Loading...
Hill's Century Farm Subdivision No. 2 FP-15-005BEFORE THE MERIDIAN CITY COUNCIL IN THE MATTER OF THE REQUEST FOR FINAL PLAT CONSISTING OF 56 BUILDABLE LOTS AND 9 COMMON LOTS ON 19.78 ACRES OF LAND IN AN R-8 ZONING DISTRICT FOR HILL'S CENTURY FARM SUBDIVISION NO.2 BY: BRIGHTON INVESTMENTS, LLC APPLICANT HEARING DATE: MARCH 3, 2015 CASE NO. FP -15-005 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council on March 3, 2015 for final plat approval pursuant to Unified Development Code (UDC) 11-6B-3 and the Council finding that the Administrative Review is complete by the Planning Department and Public Works Department, to the Mayor and Council, and the Council having considered the requirements of the preliminary plat, the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Final Plat of "PLAT SHOWING HILL'S CENTURY FARM SUBDIVISION PHASE 2, LOCATED IN A PORTION OF THE S''/z OF THE NW '/4 , SECTION 33, TOWNSHIP 3 NORTH, RANGE 1 EAST, BOISE MERIDIAN, CITY OF MERIDIAN, ADA COUNTY, IDAHO, 2015, HANDWRITTEN DATE: JANUARY 21, 2015, AARON L. BALLARD, PLS, ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR HILL'S CENTURY FARM SUBDIVISION NO. 2 (FP -15-005) Pagel of 3 SHEET 1 OF 4," is conditionally approved subject to those conditions of Staff as set forth in the staff report to the Mayor and City Council from the Planning and Development Services divisions of the Community Development Department dated March 3, 2015, a true and correct copy of which is attached hereto marked "Exhibit All and by this reference incorporated herein, and the response letter from Mike Wardle, a true and correct copy of which is attached hereto marked "Exhibit B" and by this reference incorporated herein. 2. The final plat upon which there is contained the certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 2.1 The plat dimensions are approved by the City Engineer; and 2.2 The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash surety has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code § 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR HILL'S CENTURY FARM SUBDIVISION NO. 2 (FP -15-005) Page 2 of 3 Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty- eight (28) days after the date of this decision and order, seek a judicial review pursuant to Idaho Code§ 67-52. By action of the City Council at its regular meeting held on the day of 2015. B �Qo�PTcn nu��� a 9 Mayor, Ci f Meridian Attest: cn-�r TITIAN* �o=_x o� SL L cee H FR o �E city Cl �rn,rzEr�° Copy served upon the Applicant, Community Development Department, Public Works Department, and City Attorney. Dated: 3 •1 & • 1 !;- ORDER ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR HILL'S CENTURY FARM SUBDIVISION NO. 2 (FP -15-005) Page 3 of 3 EXHIBIT A STAFF REPORT MEETING DATE: March 3, 2015 TO: Mayor and City Council FROM: Sonya Watters, Associate City Planner 208-884-5533 Bruce Freckleton, Development Services Manager 208-887-2211 SUBJECT: FP -15-005 — Hill's Century Farm Subdivision No. 2 I. APPLICATION SUMMARY The applicant, Brighton Investments, LLC, has applied for a final plat (FP) consisting of 56 buildable lots and 9 common lots on 19.78 acres of land in an R-8 (medium density residential) zoning district. This is the second phase of development of Hill's Century Farm Subdivision. II. STAFF RECOMMENDATION Staff recommends approval of the Hill's Century Farm Subdivision No. 2 final plat based on the analysis provided below in Section V. III. PROPOSED MOTION Approval I move to approve File Number FP -15-005 as presented in the staff report for the hearing date of March 3, 2015, with the following modifications: (Add any proposed modifications.) Denial I move to deny File Number FP -15-005, as presented during the hearing on March 3, 2015, for the following reasons: (You should state specific reasons for denial.) Continuance I move to continue File Number FP -15-005 to the hearing date of (insert continued hearing date here) for the following reason(s): (You should state specific reason(s) for