Loading...
HomeMy WebLinkAboutMcLinder Subdivison No. 1 FP-14-010BEFORE THE MERIDIAN CITY COUNCIL IN THE MATTER OF THE REQUEST FOR FINAL PLAT CONSISTING OF 21 BUILDING LOTS & 2 COMMON LOTS ON 11.8 ACRES OF LAND IN THE R-15 ZONING DISTRICT FOR MCLINDER SUBDIVISION BY: TS DEVELOPMENT APPLICANT HEARING DATE: APRIL 15, 2014 CASE NO. FP -14-010 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council on April 15, 2014 for final plat approval pursuant to Unified Development Code (UDC) 11-6B-3 and the Council finding that the Administrative Review is complete by the Planning and Development Services divisions of the Community Development Department, to the Mayor and Council, and the Council having considered the requirements of the preliminary plat, the Council takes the following action: IT IS HEREBY ORDERED THAT: The Final Plat of "PLAT SHOWING MCLINDER SUBDIVISION, LOCATED IN A PORTION OF THE NW/40F SECTION 36, TAN., R.1W., B.M., CITY OF MERIDIAN, ADA COUNTY, IDAHO, 2014, HANDWRITTEN DATE: 02/20/14, CARL PORTER, PLS, SHEET 1 OF 4," is conditionally approved subject to those conditions of Staff as set forth in the staff report to the Mayor and ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR MCLINDER SUBDIVISION NO. 1 (FP -14-010) Page 1 of 3 City Council from the Planning and Development Services divisions of the Community Development Department dated April 15, 2014, a true and correct copy of which is attached hereto marked "Exhibit A" and by this reference incorporated herein, and the response letter from Lance Warnick, a true and correct copy of which is attached hereto marked "Exhibit B" and by this reference incorporated herein. 2. The final plat upon which there is contained the certification and signature of the City Cleric and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 2.1 The plat dimensions are approved by the City Engineer; and 2.2 The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash surety has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code § 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR MCLINDER SUBDIVISION NO. 1 (FP -14-010) Page 2 of 3 Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty- eight (28) days after the date of this decision and order, seek a judicial review pursuant to Idaho Code§ 67-52. { a By action of the City Council at its regular meeting held on thegday of rx, , 2014. By: ' Tammy de ,, p6rd Mayor, City of Meridian Attest: C i,y ot koo Jaycee,,/' City Clerk r Copy served upon the Applicant, Planning Department, Public Works Department, and City Attorney. By' Dated: ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR MCLINDER SUBDIVISION NO. 1 (FP -14-010) Page 3 of 3 STAFF REPORT MEETING DATE: April 15, 2014IDIAN"' TO: Mayor and City Council FROM: Sonya Watters, Associate City Planner 208-884-5533 Bruce Freckleton, Development Services Manager 208-887-2211 SUBJECT: FP-14-010 — McLinder Subdivision No. 1 I. APPLICATION SUMMARY The applicant, TS Development, has applied for final plat (FP) approval of 21 building lots and 2 common/other on 11.8 acres of land in the R-15 zoning district for the first phase of McLinder Subdivision. II. STAFF RE COMMENDATION/DECISION Staff recommends approval of the McLinder Subdivision No. 1 final plat subject to the conditions noted in Sections VI and VII below. These conditions shall be considered in full, unless expressly modified or deleted by motion of the City Council. III. PROPOSED MOTION Approval I move to approve File Number FP -14-010 as presented in the staff report for the hearing date of April 15, 2014, with the following modifications: (Add any proposed modifications.) Denial