Loading...
HomeMy WebLinkAboutSundance Sub No 3FP03-035HUB OF TREASURE VALLEY MAYOR A Good Place [o L1Va LEGAL DEPARTMENT Robert D. Come O CITY OF MERIDIAN (208)4GG-9272 Fax 4G6-4405 GITY C UNCIL MEMnERS PueLlc woRxs Tammy deweerd 33 EAST IDAHO BUILDING DHPARTMENT (208)898-5500 Fax 887-1297 Keith Bird MERHIIAN, II)AHO 83642 Cherie McCandless (208) 888433 ~ FAX (208) 887-4813 PLANNING AND ZONfNG William L.M. Nary City Clerk Ot'tice Pax (206) 888-4218 DEPAR"I'M PNT (208) 884-5533 ~ FAX 888-6854 STAFF REPORT: Hearing Date: June 24, 2003 To: Mayor, City Council and Planning & Zoning Commission ~ rj (`t L1 TT m q L1~1~1 ~/ L' From: Sonya Allen, Planner I ~ JUN 1 8 2Q03 Bruce Freckleton, Senior Engineering Tech City Of Meridian Re: Sundance Subdivision No. 3 City Clerk Office • Final Plat Approval of Thirty-Eight (38) Single-Family Residential Building Lots, Four (4) Office Building Lots, and Five (5) "Other" Lots on 16.17 Acres in an R-8 (PD) Zone, by Sundance Limited Company, LLC (Pile No. FP-03- 035). We have reviewed the above referenced submittals and offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY The applicant, Sundance Limited Company, LLC, has requested approval of the final plat for Sundance Subdivision No. 3, consisting of thirty-eight (38) single-family building lots, four (4) office building lots, and five (5) "other" lots on a 16.17 acre parcel of land located on the northeast corner of the Meridian and Ustick Road intersection. The City Council approved the annexation, preliminary plat, and conditional use permit (PD) for the subdivision in 2002. The submitted final plat appears to be in conformance with the approved preliminary plat. LOCATION The property is located at the northeast corner of Meridian and Ustick Road. North: Sundance Place Subdivision zoned R-8. South: Bedford Place Subdivision (R-8) and rural residential properties zoned R-1 (Ada County). East: Rural residential, zoned R-1 (Ada County). PP-03-035 Sundance Subdivision No. 1. FP Planning & Zoning Commission/Mayor & City Council Hearing Date: June 24, 2003 Page 2 West: Cedar Springs Subdivision, zoned R-4 and Meridian Settlers Park, zoned L-O. FINAL PLAT FINDINGS AND REQUIREMENTS Sections 12-3-3 J.2 and 12-3-5 D read as follows: "In determining the acceptance of a proposed subdivision, the Commission/Council shall consider the objectives of this title and at least the following: a. The conformance of the subdivision with the Comprehensive Development Plan; Staff finds the subdivision to be in conformance with the Comprehensive Plan. b. The availability of public services to accommodate the proposed development; Staff finds that public services can be made available to the lots within the proposed subdivision. c. The continuity of the proposed development with the capital improvement program; Staff finds that the subdivision will not require the expenditure of capital improvement funds. d. The public financial capability of supporting services for the proposed development; Staff finds that the development will not require major expenditures for providing supporting services. e. The other health, safety or environmental problems that may be brought to the Commission's attention. Staff finds that there should not be any other health, safety or environmental problems associated with this subdivision that may be brought to the Council or Commission's attention. SITE SPECIFIC COMMENTS /FINAL PLAT 1. Applicant is to meet all terms of the approved preliminary plat (PP-O1-015), conditional use permit (CUP-O1-030) and Development Agreement (Inst. No. 102056126). 2. The pressurized irrigation system within this development is to be owned and maintained by the Nampa & Meridian Irrigation District. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, asingle-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for FP-03-035 Sundence Subdivision No. ].PP Planning & Zoning Commission/Mayor & City Council Hearing Date: June 24, 2003 Page 3 the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Graphically depict 10-foot wide public utilities, drainage and irrigation easements along all rear lot lines that are not adjacent to the subdivision boundary. 