continuance.) IV. APPLICATION AND PROPERTY FACTS A. Site Address/Location: The subject property is generally located east of S. Eagle Road and south of E. Amity Road at 5340 S. Eagle Road, in a portion of the west 1/2 of Section 33, T. 3N., R. IE. B. Applicant: Brighton Investments, LLC 12601 W. Explorer Drive, Ste. 200 Boise, ID 83713 C. Owner: Same as applicant Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 1 EXHIBIT A D. Representative: Mike Wardle, Brighton Corporation 12601 W. Explorer Drive, Ste. 200 Boise, ID 83713 V. STAFF ANALYSIS The proposed final plat depicts 56 single-family residential building lots and 9 common lots on 19.78 acres of land in an R-8 zoning district. The gross density of the proposed subdivision is 2.8 dwelling units (d.u.) per acre with a net density of 4.6 d.u. per acre. The minimum property size is 7,200 square feet (s.f.) with an average size of 9,396 s.f. All of the lots proposed in this phase are for single-family detached homes and must comply with the dimensional standards of the R-8 zoning district listed in UDC Table 11-2A-6. Staff has reviewed the proposed plat and found it in compliance with the aforementioned dimensional standards. Staff has reviewed the proposed final plat for substantial compliance with the approved preliminary plat in accord with the requirements listed in UDC 11 -6B -3C.2. The number of buildable lots and common area is the same. Therefore, staff deems the proposed final plat in substantial compliance with the approved preliminary plat. VI. SITE SPECIFIC CONDITIONS Prior to City Engineer signature on the final plat, the applicant shall remove all existing structures on the site. 2. The applicant shall construct all proposed fencing and/or any fencing required by the UDC, consistent with the standards as set forth in UDC 11-3A-7 and 11 -3A -6B. 3. The rear or side of structures on Lots 15-24 and 26-28, Block 4, and Lot 33, Block 3 that face E. Taconic Drive and/or E. Highlander Drive, shall incorporate articulation through changes in materials, color, modulation, and architectural elements (horizontal and vertical) to break up monotonous wall planes and roof lines in accord with UDC 11-3A-19 and the Meridian Design Manual. 4. The final plat prepared by KM Engineering, stamped on December 16, 2014 by Aaron L. Ballard shall be revised as follows: a. Due to the potential for conflict of utility locations and required landscaping within the common lots under the current blanket easement scenario, the applicant shall define the locations of public utility, drainage and pressurized irrigation easements to ensure trees are located outside of these easement areas; modify note #5 accordingly, and show easement locations graphically on the plat. b. Note #11 shall be revised as follows: "Lots shall not be reduced in size without prior approval from the health authority and the City of Meridian." c. Note #14 shall be revised as follows: "Direct lot or parcel access to S. Eagle Road, E. Taconic Drive and E. Highlander Drive is prohibited." d. Note #15: Include lot and block number(s) e. Note #16: Include recorded instrument number. Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 2 EXHIBIT A 5. The landscape plan prepared by KM Engineering, dated January 28, 2015, shall be revised prior to signature on the final plat by the City Engineer as follows: a. Include a concrete pad at the end of the common drives on Lots 16, 18, 23, and 25, Block 3, no more than 5 feet behind the sidewalk that is of sufficient area to accommodate the receptacles of the residences that take access from the common driveway. Please contact Bob Olson at Republic Services (345-1265) for additional information. b. Where parkway trees are required and there is an ACHD storm drainage easement, trees must be placed on the adjacent lot outside of the easement by the developerlbuilder; a note shall be placed on the landscape plan and the tree calculations table modified accordingly. c. The 8 -foot wide pathway depicted along the north side of E. Taconic