility and parking lot.
Pathways: A 10-foot wide multi-use pathway is required to be provided per the Pathways Master
Plan along W. Chinden Blvd. and N. Meridian Road as proposed. A 10-foot wide pathway also
exists off-site along W. Director Street adjacent to the south boundary of the site.
Staff recommends a north/south pathway is provided within Lot 23, Block 5 between Lots
31 and 32; and within Lot 12, Block 4 between Lots 23 & 24 and 1 and 35 to connect to the
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 8
east/west pathways; and within Lot 6, Block 3. The addition of the pathways will allow the
area to be counted toward the qualified open space requirement because it’s below 50’ x 100’ in
area.
Sidewalks: The UDC (11-3A-17) requires 5-foot wide detached sidewalks to be constructed
along collector streets; and 5-foot wide attached sidewalks to be constructed along local streets. A
4-foot wide detached sidewalk exists along N. Fox Run Way, a collector street; because it’s a
fairly new sidewalk, staff does not recommend it’s reconstructed as a 5-foot sidewalk if 5’ x 5’
turnouts are constructed every 200 feet to comply with ADA standards, otherwise the
sidewalk should be reconstructed as a 5-foot wide sidewalk. Five-foot wide attached sidewalks
are proposed internally along local streets.
Common Driveways: Common/shared driveways are proposed throughout the development for
access to each unit and are required to be constructed in accord with the standards listed in UDC
11-6C-3D. The plat should be revised to include a common lot or easement on the building
lots for each of the common driveways.
The UDC (11-6C-3E.7) requires any plats using a common driveway to depict the setbacks,
building envelope, and orientation of the lots and structure that are accessed via a common
driveway on the preliminary plat and/or as an exhibit with the final plat application. The
applicant has submitted exhibits for the both the Encore and Cadence portions of the
development that depict the aforementioned items; however, the rear setback on the Encore
units is depicted at 3 feet and should be a minimum of12 feet per UDC Table 11-2A-7. The
applicant states the rear lot line can be adjusted into the adjacent common areas on the affected
lots to comply with this standard.
A perpetual ingress/egress easement is required to be filed with the Ada County Recorder, which
shall include a requirement for maintenance of a paved surface capable of supporting fire vehicles
and equipment, for the common driveways.
Parking: Off-street parking is required as set forth in UDC Table 11-3C-6 for single-family
attached units. For 2, 3 and 4 bedroom units, a minimum of 4 vehicle spaces are required per unit,
at least 2 in an enclosed garage, the 2 other spaces may be enclosed or a minimum 10’ x 20’
parking pad each.
The Encore units contain 2 bedrooms (+ 1 bedroom/den) and comply with this standard. The
Cadence units contain 3 bedrooms (+ 1 bedroom/bonus room) and have 2-car garages but
the shared driveway configuration does not allow for the 2 additional parking pads
required for each unit. As designed, the Cadence portion only provides half of the required
number for a total of 196 spaces fewer than required.
The applicant requests a waiver to this requirement; however, there is no mechanism in the UDC
for a waiver. The UDC (Table 11-5B-5) does allow for alternative compliance to UDC 11-3C-6
as set forth in UDC 11-5B-5; alternative compliance is a staff-level Director-approved
application. The applicant should either reconfigure the plat to comply with this standard,
which will result in a reduction in the number of building lots; or, submit an application
(and gain approval) for alternative compliance with the final plat application for the
affected lots. If alternative compliance is not approved, the plat will need to be revised to
accommodate the required off-street parking; or, the product type will need to be changed
to accommodate the required off-street parking.
Note: According to staff’s calculations, approximately 155+/- on-street parking spaces can be
accommodated consisting of 1+ space(s) in front of each unit and at the ends of blocks where
non-street fronting units are located; and 43 off-street parking spaces are proposed adjacent to
the community pool. In order for alternative compliance to be approved, the Director has to
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 9
determine three findings as listed in UDC 11-5B-5E, one of which is the alternative compliance
provides an equal or superior means for meeting the requirements.
Fencing: Fencing is not depicted on the proposed landscape plan but a detail of the berm and
sidewalk proposed along W. Chinden Blvd. and N. Meridian Road, which also depicts a
fence/wall, is included on Sheet PP4.2 (see Exhibit C).
The developer is responsible for constructing fences abutting pathways and common open
space lots to distinguish common from private areas; fencing details should be included
with the final plat application in accord with the standards listed in UDC 11-3A-7A.7.
All fencing should comply with the standards listed in UDC 11-3A-7 and 11-3H-4D.
Noise Abatement: Noise abatement is required for residential uses adjoining state highways (i.e.
US-20/26 aka Chinden Blvd.) as set forth in UDC 11-3H-4D. The applicant has submitted a
cross-section of the berm and pathway proposed along Chinden Blvd. and Meridian Road that
also includes a fence/wall (see Sheet PP4.2 of the landscape plan in Exhibit A.3.). A detail of the
fence/wall should be submitted with the final plat application that complies with this
standard.
Waterways: The North Slough has been relocated and is located within a 40-foot wide easement
along the west boundary of this site and has been tiled.
