HomeMy WebLinkAboutChesterfield Subdivision PPRECEIVEI;~ MAR 1 82004 'itv Of Meridian ~l;i%y Clerk Office l~VlE17~1~7? STAFF SUMMARY ~~~~ ~<; r 1•,~ OF ~~ `'''° ~° " PLANNING AND ZONING COMMISSION RECOMMENDATION TO CITY COUNCIL Project Name: Chesterfield Subdivision Case No(s).: P-03-046 CUP-03-070, AZ-03-037 Applicant: Centennial Development, LLC P&Z Commission Hearing Date: February 19, 2004 Recommendation: Approve with conditions. Summary of Public Hearing: • The applicant, Kevin Amar, testified in favor of the application. • Nine members of the public testified in opposition to the proposed subdivision, expressing concerns regarding the density of the proposed development and the potential for increased traffic on El Gato Road. Key Commission Additions/1VIodifications to Staff Recommendation: • The Commission made two additions to the conditions of approval for the CUP. A condition stating that the Right to Farm Act should be referenced on the plat was added. A second condition was added stating that buildings are limited to one story on Block 5, Lot 21 and Block 9, Lot 65 of the subdivision. Outstanding Issues for City Council • None BEFORE THE PLANNING AND ZONING COMMISSION IN THE MATTER OF THE ) Case No. PP-03-046 REQUEST FOR PRELIMINARY ) PLAT FOR Chesterfield Subdivision ) RECOMMENDATION TO CITY COUNCIL Centennial Development, LLC, ) Applicant ) RECOMMENDATION The Meridian Planning and Zoning Commission hereby recommends to the City Council of the City of Meridian that they approve the preliminary plat as requested by the applicant for the property described in the application, subject to the following: 1. The property is located east of North Black Cat Road and north of West Franklin Road. 2. The owner of record of the subject property is Centennial Development, LLC. 3. Applicant is Centennial Development, LLC. 4. The subject property is currently zoned RUT. The applicant is applying for R-8 zoning. The zoning district of I-L is defined within the City of Meridian Zoning and Development Ordinance, Section 11-7-2. 5. The Applicant requests Preliminary Plat approval for a Planned Development in a proposed R-8 zone. 6. The Meridian Planning and Zoning Commission recognizes that the proposed application is in compliance with the Meridian Comprehensive Plan. 7. The use proposed which is the subject of this will, in fact, constitute a conditional use as determined by City policy. The Planning and Zoning Commission recognized the concerns of neighbors concerned with the project, expressed in their letters. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 1 A. Adopt the Special Recommendations of the Planning and Zoning Commission as follows: 1. Add a condition #12 on page 9 stating that the Right to Farm Act shall be referenced on the plat. 2. Add a condition #13 on page 9 stating that on Block 5, Lot 21 and Block 9, Lot 65 buildings shall be limited to one story with a maximum peak height of 25.' B. Adopt the Recommendations of the Planning and Zoning and Engineering staff as follows: SITE SPECIFIC COMMENTS /PRELIMINARY PLAT 1. Water service to this site shall be via main line extensions from the existing mains adjacent to the property. The applicant shall be required to extend water mains to and through the proposed development, thereby making them available to the adjacent properties (including stub streets and El Gato Road.). Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. 2. Sanitary sewer service to this site will be via main line extensions to an existing temporary lift station within the Blackstone Subdivision. This lift station pumps to an existing gravity sewer main located in Black Cat Road, that then flows to the Ashford Greens lift station. The Blackstone lift station shall be upgraded or modified, at this developers expense, to the City of Meridian's standards and specifications. The applicant will be responsible to construct lateral sewer mains to and through this proposed development including and in coordination with the City's Black Cat Trunk Project. Subdivision designer to coordinate main sizing and muting with the Public Works Department. This development shall be subject to the Ashford Greens sewer latecomers fees. Black Cat trunk development fee of $1,500.00 per dwelling unit shall also be assessed against this development. Payment of the trunk development fees and latecomer fees are required prior to signature on the fmal plat map by the City Engineer. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. 3. The final plat for Chesterfield Subdivision will not be signed until the extension of Pine Street to Black Cat Road has been completed. 4. The applicant has not definitively indicated who will own and maintain the pressurized irrigation system within this development. If the pressurized irrigation system within this development is to remain a private Homeowners RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 2 Association system, complete plans and specifications shall be reviewed by the Public Works Department as part of the development plan review process. A draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. Applicant shall be required to utilize any existing surface or well water for the primary source. If a surface or well source is not available, asingle-point connection to the culinary water system s hall b e required. If a s Ingle-point c onnection i s u tilized, t he d eveloper shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 5. A detailed fencing plan shall be submitted upon application for the final plat. A solid fence shall be required around the perimeter of the subdivision unless the City agrees in writing that such a fence is not required. Fencing for the side yards of patio lots bordering Kaspell Street and all patio lots bordering commori areas shall be 4' in height and made of a semi-solid material. Fencing adjacert to the proposed park shall be 4' in height (to increase the visibility of the park) and depicted in the fencing plan. This shall be an on-going condition of approval. 6. Submit a detailed landscaping depicting the playground equipment to be added to the proposed parks and a detailed plan for the proposed storm drain ponds. 7. Add or revise the following preliminary plat notes: •Add a note to the face of the plat that restricts fencing adjacent to the pathways within the subdivision to being no greater than four feet in height if solid sight- obscuring material is used for fence construction. 8. Ten (10) copies of a revised plat shall be submitted to the City Clerk's Office at least ten days prior to the next public hearing for this plat. 9. The applicant has not indicated whether the project is to be phased. If this project is to be phased, revise the plat to indicate phase lines. 