Loading...
HomeMy WebLinkAboutStaff CommentsCITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT STAFF REPORT: Meeting Date: February 19, 2008 E IDIAN~-- TO: Mayor and City Council i b A H o FROM: Jenny Veatch, Assistant City Planner ~~ ~ ~ '`~ 208-884-5533 Scott Steckline, Development Services Coordinator FEB 1 J ZQQ~i 208-898-5500 City Of Meridiaai SUBJECT: Paramount Commercial Southwest Subdivision City Clerk Office Request for Final Plat Approval of Paramount Commercial Southwest Subdivision Consisting of 4 Commercial Building Lots on 3.77 Acres in a C-G Zoning District by Brighton Corporation (File# FP-08-001). We have reviewed this submittal and offer the following comments and conditions of the applicant. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, Brighton Corporation, has applied for fmal plat approval of 4 commercial building lots on 3.77 acres of land for Paramount Commercial Southwest Subdivision. The zoning district for the proposed subdivision is C-G (General Retail and Service Commercial District). Paramount Commercial Southwest Subdivision is located on the northeast corner of N. Linder Road and W. McMillan Road in Section 25, T. 4N., R. 1 W. This property was previously annexed and was part of the preliminary plat of Paramount Subdivision (Lot 57, Block 3). The City Council approved the preliminary plat for Paramount Commercial Southwest Subdivision on September 25, 2007. The submitted final plat substantially complies with the approved preliminary plat. Staff recommends approval of Paramount Commercial Southwest Subdivision with the comments and conditions stated in this report. SITE SPECIFIC CONDITIONS 1. Applicant is to meet all terms of the approved Paramount development agreement (instrument # 103137116), annexation (AZ-03-006), preliminary plat (PP-03-004), and conditional use permit (CUP-03-008) and approved Paramount Commercial Southwest modified development agreement (instrument # 107145935) and preliminary plat (PP-07-011) applications for this subdivision. 2. If the City Engineer's signature has not been obtained by 09/25/09, the Final Plat approval for this subject phase shall expire. 3. Prior to submittal for the City Engineer's signature, have the Certificate of Owners and the accompanying acknowledgement signed and notarized. 4. Revise the face of the plat to label the landscape buffer along N. Linder Road, W. McMillan Road and the east property boundary as "landscape buffers" and not as easements. FP-08-001 Pazamount Commercial Southwest Subdivision F'P.doc PAGE CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT Revise the face of the plat to call out the sidewalk and associated easement along Lot 1 on W. McMillan Road. 6. Revise the face of the plat to label all easements buffers and graphically depict the widths of the easements. Revise or add the following note(s) on the face of the plat prepared by Mason & Stanfield, Inc., stamped on 12/10/07 by Darin Holzhey, prior to signature of the final plat by the City Engineer: 2.) Revise note, "This plat is subject to the development agreements recorded as instrument numbers 107145935 and 103137116 of Ada County Records." 7.) Revise note, "Lots 1-4, Block 1 are subject to a permanent ingress/egress ~~aon *~°wa:.,.. ~~~~-~~ ° ° ^a ~°*°~ °~* and cross-access parking easement as shown. *.) Add a note, "Lots 1-4, Block 1 are subject to a City of Meridian sanitary sewer and water easement as shown." *.) Add a note addressing the maintenance responsibilities of the landscape buffers adjacent to N. Linder Road, W. McMillan Road and the east property boundary. *.) Add a note, "The bottom elevation of building footings shall be set a minimum of 12 inches above the highest known normal ground water elevation." 8. Prior to signature of the final plat by the City Engineer, all existing structures shall be removed or relocated from the site. All fencing installed on the site must be in compliance with UDC 11-3A-6 and 11-3A-7, and as proposed on the landscape plan. Temporary construction fencing to contain debris shall be installed at the subdivision boundary where permanent fencing does not exist. Perimeter fencing shall be installed on the east side prior to release of building permits for this subdivision. 10. The landscape plan, prepared by The Land Group, and dated 12/10/07 is approved with the following changes: a. Substitute an Amur Maple or Flame Maple for the proposed Red Sunset Maple. The proposed tree is not heat tolerant and is subject to decay per the Boise Urban Foresty Tree Selection Guide, and is prohibited by the standards set forth in UDC 11-3B-SC. b. Unless otherwise approved with an alternative compliance application, construct a 25- foot wide landscape buffer constructed per UDC 11-3B-8 on N. Linder Road. The landscape buffers adjacent to N. Linder Road, W. McMillan Road and the east property boundary are subdivision improvements and shall be installed prior to occupancy of the first building. The internal landscaping for the individual lots buildings and parking areas not approved with this final plat, they will be reviewed with each individual CZC. Submit three copies of a revised landscape plan to the Planning Department prior to signature of the final plat by the City Engineer. Said plan shall be consistent with the changes listed above. 