Utilities: All development is required to connect to the City water and sewer system unless
otherwise approved by the City Engineer in accord with UDC 11-3A-21.
Street lighting is required to be installed within the development in accord with the City’s
adopted standards, specifications and ordinances.
Pressurized Irrigation (PI): An underground PI system is proposed to be provided to each lot in
the subdivision in accord with UDC 11-3A-15. The system will be operated and maintained by
the Homeowner’s Association.
Storm Drainage: A storm drainage system is required for the development in accord with the
City’s adopted standards, specifications and ordinances. Design and construction shall follow best
management practice as adopted by the City in accord with UDC 11-3A-18. Stormwater is
proposed to be retained in an onsite detention area in accord with ACHD requirements.
Building Elevations: Conceptual building elevations were submitted for each of the 2 types of
attached units (Cadence & Encore) as shown in Exhibit A.4. Building materials consist of 2
different types of materials with stone veneer accents. The applicant states there are 2 different
Encore floor plans – front units (Plan 1) and rear units (Plan 2) with elevation variations; and 1
floor plan for the Cadence units with a few differences between the back-to-back units (Plans 1
and 2), primarily on the first floor.
All attached structures are required to comply with the residential design standards listed
in the Architectural Standards Manual. An administrative design review application must
be submitted to the Planning Division and approved prior to submittal of building permit
applications; one design review application can be submitted for the overall development.
Staff recommends approval of the proposed MDA, RZ and PP applications with the conditions
included in Exhibit B.
IX. EXHIBITS
A. Drawings/Other
1. Vicinity/Zoning Map
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 10
2. Proposed Preliminary Plat (dated: 10/12/16, Revised)
3. Proposed Landscape Plan (dated: 8/16/16)
4. Proposed Conceptual Building Elevations & Site Layout
5. Common Driveway Exhibits (NOT APPROVED)
6. Proposed Modifications to Development Agreement (Instrument No. 2015-005060)
7. Proposed Conceptual Development Plan to be Included in Development Agreement
B. Agency & Department Comments/Conditions
C. Legal Description and Exhibit Map for Rezone
D. Required Findings from Unified Development Code
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 11
Exhibit A.1: Vicinity/Zoning Map
ÚÚd
C-N
L-O
RUT
L-O
RUT
R-8
R-15
C-C
L-O
R-8
C-CC-G
R-8
R-2
R1
C-C
RUT
C-C
RUT
TN-C
R-4
RUT
R-4
RUT
R-4
RUT
R-8
C-C
N
L
i
n
d
e
r
R
d
E Chinden Blvd
W CayuseCreek Dr
W Chinden Blvd
N
M
e
r
i
d
i
a
n
R
d
N
L
a
n
d
o
n
C
r
e
e
k
P
l
W
C
r
o
s
b
y
D
r
E Segundo St
ESanPedro St
WRattlesnakeDr
W D i r e c t o r S t
W Pr
o
d
u
c
e
r
D
r
N
M o r p h e u s
A v e
W Woodward S t
N
Isla
A
v
e
E Boulder Bar St
E Tallinn St
N
R e d
H i l l s
A v e
E Everest St
N
B e r g m a n
A v e
W Heston Dr N
S a g u a r o
H i l l s
A v e
N
R o s a
S p r i n g s
A v e
N
G
a
r
b
o
Av
e
E Rio C o l i n a s D r
W
BacallDr
W H e s t o n
C t
N
S e n i t a
H i l l s
A v e
N K
e
a
t
o
n
W
a
y
E SanPedroSt
W Bro
d
e
r
i
c
k
D
r
N
Moose
Creek
Ave
E
P
r
o
d
u
c
e
r
D
r
E Tuttle St
N
G
a
r
b
o
Av
e
N M i t c h u m W a y
E Cholla Hills St
E Joshua Tree Dr
W
G
a
b
l
e
S
t
E San Pedro St
W PuzzleCreek Ct
E Segundo St
E Giant Saguaro St
NGertie
Pl
N
B o o t h
A v e
W Glade Creek St
N
R
e
d
H
i
l
l
s
P
l
W Cedar Grove St
WEagleMountainDr
WMartenCreekDr
E I r o n s t o n e Ct
N
Moose
Creek
Ave
N
F
o
x
R
u
n
W
a
y
N D i e t r i c h A v e
N
S a g u a r o
H i l l s
A v e
N
R
e
d
H
o
r
s
e
W
a
y
WHamRapidsSt
W C a y u s e C r e e k D r
E Pasacana St
E Martello Ln
E Klamath Ln
N
B r y n n e r
A v e
W
