Loading...
HomeMy WebLinkAboutParamount Sub No. 3 FP 03-070RECEIVEII~ City Of Meridian City Clerk Office WHITE PETERSON FEB 0 3 2004 WHITE, PETERSON, MORROW, GIGRAY, ROSSMAN, NYE & ROSSMAN, P.A. KEVIN E. Dwnrs PHare A. PEfER50N /ucIE ICEEw FISCxER TODDA. ROSEMAN WM. F. GIGRAY. IIf TFARA'CE R. WHITE*~ T. GUV H,uu.H* NICNOLA$L. WOLLEH Ia1 HOLwKA WILLIAM A. MoRROw W ALUM F. NlcxoLS* CHRISTOPHER S. NYE ATTORNEYS AT LAW NAMPA OFFICE 5700 E. FRANKLIN RD.. SlmE200 NAMPA, IDAHO 83687-8402 TEL. (208)466-9272 FAX (208) 466-4405 *Also admitted N OR ** Also admitted N WA William G. Berg, Jr. City Clerk 33 East Idaho Street Meridian, Idaho 83642 February 3, 2004 Re: PARAMOUNT DEVELOPMENT CO., LLC /PARAMOUNT SUBDIVISION N0.3 /FINAL PLAT - (FP-03-070) Dear Will: Regarding the above referenced matter, please find enclosed the original of the ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT for approval and signature by the Mayor and yourself. Please serve a copy of the ORDER upon the Applicant, with a Certificate of Service in the file and a copy to Planning and Zoning and Public Works, and the attorney's office. If you have any questions, please give me a call. Very truly yours, Wm. F. Nichols Z:\Work'dvl\MeridiaoQvleridian 15360M\Paramount Sub No. 3 FP-03-070\ClerkFPltr 02 03 04.dcc BEFORE THE MERIDIAN CITY COUNCIL C/C 01/20/04 IN THE MATTER OF THE APPLICATION OF PARAMOUNT DEVELOPMENT CO., LLC FOR APPROVAL OF 42 SINGLE FAMILY RESIDENTIAL BUILDING LOTS AND 3 COMMON LOTS ON 15.41 ACRES IN AN R-8 ZONE FOR PARAMOUNT SUBDIVISION N0.3, LOCATED EAST OF NORTH CINDER ROAD AND NORTH OF WEST McMILLAN ROAD, MERH)IAN, IDAHO CASE NO. FP-03-070 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council for Final Plat approval pursuant to Meridian City Code § 12-3-7 on January 20, 2004, and the Council finding that the Administrative Review is complete from Sonya Allen for the Planning and Zoning Department, and Bruce Freckleton, Engineering Technician III, dated: Hearing Date: January 20, 2004, to the Mayor and Council, and that Brad Hawkins-Clark Associate Planner for the Planning and Zoning Department, commented at the hearing, and the Council having considered the requirements of the preliminary plat the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Final Plat of "PLAT SHOWING PARAMOUNT SUBDIVISION NO. 3, LOCATED IN A PORTION OF SECTION 25, T.4N., R.1 W., B.M., MERIDIAN, ADA ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT ! (FP-03-070) Page 1 of 5 COUNTY, IDAHO 2004, ENGINEERING NORTHWEST, LLC, BOISE, IDAHO, 03-028-00, SHEET 1 OF 3, HANDWRITTEN DATE: 12-9-2003, STAMPED DATE: DEC 19 2003, J:\PARAMOUNT_SUB3_03028\Drawings\00_PARAM3 PLATl.dwg 12/9/2003", Paramount Development Co., LLC, Developer, is Conditionally Approved subject to those conditions of Staff comments as set forth in the Memorandum to the Mayor and City Council from Bruce Freckleton, Engineering Technician III, and Sonya Allen for the Planning and Zoning Department, dated: Hearing Date: January 2Q 2004, listing 12 SITE SPECIFIC COMMENTS / FINAL PLAT and 7 GENERAL REQUIREMENTS, a true and correct copy of which is attached hereto marked Exhibit "A", and consisting of four pages, and by this reference incorporated herein, and the additional requirements from the action of the Council taken at their January 20, 2004 meeting as follows, to-wit: 1.1 Comply with the conditions of the Meridian Fire Department as follows: The following will be the requirements and/or concerns to provide minimum levels of fire protection for the proposed project: 1. That project which comprised of single family dwellings will require afire-flow of 1,000 gallons per minute available for duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. 2. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 3. Final approval of the fire hydrant locations shall be by the Meridian Fire Department. The proposed fire hydrants locations will be submitted to the Public Works for plan review. The area in front of the fire hydrants will be painted red 10' to each side of the fire hydrant. ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT / (FP-03-070) Page 2 of 5 4. All roads and fire lanes shall have a fuming radius of 28' inside and 48' outside. 5. Operafional fire hydrants and temporary or permanent street signs aze required before combustible construction begins. 