Loading...
HomeMy WebLinkAboutStaff CommentsMAYOR Tammy de W eerd CITY COUNCII, MEMBERS Keith Bird William L.M Nary Shaun Wardle Charles M. RounhBa CITY OF C~Yr~i~n II IDAHO crrY HAi i (208) 888-4433 -Fax 887-4813 PUBLiC WORKS BUILDING DEPARTMENT (208) 887-2211-Fax 898-9551 LEGAL DEPARTMENT (208)466-9272 -FAX 466-0405 STAFF REPORT: Hearing Date: February 24, 2004 To: Mayor, City Council and Planning & Zoning Commission RECEIVE From: Sonya Allen, Planner I U R FEB r`'. ~ 2004 Bruce Freckleton, Senior Engineering Tech.- City Of Meridian Re: Quenzer Commons Subdivision No. 6 City Clerk Office • Request for Final Plat Approval of Twerny-eight (28) Single-family Residential Building Lots on 5.4 Acres in an R-8 Zone for Quenzer Commons No. 6, by Brighton Development, Inc. (File No. FP-04-010). We have reviewed the above-referenced submittal and offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & T OCATION The applicant, Brighton Development, Inc., has requested final plat approval of the sixth phase of Quenzer Commons Subdivision. This phase of the subdivision consists of 28 single-family residential building lots and is located west of N. Locust Grove Road, approximately 1/4 mile north of E. Ustick Road. The gross density of Phase No. 6 is approximately 5.2 dwelling units/acre. The net density is approximately 6.7 dwelling units/acre. A Conditional Use Permit for a Planned Development (File No. CUP-02-007) has been approved for this subdivision allowing a portion of the subdivision to be developed in a commercial manner. Phase six of the proposed subdivision includes only residential uses. The proposed final plat complies with the approved Preliminary Plat and the terms of the Conditional Use Permit. Staff recommends approval of the final plat for Quenzer Commons Subdivision No. 6 with the comments and conditions stated in this report. Mayor & City Council Hearing Date: February 24, 2004 Page 2 of 3 CONDTTIONS OF APPROVAL Applicant shall meet all terms of the approved Preliminary Plat (PP-02-007), Planned Development (CUP-02-007), and Development Agreement (Inst. No.102078396). 2. The pressurized irrigation system within this development is to be owned and maintained by the Home Owner's Association. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, asingle-point connection to the municipal water system shall be required. Plans and specifications for the irrigation system shall be reviewed by the Public Works Department as part of the development plan review process, and a draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Sanitary sewer service and municipal water to this site shall be via extensions from existing mains. Applicant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standazd forms of easements, for any mains that aze required to provide service. 4. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. 5. Revise the fencing plan to reflect cedar fencing instead of chain link, to match existing perimeter fencing along southern boundary. 6. Add or revise the following plat notes: (7.) Revise note: "Building setbacks and dimensional standards in this subdivision shall be in compliance with approved Title 11 and Title 12 of the Meridian Cif Code unless otherwise modified by Conditional Use Permit (CUP-02-007). See setback chart this sheet. (10.) Add Development Agreement Inst. No. 102078396. 7. Any existing domestic wells and/or septic systems within this project shall be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 8. One Hundred watt (100w), high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed FP-04-010 Queuzer Commons Sub6 FP.doc Mayor & City Council Hearing Date: February 24, 2004 Page 3 of 3 at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. Street light contractor to obtain design and permit from the Public Works Department prior commencing installations. 9. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 10. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations aze set a minimum of three feet above the highest established normal groundwater elevation. 11. Coordinate fire hydrant placement with the City of Meridian's Water Deputy Fire Chief and the Public Works Department. 12. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate or dischazge within a period of time not to exceed 24 hours for all storms up to and including a 100-yeaz storm event. (All areas being counted towazd the 10% open space amenity shall be free of `vet ponds" or other such nuisances.) 13. Graphically depict an easement line 12-feet in width along the south boundary of the subdiviosion, and along the west side of Lot 17, Block 4. This extra width is necessary due to the placement of a pressurized irrigation mainline. 14. Correct the distance discrepancy, along Lots 5-9, Block 25, between the legal description of the Certificate of Owner's and the face of the plat. 15. Revise the bearing across the west end of E. Legacy View Drive to a "IVE" bearing. 16. Add the missing distance dimensions to Lot 9, Block 25, and Lot 1, Block 26, and add the missing bearing down the middle of Block 26. 17. Correct the distance discrepancy of the side lot lines of Lots 6-1Q Block 26, and Lots 7- 11, Block 4. 18. Provide sidewalks in accordance with City Ordinance Section 12-13-10-8. 19. Staff s failure to cite specific ordinance provisions or terms of the approved preliminary plat, conditional use permit or development agreement does not relieve Applicant of responsibility for compliance. RECOMMENDATION Staff recommends approval of the final plat, with the above stated comments and conditions. FP-04-010 Quenzer Commons Sub6 FP.doc