Loading...
HomeMy WebLinkAboutWoodbridge Subdivision No. 2 PP-01-019BEFORE THE CITY COUNCIL OF THE CiTY OF MERIDIAN C/C 12/15/01 IN THE MATTER OF THE REQUEST FOR PRELIMINARY PLAT FOR WOODBRIDGE NO. 2, LOCATED EAST OF SOUTH LOCUST GROVE ROAD AND SOUTH OF EAST FRANKLIN ROAD, MERIDIAN, IDAHO BY: WOODBRIDGE COMMUNITY, LLC, APPLICANT ) ) ) ) ) ) ) ) ) ) ) ) Case No. PP-01-019 FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT The above entitled matter coming on regularly for public hearing before the City Council on December 18, 2001, and Shari Stiles, Plam~ing and Zoning Administrator, and Gary Smith, Public Works Director, both appeared and testified, and appearing and testifying on behalf of the Applicant were Derrick O'Neal and Scott Beecham, and the City Council having received a report from David McKinnon, Planner for the Planning and Zoning Department, and Bruce Freckleton, Engineering Technician III, and the City Council having received as part of the record of this matter the recommendation to City Council of the Planning and Zoning FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 1 Commission and the applicant having submitted the "PRELIMINARY PLAT, AUGUST 2001, SNORTING BULL SUBDIVISION NO. 2 (WOODBRIDGE SUBDIVISION PHASE II), A PARCEL OF LAND SITUATED IN THE SE I/4 OF THE NW 1/4 OF SECTION 17, T. 3N., R. 1E., B.M., MERIDIAN, ADA COUNTY, IDAHO,/OB NO. 01-034-01, SHEET NO. 1, 1: \ WOODBRIDGE NO. 2 (01-034- 00)\DRAWINGS\WOODBRIDGE 2 PRE_PLAT.DWG 8-14-01, ENGINEERING NORTHWEST, LLC, WOODBRIDGE COMMUNITY, LLC - DEVELOPER/SUBDIVIDER", submitted for preliminary plat approval and which preliminary plat for approval application is herein received and adjudged by the City Council pursuant to Meridian City Code § 12-3-3. Therefore the City Council makes the following findings: FINDINGS OF FACT 1. That the proposed development is in conformance with the Comprehensive Plan by reason of the fact that it lies within the existing Urban Area as defined in the Meridian Comprehensive Plan Generalized Land Use Map, Infrastructure Planning Analysis Comprehensive Plan and Map, adopted December 21, 1993, and the property is presently zoned Low Density Residential District (R- 4), and requires connection to the Municipal Water and Sewer System. [Meridian City Code § 11-7-2 K] FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 2 2. The preliminary plat is in conformance with the Comprehensive Plan City of Meridian adopted December 21, 1993, Ordinance No. 629. 3. It is determined that Urban Services can be made available to accommodate the proposed development if the plat complies with the requirements and conditions hereinafter set forth as conditions of preliminary plat approval. 4. The proposed development is a continuity of the proposed development within the City's Capital Improvement Program and if the conditions which are requested by the Planning and Zoning Administrator and the Engineering Technician III and as proposed by the developer as stated on the preliminary plat there will be public financial capability of supporting services for the proposed development. 5. The development if built in accordance with the conditions and as proposed, will not create health, safety or environmental problems and there have been no specifics of any such concerns brought to the Council's attention. 6. It is found that the Recommendation To City Council of the Planning and Zoning Commission is reasonable and appropriate for the conditions of approval of the preliminary plat as hereinafter set forth. 7. The applicant has submitted for consideration of this approval drawing of the preliminary plat herein designated as: "PRELIMINARY PLAT, AUGUST 2001, SNORTING BULL SUBDIVISION NO. 2 (WOODBRIDGE SUBDIVISION FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBKIDGE NO. 2 / (PP-01-019) 3 PHASE II),A PARCEL OF LAND SITUATED IN THE SE i/4 OF THE NW 1/4 OF SECTION 17, T. 3N., R. 1E., B.M., MERIDIAN, ADA COUNTY, IDAHO, JOB NO. 01-034-01, SHEET NO. l, J: \ WOODBRIDGE NO. 2 (01-034- 00)kDRAWINGS\WOODBRIDGE_2_PRE_PLAT.DWG 8-14-01, ENGINEERING NORTHWEST, LLC, WOODBRIDGE COMMUNITY, LLC - DEVELOPER/SUBDIVIDER". DECISION AND ORDER Pursuant to the City Council's authority as provided in Meridian City Code § I2-3-5 and based upon the above and foregoing Findings of Fact which are herein adopted: IT IS HEREBY ORDERED AND THIS DOES ORDER 1. The Preliminary