1.2 Adopt the Recommendations of the Central District Health Department as follows: The Central District Health Department requires after written approval from the appropriate entities are submitted, they can approve this proposal for central sewage and central water; that plans must be submitted to and approved by the Idaho Deparment of Health and Welfaze, Division of Environmental Quality for central sewage and central water; that run-off is not to create a mosquito breeding problem; and it is suggested that stormwater be pretreated through a grassy swale prior to discharge to the subsurface to prevent impact to groundwater and surface water quality; that engineers and architects should obtain current best management practices for stormwater disposal and design a stormwater management system that is preventing groundwater and surface water degradation. Manuals for guidance: 1. State of Idaho Catalog Of Stormwater Best Management Practices For Idaho Cities And Counties. Prepared by the Idaho Division Of Environmental Quality, July 1997. 2. Stormwater Best Management Practices Guidebook. Prepared by City of Boise Public Works Department, May 2000. 2. The final plat upon which there is contained the Certificafion and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: The Plat dimensions are approved by the City Engineer; and 2. The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash has been issued ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT / (FP-03-070) Page 3 of 5 guazanteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for judicial Review maybe filed. Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which maybe adversely affected by this decision may, withintwenty- eight (28) days after the date of this decision and order, seek a judicial review as provided by Chapter 52, Title 67, Idaho Code. By action of the City Council at its regular meeting held on the 2~~ day of C~ ~"'''~a^- ~ , 2004. Y~ Tammy eerd Mayor, ity of Meridian ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT / (FP-03-070) Page 4 of 5 Attest: ``\``\` ~yaOF u n u4,,. ~~~/'i S~AI, - William G. Berg, Jr, Ci y Clerk - 9 ~~ '. Copy served upon Applicant, the PlaniYl~ayg f , j ~~g`Department, Public Works and City Attorney. ~, By~.~-.=,~ ~. Dated: 2 ~ ~~~ Z:\Work\MVNeadian\Meridian 15360M~Paiamount Sub No. 3 FP-03-070\Ott1erFP.doc ;~`~~ OF ~''% \~oRPOI~gT~ 9ti y~ ~<7 1 ~~~ UST 1St . Q.jQ~~~~ ,,((~~ ~~ ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT / (FP-03-070) Page 5 of 5 MAYOR Tammy de Weerd CITY COUNCIL MEMBERS Keith Bird William L.M. Nary Shaun Wardle Charles M. Rounhae ~~ ~ crrv or ~~~ ~. /VI P~'1G,~IGF,~1 14 IDAHO LEGAL DEPARTMENT (208) 466-9272 Fax 466-4405 PUBLIC WORKS BUILDING DEPARTMENT (208) 887-2211 ~ Fax 887-1297 PLANNING AND ZONING DEPARTMENT (208) 884-5533 ~ FAX 888-6854 STAFF REPORT: Hearing Date: January 20, 2004 To: Mayor, City Council and Planning & Zoning Commission 4'R From: Sonya Allen, Assistant City Planner ~~ Bruce Freckleton, Senior Engineering Tech Re: Paramount Subdivision No. 3 • Final Plat approval of Forty-two (42) Single-Family Residential Building Lots and Three (3) Common Lots on 15.41 Acres in an R-8 (P.D.) Zone, by Paramount Development Company, LLC (File No. FP-03-070). We have reviewed the above referenced submittals and offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY The applicant, Paramount Development Company, LLC, has applied for Final Plat approval of 42 single-family residential building lots and 3 common lots on 15.41 acres of land for Paramount Subdivision No. 3. The zoning designation for the proposed subdivision is R-8 (Medium Density Residential). This phase of the subdivision will have a gross density of .36 d.u./acre and a net density of .26 d.u./acre. The common area lots within the subdivision consist of landscape/open space lots. The pressurized irrigation system within this development is to be owned and maintained by the Paramount Homeowners Association. A Conditional Use Permit (Planned Development) was approved for this subdivision that allowed for a reduction in the minimum lot size from 6,500 s.f. to 5,500 s.f.; front setbacks reduced from 15' for living areas to 10'; street side setbacks reduced from 20' to 10'; and a reduction in street frontage from 65' to 50'. The submitted final plat is in compliance with the approved preliminary plat. EXHIBIT "A" PAGE 1 OF 4 Mayor & City Council Hearing Date: January 20, 2004 Page 2 Staff recommends approval of the final plat for Paramount Subdivision No. 3 with the comments and conditions stated in this report. LOCATION This phase of Paramount Subdivision is located approximately '/z mile east of N. Linder Road and '/: mile south of W. Chinden Blvd. in the center of Section 25, T.4N., R.1 W. SURROUNDING PROPERTIES Phase III is surrounded on all sides by other phases of Pazamount Subdivision. The parcels of land outside the boundaries of the proposed subdivision are rural residential/agricultural properties, zoned RUT (Ada County). SITE SPECIFIC COMMENTS /FINAL PLAT 1. Applicant is to meet all terms of the approved preliminary plat (PP-03-004), conditional use permit (CUP-03-008) and Development Agreement (Inst. No. 103 1371 1 6). 