C
a
g
n
e
y
S
t
E Almos St
W Everest
Ln
N
M
o
r
p
h
e
u
s
P
l
W Coburn St
E I r o n s t o n e D r
W Caine St
E Azan S t
N
P e p p a r d
A v eW
D
r
e
y
f
u
s
s
S
t
N
P i n e r y
C a n y o n
A v e
E C h olla Hills St
E Martello Ln
E Lockhart Ln
WRootCreekSt
N
K e a t o n
A v e
W Bacall St
E Cholla Hills St
N
M i t c h u m
A v e
N
R o s a
S p r i n g s
A v e
N
S e n i t a
H i l l s
A v e
N
B e a h a m
A v e
N
L a r k w o o d
P l
N
P e p p a r d
A v e
N
S
a
g
u
a
r
o
H
i
l
l
s
P
l
E Pasacana St
WBrandtLn
W Barrymore D r
W V a l e n tino Dr
N
E
l
k
R
a
n
c
h
L
n
W
C
o
l
b
e
r
t
S
t
W
P
i
c
k
f
o
r
d
S
t
W
V
a
l
e
n
t
i
n
o
S
t
W Hitchcock St
WIslandGreenDr
N
H o o d
A v e
N
R
i
o
V
i
s
t
a
W
a
y
N
D i a m o n d
C r e e k
A v e
N
A
r
l
i
s
s
A
v
e
N
R e d
H i l l s
A v e
N
L a n g e
A v e
N
C
l
a
r
e
t
C
u
p
W
a
y
N
M a x i m u s
P l
N
D e m i l l e
A v e
N
R e d
H i l l s
A v e
N
B
a
r
n
e
y
L
n
N
M
a
x
i
m
u
s
W
a
y
N
R o s a
S p r i n g s
A v e
W
Redgrave D r N
B e a h a m
A v e
N
C
h
a
n
n
i
n
g
W
a
y
N R i o L o
m a
s
A v e
W
C
a
g
n
e
y
D
r
SAINT
IGNATIUS
SCHOOL
PARAMOUNT
SUB NO 16
PARAMOUNT
SUB NO 27
PARAMOUNT
SUB NO 05LOCHSA
FALLS
NO 11
PARAMOUNT
SUB
NO 07
LOCHSA
FALLS
NO 06
SAGUARO
CANYON NO 03
ARCADIA
LOCHSA
FALLS NO 01
PARAMOUNT
SUB NO 04
KNIGHT
SKY
ESTATES
KNIGHTHILL
SUBDIVISION
HIGHTOWER
SAGUARO
SPRINGS/MADELYNN
ESTATES
VENTANA NO 02
CARDIGAN
BAY
PARAMOUNT
SUB NO 12
VENTANA NO 01
SAGUARO
CANYON
NO 02
LOCHSA
FALLS NO 03
LOCHSA
FALLS
NO 07
PARAMOUNT
SUB
NO 02
PARAMOUNT
SUB NO 01
PARAMOUNT
SUB NO 08
PARAMOUNT
SUB NO 03
LOCHSA
FALLS
NO 12
LOCHSA
FALLS
NO 02PARAMOUNT
VILLAGE
CENTER
PARAMOUNT
SUB NO 09
SAGUARO
CANYON NO 04
PARAMOUNT
SUB
NO 11
SCHOOL
PARAMOUNT
ELEM
PARAMOUNT
SUB
NO 06
SCHOOL ROCKY
MOUNTAIN HIGH
MOULTON
BRADFORD
PARAMOUNT SUB NO 13
JERICHO
SUBDIVISION
PARAMOUNT
SUB NO 15
SCHOOL
CHALLENGER
PARAMOUNT
SUB NO 17
VILLAS AT
LOCHSA
FALLS
PARAMOUNT
SUB
NO 18
PARAMOUNT
SUB NO 22
PARAMOUNT
SUB NO 21
PARAMOUNT
SUB
NO 19
HACIENDA
SUBDIVISION
NO. 3
HACIENDA
SUBDIVISION NO.2
HACIENDA
HACIENDA NO.5
SPURWING
CHALLENGE
LINDER
& CHINDEN
PARAMOUNT
SUB
NO 24
PARAMOUNT
ADDITIONAL
PHASES
BULL RANCHBIRKDALE
ESTATES
PARAMOUNT NORTHEAST
ASSISTED LIVING
Paramount
No. 29
PARAMOUNT DIRECTOR
EXTENSION
HACIENDA
SOUTH
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 12
Exhibit A.2: Proposed Preliminary Plat (dated: 10/12/16, Revised)
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 13
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 14
Exhibit A.3: Proposed Landscape Plan (dated: 8/16/16)
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 15
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 16
Exhibit A.4: Proposed Conceptual Building Elevations & Site Layout
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 17
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 18
Exhibit A.5: Common Driveway Exhibits (NOT APPROVED)
Rear setback doesn’t comply
with minimum 12’ setback –
revision required
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 19
Parking pad does not
comply with UDC
standards - Revisions
or Alternative
Compliance required
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 20
Exhibit A.6: Proposed Modifications to Development Agreement (Instrument No. 2015-005060) as
Recommended by Staff
Note: Applicant’s proposed changes are in strike-out/underline format; Staff’s recommended changes are in
double strike-out/underline format)
SECTION 6: CONDITIONS GOVERNING DEVELOPMENT OF PROPERTY:
Owner/Developer shall develop the property in accordance with the original Development Agreement
(Instrument #1031317116) and the Addendum to Development Agreement (Instrument # 113083665). In
addition, the following provisions shall also be required:
1. Direct access to W. Chinden Boulevard and N. Meridian Road is prohibited in accord with UDC 11-
3A-3 and 11-3H-4B.