4. Graphically depict 8-foot wide public utilities, drainage and irrigation easements along all side lot lines where pressurized irrigation mains run. 5. Graphically depict 5-foot wide public utilities, drainage and irrigation easements along all lot lines adjacent to the subdivision boundary that will be side lot lines in future phases. 6. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvements, including perimeter fencing and landscaping shall be installed and approved prior to obtaining certificates of occupancy. Surety, per City Ordinance 12-5-3, will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. Sanitary sewer service and municipal water to this site shall be via extensions from existing mains installed adjacent to the proposed subdivision. Applicant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department 8. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. 9. All drainage areas (detension/retension basins) must be designed to ensure that water is retained only during 25-year storm events, and for a period of time not to exceed 24 hours. Side slopes within drainage areas shall not exceed 3:1. 10. Revise the landscape plan to include landscaping within the Ustick Road right-of--way per MCC 12-13-10-9. A license agreement maybe required between the property owner and ACRD. 11. Add the "N" to the chord bearing curve C-2 in the Certificate of Owner's. 12. Correct "ARADIUS" in curve C-1 in the Certificate of Owner's. 13. Add or revise the following plat notes: • Add a note to the face of the plat (#18) referencing the approved Development Agreement (Inst. No. 102056126) and Conditional Use Permit (CUP-Ol-030). FP-03-035 Sundance Subdivision No. 3.FP Planning & Zoning Commission/Mayor & City Council Hearing Date: June 24, 2003 Page 4 14. Staff s failure to cite specific ordinance provisions or terms of the approved preliminary plat, does not relieve Applicant of responsibility for compliance. GENERAL REQUIREMENTS 1. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association, with written confirmation of said approval submitted to the Public Works Department. 2. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. Two-hundred-fifty and 100-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations aze at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. Street light contractor to obtain design and permit from the Public Works Department prior to commencing installation. 4. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 6. Coordinate fire hydrant placement with the City of Meridian's Water Works Superintendent. Provide five-foot-wide sidewalks in accordance with City Ordinance Section 12-5-2.K. 8. Any tree over 4" in caliper that is removed from the property shall be replaced by installing a dditional t rees, b eing t he a quivalent n umber o f c aliper i nches o f t rees t hat were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. Despite modifications to the phasing plans of this subdivision, staff supports the approval of this final plat with the aforementioned findings and conditions of approval. Pp-0}p35 Sundunm Subdivision No. ] FN MAYOR ROBERT D. CORRIE COUNCIL MEMBERS WILLIAM L.M. NARY KEITH BIRD TAMMY DE WEERD CHERIE MCCANDLE55 RURAL FIRE COMMISSIONERS RICHARD GREENE TERRY LEIGHTON STEVE ELLIOTT - e.l{{--.~ - eri~tcn - ~ tll nliU \. `r Y 1 t l H1FF KEN W. BOWERS DEPU'FS' CH7 P,F-FIRE PREVflVnoM1 JDSEPW SILV(I D~il'~"fY C~~IIL~= TRAI~'Mli Bu.1.JOnusov x-10 Eust I annlin Road M eril' I In S3(4^_ c7,Ov) NHS I ~3d ~'IF (' 1~ 1 1;4p MERIDIAN CITY/RURAL FIRE DEFAR'I.i'"IEN'I' .......;,,.,., ...__,....m ,. R~CEIVEI~ June 9, 2003 JUN ~ 0 233 City Of Meridian City Clerk Office TO: Mayor, City Council and the Meridian Planning & Zoning Commission FROM: Joseph Silva, Deputy Chief, Fire Prevention SUBJECT: Sundance Subdivision No. 3 FP 03-035 The following will be the requirements and/or concerns to provide minimum levels of fire protection for the proposed project: Commercial occupancies will require afire-flow consistent with the Uniform Fire Code to service the proposed project. Fire hydrants shall be placed an average of 400' apart. 