HomeMy WebLinkAboutParamount Sub AZRECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 1
BEFORE THE PLANNING AND ZONING COMMISSION
IN THE MATTER OF THE
REQUEST FOR ANNEXATION &
ZONING OF 397.11 ACRES TO R-8,
R-40, L-O, & C-G ZONES FOR
PARAMOUNT SUBDIVISION
PARAMOUNT, LLC,
Applicant
)
)
)
)
)
)
)
)
Case No. AZ-03-006
RECOMMENDATION TO CITY
COUNCIL
1. The property is approximately 397.11 acres in size and is generally located within
the square mile of Chinden Rd., Meridian Rd., McMillan Rd. and Linder Rd.,
Meridian. The property is designated as Low Density Residential, Medium
Density Residential, & Mixed Use - Neighborhood.
2. The owner of record of the subject property is Paramount, LLC, 12426 W.
Explorer Drive, Suite 220, Boise, Idaho 83704.
3. Applicant is same as owner.
4. The subject property is currently zoned RUT & R1 (Ada County) and consists of
vacant land.
5. The Applicant requests the property be zoned as R-8 (Medium Density
Residential), R-40 (High Density Residential), L-O (Limited Office), & C-G
(General Retail & Service Commercial).
6. The subject property is bordered to the north by rural residential (zoned RUT &
R1, Ada County), to the south by rural residential (zoned RUT, Ada County) and
the proposed Cedar Springs North Subdivision (zoned R-8), to the east by rural
residential (zoned RUT, Ada County), and to the west by the proposed Lochsa
Falls Subdivision (zoned R-4) and several rural residential properties (zoned
RUT, Ada County).
7. The property which is the subject of this application is within the Area of Impact
of the City of Meridian.
8. The entire parcel of the property is included within the Meridian Urban Service
Planning Area as defined in the Meridian Comprehensive Plan.
9. The Applicant proposes to develop the subject property in the following manner:
Planned Development consisting of 764 single family building lots, 73 townhouse
lots, 270 apartments, 4 mixed-use areas with approximately 577,606 s.f. of office
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 2
and retail space, and 32 common lots on 392.17 acres in proposed R-8, R-40, L-
O, and C-G zones.
10. The Applicant requests zoning of the subject real property as R-8, R-40, L-O and
C-G zones which is consistent with the Meridian Comprehensive Plan
Generalized Land Use Map which designates the subject property as Low Density
Residential, Medium Density Residential Mixed Use – Neighborhood.
11. There are no significant or scenic features of major importance that affect the
consideration of this application.
12. The Planning and Zoning Commission recognized the concerns of Capt. Bill
Musser, Meridian Police Department in a memo dated March 19, 2003 and
Wendel Bigham, Joint School District No. 2, expressed in his letter dated
February 12, 2003.
RECOMMENDATION
The Meridian Planning and Zoning Commission hereby recommends to the City
Council of the City of Meridian that they approve the requested Annexation And Zoning
as requested by the applicant for the property described in the application, subject to the
following:
A. Adopt the Recommendations of the Meridian Planning & Zoning Department as
follows:
ANEXATION AND ZONING CONDTIONS OF APPROVAL
1. Any existing domestic wells and/or septic systems within this project will
have to be removed from their domestic service, per City Ordinance Section 5-7-
517, when services are available from the City of Meridian. Wells may be used
for non-domestic purposes such as landscape irrigation.
2. All irrigation ditches, laterals or canals, exclusive of natural waterways,
intersecting, crossing or lying adjacent and contiguous to the parcel shall be tiled
per City Ordinance 12-4-13. Plans will need to be approved by the appropriate
irrigation/drainage district, or lateral users association (ditch owners), with
written approval or non-approval submitted to the Public Works Department. If
lateral users association approval can’t be obtained, plans will be reviewed and
approved by the Meridian City Engineer prior to final plat signature.