Plat of the applicant as evidenced by "PRELIMINARY PLAT, AUGUST 2001, SNORTING BULL SUBDIVISION NO. 2 (WOODBRIDGE SUBDIVISION PHASE II), A PARCEL OF LAND SITUATED IN THE SE l/4 OF THE NW 1/~ OF SECTION 17, T. 3N., R. 1E., B.M., MERIDIAN, ADA COUNTY, IDAHO, JOB NO. 01-034-01, SHEET NO. 1, J: \ WOODBRIDGE NO. 2 (01-034- 00)kDRAWINGS\WOODBRIDGE_2_PRE_PLAT.DWG 8-14-01, ENGINEERING NORTHWEST, LLC, WOODBRIDGE COMMUNITY, LLC - DEVELOPER/SUBDIVIDER" is hereby conditionally approved; and 2. The conditions of approval are as follows to-wit: Adopt the Planning and Zoning Administrator and Assistant City Engineer Recommendations as follows: FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-O19) 4 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Sanitary sewer and water service to this site shall be via extensions from existing main lines adjacent to the property. Sewer Latecomer fees shall be paid prior to city signatures on the final plat or the applicant shall enter into a payment agreement with the City prior to signature on the final plat. The proposed domestic water system for this developlnent, as analyzed by our computer model, shall provide water pressures in the low 40 to mid 50 PSI range. The computer modeled water volume and pressure shall provide a fire flow of 1000 GPM and meet the 20 PSI residual requirements. Customers might view the system pressures as borderline, even though they exceed the minimum standards established by the State of Idaho Department of Environmental Quality. Connecting this subdivision to the higher city system pressure zone currently serving the St. Luke's area would raise system pressures by approximately 30 PSI. Applicant shall be required to continue the 12-inch dianxeter water main from Phase I through Phase II in order to facilitate future connection to the high-pressure main in the Magic View Subdivision. Create a 20' wide common lot over the existing 20' wide sanitary sewer easement, crossing the southerly side of Lots 106-110, Block 6. No occupancy permits shall be issued to any home located within the 100-year flood plain unless an approved Elevation Certificate is completed for the structure or a Letter of Map Revision has been issued for the lot, certifying that the property is no longer located in the 100- year floodplain. A detailed landscape plan and an irrigation plan, including performance specifications, shall be submitted with the Final Plat application. The applicant shall submit a detailed emergency vehicle access plan that is acceptable to both the Meridian Police and Fire Departments with the Final Plat application. The emergency vehicle access plan shall be in accordance with the section 2.1.6 of the FF/CL for CUP 99-037. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 5 2.9 All parldng and areas of circulation shall be paved, striped, and meet minimum dimension requirements as required per City Ordinance and ACHD standards. 2.10 A drainage plan designed by a State of Idaho licensed architect or engineer is required and shall be submitted to the City Engineer (Ord. 557, 10-1-91) for all off-street parldng areas. Storm ~vater treatment and disposal must be designed in accordance with Department of Environmental Quality 1997 publication, "Catalog of Storm Water Best Management Practices for Idaho Cities and Counties" and City of Meridian standards and policies. Off-site disposal into surface water is prohibited unless the jurisdiction which has authority over the receiving stream provides written authorization prior to development plan approval. The applicant is responsible for filing all necessary applications with the Idaho Department of Water Resources regarding Shallow Injection Wells on the final plat. 2.11 Assessment fees for water and sewer service are determined during the building plan review process. 2.12 Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 5-7-517. Wells may be used for non-domestic purposes such as landscape irrigation. 2.13 Submit a copy of the Ada County Street Name Committee's final approval letter for the subdivision name, lot and block numbering. Make any corrections necessary to conform. Adopt the ACHD Recommendations as follows: 2.14 Dedicate 48-feet of right-of-way from the centefline of Locust Grove Road abutting the parcel by means of recordation of a final subdivision plat or execution of a warranty deed prior to issuance of a building permit (or other required permits), whichever occurs first. 