2. A minimum 35-foot wide street buffer is required along W. Chinden Boulevard, an entryway
corridor, on the C-C and TN-C zoned properties and shall be landscaped in accord with the standards
listed in UDC 11-3B-7C.
3. A detached10-foot wide multi-use pathway shall be provided within the street buffers along W.
Chinden Boulevard, along the west side of N. Meridian Road, and along the north side of W. Director
Street within a public use easement in accord with UDC 11-3H-4C.4. The public use easement shall
be submitted to the City, approved by City Council and recorded prior to issuance of any Certificate
of Zoning Compliance or, approval of any subsequent land use application for the C-C and TN-C
zoned properties the City Engineer signing the final plat.
4. Right-of-way (ROW) shall be dedicated reserved in the amount required by the Idaho Transportation
Department for the expansion of W. Chinden Boulevard with development of the C-C and TN-C
zoned properties adjacent to Chinden Boulevard.
5. A Certificate of Zoning Compliance and subsequent building permit application is allowed to be
submitted for approval prior to recordation of the first phase of the subdivision where the assisted
living facility is proposed to develop. The first phase final plat shall be recorded prior to issuance of
the Certificate of Occupancy for the assisted living facility.
6. The two accesses via N. Fox Run Way, a collector street, are allowed as depicted on the site plan.
7. Development of the property at the southeast corner of W. Chinden Blvd. and N. Fox Run Way where
the assisted living facility is proposed shall be generally consistent with the concept plan shown in
Exhibit A.4 of the Staff Report that was approved with the Findings of Fact and Conclusions of Law
approved by Meridian City Council on December 8, 2015, attached hereto as Exhibit “B”.
8. A modification of the development agreement is required to include a conceptual development plan
for the TN-C and C-C zoned property located at the southwest corner of W. Chinden Blvd. and N.
Meridian Road and at the southwest corner of W. Chinden Blvd. and N. Fox Run Way prior to
submittal of a Certificate of Zoning Compliance application (if required) or issuance of any building
permits.
The concept plan(s) should include a site plan showing access and circulation; and a mix of at least 3
land use types; and residential densities ranging from 6 to 15 units/acre in the MU-C designated area
and 3 to 8 units/acre in the MDR designated area as required in the Comprehensive Plan (pgs. 27-28
and pg. 20 respectively).
9. Construction of the street buffer landscaping and associated 10-foot wide multi-use pathways along
W. Chinden Blvd. and N. Meridian Road shall be constructed with the final plat for each phase of
development.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 21
Exhibit A.7: Proposed Conceptual Development Plan to be Included in Development Agreement
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 22
Exhibit B: Agency & Department Comments/Conditions
1. PLANNING DIVISION
1.1 Within six (6) months of Council’s approval of the amended development agreement findings and
prior to submittal of a final plat application, the developer shall sign and obtain Council approval
of an amended development agreement that reflects the modifications listed in Exhibits A.6 and
A.7.
1.2 Site Specific Conditions of Approval
1.2.1 Development of the site shall substantially comply with the preliminary plat, landscape plan and
building elevations included in Exhibit A, the conditions of approval listed herein, and the
provisions of the development agreement.
1.2.2 Any fencing constructed on the site shall be consistent with the standards as set forth in UDC 11-
3A-7 and 11-3H-4D.
1.2.3 The preliminary plat included in Exhibit A.2 shall be revised as follows:
a. Depict root barriers for the 6-foot wide parkways shown on the street section for typical local
roads at traffic calming areas, and other areas where parkways are proposed, as set forth in
UDC 11-3A-17.
b. Depict the proposed common driveways in a common lot or easement that is a minimum of
20 feet in width as set forth in UDC 11-6C-3D.
c. Adjust the boundaries of the lots in the Encore portion of the development to comply with all
minimum setbacks of the R-15 district as set forth in UDC Table 11-2A-7 as applicable.
c. Reconfigure the lots to meet the parking standards listed in UDC Table 11-3C-6 for single-
family attached units in the Cadence portion of the development; or, submit and obtain
approval of an application for alternative compliance as set forth in UDC 11-5B-5 with the
final plat application.
1.2.4 The landscape plan included in Exhibit A.3 shall be revised as follows:
a. Depict fencing abutting pathways and common open space lots to distinguish common from
private areas in accord with the standards listed in UDC 11-3A-7A.7.
b. The note for the common driveway on Lot 23, Block 1 references incorrect lot numbers;
revise accordingly.
c. Depict 5’ x 5’ turnout areas every 200 feet for the sidewalk along N. Fox Run Way to comply
with ADA standards; or, reconstruct the sidewalk to 5 feet wide in accord with UDC 11-3A-
17.
d. Include a detail of the fence/wall proposed along W. Chinden Blvd. and N. Meridian Road in
accord with the standards noted in UDC 11-3H-4D.
e. Depict a north/south 5-foot wide pathway within Lot 23, Block 5 between Lots 31 and 32;
and within Lot 12, Block 4 between Lots 23 & 24 and Lots 1 and 35 to connect to the
east/west pathways; and within Lot 6, Block 3.
1.2.5 A total of 8.63 acres (or 24.2%) of qualified open space shall be provided with development as
proposed, minus the area where building lots in the Encore portion of the development may need
to expand to comply with setback requirements.
