Loading...
Staff Report - PZItem #41: Carl's Jr at Chinden and Linder Crossing (CUP-15.007) ➢ Conditional Use Permit Property location: The subject property is located near the northwest corner of W. Chinden Boulevard and N. Linder Road. Adjacent Land Use & Zoning: North: County residences, zoned RUT in Ada County East: Vacant commercial development, zoned C-C South: Knighthill Center Subdivision and a vacant commercial lot, zoned C-N and C-G West: Proposed Primary Health, zoned C-C History: In 2014, this property received preliminary plat, final plat and development agreement modification (PP-14-011, FP- 14-041 and MDA-14-008) approval to develop a nine (9) lot commercial subdivision known as Chinden and Linder Crossing. The property is subject to a new development agreement that recorded as Instrument No. 2014-088001. The approved final plat requires the recordation of plat prior to applying for a building permit. Comprehensive Plan: MU-C Summary of Request: The applicant has applied for a conditional use permit (CUP) to construct a drive -through establishment for a Carl's Jr restaurant in a C-C zoning district. The CUP is required because the proposed drive -through is within 300 feet of existing residential uses to the north. Staff has reviewed this site for conformance with the drive -through establishment specific use standards. Modifications to the site plan are required per the conditions of approval in Exhibit B of the staff report. The landscape buffers adjacent to Chinden Boulevard and W. Green Island Drive have been reviewed and approved with the Chinden and Linder Crossing Subdivision. These improvements must be completed in accord with the approved final plat. Parking lot landscaping is required to comply with the standards listed in UDC 11-313-8C. Building materials consist primarily of stucco with brick veneer accents. The proposed building elevations appear to generally comply with the design standards listed in UDC 11-3A-19 and the Meridian Design Manual. Written Testimony: None Staff Recommendation: Approval w/ Conditions in Exhibit B of the staff report Notes: STAFF REPORT Hearing Date TO: FROM: SUBJECT May 21, 2015 Planning and Zoning Commission Bill Parsons, Planning Supervisor 208-884-5533 C �E IMAM--, 1DAHO Bruce Freckleton, Development Services Manager 208-887-2211 CUP-15-007 — Carl's Jr at Chinden and Linder Crossing I. SUMMARY DESCRIPTION OF APPLICANT'S REQUEST The applicant, John Nelson, has applied for a conditional use permit (CUP) for a drive -through establishment for a Carl's Jr restaurant in a C-C zoning district. A CUP is required because the proposed drive -through is within 300 feet of existing single-family residences to the north. See Section IXAnalysis for more information. II. SUMMARY RECOMMENDATION Staff recommends approval of the proposed CUP with the conditions listed in Exhibit B, based on the Findings of Fact and Conclusions of Law in Exhibit C of the Staff Report. III. PROPOSED MOTION Approval After considering all staff, applicant and public testimony, I move to approve File Number CUP-15- 007 as presented in the staff report for the hearing date of May 21, 2015, with the following modifications: (Add any proposed modifications.) I further move to direct Staff to prepare an appropriate findings document to be considered at the next Planning and Zoning Commission hearing on June 4, 2015. Denial After considering all staff, applicant and public testimony, I move to deny File Number CUP-15-007 as presented during the hearing on May 21, 2015, for the following reasons: (You should state specific reasons for denial and what the applicant could do to gain your approval with another application.) Continuance I move to continue File Number CUP-15-007 to the hearing date of (insert continued hearing date here) for the following reason(s): (You should state specific reason(s) for continuance.) IV. APPLICATION AND PROPERTY FACTS A. Site Address/Location: The subject property is located near the northwest corner of W. Chinden Boulevard and N. Linder Road, in the SE'/4 of Section 23, Township 4 North, Range 1 West. (Parcel #R1065270177) B. Owner(s): FAE Holding 450070R, LLC 2700 W. Airport Way Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 1 Boise, ID 83715 C. Applicant: John Nelson 13601 W. McMillan Road, Suite #102 Boise, ID 83713 D. Applicant's Statement/Justification: Please see applicant's narrative for this information. V. PROCESS FACTS A. The subject application is for a conditional use permit. A public hearing is required before the Planning and Zoning Commission on this matter, consistent with Meridian City Code Title 11, Chapter 5. B. Newspaper notifications published on: May 4, and 18, 2015 C. Radius notices mailed to properties within 300 feet on: April 30, 2015 D. Applicant posted notice on site by: May 7, 2015 VI. LAND USE A. Existing