2.15 Construct or bond for an 8-foot wide (minimum) pathway along Locust Grove Road abutting the parcel (approximately 1,325-feet). The pathway may be constructed of asphaltic concrete, if the homeowners association for this development is required to provide perpetual maintenance for the asphalt pathway. Coordinate the location and elevation of the sidewalk with District staff. FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-Oi-O19) 6 2.16 Any proposed landscape islands/medians within the public right-of-way dedicated by this plat shall be owned and maintained by a homeowners association. Notes of this should be required on the final plat. 2.17 Construct the following streets: Bollman Way Baltimore Drive Warren Place Pratt Way Pegram Drive as 29-foot street section with curb, gutter and 5-foot wide concrete sidewalk within 50-feet of fight-of-way and located as proposed. Parking shall be restricted on one side of each of the roadways. A signage plan shall be submitted for review and approval by Planning and Development staff. 2.18 Unless otherwise approved, the applicant shall be required to construct all public roads within the subdivision as 36-foot street sections (as measured from back of curb to back of curb) with curb, gutter, and 5- foot wide concrete sidewalks within 50-feet of fight-of-way. 2.19 In lieu of constructing sidewalks on both sides of Woodbridge Drive from Locust Grove Road to the Warren Place, the applicant may construct an 8-foot wide (nxinimum) asphalt pathway on one side of the road only. Provide pedestrian cross walks at all four internal intersections of Woodbridge Drive. The asphalt pathway shall be owned and perpetually maintained by a homeowners association if it is constructed of asphaltic concrete paving. Coordinate the design of the pedestrian pathway and crosswalks with District staff. 2.20 Woodbridge Drive between Locust Grove Road and Warren Place shall be designated as a residential collector street with no front-on housing. Access restrictions for this street segment shall be stated on the final plat. District policy requires that this street segment be constructed as a 36-foot street section with curb, gutter and an 8-foot wide (minimtm~) asphalt pathway along this segment of the residential collector. Unless otherwise noted, parldng shall be prohibited on this street segment. Coordinate the signage plan with District staff. 2.21 Construct a turnaround at the southern terminus of Warren Place. The turnaround shall be constructed to provide a minimum outside turning radius of 45-feet. The applicant shall also be required to provide a minimum of a 21-foot street section (as measured from back of curb to FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 7 back of curb) on either side of any center islands within the turnaround. The median shall be constructed a minimum of 4-feet wide to total a minimum of a 100-square foot area. Dedicate 54-feet of right-of-way plus the additional width of the median. Provide written approval of the design of the turnaround from the emergency fire service for the area where the development is located. 2.22 Locate the main project entrance off Locust Grove Road approximately 700-feet north of the south property line. The street section on either side of shall be designed with a minimum of two 21-foot street sections (as measured from back of curb to back of curb) on either side of the center median and the median shall be constructed a minimum of 4-feet wide to total a 100-square foot area. The applicant will be required to dedicate 54-feet of right-of-way plus the additional width of the median. 2.23 The four intersections off the main east/west road shall be designed with two 21-foot street sections (as measured from back of curb to bacl~ of curb) on either side of center medians and the medians shall be constructed a minimum of 4-feet wide to total a 100-square foot area. The applicant will be required to dedicate M-feet of right-of-way plus the additional width of the median. 2.24 Construct a center turn lane on Locust Grove Road for the main project/Locust Grove Road intersection. The turn lane shall be constructed to provide a minimum of 100-feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. 