I move to deny File Number FP -14-010, as presented during the hearing on April 15, 2014, for the following reasons: (You should state specific reasons for denial.) Continuance I move to continue File Number FP -14-010 to the hearing date of (insert continued hearing date here) for the following reason(s): (You should state specific reason(s) for continuance.) IV. APPLICATION AND PROPERTY FACTS A. Site Address/Location: The site is located at 4650 N. Linder Road on the southeast corner of N. Linder Road and W. McMillan Road, in the NW 1/4 of Section 32, Township 4 North, Range 1 West. (Parcel No.'s SO436223401 & SO436223441). B. Applicant: Tom Bevan, TS Development 4202 N. Marcliff Avenue Boise, ID 83704 McLinder Sub FP -14-010 PAGE 1 C. Owners: Same as applicant D. Representative(s): Lance Warnick, Aspen Engineers 485 N. Main Street Kuna, Idaho 83634 Penelope Riley, Riley Planning Services, LLC P.O. Box 405 Boise, ID 83701 V. STAFF ANALYSIS The proposed final plat depicts 21 building lots and 2 common lots on 11.8 acres of land in an R-15 zoning district. A total of 21 four-plex structures containing a total of 84 dwelling units are proposed to be constructed on the site. Staff has reviewed the proposed final plat for substantial compliance with the approved preliminary plat (PP -13-022). Because the number of buildable lots and common area is the same, staff deems the final plat to be in substantial compliance with the approved preliminary plat as required by UDC 11- 6B -3C.2. Because there are no street buffers being platted with this phase of development, a landscape plan is not required with this phase. Internal landscaping will be reviewed with the Certificate of Zoning Compliance and Design Review applications. VI. SITE SPECIFIC CONDITIONS 1. Applicant shall meet all terms of the approved annexation and zoning (AZ -13-010), preliminary plat (PP -13-022), and conditional use permit (CUP -13-010) for this site. 2. The applicant shall obtain the City Engineer's signature on the final plat within two years of City Council approval of the preliminary plat (by November 26, 2015), in accord with UDC 11-6B-7. 3. Prior to submittal for the City Engineer's signature, have the Certificate of Owners and the accompanying acknowledgement signed and notarized. 4. The final plat prepared by Sawtooth Land Surveying, LLC, stamped on February 24, 2014 by Carl Porter, shall be revised as follows: a. Include the recorded instrument numbers for the CC&R's. b. Include a note stating ownership and maintenance responsibilities for the common area on Lot 14, Block 1 and Lot 1, Block 2. c. Include a note for a cross-access/ingress-egress easement benefitting all lots in the subdivision and the recorded instrument number of such easement noted on the plat. d. Include the recorded instrument number for the City of Meridian water and sewer easement noted on the plat. The easement itself shall be dedicated per General Note # 19. e. Revise the subdivision name as follows: "McLinder Subdivision No. 1" McLinder Sub FP -14-010 PAGE 2 f. The line type depicting the boundaries of the sewer and water easement appears to be the same as the line type depicting the building envelopes. Please revise the plat to separately distinguishing line types. 5. All fencing installed on the site shall comply with UDC 11-3A-6 and 11-3A-7. If permanent fencing does not exist at the subdivision boundary, temporary construction fencing to contain debris shall be installed around this phase prior to release of building permits for this subdivision. 