Land Use(s) and Zoning: The subject property is currently vacant commercial property, zoned C-C. B. Character of Surrounding Area and Adjacent Land Use and Zoning: 1. North: County residences, zoned RUT in Ada County 2. East: Vacant commercial development, zoned C-C 3. South: Knighthill Center Subdivision and a vacant commercial lot, zoned C-N and C-G 4. West: Proposed Primary Health, zoned C-C C. History of Previous Actions: • In 2014, this property received preliminary plat, final plat and development agreement modification (PP-14-011, FP-14-041 and MDA-14-008) approval to develop a nine (9) lot commercial subdivision known as Chinden and Linder Crossing. The property is subject to a new development agreement that recorded as Instrument No. 2014-088001. The approved final plat requires the recordation of plat prior to applying for a building permit. D. Utilities: 1. Public Works: a. Location of sewer: Sanitary sewer service to the area will be provided via an extension form an existing main W. Island Green Drive. b. Location of water: Water service to the area will be provided by United Water of Idaho. c. Issues or concerns: None E. Physical Features: 1. Canals/Ditches Irrigation: No major facilities transverse this property. 2. Hazards: Staff is not aware of any hazards that exist on this site. 3. Flood Plain: This site is not within a flood plain. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 2 VII. COMPREHENSIVE PLAN POLICIES AND GOALS This property is designated "Mixed Use — Community (MU-C)" on the Comprehensive Plan Future Land Use Map. The purpose of this designation is to allocate areas where community -serving uses and dwellings are seamlessly integrated. Featured elements of the mixed use development should include the following: • Residential densities at a minimum of 6 to 15 dwelling units to the acre; • A conceptual site plan; • Provide community serving facilities; • Provide some form of common, usable area, such as a plaza or green space; • Landscape buffering between commercial and existing low or medium density residential; • Three different types of land uses and; • Be accessible to neighborhoods by both vehicles and pedestrians; • Commercial building footprints should not exceed 30,000 square feet. During the review of the Chinden and Linder Crossing Subdivision, a concept plan was subsequently approved that incorporated many of the design concepts noted above. The proposed use of the property as a restaurant with a drive -through is consistent with the uses desired in MU-C designated areas and therefore is consistent with the Comprehensive Plan and the approved concept plan. Staff finds the following Comprehensive Plan policies to be applicable to this property and apply to the proposed use (staff analysis in italics): 1. "Require landscape street buffers for new development along all entryway corridors." (2.01.02E) A 35 foot wide landscape buffer is required along W. Chinden Boulevard, an entryway corridor, in accord with the standards listed in UDC 11-3B-7C Landscape Buffers along Streets. This buffer is to be installed with the Chinden and Linder Crossing Subdivision. 2. "Plan for and encourage services like health care, daycare, grocery stores and recreational areas to be built within walking distance of residential dwellings." (2.01.01 C) The proposed restaurant will be located within walking distance of several near -by residential neighborhoods. 3. "Reduce the number of existing access points onto arterial streets by using methods such as cross -access agreements, access management, and frontage/backage roads." (3.03.020) With the approval of the Chinden and Linder Crossing Subdivision, a backage road was approved that connects the residential subdivision to the west and this development to Linder Road; a right-in/right-out provides access to Chinden Boulevard. 4. "Require all new and reconstructed parking lots to provide landscaping in internal islands and along streets." Planter islands are proposed in the parking area and will be landscaped in accord with the standards listed in UDC I1-3B-8C. 5. "Minimize noise, odor, air pollution, and visual pollution in industrial and commercial development adjacent to residential areas." (3.06.0113) The proposed drive -through is oriented towards Chinden Boulevard and the applicant is proposing a 28 foot wide landscape buffer along the north boundary to minimize impacts to the near -by residents. 6. "Plan for a variety of commercial and retail opportunities within the Area of City Impact." Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 3 (3.05.01J) The proposed restaurant with a drive -through will contribute to the variety of services available in the northern portion of the City. For the above -stated reasons, staff believes the proposed use is consistent with the applicable comprehensive plan policies and is appropriate in this location. VIII. UNIFIED DEVELOPMENT CODE A. Purpose Statement of Zone: The purpose of the commercial districts is to provide for the retail and service needs of the community in accordance with the Meridian comprehensive plan. Six (6) districts are designated which differ in the size and scale of commercial structures accommodated in the district, the scale and mix of allowed commercial uses, and the location of the district in proximity to streets and highways. B. Schedule of Use: Unified Development Code (UDC) 11-213-2 lists the permitted, accessory, conditional, and prohibited uses in the C-C zoning district. A restaurant is a principal permitted use in the C-C zoning district; a drive -through establishment requires conditional use permit approval when located within 300 feet of a residence, residential use, or another drive-thru establishment; subject to the specific use standards set forth in UDC 11-4-3-11. C. Dimensional Standards: The dimensional standards listed in UDC Table 11-213-3 for the C-C zoning district apply to development of this site. D. Landscaping: • Street buffer landscaping shall be installed in accordance with the standards listed in UDC Table11-213-3 and UDC 11-3B-7C for the C-C zoning district. • Parking lot landscaping: All parking lot landscaping shall comply with the standards listed in UDC 11-313-8C. E. Off -Street Parking: Off-street parking is required in accord with UDC 11-3C-6B for the commercial lots. F. Structure and Site Design Standards: Development of this site must comply with the design standards in accord with UDC 11-3A-19. IX. ANALYSIS A. Analysis of Facts Leading to Staff Recommendation: Conditional Use Permit (CUP): The applicant has applied for a conditional use permit (CUP) to construct a drive -through establishment for a Carl's Jr restaurant in a C-C zoning district. The CUP is required because the proposed drive -through is within 300 feet of existing residential uses (north), per UDC Table 11-213-2. Drive -through Establishment: Per UDC 11-4-3-11, the following specific use standards apply to the proposed drive -through use as follows: A. All establishments providing drive -through service shall identify the stacking lane, speaker location, and window location on the plans submitted with the Certificate of Zoning Compliance (CZC) application. All items are accounted for on the submitted site plan. These items must also be included on the site plan submitted with the CZC application. B. Stacking lanes shall have sufficient capacity to prevent obstruction of the public right-of-way by patrons. The submitted site plan demonstrates the stacking lane will Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 4 not obstruct any public right-of-way however; staff is recommending additional signage and striping to clearly delineate the stacking lane from the drive aisle (see below). C. The stacking lane shall be a separate lane from the circulation lanes needed for access and parking. On the submitted site plan, it appears the stacking lane can accommodate several vehicles. To minimize the conflicts with the stacking lane and the circulation needs for the site, staff recommends the following modifications to the site plan with the submittal of the Certificate of Zoning Compliance application: 1) North of the exit lane on the east boundary of the site, the applicant shall construct another planter island to clearly define the drive aisles with the property to the east OR submit written documentation from the owners of the adjacent property to the east that states they will construct the required landscape island with the development of their site; 2) The stacking/drive-through lane shall be striped and signed along the west boundary to delineate the stacking/drive-through lane from the drive aisle; 3) The drive aisle adjacent to the stacking/drive-through lane shall be striped as one-way and the central planter island on the east boundary of the one-way drive -aisle and on the east side of the trash enclosure should be extended so that the entrance into the parking area is narrowed to IS feet to minimize conflicts with the stacking/drive-through lane, and 4) Republic Services has requested that the applicant construct a wider trash enclosure (18 feet) to also accommodate recycling. The applicant shall coordinate with Bob Olson regarding the specifics of the trash enclosure. If these changes are incorporated into the site plan, Staff believes there is adequate stacking capacity and site circulation for the proposed drive -through. D. The stacking lane shall not be located within ten feet (10') of any residential district or existing residence. NA (The proposed stacking lanes are not within 10 feet of a residential district or residence. The nearest residence is approximately 290 feet away to the north) E. Any stacking lane greater than one hundred feet (100') in length shall provide for an escape lane. The stacking lane depicted on the submitted site plan is in excess of 100 feet. An escape lane has been provided along the west boundary to allow vehicles to exit the drive -through in accord with this standard. With the submittal of the CZC application, the applicant should sign and strip that area with do not enter markings to ensure motorist do not enter the drive -through at this location. Site Plan: A site plan is included in Exhibit A.2 that depicts how the site is proposed to develop with a 2,799 square foot (s.