HomeMy WebLinkAboutAshford Green Subdivision No. 6 FP-01-025BEFORE THE MERIDIAN CITY COUNCIL
C/C 01/15/02
IN THE MATTER OF THE
APPLICATION OF BRIGHTON
CORPORATION, FOR
APPROVAL OF FINAL PLAT
FOR ASHFORD GREENS NO. 6
SUBDIVISION, LOCATED EAST
OF BLACK CAT ROAD AND
NORTH OF CHERRY LANE,
MERIDIAN, IDAHO
CASE NO. FP-Ol-025
oRDER OF CONDITIONAL
APPROVAL OF FINAL PLAT
This matter coming before the City Council for Final Plat approval
pursuant to Meridian City Code § 12-3-7 on January 15, 2002, and the Council
finding that the Administrative Keview is complete which has included certain
comments and conditions as stated in a letter to the Mayor and Council from Shari
Stiles, Planning and Zoning Administrator, and Bruce Frecldeton, Engineering
Technician III, for the Public Works Department, listing 6 General Requirements
and 17 Site Specific Comments, which are herein found fair and reasonable, and at
the January 15, 2002 meeting, Shari Stiles, Planning and Zoning Administrator and
John Wardle, appeared and testified at the hearing, and no one appeared in
ORDER OF CONDITIONAL APPROVAL OF FINAL
PLAT FOR ASHFORD GREENS NO. 6 SUBDIVISION (FP-01-025)
-1
opposition, and the Council having considered the requirements of the preliminary,
plat the Council takes the following action:
IT IS HEREBY ORDERED THAT:
1. The Plat of "ASHFORD GREENS NO. 6" as evidenced in Plat bearing
the "PLAT SHOWING ASHFORD GREENS NO. 6, A SUBDIVISION LOCATED
IN THE SW V4 OF SECTION 3, T.3N., R. 1W., B.M., MERIDIAN, ADA COUNTY,
IDAHO, 2001, HUBBLE ENGINEERING, INC., MERIDIAN, IDAHO,, SHEET 1
OF 2, [: \PRO[ECTSkASHFORD~DRAWINGSk&SHFORD6\ashford6platREV.dwg,
MON OCT 15 2001, BOB UNGER, DEVELOPER: BRIGHTON CORPORATION,
BOISE, IDAHO, 00-099-02," and BRIGHTON CORPORATION, is Conditionally
Approved subject to those conditions of Staff comments as set forth in the
Memorandum to the Mayor and City Council from Shari Stiles, Planning and Zoning
Administrator and Bruce Frecldeton, Engineering Technician III, of the Public Works
Department, dated January 9, 2002, listing 6 General Requirements and 17 Site
Specific Comments, a true and correct copies are attached hereto marked Exhibit "A",
and consisting of four pages, and by this reference incorporated herein, with the
additional requirements as follows, to-wit:
1.1 Deputy Fire Chief, Joseph Silva, requires that a fire-flow of 1,000
gallons per minute shall be available to service the entire project.
ORDER OF CONDITIONAL APPROVAL OF FINAL
PLAT FOR ASHFORD GREENS NO. 6 SUBDIVISION (FP-01-025)
-2
Fire hydrants shall be placed an average of 500' apart. 1997 UFC
Appendix III.A.
1.2
Operational fire hydrants and temporary or permanent street
signs are required before combustible construction begins. UFC
901.4.2 &901.3.
1.3
Acceptance of the water supply for fire protection shall be
contingent upon acceptance of the water system by the City of
Meridian for water quality.
1.4
Fire approval of fire hydrant locations shall be by the Meridian
Fire Department.
1.5 All radii shall be 28' inside and 48' outside radius.
1.6
Insure all yet undeveloped parcels are maintained free of
combustible vegetation per section 1103.2.4 of the UFC.
1.7
The Central District Health Department's requirements shall be
complied with as addressed in the District's Environmental
Health Division letter dated December 26, 2001.
1.8
The Nampa & Meridian Irrigation District requires that any
encroachments within the easement of the Safford Lateral shall
be approved with a License Agreement. The plat does not
indicate the Safford Lateral that courses along the south
boundary of the pro}ect. An addendum to the existing contract
shall be required.