6. Staff's failure to cite specific ordinance provisions or conditions from the preliminary plat does not relieve the Applicant of responsibility for compliance. 7. The existing structures on the site and the access serving the home on McMillan Road shall be removed prior to signature on the final plat by the City Engineer. 8. A minimum 5 -foot wide detached sidewalk is required to be constructed along W. McMillan Road in accord with UDC 11-3A-17. This sidewalk shall be installed with the fast phase of this development. 9. Prior to the issuance of any new building permit, the property shall be subdivided in accordance with the UDC. 10. Prior to submittal for building permits, Certificate of Zoning Compliance and Design Review approval is required to be obtained for each of the multi -family structures and the clubhouse. Development of the site shall substantially comply with the previously approved site plan and building elevations, the design standards listed in UDC 11-3A-19, the guidelines contained in the City of Meridian Design Manual, and the specific use standards for multi -family developments listed in UDC 11-4-3-27. VII. GENERAL REQUIREMENTS 1. Sanitary sewer service to this development is available via extension of existing mains adjacent to the development. The applicant shall install mains to and through this subdivision; applicant shall coordinate main size and routing with the Public Works Department, and execute standard forms of easements for any mains that are required to provide service. Minimum cover over sewer mains is three feet, if cover from top of pipe to sub -grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. 2. Water service to this site is available via extension of existing mains adjacent to the development. The applicant shall be responsible to install water mains to and through this development, coordinate main size and routing with Public Works. 3. Street signs are to be in place, sanitary sewer and water system shall be approved and activated, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District (ACHD) and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. 4. Upon installation of the landscaping and prior to inspection by Planning Department staff, the applicant shall provide a written certificate of completion as set forth in UDC 11-313-14A. 5. A letter of credit or cash surety in the amount of 110% will be required for all incomplete fencing, landscaping, amenities, pressurized irrigation, prior to signature on the final plat. 6. The City of Meridian requires that the owner post with the City a performance surety in the amount of 125% of the total construction cost for all incomplete sewer, water infrastructure prior to final plat signature. This surety will be verified by a line item cost estimate provided by the owner to the City. The applicant shall be required to enter into a Development Surety Agreement McLinder Sub FP -14-010 PAGE 3 with the City of Meridian. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Please contact Land Development Service for more information at 887- 2211. 7. The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20% of the total construction cost for all completed sewer, and water infrastructure for a duration of two years. This suety amount will be verified by a line item final cost invoicing provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Please contact Land Development Service for more information at 887-2211. 8. All development improvements, including but not limited to sewer, water, fencing, and pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy, or as otherwise allowed by UDC 11-5C-1. 9. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to the issuance of a plan approval letter. 