1997 UFC Appendix III-A 2. The fire department requests that any future signalization installed as the result of the development of this project be equipped with Opticom Sensors to ensure a safe and efficient response by fire and emergency medical service vehicles. This cost of this installation is to be borne by the developer. 3. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 4. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. The proposed fire hydrant locations will be submitted to the Public Works for plan review. 5. All roads and fire lanes shall have a turning radius of 28' inside and 48' outside. 6. Insure that all yet undeveloped pazcels are maintained free of combustible vegetation per section 1103.2.4 of the Uniform Fire Code. 7. All access roads within the project shall have a cleaz driving surface with a minimum width of 20' available at all times. The typical street width of 33' will be allowed to have pazking on both sides. The typical street with a minimum width of 29' will be required to have restricted parking to only one side. UFC 902.2.2.1 8. Operational fire hydrants and temporary or permanent street signs are required before combustible construction begins. UFC 901.4.2 & 901.3 9. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have a turn around. 10. That afire-flow of 1,000 gallons per minute shall be available for duration of 2 hours to service the single family dwellings within the project. Fire hydrants shall be placed an average of 400' apart. 1997 UFC Appendix III-A CENTRAL CENTRAL DISTRICT HEALTH DEPARTMENT •~..'DISTRICT HEALTH Environmental Health DivisionRECF~T''~` 3" DEPARTMENT ~ ~' '~ ~~ ~~ lUN 1' r~Jf~s Rezone # Conditional Use # Preliminary /Final /Short Plat Q Return io: ^ Boise ^ Eagle ^ Garden City than ^ Kuna ^ACZ ^ Star ^ 1. We have No Objections to this Proposal. ^ 2. We recommend Denial of this Proposal. ^ 3. Specific knowledge as to the exact type of use must be provided before we can comment on this Proposal. ^ 4. We will require-more data concerning soil conditions on this Proposal before we can comment. ^ 5. Before we can comment concerning individual sewage disposal, we will require more data conceming the depth of: ^ high seasonal ground water ^ waste flow characteristics ^ or bedrockfrom original grade ^ other ^ 6. This office will require a study to assess the impact of nutrients and pathogens to receiving ground waters and/or surface waters. ^ 7. This project shall be reviewed by the Idaho Department of Water Resources concerning well construction and ,~/ wateravailability. /~ 8. After written a royal from appropriate entities are submitted, we can approve this proposal for: Y ~ entralsewage ^ communilysewagesystem ^ communitywaterwell ^ interim sewage ~sentral water ^ individual sewage ^ intlividualwater ~9. The following plan(s) must be submitted to and approved by the Idaho Department of Health & Welfare, Division of vironmental Quality: I sewage ^ community sewage system ^ communty water ^ sewage dry lines ahwater ~0. Run-off is not to create a mosquito breeding problem. fV'^~~11. This Department would recommend deferral until high seasonal ground water can be determined if other considerations indicate approval. ^ 12. If restroom facilities are to be installed, then a sewage system MUST be installed to meet Idaho State Sewage Regulations. ^ 13. We will require plans be submitted for a plan review for any: ^ food establishment ^ swimming pools or spas ^ child care center ^ beverage establishment ^ grocery store ,~4. ~~d.~ ~i~ t'.~'~ .~~~L~a ~7o>,~w,¢ ~c-s~ Date: ~/~/ ~ ~/ ~- ,~"Q~~~,z~~~a.`- Reviewed By: Review Sheet conosiaoiNc CENTRAL ~ W DISTRICT ~THEALTH DEPARTMENT MAIN OFFICE • 707 N. ARMSTRONG PL. • BOISE, ID 83704-0825 • (208) 375-5211 • FAX 327-8500 To prevent and zrea! disease mrd disabifiry; to promote healtb~+lifesry+les; and ro prmec! and promote the heahh and qua/iq~ ojour environment. STORM WATER MANAGEMENT RECOMMENDATIONS It is recommended that storm water bepre-treated prior to discharge to the subsurface to prevent impact to ground water and surface water quality. The engineers and architects involved with the design of this project should obtain current best management practices for storm water disposal and design a storm water management system that is preventing groundwater and surface water degradation. Manuals