Drive should continue at that width along the north side of E. Highlander Drive for enhanced pedestrian access to the future elementary school and City park site at the northeast corner of the project; currently, it changes to 5 feet at the Taconic/Highlander intersection. d. Fencing abutting the common area on Lot 29 along the rear of Lots 22-24 and 26-28, Block 4 shall be reduced to 4 feet in height if closed vision material is used, in accord with UDC 11-3A-7A.7b. If this code requirement changes prior to construction of the fence, the applicant may submit a revised landscape plan in accord with the code requirements in effect at that time. e. Depict a 5 -foot wide landscape strip along the south side of Lots 17 and 24, Block 3, consistent with the common driveway exhibit, in accord with UDC 11 -6C -3D.5. 6. The common driveways proposed on Lots 17 and 24, Block 3 shall be paved with a surface capable of supporting fire vehicles and equipment, per UDC 11 -6C -3E.4. A street light plan needs to be included in the civil plans application. Street light plan requirements are listed in section 6-5 of the Improvement Standards for Street Lighting. A copy of the standards can be found at http://www.meridiancity.org/public_works.aspx?id=272. This plan will need to include Type 2 lighting on internal local streets in the subdivision, Type 1 lighting is currently called out on the Landscape Plan. Lighting spacing needs to be reviewed on Taconic Dr. and Highlander Dr. A midblock light should be included on Lachlan St. between Tavistock Ave. and Highlander Dr. to meet light spacing standards. A midblock light should also be included on Tavistock Ave. between La Grange St. and Lachlan St. to meet light spacing standards. Submit a copy of the final street name evaluation letter with the final plat for City Engineer signature. 8. Construction of common driveways shall comply with the standards listed in UDC 11 -6C -3D. 9. A perpetual ingress/egress easement shall be filed with the Ada County Recorder, which shall include a requirement for maintenance of a paved surface capable of supporting fire vehicles and equipment, per UDC 11 -6C -3E.8. A copy of said easement shall be submitted with the final plat for City Engineer signature. VII. ONGOING CONDITIONS OF APPROVAL The applicant and/or assigns shall have the continuing obligation to provide irrigation that meets the standards as set forth in UDC 11-313-6 and to install and maintain all landscaping as set forth in UDC 11-3B-5, UDC 11-3B-13 and UDC 11-313-14. 2. All common open space and site amenities shall be maintained by an owner's association as set forth in UDC 11 -3G -3F1. Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 3 EXHIBIT A 3. The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site (AZ -14-012; PP -14-04). 4. The applicant and/or property owner shall have an ongoing obligation to prune all trees to a minimum height of six feet above the ground or sidewalk surface to afford greater visibility of the area. 5. The applicant shall have an ongoing obligation to maintain all pathways. 6. The applicant has a continuing obligation to comply with the outdoor lighting provisions as set forth in UDC 11-3A-11. 7. The applicant and/or property owner shall have an ongoing obligation to maintain all landscaping and constructed features within the clear vision triangle consistent with the standards in UDC 11- 3A-3. 8. Future homes constructed within this development shall be generally consistent with the conceptual building elevations included in the development agreement. VIII. PROCESS CONDITIONS OF APPROVAL 1. No signs are approved with this application. Prior to installing any signs on the property, the applicant shall submit a sign permit application consistent with the standards in UDC Chapter 3 Article D and receive approval for such signs. 