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 3
3. A Development Agreement shall be entered into between the Developer
and the City of Meridian that will require, among other conditions, that all future
commercial, townhouse, and multi-family uses obtain conditional use permit
approval prior to development, the construction of the multi-use pathway, and
limiting Lots 1-13, Block 32, Lots 1-12, Block 33, Lots 1-12 Block 34 and Lots 1-
13, Block 35 to attached and townhouse construction only and limiting Lots 1-13
Block 30, Lots 1-2 Block 31, Lots 1-12 Block 36, and Lots 1-13 Block 37 to one
dwelling per lot.
4. The applicant shall be required to dedicate a permanent easement, and a
temporary construction easement, through the project to Meridian road for the
North Slough Sewer Trunk after preliminary plat approval by the Meridian City
Council, and prior to submittal of the application for the final plat of phase one.
5. The applicant shall remove Lot 57, Block 3 from the legal description (the
southwest corner of the subdivision) because it does not meet the minimum
findings for an “excepted” use (MCC 12-6-3). A revised legal description for the
development shall be submitted to the Public Works Department for review, prior
to approval.
B. Adopt the Recommendations of the ACHD as follows:
Site Specific Conditions of Approval
1. The applicant shall do one of the following requirements for Meridian
Road:
a. Dedicate by donation an additional 10-feet of right-of-way along
Meridian Road, and construct a minimum 5-foot wide concrete sidewalk
along Meridian Road, located a minimum of 28-feet from the centerline of
the right-of-way.
b. Do not dedicate additional right-of-way, but construct a minimum
5-foot wide concrete sidewalk along Meridian Road, located a minimum
of 28-feet from the centerline of the right-of-way, in an easement provided
to the District.
c. Do not dedicate additional right-of-way, but construct a minimum
5-foot wide concrete sidewalk along Meridian Road, located at the back
edge of the existing right-of-way. Accomplish all necessary adjustments
to properly accommodate existing drainage and utilities.
2. The applicant shall do one of the following requirements for Linder Road:
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 4
a. Dedicate by donation an additional 23-feet of right-of-way along
Linder Road, and construct a minimum 5-foot wide concrete sidewalk
along Linder Road, located a minimum of 41-feet from the centerline
of the right-of-way.
b. Do not dedicate additional right-of-way, but construct a minimum 5-
foot wide concrete sidewalk along Linder Road, located a minimum of
41-feet from the centerline of the right-of-way, in an easement
provided to the District.
c. Do not dedicate additional right-of-way, but construct a minimum 5-
foot wide concrete sidewalk along Linder Road, located at the back
edge of the existing right-of-way. Accomplish all necessary
adjustments to properly accommodate existing drainage and utilities.
3. The applicant shall do one of the following requirements for McMillan
Road:
a. Dedicate by donation an additional 10-feet of right-of-way along
McMillan Road, and construct a minimum 5-foot wide concrete sidewalk
along McMillan Road, located a minimum of 28-feet from the centerline
of the right-of-way.
b. Do not dedicate additional right-of-way, but construct a minimum
5-foot wide concrete sidewalk along McMillan Road, located a minimum
of 28-feet from the centerline of the right-of-way, in an easement provided
to the District.
c. Do not dedicate additional right-of-way, but construct a minimum
5-foot wide concrete sidewalk along McMillan Road, located at the back
edge of the existing right-of-way. Accomplish all necessary adjustments
to properly accommodate existing drainage and utilities.
4. Construct West Studio Drive to intersect North Meridian Road
approximately 1,300-feet north of McMillan Road, as proposed.
5. Construct West Producer Street to intersect Meridian Road approximately
2,470-feet north of McMillan Road, as proposed.
6. Construct West Director Street to intersect Meridian Road approximately
960-feet south of Chinden Boulevard, as proposed.