that could be used for guidance are: State ofldaho Catalog of Stormwatel° Best Management Practices For Idaho Cities and Counties. Prepared by the Idaho Department of Environmental Quality, July 1997. Stormwater Best Management Practices Guidebook. Prepared by City of Boise Public Works Department, May 2000. We.13 m 0303 Ada /Boise County Office 707 N. Armstrong PI. Boise, ID 837D4 Envira. Health: 327-7499 Family Plannilg: 327-7400 Immunizations: 327-7450 Senior Nutrition: 327-7460 V4Q 327-7488 FAA: 327-8500 Serving YaAe~~, Elmore, Baisg and Ada Cou+rties Elmore County Office 520 E. 8th 8t. North Mountain Home, ID 83647 Enviro. Health: 587-9225 Family Health: 5E7-4407 N7C: 587-440° FAA: 587-352' Valley County Office 703 N. 1st 5t. P.O. Box 1448 Mdall, ID 83fi38 Ph. 634-7194 FAA: 634-2774 RECEI~TEI~ _~ U N 13 2003 City of Meridian City Clerk Office r.,tza ~c ~~~~ ~Jnrus yatio~c ~uat~iict 15D3 FIRST STREET SOUTH NAMPA, IDAHO 83651-4395 FAX # 208-463-0092 William Berg City of Meridian 33 East Idaho Ave. RE: Sundance Sub No. 3 Dear Will: Phones: Area Code 208 OFFICE: Nampa 466-7861 SHOP: Nampa 466-0663 Nampa & Meridian Irrigation District has no facilities impacted by this phase of this project. All laterals and waste ways must be protected. All municipal surface drainage must be retained on site. If any surface drainage leaves the site, the Nampa & Meridian Irrigation District must review drainage plans. Please contact Donna Moore at 466-7861 for further information. The developer must comply with Idaho Code 31-3805. It is recommended that irrigation water be made available to all developments within the Nampa & Meridian Irrigation District. No fixrther review is required by Nampa & Meridian Irrigation District, as long as all stone drainage is retained on-site Thank you, r9GC%~" ~-rd~vr` Bill Henson, Asst. Water Superintendent Nampa & Meridian Irrigation District BH/dbg pc: Water Superintendent. File -Office File -Shop APPROXIMATE IRRIGABLE ACRES RIVER FLOW RIGHTS- 23,000 BOISE PROJECT RIGHTS - 40,000 June 9, 2003 MAYOR Robert D. Corrie CITY COUNCIL MEMBERS Tammy de Weerd William L. M. Nary Cherie McCandless Keith Bird ,~ -~;~, ; n ~.:Jj CITV OF 1tf'risl' C~eri~i~n - sfi ll IDAHO WITH THE CITY OF MERIDIAN LEGAL DEPARTMENT (208) 4GG-9272 • FAX 4GG-4405 PARKS & RECREATION (208) 888-3579 • Fax 898-5501 PUBLIC WORKS (208) 898-5500 • Fax 887-1297 BUILDING DEPARTMENT (208) 887-221 I • Fax 887-1297 PLANNING & ZONING (208) 884-5533 • Fax 888-G854 To insure that your comments and recommendations will be considered by the Meridian City Council please submit your comments and recommendations to Meridian City Hall Attn: Will Berg, City Clerk, by: June 19, 2003 Transmittal Date: June 3, 2003 Hearing Date: June 24, 2003 File No.: FP 03-035 Request: Request for Final Plat approtral of 38 residential building lots and 4 office lots'. on 16.17 acres in an R-8 (PD) zone for Sundance Sub No. 3 By: Sundance Limited Company, LLC Location of Property or Project: northeast comer of N. Meridian Road and E. Ustick Road David Zaremba, P/Z nrnvAr;vAC,ra•) Jerry Centers, P2 ao vow, vac, F>e Leslie Mathes, P/Z mb vu; via ~ Michael Rohm, P/Z (rrcvut,vAF>~ Keith Borup, P2 rrru va+. v~G r<rl Robert Corrie, Mayor Bill Nary, C!C -Tammy deWeerd, C/C Keith Bird, C/C Cherie McCandless, C/C ,i Water Department Sewer Department Sanitary Service rxuwvt,vac,rr) Building Department Fire Department Police Department City Attorney City Engineer City Planner Parks Department Meridian School District (rta~ Meridian Post Office (~Pnvawn Ada County Highway District Ada County Development Services Central District Health Nampa Meridian brig. District Settlers Irrigation District Idaho Power Co. (srmroNy) U.S. West (EV~vvwny) Iniermountain Gas (~vv onm Bureau of Reclamation (a<waewc„y~ Idaho Transportation Department rHO~ Ada County rnz«oif Ada County Assess. Land Records (FVi~~ Meridian Development Corporation RECEDED JUN - 5 Zppg City Of Meridian City Cierk Office 33 EAST IDAHO AVENUE • MERIDIAN, IDAHO 83642 • (208) 888-4433 City Clerk Office Fax (208) 888-4218 Human Resources Fax (208) 8848723 Finance & Utility Billing Fax (208) 887-4813 MAYOR Robert D. Corrie CITY COUNCIL MEMBERS Tammy de Weerd