10. Place a note on the plat that references the FEMA flood plain boundary adjacent to the Ten Mile Creek. Note restrictions associated with the flood zone on the face of the preliminary plat 11. Please submit all updated groundwater/soils monitoring data to the Public Works Department for review. The preliminary geotechnical evaluation, as prepared by Geo Engineers, indicates that shallow groundwater may be a factor, particularly in the areas of Test pits #1 and #5, where groundwater is assumed to be at a depth on the order of 3-3 1/2 feet. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate or discharge within a period of time not to exceed 24 hours for all stones up to and including a 100-year storm event. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 3 (All azeas being counted toward the 10% open space amenity shall be free of "wet ponds" or other such nuisances.) Side slopes within drainage azeas shall not exceed 3:1. The project engineer should pay close attention to the results of field studies determining the groundwater, soil type & and chazacteristics during the design and construction phases. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established normal groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above groundwater. 12. Reference the Right to Farm Act on the plat. 13. Buildings on Block 5, Lot 21 and Block 9, Lot 65 shall be limited to one story with a maximum peak height of 25.' GENERAL COMMENTS 1. Please submit a copy of the Ada County Street Name Committee's approval letter for the subdivision name, and the lot and block numbering. Make any corrections necessary to conform. 2. Coordinate fire hydrant placement with the City of Meridian Public Works Department. 3. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, play equipment, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 4. All micro-paths within the proposed subdivision shall be designed in accordance with MCC 12-13-15 "Micropath Landscaping". 5. A detailed landscape plan, depicting changes made to the plat since the initial submittal of the project and in compliance with the landscape ordinance shall be submitted for the subdivision with the final plat application. 6. Sidewalks within the proposed subdivision shall be built in accordance with MCC 12-13-10-8. 7. 100-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. The street light, contractor shall obtain design and permit from the Public Works Deparhnent prior commencing RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 4 installations. 8. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owner's), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the meridian City Engineer prior to final plat signature. 9. Contact Meridian's Parks Department regarding the existing matures trees on the subject property. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. 10. Developer shall coordinate mailbox locations with the Meridian Post Office. 11. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape imgation. 12. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 13. Contact Sanitary Services Company regazding the location of trash receptacles in the subdivision. C. Adopt the Recommendations of the Meridian Fire Department as follows: One and two family dwellings will require afire-flow of 1,000 gallons per minute available for duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. International Fire Code Appendix D 2. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 3. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. a. Fire Hydrants shall have the 4 ''/z" outlet face the main street or parking lot aisle. b. The Fire hydrant shall not face a street which does not have addresses on it. c. Fire hydrant markers shall be provided per Public Works spec. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 5 d. Locations with fire hydrants shall have the curb painted red 10' to each side of the hydrant location. e. Fire Hydrants shall be placed on comers. f. Fire hydrants shall not have any vertical obstructions to outlets within 10'. 4. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have an approved turn around. 5. All entrance and internal roads shall have a turning radius of 28' inside and 48' outside. 6. Insure that all yet undeveloped pazcels are maintained free of combustible vegetation. 7. Operational fire hydrants and temporary or permanent street signs are required before combustible construction begins. 8. A minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. This shall be measured off of the center line of the street. 9. Building setbacks shall be per the Building Code for one and two story construction. 10. The roadways shall be built to Ada County Highway Standards and shall have a clear driving surface, available at all times, which is 20' wide. Streets with less than a 29' street width shall have no parking. Streets with less than 33' shall have parking only on one side. 11. Fire lanes and streets shall have a vertical cleazance of 13'6". This includes mature landscaping. 12. The proposed project lies outside the five-minute response zone goal. Achievement of this goal is subject to budgetary c onstraints and is intended to enhance the probability of a favorable outcome on a request for Basic Life Support. The budget constraints are typically defined as capital outlay for facilities that are located within 1.5 miles from a given, location and sufficient operational funds to staff the facilities. 13. The fire department requests that any future signalization installed as the result of the development of this project be a quipped w ith Opticom Sensors to a nsure a safe and efficient response by fire and emergency medical service vehicles. This cost of this installation is to be borne by the developer RECOMMENDATION TO CITY COLINCII, OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 6 D. Adopt the Recommendations of Central District Health Department as follows: 1. This proposal can be approved for central sewage & central water after written approval from appropriate entities is submitted. 2. The Applicant's central sewage and central water plans must be submitted to and approved by the Idaho Department of Health & Welfare, Division of Environmental Quality. 3. Run-off is not to create a mosquito breeding problem. 4. Stormwater shall be pretreated through a grassy swale prior to discharge to the subsurface to prevent impact to groundwater and surface water quality. 