7. Construct West Paramount Drive approximately 2,420-feet south of
Chinden Boulevard to align with West Cayuse Avenue (a main entrance that was
approved on May 22, 2002 as a part of Lochsa Falls Subdivision), as proposed.
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 5
8. Construct West Studio Drive to intersect McMillan Road approximately
1,260-feet west of Meridian Road, as proposed.
9. Relocate the intersections of West Dreyfus Street/Producer Avenue and
the North Lange Avenue/Producer Avenue to provide a minimum offset of 125-
feet (measured from centerline to centerline).
10. Construct:
North Cinema Way (from Chinden Boulevard to West Director
Street),
West Director Street (from Meridian Road to North Cinema Way),
West Producer Street (from Meridian Road to North Mitchum
Avenue),
West Studio Drive (from Meridian Road to McMillan Road) and
West Paramount Drive (from Linder Road to North Arliss Avenue)
as 40-foot street sections with vertical curb, gutter and 5-foot attached concrete
sidewalk within 54-feet of right-of-way.
11. Construct:
West Paramount Drive (from North Arliss Avenue to North
Cinema Way),
North Bergman Avenue (from West Paramount Drive to the north
property line),
North Cinema Way (from West Director Street to West Colbert
Street),
North Chaplin Drive (from North Cinema Way to North Cinema
Way),
West Gable Street (from North Cinema Way to West Producer
Street) and
West Producer Street (from North Mitchum Avenue to North
Hopkins Avenue)
as 36-foot street sections with rolled curb, gutter and 5-foot attached concrete
sidewalk, as proposed.
12. Construct the remainder of the internal roadways as 33-foot street sections
with curb, gutter, 5-foot attached concrete sidewalk and parking on both sides of
the roadway within 50-feet of right-of-way, as proposed. Submit documentation
showing the review and approval from the Meridian Fire Department.
13. Extend North Wayman Avenue as a stub street to the south property line
approximately 1,900-feet west of Meridian Road, as proposed. Install a sign at
the terminus of the roadway stating that, "THIS ROAD WILL BE EXTENDED
IN THE FUTURE".
14. Extend North Cinema Way as a stub street to the south property line
approximately 2,050-feet east of Linder Road, as proposed. Install a sign at the
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 6
terminus of the roadway stating that, "THIS ROAD WILL BE EXTENDED IN
THE FUTURE".
15. Extend North Bergman Avenue as a stub street to the north property line
approximately 1,220-feet east of Linder Road, as proposed. Install a sign at the
terminus of the roadway stating that, "THIS ROAD WILL BE EXTENDED IN
THE FUTURE". ***See Finding for Consideration B item #7.
16. Extend North Arliss Avenue as a stub street to the north property line
approximately 820-feet east of Linder Road, as proposed. Install a sign at the
terminus of the roadway stating that, "THIS ROAD WILL BE EXTENDED IN
THE FUTURE".
17. Provide access to West Producer Street (by a stub street or by shifting the
roadway to the north) for the undeveloped parcels located directly to the north
(the Packard and Mastropaolo properties).
18. Construct a 16-foot wide residential alley between West Oliver Street and
West Peck Street and West Studio Drive and West Producer Street, as proposed.
Improve the alley its full width and provide a minimum of back-of-curb radius of
15-feet at all alley intersections. Parking shall be designed so the minimum clear
distance from the back of the parking stall to the opposite side of the alley is 22-
feet for perpendicular parking. Any access to an alley shall be located a minimum
of 25-feet from the nearest public street. Parking in the alley is prohibited.
19. Construct a 16-foot wide residential alley between West Poitier Street and
West Peck Street and West Studio Drive and West Producer Street, as proposed.
Iimprove the alley its full width and provide a minimum of back-of-curb radius of
15-feet at all alley intersections. Parking shall be designed so the minimum clear
distance from the back of the parking stall to the opposite side of the alley is 22-
feet for perpendicular parking. An access to an alley shall be located a minimum
of 25-feet from the nearest public street. Parking in the alley is prohibited.