10. It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. 11. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 12. Developer shall coordinate mailbox locations with the Meridian Post Office. 13. All grading of the site shall be performed in conformance with MCC 11-12-3H. 14. Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 15. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3 -feet above the highest established peak groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1 -foot above. 16. The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACRD. The design engineer shall provide certification that the facilities have been installed in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. 17. At the completion of the project, the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. 18. 100 Watt and 250 Watt, high-pressure sodium street lights shall be required on all public roadways per the City of Meridian hnprovement Standards for Street Lighting. All street lights shall be installed at developer's expense. Final design shall be submitted as part of the development plan set for approval, which must include the location of any existing street lights. Street lighting is required at intersections, corners, cul-de-sacs, and at a spacing that does not exceed that outlined in the Standards. The contractor's work and materials shall conform to the ISPWC and the City of Meridian Supplemental Specifications to the ISPWC. Contact the City of Meridian Transportation and Utility Coordinator at 898-5500 for information on the locations of existing street lighting. 19. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of way (include all water services and hydrants). The easement widths shall be 20 -feet wide for a single utility, or 30 -feet wide for two. The easements shall not be dedicated via the plat, but McLinder Sub FP -14-010 PAGE 4 rather dedicated outside the plat process using the City of Meridian's standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement (on the form available from Public Works), a legal description, which must include the area of the easement (marked EXHIBIT A) and an 81/2" x 11" map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. 20. Applicant shall be responsible for application and compliance with and NPDES permitting that may be required by the Environmental Protection Agency. 21. Any existing domestic well system within this project shall be removed from domestic service per City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Engineering Department at (208)898-5500 for inspections of disconnection of services. Wells may be used for non-domestic purposes such as landscape irrigation if approved by Idaho Department of Water Resources Contact Robert B. Whitney at (208)334-2190. 22. Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and inspections (208)375-5211. 23. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water (MCC 12-13-8.3). The applicant should be required to use any existing surface or well water for the primary source. If a surface or well source is not available, a single -point connection to the culinary water system shall be required. If a single -point connection is utilized, the developer will be responsible for the payment of assessments for the common areas prior to development plan approval. V. EXHIIBITS A. Vicinity Map B. Approved Preliminary Plat (dated: 11/1/13) C. Proposed Final Plat (stamped/dated: 2/5/14) McLinder Sub FP -14-010 PAGE 5 Exhibit A — Vicinity Map McLinder Sub FP -14-010 PAGE 6 Exhibit B — Approved Preliminary Plat (dated: 11/1/13) PRELIMINARY PLAT OF- McLINDER SUBDIVISION LOCATED IN A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SECTION 36, LAN, R,IW, BOISE MERIDIAN. CITY OF MERIDIAN, ADA COUNTY, IDAHO NOVFMBER 1, 2013 AW" IMP- 111 I{ IYP I / MVI-MMUMIM' t ¢v4 am mm„•vm M1sa�amn, ♦. �it�„�ra.,6Pmwa.suvr+vty 7 !