Additionally, the applicant shall comply with the requirements of the action of the
City Council taken at their January 15, 2002 meeting as follows:
1.9
Applicant shall clarify Site Specific Comment number 13,
pertaining to the well, and per the January 15, 2002 Council
meeting shall supply a new revised Construction Drawing
showing the correct well location outside of the right-of-way, and
ORDER OF CONDITIONAL APPROVAL OF FINAL
PLAT FORASHFORD GREENS NO. 6 SUBDIVISION (FP-01-025)
-3
said Construction Drawing shall be approved by the Public
Works Department and Planning and Zoning.
2. The final plat upon which there is contained the Certification and signature of
the City Clerk and the City Engineer verifying that the plat meets the City's
requirements shall be signed only at such time as:
2.1 The Plat dimensions are approved by the City Engineer; and
2.2 The City Engineer has verified that all off-site improve~nents are
completed and/or the appropriate letter of credit or cash has been
issued guaranteeing the completion of off-site and required on-
site improvements.
By action of the City Council at its regular meeting held on the /~--J~'~' day
of , oo2.
~~ CORRIE
Copy served upon Applicant, the Planning and Zoning Department and the~ }*,,Public
Works Department.
'"(~it'y Clerk '
Dated:
Z:\W o r k~Vi~MeridiankMeridian 15360~hford Gms #6 FPO 1-025~FPOrder01.025.doc
ORDER OF CONDITIONAL APPROVAL OF FINAL
PLAT FOR ASHFORD GREENS NO. 6 SUBDIVISION (FP-01-025)
-4
HUB ()F TRF_.4SURE VALLgY
A Good Place to Live
CITY OF MERIDIAN
~ EAST IDAHO
MERIDIAN, IDAHO 83642
(208) 888-4433 · FAX (208) 887-4813
City Clark Office Fan (208) 888-421 g
LEGAL DEPARTMENT
(208) 288-2499 · Fax 288-2501
pLr~LIC WORK8
BUILDING DEPAP. TMENT
(208) 887-2211 · Fax 887-1297
PLANNINO AND ZONING
DEPARTMENT
(208) 884-5533 · FAX 888-6854
MEMORANDUM:
To:
From:
Re:
Mayor & City Council
Bruce Freckleton, Assistant to City Englne~
Shad Stiles, Pl~oi.g & Zoning Administrator
January 9, 2002
RECEIVED
JAN l U 2002
City Of Merid/a~
Ci~y- Clerk Office
Request for a Final Plat Approval of Aslfford Greens No. 6 Subdivision - 23 Single-
Family Lots and 4 Other Lots on 9.24 Acres in an R-4 Zone by Brighton Corporation
(File # FP-Ol=025)
We have reviewed this submittal and offer the following comments, as conditions of the
applicant. These conditions shall be considered in full, unless expressly modified or deleted by
motion of the Meridian City Council:
APPLICATION SUMMARY
The application is for 23 single-family building lots on 9.24 acres of land in an R-4 zone, at a gross
density of 3.42 units per acre. The applicant is not responsible for the filing of the Eight-Mile Lateral,
however a variance for the piping of Satford Lateral was applied for by the applicant in 1995. the
Council took no action at that time and tabled the variance request indefinitely. A variance has been
issued to the Golf View Subdivision (directly north of Ashford Greens) to eliminate the requirement to
tile the Safford Lateral.
LOCATION
The subject property is located approximately one-quarter mile west of Black Cat Road, approximately
one-quarter mile north of Cherry Lane. The parcel is currently/oned R-4.
SURROUNDING USES
North- Cherry Lane GoffCourse, zoned R-4 (Quasi-Public Uso).
South- Stafford Lateral and Golf View Estates, zoned R-4.
East- Brenda Estates, zoned R-4. '
West- Ashford Green #5, zoned R-4.
SITE SPECII~IC COMMENTS
Applicant is to meet all terms of the approved preliminary pht.
Street signs are to be in place, water system shall be. approved and activated, pressurized
irrigation system approved and activated, fencing installed, and road base approved by the Ada
County Highway District prior to applying for building permits. Landscaping shall be installed
Aahfo~C~eea~.~
_~3~dnd Council
Sanuary 9, 2002
Page 2
prior to obtaining certifieafes of occupancy. A letter of credit or cash surety in the amount of
110% will be required for ali fencing, landscaping, pressurized irrigation, sanitary sewer, water,
etc., prior to signature on the final plat.