20. Construct three roundabouts within the public right-of-way, as proposed.
On West Director Street (mid way between Meridian Road and
North Cinema Way)
At the intersection of Chaplin Street and North Dietrich Avenue
At the intersection of Cagney Street and North Dietrich Avenue
The roundabouts shall be designed with a minimum of a 21-foot street section on
either side of the center islands. The applicant will be required to dedicate
sufficient right-of-way on either side of an island. Coordinate the size and design
of the roundabouts with traffic services staff.
21. Do not construct a roundabout at the intersection of North Bergman
Avenue and Bacall Street unless a temporary turnaround is constructed at the
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 7
terminus of North Bergman Avenue or North Bergman Avenue will be extended
at the time that this portion of the preliminary plat is final platted.
22. Construct one knuckle with an island in the center, as proposed. Construct
the island to be a minimum of 4-feet wide with a minimum area of 100-square
feet and designed to safely channel traffic. The roadway around the traffic island
shall maintain a minimum of a 29-foot street section. The design shall be
reviewed and approved by ACHD's Traffic Services staff.
23. When the District receives a formal application for the multi-family use
and/or the commercial use, the District will review and approve driveway
locations in accordance with the policies and guidelines that are in effect at that
time. The District’s current policies are provided for informational purposes only
and can be found in Findings for Consideration #9 on pages 13 and 14 of this
report.
24. Construct a number of islands within the public right-of-way, as proposed.
Maintain minimum of a 21-foot street section on either side of the center islands.
Any proposed landscape islands/medians within the public right-of-way dedicated
by this plat shall be owned and maintained by a homeowners association. Notes
of this shall be required on the final plat
25. Construct a southbound left turn lane on Linder Road at the West
Paramount Drive/Linder Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
26. Construct a northbound right turn lane on Linder Road at the West
Paramount Drive/Linder Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 8
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
27. Construct an eastbound left turn lane on McMillan Road at the West
Studio Drive/McMillan Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
28. Construct a westbound right turn lane on McMillan Road at the West
Studio Drive/McMillan Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
29. Construct a northbound left turn lane on Meridian Road at the West Studio
Drive/Meridian Road intersection, as recommended by the submitted traffic
impact study. Prior to submittal of the final plat for the 201st residential lot, or the
platting of the first non-residential lot, whichever comes first, ACHD staff shall
determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 9
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
30. Construct a southbound right turn lane on Meridian Road at the West
Studio Drive/Meridian Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
31. Construct a northbound left turn lane on Meridian Road at the West
Producer Street/Meridian Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
32. Construct a southbound right turn lane on Meridian Road at the West
Producer Street/Meridian Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 10
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
33. Construct a northbound left turn lane on Meridian Road at the West
Director Street/Meridian Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
34. Construct a southbound right turn lane on Meridian Road at the West
Director Street/Meridian Road intersection, as recommended by the submitted
traffic impact study. Prior to submittal of the final plat for the 201st residential lot,
or the platting of the first non-residential lot, whichever comes first, ACHD staff
shall determine the need for additional turn lane analysis to be provided by the
applicant. As requested by ACHD, the applicant’s traffic engineer shall submit a
traffic analysis, which analyzes the need for auxiliary lanes on the arterial
roadways. The analysis should include all prior platted lots, and those included to
be platted with that phase. The traffic engineer shall evaluate warrants based on
District policy in effect at that time of submittal of the turn lane analysis. Staff
encourages the applicant to submit the turn lane analysis PRIOR to submittal of
the final plat, so that the platting process is not delayed, or major revisions
required. Further analysis may be required with each additional final plat, as
determined by ACHD staff, to make certain the turn lanes are constructed as
needed.
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 11
35. Construct a westbound right turn lane on West Studio Drive at the West
Studio Drive/McMillan Road intersection, as recommended by the submitted
traffic impact study.