£) restaurant with a drive -through. In general, the submitted complies with the district regulations of the UDC. Access: Access to the proposed development was approved with the Chinden and Linder Crossing Subdivision. The approved access points consist of a backage road (W. Island Green Drive) and right-in/right-out access to Chinden Boulevard. A reciprocal cross -access agreement was also required with the platting of the property in accord with UDC 11-3A-3. Parking: Based on the overall square footage of the building (2,799 s.f.), a minimum of 6 vehicle parking spaces are required to be provided on the site per the standards listed in UDC 11-3C-613. A total of 27 parking stalls are proposed, in excess of the UDC minimum requirements. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 5 A bike rack is depicted on the site plan per UDC 11-3C-6G in accord with the standards listed in UDC 11-3C-5C. Landscaping: The landscape buffers adjacent to Chinden Boulevard and W. Green Island Drive have been reviewed and approved with the Chinden and Linder Crossing Subdivision. These improvements must be completed in accord with the approved final plat. Parking lot landscaping is required to comply with the standards listed in UDC 11-313-8C. Hours of Operation: The proposed hours of operation are from 8:00 am to 12:00 am, seven (7) days a week. In the C-C district, hours of operation shall be restricted between the hours of 6:00 am and 11:00 pm when the property abuts a residential district or use. Because the proposed drive -through establishment does not abut a residential district or use, staff is supportive of the proposed hours of operation. Sidewalk: A 5-foot wide attached sidewalk is proposed along east side of the commercial drive aisle and the south side of W. Island Green Drive in accord with UDC 1 I-3A-17. A 10-foot wide multi -use pathway was required along Chinden Boulevard with the approval of the Chinden and Linder Crossing Subdivision. A pedestrian walkway is depicted on the site plan from the perimeter sidewalk along Chinden Boulevard to the main building entrance; it must be delineated from the driving surface by pavers, brick or scored concrete in accord with UDC 11-3A-19A.4. Building Elevations: Building elevations were submitted for the proposed structure as shown in Exhibit A.4. Building materials consist primarily of stucco with brick veneer accents. The proposed building elevations appear to generally comply with the design standards listed in UDC 11-3A-19 and the Meridian Design Manual. Certificate of Zoning Compliance (CZC) and Design Review (DES): A CZC and DES application is required to be submitted prior to issuance of building permits. The applicant must comply with the design standards listed in UDC 11-3A-19 and the guidelines contained in the Meridian Design Manual. Staff recommends approval of the proposed CUP with the conditions listed in Exhibit B. X. EXHIBITS A. Drawings 1. Vicinity Map 2. Site Plan (dated: 04/03/15) 3. Landscape Plan (dated: 04/22/15) 4. Building Elevations (dated: 04/03/15) B. Conditions of Approval 1. Planning Division 2. Public Works Department 3. Fire Department 4. Police Department 5. Sanitary Service Company 6. Ada County Highway District 7. Parks Department C. Required Findings from Unified Development Code Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 6 Exhibit A.1: Vicinity Map Vicinity Map Legend i Area of I �...... _. Parcels- 0 0.15 0.3 Miles The nfamaUon shown on this map is compiled 6om ' vanous sources and is SUt>fect to constant reunion. The City of Meridian makes no warranty or guarantee as to the mmem, accuracy, bmelm-S, or oxmletenesf Of any of the data provided, and assumes no legal responsibility for the -; MOnMatm conlaned M this map. 1���f��i� i w Mind"- &nRlv R i�itri - i�ieieinii ■ c o� ^JY L-o C-N C-G 2 J W Everest t.n W Boulder Bar Dr l�l,� ' J� w Grand Teton Dr RUT jW Tango Creek Dr as W Rattlesnake Dr i d,.. E IDIAN; Print Date: 6/30/2014 Vicinity Map Print Date: 650/2014 0 0.175 0.35 Miles Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 7 Exhibit A.2: Site Plan (dated: 04/03/15) Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 8 Exhibit A.3: Landscape Plan (dated: 04/22/15) , rw 0 •.ar �w •w •ra Qs wwr wwrrr a_ O fwanww wa• OM Fn_•r� rr ssessesx�s- •.