1.2.6 Site amenities shall be provided for the development as proposed consisting of a swimming pool
and clubhouse in the Encore portion of the development; a swimming pool with a restroom
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 23
facility, tot lot and associated parking area in the Cadence portion of the development; and
segments of the City’s multi-use pathway system along W. Chinden Blvd. and N. Meridian Rd.
1.2.7 A Design Review application is required to be submitted and approved for all single-family
attached structures prior to submittal of a building permit application. Design of the structures
shall comply with the residential standards listed in the Architectural Standards Manual. One
Design Review application may be submitted for the overall development.
1.2.8 An exhibit shall be included in the final plat application that depicts the setbacks, building
envelope, and orientation of the lots and structures that are accessed via common driveways as set
forth in UDC 11-6C-3D.7.
1.2.9 A final plat shall be recorded for this property prior to applying for building permits.
1.2.10 A Certificate of Zoning Compliance and Design Review application is required to be submitted
and approved for the swimming pools, clubhouse, restroom facility and associated parking lot.
1.2 General Conditions of Approval
1.2.1 Comply with all bulk, use, and development standards of the applicable district listed in UDC
Chapter 2 District regulations.
1.2.2 Comply with the provisions for irrigation ditches, laterals, canals and/or drainage courses, as set
forth in UDC 11-3A-6.
1.2.3 Install lighting consistent with the provisions as set forth in UDC 11-3A-11.
1.2.4 Provide a pressurized irrigation system consistent with the standards as set forth in UDC 11 -3A-
15, UDC 11-3B-6 and MCC 9-1-28.
1.2.5 Comply with the sidewalk standards as set forth in UDC 11-3A-17.
1.2.6 Install all utilities consistent with the standards as set forth in UDC 11-3A-21 and 11-3B-5J.
1.2.7 Construct all off-street parking areas consistent with the standards as set forth in UDC 11-3B-5I,
11-3B-8C, and Chapter 3 Article C.
1.2.8 Construct the required landscape buffers consistent with the standards as set forth in UDC 11-3B-
7C (streets).
1.2.9 Construct storm water integration facilities that meet the standards as set forth in UDC 11-3B-
11C.
1.2.10 Protect any existing trees on the subject property that are greater than four-inch caliper and/or
mitigate for the loss of such trees as set forth in UDC 11-3B-10.
1.2.11 Comply with the outdoor service and equipment area standards as set forth in UDC 11-3A-12.
1.2.12 Comply with all provisions of UDC 11-3A-3 with regard to maintaining the clear vision triangle.
2. PUBLIC WORKS DEPARTMENT
2.1 SITE SPECIFIC CONDITIONS OF APPROVAL
2.1.1 A street light plan will need to be included in the final plat application. Street light plan
requirements are listed in section 6-7 of the City's Design Standards. A copy of the standards can
be found at http://www.meridiancity.org/public_works.aspx?id=272
2.2 General Conditions of Approval
2.2.1 Sanitary sewer service to this development is available via extension of existing mains adjacent to
the development. The applicant shall install mains to and through this subdivision; applicant shall
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 24
coordinate main size and routing with the Public Works Department, and execute standard forms
of easements for any mains that are required to provide service. Minimum cover over sewer
mains is three feet, if cover from top of pipe to sub-grade is less than three feet than alternate
materials shall be used in conformance of City of Meridian Public Works Departments Standard
Specifications.
2. Water service to this site is available via extension of existing mains adjacent to the development.
The applicant shall be responsible to install water mains to and through this development,
coordinate main size and routing with Public Works.
3. All improvements related to public life, safety and health shall be completed prior to occupancy
of the structures. Where approved by the City Engineer, an owner may post a performance surety
for such improvements in order to obtain City Engineer signature on the final plat as set forth in
UDC 11-5C-3B.
4. Upon installation of the landscaping and prior to inspection by Planning Department staff, the
applicant shall provide a written certificate of completion as set forth in UDC 11-3B-14A.
5. A letter of credit or cash surety in the amount of 110% will be required for all incomplete
fencing, landscaping, amenities, pressurized irrigation, prior to signature on the final plat.
6. The City of Meridian requires that the owner post with the City a performance surety in the
amount of 125% of the total construction cost for all incomplete sewer, water infrastructure prior
to final plat signature. This surety will be verified by a line item cost estimate provided by the
owner to the City. The applicant shall be required to enter into a Development Surety Agreement
with the City of Meridian. The surety can be posted in the form of an irrevocable letter of credit,
cash deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
7. The City of Meridian requires that the owner post to the City a warranty surety in the amount of
20% of the total construction cost for all completed sewer, and water infrastructure for a duration
of two years. This surety amount will be verified by a line item final cost invoicing provided by
the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
8. In the event that an applicant and/or owner cannot complete non-life, non-safety and non-health
improvements, prior to City Engineer signature on the final plat and/or prior to occupancy, a
surety agreement may be approved as set forth in UDC 11-5C-3C.
9. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
10. It shall be the responsibility of the applicant to ensure that all development features comply with
the Americans with Disabilities Act and the Fair Housing Act.