36. Construct an exclusive eastbound left turn lane on West Studio Drive at
the West Studio Drive/McMillan Road intersection, as recommended by the
submitted traffic impact study.
37. Construct an exclusive northbound left turn lane on West Studio Drive at
the West Studio Drive/Meridian Road intersection, as recommended by the
submitted traffic impact study.
38. Construct an exclusive southbound right turn lane on West Studio Drive at
the West Studio Drive/Meridian Road intersection, as recommended by the
submitted traffic impact study.
39. Construct an exclusive northbound left turn lane on West Producer Street
at the West Producer Street/Meridian Road intersection, as recommended by the
submitted traffic impact study.
40. Construct an exclusive southbound right turn lane on West Producer Street
at the West Producer Street/Meridian Road intersection, as recommended by the
submitted traffic impact study.
41. Construct an exclusive northbound left turn lane on West Director Drive at
the West Director Drive/Meridian Road intersection, as recommended by the
submitted traffic impact study.
42. Construct an exclusive southbound right turn lane on West Director Drive
at the West Director Drive/Meridian Road intersection, as recommended by the
submitted traffic impact study.
43. Construct an exclusive northbound right turn lane on West Paramount
Drive at the West Paramount Drive/Linder Road intersection, as recommended by
the submitted traffic impact study.
44. Construct a combined through/southbound left turn lane on West
Paramount Drive at the West Paramount Drive/Linder Road intersection, as
recommended by the submitted traffic impact study.
45. Submit District a letter from ITD regarding the said requirements prior to
District approval of the final plat or issuance of a building permit (or other
required permits), whichever occurs first.
46. Other than the access points specifically approved with this application,
direct lot access to Meridian Road, Linder Road and McMillan Road is prohibited
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 12
unless otherwise approved by the Ada County Highway District. These
restrictions shall be noted on the final plat.
47. Comply with all Standard Conditions of Approval.
Standard Conditions of Approval
1. Any existing irrigation facilities shall be relocated outside of the right-of-
way.
2. All utility relocation costs associated with improving street frontages
abutting the site shall be borne by the developer.
3. Replace any existing damaged curb, gutter and sidewalk and any that may
be damaged during the construction of the proposed development. Contact
Construction Services at 387-6280 (with file number) for details.
4. Utility street cuts in pavement less than five years old are not allowed
unless approved in writing by the District. Contact Construction Services at 387-
6280 (with file numbers) for details.
5. All design and construction shall be in accordance with the Ada County
Highway District Policy Manual, ISPWC Standards and approved supplements,
Construction Services procedures and all applicable ACHD Ordinances unless
specifically waived herein. An engineer registered in the State of Idaho shall
prepare and certify all improvement plans.
6. The applicant shall submit revised plans for staff approval, prior to
issuance of building permit (or other required permits), which incorporates any
required design changes.
7. Construction, use and property development shall be in conformance with
all applicable requirements of the Ada County Highway District prior to District
approval for occupancy.
8. Payment of applicable road impact fees are required prior to building
construction in accordance with Ordinance #197, also known as Ada County
Highway District Road Impact Fee Ordinance.
9. It is the responsibility of the applicant to verify all existing utilities within
the right-of-way. Existing utilities damaged by the applicant shall be repaired by
the applicant at no cost to ACHD. The applicant shall be required to call
DIGLINE (1-800-342-1585) at least two full business days prior to breaking
ground within ACHD right-of-way. The applicant shall contact ACHD Traffic
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 13
Operations 387-6190 in the event any ACHD conduits (spare or filled) are
compromised during any phase of construction.
10. No change in the terms and conditions of this approval shall be valid
unless they are in writing and signed by the applicant or the applicant’s
authorized representative and an authorized representative of the Ada County
Highway District. The burden shall be upon the applicant to obtain written
confirmation of any change from the Ada County Highway District.