••w•.. wnrr_wwwf.wfr. •-irw rL•wr y} V J;... am 'M� r•.a Aw— StS�lxS� ��wr• i ii7Fitir✓mow a••.w_ iiT,fa•w..r DRUPA x i ii aAP a *AVTA LAUMCM PL M Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 9 Exhibit A.4: Building Elevations (dated: 04/03/15) Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 10 B. Conditions of Approval 1. PLANNING DIVISION 1.1 The applicant shall comply with all previous conditions of approval associated with this site (PP- 14-011; FP- 14-041; DA #2014-088001). 1.2 A building permit will not be issued for this development until the final plat is recorded. 1.3 The applicant shall comply with the specific use standards listed in UDC 11-4-3-11, Drive - Through Establishment. 1.4 The site and/or landscape plans included in Exhibit A, dated 3/6/15 shall be revised as follows (as applicable): a. North of the exit lane on the east boundary of the site, the applicant shall construct another planter island to clearly define the drive aisles with the property to the east OR submit written documentation from the owner of the adjacent property to the east that states they will construct the landscape island with the development of the eastern lot; b. The stacking/drive-through lane shall be striped and signed along the west boundary to delineate the stacking/drive-through lane from the drive aisle; c. The drive aisle adjacent to the stacking/drive-through lane shall be striped as one-way and the central planter island on the east boundary of the one-way drive -aisle and on the east side of the trash enclosure should be extended so that the entrance into the parking area is narrowed to 1 S feet to minimize conflicts with the stacking/drive-through lane, and d. The applicant shall coordinate with Bob Olson, Republic Services regarding the trash enclosure being widened to 18 feet. e. With the submittal of the CZC application, the applicant shall sign and stripe the escape lane with do not enter markings to ensure motorist do not enter the drive -through the wrong way. f. The pedestrian walkway that is depicted on the site plan from the perimeter sidewalk along Chinden Boulevard to the main building entrance shall be delineated/distinguished from the driving surface by pavers, brick or scored concrete in accord with UDC 11-3A-19A.4. 1.5 Development of this site shall substantially comply with the approved site plan, landscape plan and building elevations and the conditions of approval listed herein. 1.6 The applicant is required to submit a Certificate of Zoning Compliance application for approval of the proposed use and site layout from the Planning Division prior to submittal of a building permit application. 1.7 The applicant shall submit a Design Review application concurrent with the Certificate of Zoning Compliance application for approval of the site layout and building elevations. The proposed site layout and structures are required to comply with the design standards listed in UDC 11-3A-19 and the guidelines contained in the Meridian Design Manual. 1.8 Staff's failure to cite specific ordinance provisions or terms of the approved conditional use does not relieve the applicant of responsibility for compliance. 1.9 The Applicant shall have a maximum of two (2) years to commence the use as permitted in accord with the conditions of approval listed above. If the use has not begun within two (2) years of approval, a new conditional use permit must be obtained prior to operation or a time extension must be requested in accord with UDC 11-513-617. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 11 1.10 The applicant shall complete all required improvements prior to issuance of a Certificate of Occupancy. It is unlawful to use or occupy any building or structure until the Building Official has issued a Certificate of Occupancy. 2. PUBLIC WORKS DEPARTMENT 2.1 Public Works has no concerns with this application. 3. FIRE DEPARTMENT 3.1 Final Approval of the fire hydrant locations shall be by the Meridian Fire Department in accordance with International Fire Code Section (117C) 508.5.4 as follows: a. Fire hydrants shall have the 4 '/2" outlet face the main street or parking lot drive aisle. b. Fire hydrants shall not face a street which does not have addresses on it. c. Fire hydrant markers shall be provided per Public Works specifications. d. Fire Hydrants shall be placed on corners when spacing permits. e. Fire hydrants shall not have any vertical obstructions to outlets within 10'. f. Fire hydrants shall be placed 18" above finished grade to the center of the 4 %2" outlets. g. Fire hydrants shall be provided to meet the requirements of IFC Section 509.5. h. Show all proposed or existing hydrants for all new construction or additions to existing buildings within 1,000 feet of the project. 