2.25 Terminate Woodbridge Drive for this phase of development at Five Mile Creek. The road shall be required to be extended further to the east in a future phase of development (see approval for MCUP99-037). The applicant shall construct or bond for the required box culvert over the Five Mile Creek prior to final plat approval. The applicant may reduce the street section over the bridge to a minimum with of 25-feet with curbs, gutters, and sidewalks. Coordinate the design of the bridge with District staff. 2.26 The applicant is proposing a community center on Lot 66, Block 3, across from Warren Place. The applicant should be required to align a driveway to the community center on Woodbridge Drive with Warren Place on the south side of the road. Coordinate the design and location of the driveway with District staff. FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 8 2.27 Other than main project entrance off Locust Grove Road specifically approved with this application, direct lot or parcel access to Locust Grove Road is prohibited. Lot access restrictions, as required with this application, shall be stated on the final plat. 2.28 Additionally, the Applicant shall comply with the Standard Requirements and Site Specific Requirements of both ACHD's letters dated October 24, 2001 and October 26, 2001. Adopt the Recommendations of Central District Health as follows: 2.29 The Applicant's central sewage and central water plans must be submitted to and approved by the Idaho Department of Health & Welfare, Division of Environmental Quality. 2.30 Run-off is not to create a mosquito breeding problem. 2.31 Stormwater shall be pretreated through a grassy swale prior to discharge to the subsurface to prevent impact to groundwater and surface water quality. 2.32 The Engineers and architects involved with the design of the subject project shall obtain current best management practices for stormwater disposal and design a stormwater management system that prevents groundwater and surface water degradation. Adopt the Recommendations of the Meridian Fire Dept. as follows: 2.33 A fire-flow of 1,000 gallons per minute shall be available for a duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart at approved locations. 2.34 Operational fire hydrants and temporary or permanent street signs are required before combustible construction begins. 2.35 Acceptance of water supply for fire protection is contingent upon acceptance of the water system by the City of Meridian. 2.36 Final approval for fire hydrant location shall be by the Meridian Fire Department. 2.37 All turning radii shall be a minimum of 28' inside and 48' outside. FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-OI-O19) 9 2.38 Insure that all yet undeveloped parcels are maintained free of combustible vegetation. 2.39 The roadways shall be built to Ada County Highway standards. 2.40 The proposed 115-lot subdivision with an estimated 2.8 residents per household would have a total estimated population of 322 residents at build out. 2.41 An approved temporary turn-around is required for any dead-ends over 150' that are created by the Phasing Plan. Adopt the Nampa & Meridian Irrigation District Recommendations as follows: 2.42 The District's Fivemile Drain courses along the east boundary of the above-mentioned proposed project. The easement for this drain must be protected; any encroachments without approved plans and a signed License Agreement are unacceptable. Additionally, the Applicant shall comply with the action of the City Council taken at their December 18,2001 meeting as follows: 2.43 Applicant shall be required to continue the 12-inch diameter water main from Phase I through Phase II in order to facilitate future connection to the high-pressure main in the Magic View Subdivision. By action_.,_°f the City Council at its regular meeting held on the day of xL~ff/q~//] , 2002. ROLL CALL COUNCILMAN BIRD VOTED COUNCILWOMAN deWEERD COUNCILWOMAN McCANDLESS VOTED ~ VOTED ~45r4__ FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 10 COUNCILMAN NARY ~YOR ROBERT D. CORRIE (TIE BREAIfd~R) VOTED VOTED Copy served upon Applicant, The Planning and Zoning Department, Public Works Department and City Attorney. City Clerk Dated:. \~,JPA_NTS40_PDC~SERVER_ZXWorkkMkMeridiankMetidian I5360Ivl~Woodbridge #2 PP01-019WfCIsOrdPP.doc FINDINGS OF FACT AND CONCLUSIONS OF LAW AND ORDER OF CONDITIONAL APPROVAL OF PRELIMINARY PLAT WOODBRIDGE NO. 2 / (PP-01-019) 11