Applicant shall be responsible to construct permanent perimeter fencing, except where the City
has expressly agreed, n wntang, that such fencing is not necessary. Fencing is to be in place
prior to applying for building permits.
4. Revise and/or modify the following notes:
2) ...have a ~ ~ foot wide permanent public utilities, street light, drainage,
si e_._~l.~E~end irrigation easement.
3) ...and drainage easement, unless otherwise shown.
4) Delete this note. The sidewall~ although separated, must be a public pedestrian
walkway, not an exclusive walkway for homeowners within the subdivision~
5) Add lot and block manber for the common lot/landscape island located in the center of
IV.Dawson Drive.
7) ...above the highest ..... ~ estabhshed normal groundwater elevatmn.
10) ... 1400 square feet of living spaee, a~
Landscaping shall be installed per the approved landscape plans (dated 12-4-02). Landscaping
shall be complete prior to obtaining certificates of occupancy.
Sanitary sewer and water service to this site will be via extensions of the existing mains
installed in adjacent phases of this development. Applicant will be responsible to construct
lateral sewer and water mains to and through this proposed development. Subdivision designer
to eoordinote main sizing and routing with the Public Works Department.
Applicant's engineer will be required to submit a signed, stamped statement certifying that all
street finish centerline elevations are set a minimum of three feet above the highest established
normal groundwater elevatiofi. This ce~ffication will be 'required prior to approval of the
development plans. '
Provide a copy of the ex. ecutad encroachment agreement (if any) with Nampa-Meridian
Irrigation District, indicating how the 'land underlying the Safford Lateral easement may be
used, prior to si~ature on the final plat. The non-encroachable area of the Safford Lateral
easement will need to be removed fi.om the building lots and contained within a common lot to
be owned and maintained by the Ashford Greens Homeowners Association. The rear lot line
may be set at the edge of tim encroachable area if an agreomemt has been executed.
Assuming the variance is granted for tiling, pennanant fencing shall be constmcted on the
northerly easement line of the Safford Lateral unless an encroachment agreement is entered
into with Nampa-Meridian Irrigation District.
10. The Eight-Mile Lateral is to be piped by a party other than the applicant. If the.Lateral is not
piped by the time building permits are ready to issue for this development, the applicant shall
~,my'6~d Council
Sanuary 9, 2002
Page 3
be responsible for installing temporary fencing to keep debris from entering the waterway
during construction:
The legal description in the Certificate of Owners doesn't match the SUbdivision boundary as
shown on the face of the plat in the area of W. Harbor Point Drive. Please correct the legal to
match existing boundaries of record.
12.
Create a common area lot in the middle of W. Dawson Drive for the existing landscape island,
which is also shown on the preliminary plat.
13.
How is the existing well, which is shown within the fight-of-way nf Dawson Dr. on the
construction. . . plans, going to be handled, This well provides backup supply to the pressurized
lmgatlon system.
14.
Graphically depict 10-foot wide public utilities, drainage, and irrigation easements along the
northeast side of Lot 47, Block 19, and the south side of Lot 13; Block 29. The extra width is
required due to the crossing ora pressurized irrigation pipeline.
15.
The PLS preparing this plat shall affix his official stamp, signature and date to the plat map,
and Certificate of Surveyor. (Idaho Code §54-1215)
16. Change the date of Plat to 2002.
17.
Staff's failure to cite specific ordinance provisions or terms of the approved preliminary plat
does not relieve Applicant of responsibility for compliance.
GENERAL REQUIREMENTS
°
All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing
or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance
12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or
lateral users association, with written confirmation of said approval submitted to the Public
Works Department.
Any existing domestic wells and/or st/ptic systems within this project will have to be removed
from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used
for non-domestic purposes such as landscape irrigation.
One hundred watt, high-pressure sodium strectiights will be required at locations designated by
the Public Works Department. Ail streetiights shall be installed at subdivider's expense.
Typical locations are at street intersections and/or fire hydrants.
4. Submit "Final" letter from the Ada County Street Name Committee, approving the subdivision
and street names. Make any corrections necessary to conform.
5. Coordinate fire hydrant placement with the City of Meridian's Water Works Superintendent.
F 9, 2002
Page 4
6. Provide five-foot-wide sidewalks in accordance with City Ordinance Section 12-5-2.K.