3.2 All entrances, internal roads, drive aisles, and alleys shall have a turning radius of 28' inside and 48' outside, per International Fire Code Section 503.2.4. 3.3 Ensure that all yet undeveloped parcels are maintained free of combustible vegetation as set forth in International Fire Code Section 304.1.2. 3.4 Operational fire hydrants, temporary or permanent street signs, and access roads with an all weather surface are required to be installed before combustible construction material is brought onto the site, as set forth in International Fire Code Section (IFC) 501.4 and Meridian amendment to IFC 10-4-2J. 3.5 Maintain a separation of 5' from the building to the dumpster enclosure as set forth in International Fire Code Section 304.3.3. 3.6 Provide a Knox box entry system for the complex prior to occupancy as set forth in International Fire Code Section 506. 4. POLICE DEPARTMENT 4.1 The Police Department has no concerns with this application. 5. REPUBLIC SERVICES 5.1 The applicant shall coordinate with Bob Olson, Republic Services, on the design of the trash enclosure. 6. ADA COUNTY HIGHWAY DISTRICT (NO COMMENTS WERE SUBMITTED BY ACHD) 7. PARKS DEPARTMENT 7.1 The Parks Department did not submit comments on this application. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 12 C. Required Findings from Unified Development Code 1. Conditional Use Permit (UDC 11-5B-6E) The Commission shall base its determination on the Conditional Use Permit request upon the following: a. That the site is large enough to accommodate the proposed use and meet all the dimensional and development regulations in the district in which the use is located. Staff finds that the subject property is large enough to accommodate the proposed use and the dimensional & development regulations of the C-C district as required by the UDC (see Analysis Section IX for more information). b. That the proposed use will be harmonious with the Meridian Comprehensive Plan and in accord with the requirements of this Title. Staff finds that the proposed use is consistent and harmonious with the UDC and Comprehensive Plan Future Land Use Map designation of MU-C for this site if designed in accord with the conditions listed in Exhibit B. c. That the design, construction, operation and maintenance will be compatible with other uses in the general neighborhood and with the existing or intended character of the general vicinity and that such use will not adversely change the essential character of the same area. Staff finds that if the applicant complies with the conditions outlined in this report, the proposed use should be compatible with other uses in the general neighborhood, with the existing and intended character of the area, and with other existing and future uses in the C-C zoning district. d. That the proposed use, if it complies with all conditions of the approval imposed, will not adversely affect other property in the vicinity. Staff finds that if the applicant complies with the conditions outlined in this report, the proposed use will not adversely affect other property in the area. e. That the proposed use will be served adequately by essential public facilities and services such as highways, streets, schools, parks, police and fire protection, drainage structures, refuse disposal, water, and sewer. Staff finds that sanitary sewer, domestic water, refuse disposal, and irrigation are currently provided to the subject property. Staff finds that the proposed use will be served adequately by all of the public facilities and services listed above. f. That the proposed use will not create excessive additional costs for public facilities and services and will not be detrimental to the economic welfare of the community. If approved, the applicant will be financing any improvements required for development. Staff finds there will not be excessive additional requirements at public cost and that the proposed use will not be detrimental to the community's economic welfare. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 13 g. That the proposed use will not involve activities or processes, materials, equipment and conditions of operation that will be detrimental to any persons, property or the general welfare by reason of excessive production of traffic, noise, smoke, fumes, glare or odors. Staff finds the proposed use will not be detrimental to any persons, property or the general welfare of the area. h. That the proposed use will not result in the destruction, loss or damage of a natural, scenic or historic feature considered to be of major importance. Staff finds that there should not be any health, safety or environmental problems associated with the proposed use. Further, staff finds that the proposed use will not result in the destruction, loss or damage of any natural, scenic or historic feature of major importance. Carl's Jr at Chinden and Linder Crossing CUP-15-007 PAGE 14