2. The applicant has indicated that the Paramount Homeowners Association will own and maintain the pressure irrigation system within this development. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, asingle-point connection to the culinary water system shall be required. Plans and specifications for the irrigation system shall be reviewed by the Public Works Department as part of the development plan review process, and a draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Fencing adjacent to pathways and internal open space/drainage lots is to be no more than 4' in height if solid material is used, with the allowance of a 2' lattice to be placed on top of the solid fence. Temporary construction fencing to contain debris shall be installed along the boundaries of this phase unless fencing already exists at the subdivision boundaries. 4. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvements, including perimeter fencing, EXHIBIT "A" PAGE 2 OF 4 Mayor & City Council Hearing Date: January 20, 2004 Page 3 irrigation, and landscaping shall be installed and approved prior to obtaining certificates of occupancy. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, amenities, sanitary sewer, water, etc., prior to signature on the final plat. 5. Sanitary sewer service and municipal water to this site shall be via extensions from existing mains. Applicant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. 6. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. Revise or add the following notes to the face of the plat: (8.) Revise note to read: "Buildine setbacks and dimensional standards in this subdivision shall be in compliance with Conditional Use Permit (CUP-03-008) which allowed for reduced setbacks, lot sizes and lot frontages " (11.) Delete note pertaining to min. house size (no longer required on plat). (15.) Add Development Agreement Instrument No. 103 1 3 71 1 6. 8. Developer shall coordinate mailbox locations with the Meridian Post Office. 9. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate or discharge within a period of time not to exceed 24 hours for all storms up to and including a 100-year storm event. (All areas being counted toward the 10% open space amenity shall be free of "wet ponds" or other such nuisances.) 10. Increase the width of the Public Utilities, Drainage and Irrigation Easements to (8') eight-feet across the northeasterly side of Lot 1, Block 18, Lot 1, Block 17, and Lot 1, Block 15, and the south westerly side of Lot 1, Block 14. These areas all have pressurized irrigation transmission mains within them. 11. Graphically depict (5') five-foot wide Public Utilities, Drainage and Irrigation Easements along the lots bordering the southeast subdivision boundary. These are side lot lines against future phases. 12. Staff s failure to cite specific ordinance provisions or terms of the approved preliminary plat or conditional use permit does not relieve the Applicant. of responsibility for EXHIBIT "A" PAGE 3 OF 4 Mayor & City Council Hearing Date: January 20, 2004 Page 4 compliance. GENERAL REQUIREMENTS 1. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the meridian City Engineer prior to final plat signature 2. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. One-hundred-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and permit from the Public Works Department prior commencing installations. 4. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 5 Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 6. Coordinate fire hydrant placement with the City of Meridian's Water Works Superintendent. 7. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. STAFF RECOMMENDATION Staff recommends approval of the final plat for Paramount Subdivision No. 3 with the above stated comments and conditions. EXHIBIT °`A" PAGE 4 OF 4