William L. M. Nary Cherie McCandless Keith Bird (`!rye. c ,~y CITY OF j'~~ ~' ~~ C~ ri~icn•4 ~- Il IDAHO LEGAL DEPARTMENT (208) 4G6-9272 • FAX 4GG-4405 PARKS & RECREATION (208) 888-3579 • Fax 898-5501 PUBLIC WORKS (208) 898-5500 • Fax 887-1297 BUILDING DEPARTMENT (208) 887-2211 • Fax 887-1297 PLANNING & ZONING (208) 884-5533 • Fax 8R8-GR54 WITH THE CITY OF MERIDIAN To insure that your comments and recommendations will be considered by the Meridian City Council please submit your comments and recommendations to Meridian City Hall Attn: Will Berg, City Clerk, by: June 19, 2003 Transmittal Date: June 3, 2003 Hearing Date: File No.: FP 03-035 Request: Request for Final Plat approval of 38 residential building lots and 4 office lots. on 16.17 acres in an R-8 (PD) zone for Sundance Sub No. 3 ey: Sundance Limited Company, LLC Location of Property or Project: northeast comer of N. Meridian Road and E. Ustick Road David Zaremba, P/Z ma vaR va4 r~ Jerry Centers, P/Z auvaa, vnGrrl Leslie Mathes, P2 n+o vaR vaq s~ Michael Rohm, P/Z rxnvartvac,Fn~ Keith Borup, P2 reovutvnc,~ Robert Come, Mayor Bill Nary, C/C Tammy deWeerd, C/C Keith Bird, C/C Cherie McCandless, C/C Water Department ~~Sewer Department Sanitary Service mrovara va5~ Building Department Fire Department Police Department City Attorney City Engineer City Planner Parks Department Meridian School District (nmPV) Meridian Post Office rr~~I Ada County Highway District Ada County Development Services Central District Heahh Nampa Meridian brig. District Settlers Irrigation District Idaho Power Co. rrrmv~v» U.S. Westr~«Na Intermountain Gasrr-~Paom~ Bureau of Reclamation ra<wrv,mn Idaho Transportation Department ~,or-vr Ada County rnza~y) Ada County Assess. Land Records r~~~nl Meridian Development Corporation Historical Preservation Commission Your Concise Remarks: ~I,,.!`,,.Nn.nnvuif. RECEI~TED JUN - 5 2003 City OFMeritiian City Clerk Office R~;~EI ~tl as CITY OF ~'~ ;~?IDIAly WASTEWATER DEPT. 33 EAST IDAHO AVENUE • MERIDIAN, IDAHO 83642 • (208) 888-4433 City Clerk Ot'tice Fax (208) 888-4218 Human Resources Fax (208) 884-8723 Finance & Utility Billing Fax (208) 887-4813 MAYOR Robert D. Corrie CITY COUNCIL MEMBERS Tammy de Weerd William L. M. Nary Cherie McCandless Keith Bird ~~ n ,~ ~~~~ ,,~~'' CITY OF 9i'~~,_,~ (l IDAHO LEGAL DEPARTMENT (20H) 4GG9272 • FAX 4GG-4405 PARKS & RECREATION (208) 888-3579 • Fax 896-5501 PUBLIC WORKS (208) 898-5500 • Fax 887-1297 BUILDING DEPARTMENT (208) 887-2211 • Fax 887-1297 PLANNING & ZONING (208) 884-5533 • Fax 888-6854 WITH THE CITY OF MERIDIAN To insure that your comments and recommendations will be considered by the Meridian City Council please submit your comments and recommendations to Meridian Ciry Hall Attn: Will Berg, City Clerk, by: June 19, 2003 Transmittal Date: June 3, 2003 File No.: FP 03-035 Hearing Date: June 24, 2003 Request: Request for Final Plat approval of 38 and 4 on 16.17 acres in an R-8 (PDy zone for Sundance Sub No. 3 Bv: Sundance Limited Company, LLC Location of Property or Project: northeast comer of N. Meridian Road and E. Ustick Road DavidZaremba,P/Z ~„vnrzvnc,r-» Jerry Centers, P/Z pro vaR, vac, r-» Leslie Mathes, P/Z (NO vaa vac, ~ Michael Rohm, P/Z rnw vaR va0. m) Keith Bonip, P/Z r~ vue, vac, r~ Robert Come, Mayor Bill Nary, C/C Tammy deWeerd, C/G Keith Bird, C/C Cherie McCandless, C/C Water Department Sewer Department SanRary Service mro vart vac, rr) Building Department Fire Department Police Department City Attorney City Engineer City Planner f Parks Department Meridian School District ~~ Meridian Post Office (Frivra~y) Ada County Highway District Ada County Development Services Central District Health Nampa Meridian In•ig. District Settlers Irrigation District. Idaho Power Co. [r-P~va „ly) U.S. West ~~P~„» Intermountain Gas~am~,,,M Bureau of Reclamation (r~mao~yry) Idaho Transportation Department ao~ Ada County (az~ Ada County Assess. Land Records ~rrPway~ Meridian Development Corporation Historical Preservation Commission RECEIVED ~~'~ ~ i ~ ZOO;i City of Meridian City Clerk Office 33 EAST IDAHO AVENUE • MERIDIAN, IDAHO 83642 • (208) 888-4433 City Clerk Office Fax (208) 888-4218 Human Resources Fax (208) 8848723 Finance & Utility Billing Fax (208) 887-4813