11. Applicant shall be responsible for application and compliance with any Section 404 Permitting
that may be required by the Army Corps of Engineers.
12. Developer shall coordinate mailbox locations with the Meridian Post Office.
13. All grading of the site shall be performed in conformance with MCC 11-1-4B.
14. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill, where footing would sit atop fill material.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 25
15. The engineer shall be required to certify that the street centerline elevations are set a minimum of
3-feet above the highest established peak groundwater elevation. This is to ensure that the bottom
elevation of the crawl spaces of homes is at least 1-foot above.
16. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation district
or ACHD. The design engineer shall provide certification that the facilities have been installed in
accordance with the approved design plans. This certification will be required before a certificate
of occupancy is issued for any structures within the project.
17. At the completion of the project, the applicant shall be responsible to submit record drawings per
the City of Meridian AutoCAD standards. These record drawings must be received and approved
prior to the issuance of a certification of occupancy for any structures within the project.
18. Street light plan requirements are listed in section 6-5 of the Improvement Standards for Street
Lighting (http://www.meridiancity.org/public_works.aspx?id=272). All street lights shall be
installed at developer’s expense. Final design shall be submitted as part of the development plan
set for approval, which must include the location of any existing street lights. The contractor’s
work and materials shall conform to the ISPWC and the City of Meridian Supplemental
Specifications to the ISPWC. Contact the City of Meridian Transportation and Utility
Coordinator at 898-5500 for information on the locations of existing street lighting.
19. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of
way (include all water services and hydrants). The easement widths shall be 20-feet wide for a
single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but
rather dedicated outside the plat process using the City of Meridian’s standard forms. The
easement shall be graphically depicted on the plat for reference purposes. Submit an executed
easement (on the form available from Public Works), a legal description prepared by an Idaho
Licensed Professional Land Surveyor, which must include the area of the easement (marked
EXHIBIT A) and an 81/2” x 11” map with bearings and distances (marked EXHIBIT B) for
review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO
NOT RECORD. Add a note to the plat referencing this document. All easements must be
submitted, reviewed, and approved prior to signature of the final plat by the City Engineer.
20. Applicant shall be responsible for application and compliance with and NPDES permitting that
may be required by the Environmental Protection Agency.
21. Any existing domestic well system within this project shall be removed from domestic service per
City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Engineering Department at
(208)898-5500 for inspections of disconnection of services. Wells may be used for non-domestic
purposes such as landscape irrigation if approved by Idaho Department of Water Resources
Contact Robert B. Whitney at (208)334-2190.
22. Any existing septic systems within this project shall be removed from service per City Ordinance
Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and
inspections (208)375-5211.
23. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water (MCC 9-1-28.C.1). The applicant should be required to use any existing surface
or well water for the primary source. If a surface or well source is not available, a single-point
connection to the culinary water system shall be required. If a single-point connection is utilized,
the developer will be responsible for the payment of assessments for the common areas prior to
development plan approval.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 26
24. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be tiled per UDC
11-3A-6. In performing such work, the applicant shall comply with Idaho Code 42-1207 and any
other applicable law or regulation.
3. POLICE DEPARTMENT
3.1 The Police Department has no comment on this application.
4. FIRE DEPARTMENT
4.1 One and two family dwellings not exceeding 3,600 square feet require a fire-flow of 1,000 gallons
per minute for a duration of 2 hours to service the entire project. One and two family dwellings in
excess of 3,600 square feet require a minimum fire flow as specified in Appendix B of the
International Fire Code. Fire Hydrant spacing shall be provided as required by Appendix C of the
International Fire Code.
4.2 Final Approval of the fire hydrant locations shall be by the Meridian Fire Department in accordance
with International Fire Code Section (IFC) 508.5.4 as follows:
a. Fire hydrants shall have the 4 ½” outlet face the main street or parking lot drive aisle.
b. Fire hydrants shall not face a street which does not have addresses on it.
c. Fire hydrant markers shall be provided per Public Works specifications.
d. Fire Hydrants shall be placed on corners when spacing permits.
e. Fire hydrants shall not have any vertical obstructions to outlets within 10’.
f. Fire hydrants shall be placed 18” above finished grade to the center of the 4 ½” outlets.
g. Fire hydrants shall be provided to meet the requirements of IFC Section 509.5.
h. Show all proposed or existing hydrants for all new construction or additions to existing
buildings within 1,000 feet of the project.
4.3 In accordance with International Fire Code Section 503.2.5 and Appendix D, any roadway greater
than 150 feet in length that is not provided with an outlet shall be required to have an approved
turn around. Phasing of the project may require a temporary approved turn around on streets
greater than 150' in length with no outlet.
4.4 All entrances, internal roads, drive aisles, and alleys shall have a turning radius of 28’ inside and
48’ outside, per International Fire Code Section 503.2.4.
4.5 All common driveways shall be straight or have a turning radius of 28’ inside and 48’ outside and
have a clear driving surface of 20’ in width capable of supporting an imposed weight of 75,000
GVW, per International Fire Code Section 503.2.
4.6 Provide signage (“No Parking Fire Lane”) for all fire lanes in accordance with International Fire
Code Sections 503.4 & D103.6.
