Loading...
CC - Water Amenity Letter(JUf J•11•8 ENGINEERS, INC. September 13, 2016 Sonya Allen Associate City Planner City of Meridian 33 E. Broadway Avenue, Suite 102 Meridian, Idaho 83642 RE: HOWRY LANE SUBDIVISION WATER AMENITY Dear Sonya: I THE MAPPINGATEWAY PPIN i LANGDON M11.O GROUP 01 INC. The existing irrigation drain ditch located within the proposed Howry Lane Subdivision will be retained as an open ditch and utilized as a "Water Amenity," per the standards of Meridian UDC 11-1A-1. The ditch runs diagonally through the site from southeast to northwest and is located within Blocks 2, 4, and 5. The drain ditch will be regraded to provide 4:1 max side slopes and a longitudinal grade of 0.38%. The existing flow rate through the ditch was measured on September 12, 2016, and was determined to be 3.30 cfs. Based on the existing flow rate, the proposed ditch would have a max velocity of 2.22 ft/s and a depth of 0.61-ft. The product of the flow velocity multiplied by the flow depth is 1.35, which is less than the maximum value of 4 required by UDC 11-1A-1. Please feel free to contact me at (208) 376-7330 if you have any questions. Sincerely, J-U-B ENGIN Scott Wonde Land Development croup Leaa a 250 S. Beechwood Avenue, Suite 201, Boise, ID 83709-0944 p 208-376-7330 f 208-323-9336 N, www.jub.com