5. The Engineers and architects involved with the design of the subject project shall obtain c urrent b est m anagement p radices f or s tormwater d isposal a nd d esign a stormwater management system that prevents groundwater and surface water degradation. E. Adopt the recommendations of the Ada County Highway District as follows: Site Specific Conditions of Approval Provide sufficient right-of--way on Pine Street to complete a 36-foot street section with vertical curb, gutter and 5-foot concrete sidewalk within a total of 50-feet of right-of--way. Transition the location of the right-of--way to taper from a complete 36-foot street section at the west of the property to one half of a 36-foot street section with a minimum of 24-feet of pavement, vertical curb, gutter and 5-foot concrete sidewalk within a minimum of 40-feet of right-of-way at the east of the property. Stripe El Gato Street (Pine Avenue) to have two 12-foot travel lanes and two 6-foot bike lanes. 2. Constmct the internal roadways as 36-foot street sections with rolled curb, gutter and 5-foot concrete sidewalk within 50-feet ofright-of--way, as proposed. 3. Constmct Carisbrooke Avenue to intersect Pine Street (El Gato Street) approximately 810-feet east of the west property line, as proposed. 4. Construct Notel Creek Avenue to intersect Pine Street (El Gato Street) approximately 560-feet west of the east property line, as proposed. 5. Constmct a stub street (Kaspell Street) to the east property line approximately 100-feet north of the south property line, as proposed. Construct a temporary turnaround and install a sign at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED 1N THE FUTURE". 6. Constmct a stub street to the west property line approximately 135-feet south of the north property line, as proposed. Construct a temporary turnaround and install RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 7 a sign at the temrinus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". Construct a stub street to the west property line to serve the 5.3-acre site that is located directly to the west. Construct a temporary turnaround and install a sign at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". 8. Construct the two standard cul-de-sac turnazounds to provide a minimum fuming radius of 45-feet. 9. Construct the alternative turnaround to accommodate adequate turning area, drainage, maintenance considerations and the written approval of the emergency fire service for the area where the development is located. Minimum design standards shall be met for all non-standazd turnarounds. Submit a design of the turnaround for review and approval by District Development Division staff. 10. Construct center islands/medians within the public right-of--way of Meadowpine Street, Notel Creek Avenue and Carisbmoke Avenue, as proposed. Provide a minimum of a 21-foot street section on either side of any proposed center island/median and construct the island to be a minimum of 4-feet wide to total a minimum of a 100-squaze foot area. 11. Any proposed landscape islands/medians within the publicright-of--way dedicated by this plat aze required to be owned and maintained by a homeowners association. Notes of this will be required on the final plat. 12. Other than the access points that were specifically approved with this application, direct lot access to Pine Street is prohibited. This restriction will be required to be noted on the final plat. 13. .Chesterfield Subdivision's preliminary plat will be approved contingent upon the right-of--way within Castlebmok Subdivision #1 and Castlebrook Subdivision #2 being dedicated to the public and the roadways being constructed or a financial surety is in place for the construction of the roadways prior to the signature of the final plat for Chesterfield Subdivision. 14. Comply with all Standazd Conditions of Approval. Standard Conditions of Approval Any existing irrigation facilities shall be relocated outside of the right-of--way. 2. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 8 3. Replace any existing damaged curb, gutter and sidewalk and any that maybe damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 4. Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District's Utility Coordinator at 387-6258 (with file numbers) for details. 5. All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standazds and approved supplements, Construction Services procedures and all applicable ACHD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepaze and certify all improvement plans. 6. The applicant shall submit revised plans for staff approval, prior to issuance of building permit (or other required permits), which incorporates any required design changes. Construction, use and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval for occupancy. 8. Payment of applicable road impact fees aze required prior to building construction in accordance with Ordinance #198, also known as Ada County Highway District Road Impact Fee Ordinance. 9. It is the responsibility of the applicant to verify all existing utilities within the right-of--way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1- 800-342-1585) at least two full business days prior to breaking ground within ACHD right-of--way. The applicant shall contact ACHD Traffic Operations 387- 6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 10. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the applicant to obtain written confirmation of any change fibm the Ada County Highway District. 11. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest advises the Highway District of its intent to change the planned use of the subject property unless a RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03A46 Page 9 waiver/variance of said requirements or other legal relief is granted pursuant to the law in effect at the time the change in use is sought. F. Adopt the Recommendations of Nampa Meridian Irrigation District as follows: 1. Applicant shall apply for a land use change application prior to final platting. 2. All laterals and waste ways must be protected. 3. The District's Purdam Drain and Kennedy Lateral courses through this proposed project. This easement must be protected and any encroachment without a signed License Agreement and approved plan, before any construction is started, is unacceptable. 4. All municipal surface drainage must be retained on site. If any surface drainage leaves the site, the Nampa & Meridian Irrigation District must review drainage plans. 5. The Developer must comply with Idaho Code 31-3805. 6. NMID recommends that irrigation water be made available to all developments within the Nampa & Meridian Irrigation District. RECOL~IIvIENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR Chesterfield Subdivision PP-03-046 Page 10