_', �+ MfXW1i W�� W u s. z taa.�az¢�n �,mL^II�et£ii I�ri'LlifaG.OYRTR���� MOM r�M1'.iiios��v'�in wr`<tidd i'\Sf�.'maa2wa"O�i'r ��a {$@ PRELIMINARY PLAT OF- McLINDER SUBDIVISION LOCATED IN A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SECTION 36, LAN, R,IW, BOISE MERIDIAN. CITY OF MERIDIAN, ADA COUNTY, IDAHO NOVFMBER 1, 2013 AW" IMP- MVI-MMUMIM' t ¢v4 am mm„•vm M1sa�amn, ♦. �it�„�ra.,6Pmwa.suvr+vty 7 !_', �+ MfXW1i W�� W u s. z r�M1'.iiios��v'�in wr`<tidd i'\Sf�.'maa2wa"O�i'r ��a {$@ �MRk-rai �Z ti�� f8i'1' Y'g3 rcwr,:n ygy5 '� �j 3' ,nua�verw - roa �¢%a� WN eaa�u sn �n mvw] lRN C •✓.rw ra V,� r.�tBCin SrA�i=p"1 nw£ l !1w . u ILA, f,t'fiY Mr PP -1 McLinder Sub FP -14-010 PAGE 7 Exhibit C — Proposed Final Plat (dated: 2/5/14) MCLINDER SUBDIVISION NOTFS BOOK ___, PAGE---- scAac A OF A PORTION OF THE NW114 OF SECTION 36, T. 4 N., R. 1 W, B.M., CITY OF MERIDIAN, ADA COUNTY, IDAHO 1. Ahl KI-WYW, Vy � RAT &4AU CGWW4 TO THE APlAICA&Z Z=14d REGULArMS 0? EFTCCT AT TIC ME 2014 2. PER I.C. 31 -JAYS, � "I VF WMI, M NAVPA-.JVIVkI (ASMC1, ALL LOTS WTW RAS SYBNV3a4 ARE "LCT TO 1LA1PA-lA!rS1',fM A T ' R"AM" DS R`Z ASSSISSVENfA ANO W44 KC64V *ArFR FRW SM0 01TAX7. J. ALL FRCYtT NO FTAR LOT LWIS ARZ 04MMY X9014ATED AS RAM0 A ILIN' W11 -r 26125 Klu�mw P�­o OwNA, PA,A-ER" NA,4c, Ami A WPA kowAh ­40� V4 UCM,UAN RD. EASEVENT. NERE IS A,1 0 O' FOOT WOE PNLW VWYY AW AWO-11 ADOMT TO Al PUMIC &WT 01 WAYS WXSS ONOWSr 11 At kItEkIN fgStKIII'At 114RIU.S4 LN "S HAW A v'r A C, --- — --- CA, WE 4�) FOOT Kwr . M NMAC UMPIES� FRCfZR7Y &W;AW AND . SAT, r�i OW I � fA� Lot a VNE IARLE Y1S_g4A=__ I. _,aSgLr rM ire 1111� 111 -MI WIN.11 IZIMIX 11� Cq PAP& CUR�-. TABLE Y"MiAINIX TKREOF, violury HAS &M m AWJV-D Dy M ARR4A M,/ MM" VSIRC7. of- D�S SMACAS AA10 NOVSMAL STAMAWS PI UPS VWIV� SHALL &E W t W. oftf it, -TY 41 "FAVAIJ &�0U*O.Lwr COX 4, A PNTM C' AA17 S_�RVEW TO AND COMN nir ACILD STORY WATER NMIAGf SYSTTV_ NMI LOIS ARE E,�X&RFO BY IRAI CERMN VASTER VtOtIVAC PPI 5TMV WATER CRAWACC ��T R.C(AVEt) CH MAY AS IN M59. CRIOAL RKICNCS OF "A CCLANTY 4110 WCO&WRA MIMa'YTTINVOS tl .1 wal. 1. Rartw1m AS St r A :E tW UASIER fAaVMt UE I m�-. t I Ass I AT we. S "n-EVZTMVCSATVMVTrd'ACHD M1R9J#fr TO SECM0 TDRAI WATER MWAGE 4�214 EASEVD(T IS � RAC �ERATIW AIS) UkNRIVALIXE 2� OVO VAS SKIN WATER NAWAV_l Sn", 7. N1SNAIJ$, C"TC&Ct AAD RESM:004S FOR NS SLVPIV.4�4 ARE PfCNOF0 AS MT. ,I AA t'� 0. TKIt 0061LOPINE10 PFCC01,12f$ WMAV 22-4W C� rdE VAHV M'�F, "T TO FX40 ACT, 5 Nvo E- 8 tri !t9 r: WfC" STA?M. *NO ACRID.A.RRAL CP1RAV�WWGTCtA7U1AL rACUrY OR EXPAYSVi S�AaL r�l IV XCIY�Z A Nl�� VAir CRF N MWI-11t 'r �Afj DY r__ - - -- I AS Iq OR A000t IN- SLIP= CNAVgt�(. CYVIRS AFTER It HAS AM W OPCIANN rN W. V10 (t) CAZ IrAIZ 9191 nfE *rl7'AT;CN WAS NOT A j P�AW�— AT IW PVI:)r AMI . AS CAVsm XIE.. W fttOHYOrrF I TICS UICw, WALL 1101' APPLY W-,Vy A &V�OPE RES�, IS MW W Wl`RMV N UMIC,14Y CPrRAPCI CfA4Y AMMLTIRAI 0,ERAW4 AMAttLRAL rACV7Y OR C13) ci) LI 4A RI t!