4.7 Ensure that all yet undeveloped parcels are maintained free of combustible vegetation as set forth
in International Fire Code Section 304.1.2.
4.8 Fire lanes, streets, and structures (including the canopy height of mature trees) shall have a
vertical clearance of 13’6 as set forth in International Fire Code Section 503.2.1.
4.9 Operational fire hydrants, temporary or permanent street signs, and access roads with an all weather
surface are required to be installed before combustible construction material is brought onto the site,
as set forth in International Fire Code Section (IFC) 501.4 and Meridian amendment to IFC 10-4-2J.
4.10 All portions of the buildings located on this project must be within 150’ of a paved surface as
measured around the perimeter of the building as set forth in International Fire Code Section 503.1.1.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 27
4.11 Emergency response routes and fire lanes shall not be allowed to have traffic calming devices
installed without prior approval of the Fire Code Official. National Fire Protection Standard 1141,
Section A5.2.18.
5. REPUBLIC SERVICES
5.1 Republic Services did not submit comments on this application.
6. PARKS DEPARTMENT
6.1 The developer shall submit 14-foot wide public pedestrian easements for the proposed multi-
use pathways within the boundary of this subdivision; coordinate the details of such with Jay
Gibbons, Pathways Project Manager., at 208-888-3579.
7. ADA COUNTY HIGHWAY DISTRICT
7.1 Site Specific Conditions of Approval
7.1.1 Comply with the requirements of ITD and City of Meridian for any project improvements within
the State right-of-way for the US-20/26/ Chinden Boulevard frontage. Submit to the District
copies of State right-of-way permits, if any, prior to District approval of the final plat.
7.1.2 Dedicate 37-feet of right-of-way from the centerline of Meridian Road abutting the site.
Construct a 5-foot wide detached concrete sidewalk located a minimum of 30-feet from the
centerline of Meridian Road abutting the site. Provide a permanent right-of-way easement if
public sidewalks are located outside of the dedicated right-of-way.
7.1.3 Reconstruct the sidewalk on Fox Run Way abutting the site to be 5-feet in width or provide 5’ x
5’ turnout areas every 200 feet to meet ADA standards.
7.1.4 Replace any broken or deteriorated portions of curb and gutter on Director Street abutting the site.
7.1.5 Extend two stub streets, Garbo Way and Peppard Avenue into the site. Construct the entry
portion of both roadways with two 20-foot wide travel lanes, a 12-foot wide center landscape
island, curb, gutter, an 8-foot wide planter strip, and 5-foot wide detached concrete sidewalks.
7.1.6 Dedicate the center landscape islands on Garbo Way and Peppard Avenue as right-of-way owned
by ACHD. The applicant or the home owners association shall enter into a license agreement
with ACHD for any landscaping to be located within the center landscape islands.
7.1.7 Construct the internal local streets as 33-foot street sections with rolled curb, gutter, and 5-foot
wide attached concrete sidewalks within 47-feet of right-of-way, as proposed.
7.1.8 Construct bulb-outs though out the site on all of the internal local street, as proposed. Construct
the bulb-out to provide a minimum of 24-feet of pavement from back of curb to back of curb and
with a minimum inside radius 26-feet.
7.1.9 Provide written Fire Department approval for use of the reduced street section and the bulb-outs.
7.1.10 Provide a permanent right-of-way easement for all sidewalks located outside of the dedicated
right-of-way.
7.1.11 If parking lots are constructed on any street they shall be located entirely outside of the right-of-
way. Construct a 5-foot wide concrete sidewalk around the outside of the parking lots tying into
the sidewalk on either side.
7.1.12 Terminate Channing Way at Everest Drive and construct a driveway to provide secondary
emergency access and access to 2 building lots.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 28
7.1.13 Construct one 24-foot wide driveway onto Garbo Way located 230-feet north of Director Street,
as proposed. Pave the driveway its full width at least 30-feet into the site beyond the edge of
pavement of Garbo Way.
7.1.14 Construct one 24-foot wide driveway onto Mitchum Avenue, located 65-feet south of Boulder
Bar Drive, as proposed. Pave the driveway its full width at least 30-feet into the site beyond the
edge of pavement of Mitchum Avenue.
7.1.15 Direct lot access is prohibited to Meridian Road, Fox Run Way, and Director Street and shall be
noted on the final plat.
7.1.16 Payment of impacts fees are due prior to issuance of a building permit.
7.1.17 Comply with all Standard Conditions of Approval.
7.2 Standard Conditions of Approval
7.2.1 All proposed irrigation facilities shall be located outside of the ACHD right -of-way
(including all easements). Any existing irrigation facilities shall be relocated outside of the
ACHD right-of-way (including all easements).
7.2.2 Private Utilities including sewer or water systems are prohibited from being located within
the ACHD right-of-way.
7.2.3 In accordance with District policy, 7203.3, the applicant may be required to update any
existing non-compliant pedestrian improvements abutting the site to meet current
Americans with Disabilities Act (ADA) requirements. The applicant’s engineer should
provide documentation of ADA compliance to District Development Review staff for
review.