2. The applicant shall complete all improvements related to public life, safety, and health as set forth in UDC 11 -5C -3B. A surety agreement may be accepted for other improvements in accord with UDC 11 -5C -3C. 3. The applicant shall obtain approval for all successive phases of the preliminary plat within two years of the signature of the City Engineer on the previous final plat as set forth in UDC 11 -6B - 7B or obtain approval of a time extension as set forth in UDC 11-6B-7. 4. Upon installation of the landscaping and prior to inspection by Planning Division staff, the applicant shall provide a written certificate of completion as set forth in UDC 11 -3B -14A. 5. The applicant shall pay any applicable impact fees prior to the issuance of a building permit. IX. GENERAL REQUIREMENTS 1. Sanitary sewer service to this development is available via extension of existing mains adjacent to the development. The applicant shall install mains to and through this subdivision; applicant shall coordinate main size and routing with the Public Works Department, and execute standard forms of easements for any mains that are required to provide service. Minimum cover over sewer mains is three feet, if cover from top of pipe to sub -grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. 2. Water service to this site is available via extension of existing mains adjacent to the development. The applicant shall be responsible to install water mains to and through this development, coordinate main size and routing with Public Works. 3. Street signs are to be in place, sanitary sewer and water system shall be approved and activated, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District (ACRD) and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 4 EXHIBIT A 4. Upon installation of the landscaping and prior to inspection by Planning Department staff, the applicant shall provide a written certificate of completion as set forth in UDC 11 -3B -14A. 5. A letter of credit or cash surety in the amount of 110% will be required for all incomplete fencing, landscaping, amenities, pressurized irrigation, prior to signature on the final plat. 6. The City of Meridian requires that the owner post with the City a performance surety in the amount of 125% of the total construction cost for all incomplete sewer, water infrastructure prior to final plat signature. This surety will be verified by a line item cost estimate provided by the owner to the City. The applicant shall be required to enter into a Development Surety Agreement with the City of Meridian. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety, which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20% of the total construction cost for all completed sewer, and water infrastructure for a duration of two years. This surety amount will be verified by a line item final cost invoicing provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety, which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. 8. All development improvements, including but not limited to sewer, water, fencing, pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy, or as otherwise allowed by UDC 11-5C-1. 9. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to the issuance of a plan approval letter. 10. It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. 11. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 12. Developer shall coordinate mailbox locations with the Meridian Post Office. 13. All grading of the site shall be performed in conformance with MCC 11-12-3H. 14. Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 15. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3 -feet above the highest established peak groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1 -foot above. 16. The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACRD. The design engineer shall provide certification that the facilities have been installed in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. 17. At the completion of the project, the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 5 EXHIBIT A 18. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of way (include all water services and hydrants). The easement widths shall be 20 -feet wide for a single utility, or 30 -feet wide for two. The easements shall not be dedicated via the plat, but rather dedicated outside the plat process using the City of Meridian's standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement (on the form available from Public Works), a legal description prepared by an Idaho Licensed Professional Land Surveyor, which must include the area of the easement (marked EXHIBIT A) and an 81/2" x 11" map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. All easements must be submitted, reviewed, and approved prior to development plan approval. 19. Applicant shall be responsible for application and compliance with and NPDES permitting that may be required by the Environmental Protection Agency. 20. Any existing domestic well system within this project shall be removed from domestic service per City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Engineering Department at (208)898-5500 for inspections of disconnection of services. Wells may be used for non-domestic purposes such as landscape irrigation if approved by Idaho Department of Water Resources Contact Robert B. Whitney at (208)334-2190. 21. Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and inspections (208)375-5211. 22. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water (MCC 12-13-8.3). The applicant should be required to use any existing surface or well water for the primary source. If a surface or well source is not available, a single -point connection to the culinary water system shall be required. If a single -point connection is utilized, the developer will be responsible for the payment of assessments for the common areas prior to development plan approval. X. EXHIIBITS A. Vicinity Map B. Approved Preliminary Plat (dated: 11/7/14) C. Proposed Final Plat (dated: 1/21/15) D. Proposed Landscape Plan (dated: 1/28/15) E. Common Driveway Exhibit (dated: 2/17/15) Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 6 Exhibit A - Vicinity Map EXHIBIT A Site Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 7 EXHIBIT A Exhibit B - Approved Preliminary Plat (dated: 11/7/14) Jim �7 del !I lit; ; Fj 17 2 Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 8 EXHIBIT A Exhibit C — Proposed Final Plat (dated: 1/21/15) 29' 31; F. Amlly_ 33 33 Rtfad wNYE �FM NM 'tYT�m SV3 Wt CPac w t1x,�,sEd I� I ke, - ��Y Y EMro�'aF! —2E? I- X 1Mpl. nd Ill TRPI -11 f!f-09° o � „,rsY�.ir ffi .ti.Yrfx+r � ly a �' �+ RISIR.S R' C -. Ea2xt lw etrau' 91 v1F3 ��I ,esr�Yor1 wrll�'£� � !Yw' yq +¢Nxxs.•M iw.zruv E 1ad1hR 5t ��� •£� I Eem � 9¢ jllyM1 N w^nr; ss � kl E¢ue'- � Imp ! � •''*•c '�- �� 3 .l�xrt + MF]ril.'F Immo I� Ixim $ $ i 1l'r'e Y xl4Y*M>7 K IlmrwT v �P4t'Iat �1 IP ( 1 Film Shd�A'W1n P "'7 � BIILaRFi i t3 r �s LfR 41ephR.d 94ET f - REO!e61Fll FLIT s![T ] - faT[i. ORK4 /ro CYNx[ Mfs AEE iARI.Eb SKET 3 - CORMtG51E O Q 94 hQT � [ENIIi1GlE4 1Nd MINMnv;3 PLAT Of HILL'S CENTURY FARM SUBDIVISION PHASE 2 il]LFQ ILLWYIJY W 4 AM RTIMbF THE 5 1120F1 EH 1f4.5ECF1M 33. IBOIFD 9hERii9SE -MWM4iIP3 NWM, RANGE 1 EASE. Bs9'.M MER , i1AW Ef?' RB3'tk WANDS °ALB 136511' uNItlC CiV OF MiR@NW,. ADAOXWTl', IDAHO. � 9EE 5✓9' RF81x MRH PI#lIG clr IiVilfEti N5 'J¢B tMSY Y SEE' lRf>3f.1 MIIH PIAiIIC GP NYIxEo 718 1N 1%BT aiE tlst _ r '� • YFT69 � + eoa.far Hd]fK � _ EaWr � yy �Wx _ _ _ —e _ _ I- X 1Mpl. nd Ill TRPI -11 f!f-09° o � „,rsY�.ir ffi .ti.Yrfx+r � ly a �' �+ RISIR.S R' C -. Ea2xt lw etrau' 91 v1F3 ��I ,esr�Yor1 wrll�'£� � !Yw' yq +¢Nxxs.