@) - D" JOLOCn1' REcr. X J LEGEND W) SIARDIMOU (or LAST SICROYA, tM ------------------ NEW FAS�V, CMTERUIVE - - - - - - - - - - RIC41' Ll" WAY rMiND VRASS CAP tlW"­�t T 1 ram AILALNIUN, CAP AMWENI J LWPIAMLD, , __j 1 8 M00 SA' REFIAR AS NOTED (2) 1 1 vi BLOCK 1: FCVM 1/7' RFOAR AS NOTTO r- 110 5,411 COMMELD SET 51V' REGAR/CAP BLOCK I A, f/9' RCRARICAl I r I L - - - - - J d _T7) f3F -I r --- TF,, A CALMATO PONT 14 1 1 �,qi AEMW LIA"01WATM 7P� LfJ lornuvw 1SJ f0 BLOCK 2 -7, 77-7:�"' 7 3— I cm IV. ANN TAYCOR ST. 41 S"m wjcw Al- 00< --Ci Ag PACE IONS LI3 <I K- , 05 PA� 11.UO EZE 5$?ZC7 P rOlP W714 szC. J4 'c, McLinder Sub FP -14-010 PAGE 8 ■ Soma Wafters From: Lance Warnick <lance@AspenEngineers.com> Sent: Thursday, April 10, 2014 S:02 PM To: Sonya Watters Subject: RE: McLinder Sub FP Staff Report for 4/15 CC Mtg Thank you. Sorry I was slow. Lance Warnick, P.E. Principal Engineer Aspen Engineers 485 W. Main St, Suite B . PO Box 205 A Kuna, Idaho 83634 Phone (208) 466-8181 ■ Cell (208) 989-4531 - lance@AspenEngineers.com From: Sonya Watters [maiito:swatters@meridiancity.org] Sent: Thursday, April 10, 2014 4:58 PM To: Machelle Hill; lance@AspenEngineers.com; Holly Binkley; Jacy Jones; Jaycee Holman Cc: Justin Lucas; Bruce Freckleton Subject: RE: McLinder Sub FP Staff Report for 4/15 CC Mtg ThanksH From: Machelle Hill Sent, Thursday, April 10, 2014 4:58 PM To: Sonya Watters; lanceaAspenEngineers.com; Holly Binkley; Jacy Jones; Jaycee Holman Cc: Justin Lucas; Bruce Freckleton Subject. RE: McLinder Sub FP Staff Report for 4/15 CC Mtg Yes, it will be on consent. From: Sonya Watters Sent: Thursday, April 10, 2014 4:50 PM To: lance@AspenEngineers.com,; Holly Binkley; Jacy Jones; Jaycee Holman; Machelle Hill Cc: Justin Lucas; Bruce Freckleton Subject., RE: McLinder Sub FP Staff Report for 4/15 CC Mtg I have revised the staff report as noted below. Clerk — Can we still get this on the consent agenda? thx From: Lance Warnick [maiito:lance@AspenEngineers.comj Sent: Thursday, April 10, 2014 3:23 PM To: Sonya Watters; Holly Binkley; Jacy Jones; Jaycee Holman; Machelle Hill Cc: Justin Lucas; Bruce Freckleton Subject: RE: McLinder Sub FP Staff Report for 4/15 CC Mtg Sonya, Here are our comments on the staff report: 1. In Section IV, the address; parcel numbers and legal description refer to a different property and are not correct. Otherwise, we are in agreement to the conditions outlined in the staff report. Thanks, Lance Warnick, P.E. Principal Engineer Aspen Engineers 485 W. Main St, Suite B • PO Box 205 ° Kuna, Idaho 83634 Phone (208) 466-8181 W Cell (208) 989-4531 A Iance@AspenEngineers.com From: Sonya Watters fmailto:swatters@meridiancity.org) Sent: Tuesday, April 08, 2014 2:48 PM To: Holly Binkley; Jacy tones; Jaycee Holman; Machelle Hill Cc: lance(a@AspenEngineers.com; rileyplanninsservicesCa@vahoo.com; Justin Lucas; Bruce Freckleton Subject: McLinder Sub FP Staff Report for 4/15 CC Mtg Attached is the staff report for the proposed final plat for McLinder Sub. (FP -14-010). This item is scheduled to be on the Council agenda on April 15th. The public hearing will be held at City Hall, 33 E. Broadway Avenue, beginning at 6:00 pm. Please call or e-mail with any questions. Lance/Penelope - Please submit a written response to the staff report to the City Clerk's office (jholmanCmeridiancity.or�, mhitt@meridiancity.org, ]9 ones@meridiancity.or) and myself (e mail or fax) by 3:00 pm the Thursday prior to the hearing. If you are in agreement with the conditions of approval contained in the staff report and you submit a written response accordingly by Thursday at 3:00 pm, your item will be placed on the consent agenda; consent agenda items are passed in one motion by the Council at the beginning of the meeting. Note: If you are in agreement with the staff report, it is still recommended you attend the meeting in the event the item is pulled off of the consent agenda. If you do not respond to the staff report by Thursday, or if you have concerns with the conditions of approval, your project will be placed on the regular agenda. Thanks, Sonya