7.2.4 Replace any existing damaged curb, gutter and sidewalk and any that may be damaged
during the construction of the proposed development. Contact Construction Services at
387-6280 (with file number) for details.
7.2.5 A license agreement and compliance with the District’s Tree Planter policy is required for
all landscaping proposed within ACHD right-of-way or easement areas.
7.2.6 All utility relocation costs associated with improving street frontages abutting the site shall
be borne by the developer.
7.2.7 It is the responsibility of the applicant to verify all existing utilities within the right-of-way.
The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant.
The applicant shall be required to call DIGLINE (1-811-342-1585) at least two full
business days prior to breaking ground within ACHD right -of-way. The applicant shall
contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits (spare or
filled) are compromised during any phase of construction.
7.2.8 Utility street cuts in pavement less than five years old are not allowed unless approved in
writing by the District. Contact the District’s Utility Coordinator at 387-6258 (with file
numbers) for details.
7.2.9 All design and construction shall be in accordance with the ACHD Policy Manual, ISPWC
Standards and approved supplements, Construction Services procedures and all applicable
ACHD Standards unless specifically waived herein. An engineer registered in the State of
Idaho shall prepare and certify all improvement plans.
7.2.10 Construction, use and property development shall be in conformance with all applicable
requirements of ACHD prior to District approval for occupancy.
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 29
7.2.11 No change in the terms and conditions of this approval shall be valid unless they are in
writing and signed by the applicant or the applicant’s authorized representative and an
authorized representative of ACHD. The burden shall be upon the applicant to obtain
written confirmation of any change from ACHD.
7.2.12 If the site plan or use should change in the future, ACHD Planning Review will review the
site plan and may require additional improvements to the transportation system at that time.
Any change in the planned use of the property which is the subject of this application, shall
require the applicant to comply with ACHD Policy and Standard Conditions of Approval in
place at that time unless a waiver/variance of the requirements or other legal relief is
granted by the ACHD Commission.
8. IDAHO TRANSPORTATION DEPARTMENT
(See following page)
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 30
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 31
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 32
Exhibit C: Legal Description and Exhibit Map for Rezone
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 33
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 34
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 35
Exhibit D: Required Findings from Unified Development Code
1. REZONE:
Upon recommendation from the Commission, the Council shall make a full investigation and
shall, at the public hearing, review the application. In order to grant an annexation and/or rezone,
the Council shall make the following findings:
a. The map amendment complies with the applicable provisions of the Comprehensive
Plan;
Staff finds the proposed density and associated R-15 zoning is consistent with the applicable
provisions of the Comprehensive Plan in regard to the MU-C and MDR future land use map
designations for this site.
b. The map amendment complies with the regulations outlined for the proposed district,
specifically the purpose statement;
Staff finds that the proposed map amendment and subsequent development will contribute to
the range of housing opportunities available in the northern portion of the City.
c. The map amendment shall not be materially detrimental to the public health, safety,
and welfare;
Staff finds that the proposed zoning amendment will not be materially detrimental to the
public health, safety, or welfare. However, Staff recommends that the Commission and
Council consider any oral or written testimony that may be provided when determining this
finding.
d. The map amendment shall not result in an adverse impact upon the delivery of services
by any political subdivision providing public services within the City including, but not
limited to, school districts; and,
Staff finds that the proposed zoning amendment will not result in any adverse impact upon
the delivery of services by any political subdivision providing services to this site.
e. The annexation is in the best of interest of the City (UDC 11-5B-3.E).
Because this application is for a rezone, this finding is not applicable.
2. PRELIMINARY PLAT:
In consideration of a preliminary plat, combined preliminary and final plat, or short plat, the
decision-making body shall make the following findings:
a. The plat is in conformance with the Comprehensive Plan;
Staff finds that the proposed plat is in substantial compliance with the adopted
Comprehensive Plan in regard to density, transportation, and circulation. Please see
Comprehensive Plan Policies and Goals, Section VII, of the Staff Report for more
information.
b. Public services are available or can be made available and are adequate to
accommodate the proposed development;
Staff finds that public services will be provided to the subject property upon development.
(See Exhibit B of the Staff Report for more details from public service providers.)
Paramount Director MDA, PP, RZ H-2016-0104 PAGE 23
c. The plat is in conformance with scheduled public improvements in accord with the
City’s capital improvement program;
Because City water and sewer and any other utilities will be provided by the developer at
their own cost, Staff finds that the subdivision will not require the expenditure of capital
improvement funds.
d. There is public financial capability of supporting services for the proposed
development;
Staff recommends the Commission and Council rely upon comments from the public service
providers (i.e., Police, Fire, ACHD, etc.) to determine this finding. (See Exhibit B for more
detail.)
e. The development will not be detrimental to the public health, safety or general welfare;
and
Staff is not aware of any health, safety, or environmental problems associated with the
platting of this property that should be brought to the Commission or Council’s attention.
ACHD and ITD consider road safety issues in their analysis. Staff recommends that the
Commission and Council consider any public testimony that may be presented when
determining whether or not the proposed subdivision may cause health, safety or
environmental problems of which Staff is unaware.
f. The development preserves significant natural, scenic or historic features.
Staff is unaware of any significant natural, scenic or historic features that exist on this site.