Loading...
HomeMy WebLinkAboutFire Department CommentsThe following will be the requirements and/or concerns to provide minimum levels of fire... Page 1 of 1 Tara Green From: Joe Silva Sent: Friday, January 02, 2009 4:42 PM To: Joe SlHra; Sonya Allen (watterss(~meridiancity.org); Brad Hoaglun; Charlie Rountr®e; David Zaremtm; Keith Bird; Tammy de Weerd; Elijah HM. Nary; Jaycee Holman; Machelle Hill; Nancy Radford; Sh®ree Finch; Tara Green; Anna Canning; Bi0 Nary Subject: Comments on Fairview Lakes Retai! AP 08-019 Mayor de Weerd & City Council No specific site plan was provided to identify the area where the proposed landscape island is to be located, therefore the following will be the concerns to provide minimum levels of fire protection for the Comments on Fairview Lakes Retail AP 08-019 project: 1. All entrance and internal roads and alleys shall have a turning radius of 28' inside and 48' outside radius. 2. All fire lanes shall be straight or have a turning radius of 28' inside and 48' outside and shall have a clear driving surface which is 20' wide and support an imposed weight of 75,000 GVW. These issues will have to be addressed on the final design of this project, please have the project designer submit a revised parking lot plan to be approved by the Meridian Fire Department. Joseph P. Silva Deputy Chief/ Fire Prevention Meridian Fire Department jsilva~meridiancity.org 33 E. Broadway Ave., Meridian, ID 83642 (208} 888-1234 Office (208} 895-0390 Fax 1/2/2009