•M iw.zruv E 1ad1hR 5t ��� •£� I Eem � 9¢ jllyM1 N w^nr; ss � kl E¢ue'- � Imp ! � •''*•c '�- �� 3 .l�xrt + MF]ril.'F Immo I� Ixim $ $ i 1l'r'e Y xl4Y*M>7 K IlmrwT v �P4t'Iat �1 IP ( 1 Film Shd�A'W1n P "'7 � BIILaRFi i t3 r �s LfR 41ephR.d 94ET f - REO!e61Fll FLIT s![T ] - faT[i. ORK4 /ro CYNx[ Mfs AEE iARI.Eb SKET 3 - CORMtG51E O Q 94 hQT � [ENIIi1GlE4 1Nd MINMnv;3 IEGENIT A HKtiikm il]LFQ ILLWYIJY W 4 FIXW S/8' R& r .m 'uB 12b axJ� IBOIFD 9hERii9SE 0 i1AW Ef?' RB3'tk WANDS °ALB 136511' uNItlC N61EII 9NERMYd � 9EE 5✓9' RF81x MRH PI#lIG clr IiVilfEti 'J¢B tMSY Y SEE' lRf>3f.1 MIIH PIAiIIC GP NYIxEo 718 1N 1%BT xdE 1p48 >'C4R S IESE �E6E4f1 4NF3QV 71B 1N9F' & rubvuim Foxe 'lxmf+xs rmuxp mR sT� 8! Gcf fuirE. bJ5[!.v(el 1r MC FAT LAtlE — R. Y➢ CENTEAl11E '�������• 915alVA UK u�lENrn ■E. I¢cao a sue�ev w. Eem. Mums pr sns cRuvrc, Equw. u. I�oq P 54WF*' w. 49x. REKpRC4 OE AW KP+WO'. Gl'4, Ra REKaw a well* w. axe, REno� of am. soNN1r. wxA. M, eEG01q � SIIR[" Na, 1911, RIXO®6 OF JlY COJ'!EY_ UW6. RF P1A19 SVT WOE9 — FECEIAS OF JWe G:.Mt'. aY»0 Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 9 12 59 A HKtiikm UE5'EI�E`11 RRIGHTO11 CORPORATION ��ua�Nlo Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 9 EXHIBIT A Exhibit D —Proposed Landscape Plan (dated: 1/28/15) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J I MATCH LINE • SEE SKEET L2.0 - - - - - - MATCH ONE • SEE SHEET L1.0 N Al. 7, W 177 71 Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 10 EXHIBIT A Exhibit E - Common Driveway Exhibit (dated: 2/17/15) Hill's Century Farm Phase 2 Shared Driveway Exhibits February 17, 20715 r I_ 4' SIDE BUILDING J II BLOC}.' 3 EWIELOPE — �yP' BLOCK 3 I 25 SIOE 23 II 5' aG I I LS � I I T C 9 IC'I 24I]' TALEO, R5HAFE]1C7IVEWAY RIVENWAY FE4CE, BV LOT E55/EGRE5 ' fi Hl!ILr1ER FEW E b LUT 25 7UILOER r. LOT 17 IS A NON—gL�ILG46LE - - COMMON LUT WITH A - ; II BLANKEr INGRf �. Lor 2d IS A NDN—BUILDABLE EASEMENT IN FAVOR OF LOTS COMMON LOO N1TH A 15 ANP 15, BLOCK- BLANKET INGRESS/EGRESS jj EASEMENT IN FAVOR OF LOFTS • 23 AND 25, BLOCK 3 . N Lots 16-13, Block 3 Lots 23-25, Block 3 S•:ala: Y'—FSU Scale: --`><T Hill's Century Farm Subdivision No. 2 FP -15-005 PAGE 11 Sonya Watters From: Sent: To: Cc: Subject: 113 EXHIBIT B Mike Wardle <MWardle@brig htoncorp.com> Thursday, February 26, 2015 10:39 AM Jaycee Holman; Jacy Jones; Machelle Hill; Holly Binkley Sonya Watters; Bruce Freckleton; David Turnbull; Jon Wardle; tmokwa@kmengllp.com; kevin@kmengllp.com RE: Hill's Century Farm Sub. 2 FP -15-005 We have reviewed the Hill's Century Farm Subdivision No. 2 (FP -15-005) staff report, with its project analysis and recommended conditions of approval. We concur with those conditions and recommendations—noting the anticipated fencing code modification cited in Site -Specific Condition #5.d to reflect "actual" open space fencing practices in recent Brighton projects—and request City Council approval by "consent" at its March 3rd meeting. I will attend the meeting to respond to Council questions, if any. Michael Wardle Director of Planning Brighton Corporation 12601 W. Explorer, Suite 200 1 Boise, Idaho 83713 Dircct 208.287.0512 1 Cell 208.863.6150 From: Sonya Watters [mailto:swatters@meridiancity.org] Sent: Tuesday, February 24, 2015 4:45 PM To: Mike Wardle Cc: Bruce Freckleton; Holly Binkley; Jacy Jones; Jaycee Holman; Machelle Hill Subject: Hill's Century Farm Sub. 2 FP -15-005 Attached is the staff report for the proposed final plat for Hill's Century Farm Subdivision No. 2 (FP -15-005). This item is scheduled to be on the Council agenda on March 3rd. The public hearing will be held at City Hall, 33 E. Broadway Avenue, beginning at 6:00 pm. Please call or e-mail with any questions. Mike - Please submit a written response to the staff report to the City Clerk's office (jholman@meridiancity.or , mhiti@meridiancity.org, iionesGmeridiancity.or�) and myself (e-mail or fax) by 3:00 pm the Thursday prior to the hearing. If you are in agreement with the conditions of approval contained in the staff report and you submit a written response accordingly by Thursday at 3:00 pm, your item will be placed on the consent agenda; consent agenda items are passed in one motion by the Council at the beginning of the meeting. Norse: if you are in agreement with the staff report, it is still recommended you attend the meeting in the event the item is pulled off of the consent agenda. If you do not respond to the staff report by Thursday, or if you have concerns with the conditions of approval, your project will be placed on the regular agenda. Thanks, Sonya