11. Any change by the applicant in the planned use of the property which is
the subject of this application, shall require the applicant to comply with all rules,
regulations, ordinances, plans, or other regulatory and legal restrictions in force at
the time the applicant or its successors in interest advises the Highway District of
its intent to change the planned use of the subject property unless a
waiver/variance of said requirements or other legal relief is granted pursuant to
the law in effect at the time the change in use is sought.
C. Adopt the Recommendations of the Meridian Fire Department as follows:
1. The project which comprised of single family dwellings will require a fire-
flow of 1,000 gallons per minute available for duration of 2 hours to service the entire
project. Fire hydrants shall be placed an average of 400’ apart. 1997 UFC Appendix
III-A
2. Acceptance of the water supply for fire protection will be by the Meridian
Water Department.
3. Final Approval of the fire hydrant locations shall be by the Meridian Fire
Department. The proposed fire hydrant locations will be submitted to the Public
Works for plan review.
4. All roads and fire lanes shall have a turning radius of 28’ inside and 48’
outside.
5. Operational fire hydrants and temporary or permanent street signs are required
before combustible construction begins. UFC 901.4.2 & 901.3
6. Two points of access will be required for the project or portions of the project
that serve over 50 homes. This will be a concern the way the project is phased in the
early stages of development.
7. Commercial and office occupancies will require a fire-flow consistent
with the Uniform Fire Code to service the proposed project. Fire hydrants shall
be placed an average of 400’ apart. 1997 UFC Appendix III-A
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 14
8. Multi-family residential on the site will require a fire-flow of 1500 GPM
plus the amount required by the fire sprinkler demand.
9. All access roads within the project shall have a clear driving surface with a
minimum
width of 20’ available at all times. Restricted parking on some streets and access
points to fire lanes may be required to maintain a clear emergency access which is
20’ wide. UFC 902.2.2.1
10. The phasing plan may require that any roadway greater than 150’ in length
that is not provided with an outlet shall be required to have a approved turn
around.
11. The proposed 1107 unit subdivision with an estimated 2.9 residents per
household would have a total estimated population of 3,210 residents at build out.
This will generate an estimated 133 calls for service based on historical trends.
The commercial, schools and churches will have an unknown transient population
and will have an unknown impact on Meridian Fire Department call volumes.
The Meridian Fire Department has experienced 2069 responses in the year 2000
and 2251 calls for service in 2001. According to a report completed by Fire &
Emergency Services Consulting Group in February of 2000 our requests for
service are projected to reach 2800 in the year 2005 and 3800 by the year 2010.
12. The proposed project lies on the edge of the five-minute response zone
goal. Achievement of this goal is subject to budgetary constraints and is intended
to enhance the probability of a favorable outcome on a request for Basic Life
Support. The budget constraints are typically defined as capital outlay for
facilities that are located within 1.5 miles from a given location and sufficient
operational funds to staff the facilities.
13. It is requested that building separations be maintained per the Building
Code in Blocks 32, 33, 34, 35,30, 31, 36, 37 to reduce the possibility of fires
being transmitted from house to house.
D. Adopt the Recommendations of Settlers’ Irrigation District as follows:
1. That all irrigation/drainage facilities along with their easements be
protected and continue to function as such. The laterals involved are the
North Slough #2, North Slough, Knight, Lemp, Harrell, Wolf, and Bisby.
2. A license agreements will need to be signed and recorded prior to
construction of any irrigation facilities.
3. All Storm drainage must be retained on-site.
RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF ANNEXATION & ZONING FOR
PARAMOUNT SUBDIVISION BY PARAMOUNT, LLC – AZ-03-006 - Page 15
4. Any changes to the existing irrigation system must be approved by
Settlers Irrigation District.
5. The development must supply irrigation access to all lots within the
above-mentioned
subdivision. If the developer
wishes to have Settlers Irrigation
District own, operate, and maintain
the pressure irrigation system and
agreements needs to be in
place prior to the pre-construction