11. Prior to signature of the final plat by the City Engineer, the applicant shall provide a letter from the United States Postal Service stating that the applicant has received approval for the location of mailboxes. Contact the Meridian Postmaster, Richard Buttrarn, at 887-1620 for more information. FP-08-001 Paramount Commercial Southwest Subdivision FP.doc PAGE CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTME 12. NTS STAFF REPORT All areas approved 13 GENERAL >f2EQU~MENTS 1 • Per UDC 11-3A-6 all irrigation ditches, laterals or canals, excl intersect, cross or lie within the area being subdivided shall be covere ustve of natural waterways, that approved by the appropriate imgation/draina a d• Plans will need to be owners), with written approval or non-a g district, or lateral users association pproval submitted to the Public Works Department to plan approval. If lateral users association approval can not be obtained al (ditch reviewed and approved by the City Engineer. ternate plans w P be 2• Street si ' gns are to be in place, water system shall be approved and activated, fencin i sewer line shall be installed and passed air test and video inspection, final Tat r base shall be approved prior to a g nstalled, pplying for building permits. p ecorded and road 3• A letter of credit or cash surety in the amount of 110% shall fencing, landscaping, amenities, pressurized be required for all uncompleted signature on the final plat. irrigation, sanitary sewer, water, etc. prior to 4• All development improvements, including but not limited to wat pressurized irrigation and landscaping shall be installed and a certificates of occu anc er, sewer, fencing, micro-paths, P Y, or as otherwise allowed b Pproved prior to obtaining Y UDC 11-SC-1. 5• A written certificate of completion shall be prepared b designer or qualified nurseryman responsible for the landscapelalancupe arc~tect, landscape landscape installation. The Certificate of p Pon completion of the improvements, includin Completion shall veri with the a g Plant materials and sprinkler installation, are in Substantiall co plianpe Pproved landscape plan. 6• The applicant shall provide a 20-foot easement for all public wa right of way (include all water services and h ter/sewer mains outside of public the plat, but rather dedicated outside the plat process using the Cit of M • The easements shall not be dedicated via The easement shall be tn'ap~call Y endian's standard forms. executed casement (on the form avai ablecfrom Pu 1 c pWorks), a Terence include the area of the easement (marked EXHIBIT A) and an 81/2" x 11" poses. Submit an distances (marked EXHIBIT B gal description, which must Professional Land S )for review. Both exhibits must be sealed, map with bearings and document. urveyor. DO NOT REC01Zp Add a note to the plat dreferencind by a g this ~• Applicant shall be required to a inspection fees, as dete p Y Public Works develo rmined during the plan review proces prio ~ oani review, and construction gnature on the final plat. FP-08-001 Paramount Commercial Southwest Subdivision FP.doc stormvwater detention fa olhes incorporated into the ap roved 3B-11 and shall be fully vegetated with p°nds or other such nuisances. All P open space are subject to UDC 11- surface materials shall not be used in open ace lots, exce Sas de If the stormwater detention facility cannot be incorporated int ~ gravel or other non-vegetated meet the standards of p p rnutted under UDC 11-3$-11. UDC 11-3B-11, then the a o the approved open space and still require losing a developable lot or developab elicareaShItl islothee the facilit . developer to comply with AC Y TES may time of final construction. ~' City of Meridian and all other regulato esponsibility of the ry requirements at the Staff's failure to cite specific ordinance provisions or conditions from t not relieve the Applicant of responsibility for compliance. he preliminary plat does PAGE 8. 10 11 12 13. 14. 15 16. 17 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTM Compaction test results must be submitted to the Meridian Buil E N T S STAFF R E P O R T pads receiving engineered backfill, where footing would sit atop fill material. ding Department for all building Applicant shall be responsible for application and compliance with an S that may be required by the Army Corps of Engineers. y ection 404 Permitting Applicant shall be responsible for application and compliance with and may be required by the Environmental Protection Agency. NPDES Permitting that All development features shall comply with the Americans with Disabi • ' Housing Act. litres Act and the Fair Any tree over 4" in caliper that is removed from the ro ert additional trees, being the equivalent number of caliperpncheshof tr ereplaced by installing Required landscaping trees will not be considered as replacement trees for be removed. s that were removed. those trees that have to Any existing domestic well system within this project shall be removed fr City Ordinance Section 9-1-4 and 9-4-8 contact the City of Meridian E ' (208)898-5500 for inspections of disconnection of services. Wells °m domestic service per Purposes such as landscape irrigation if a ngineering Department at may be used for non-domestic Contact Robert B. Whitney at (208)334-2190 proved by Idaho Department of Water Resources Any existing septic systems within this project shall be removed from servi Section 9=1-4 and 9-4-8. Contact Central District Health for abando inspections (208)375-5211. Ce per City Ordinance nment procedures and The engineer shall be required to certi 3-feet above the highest established eakthat the street centerline elevations are set a P groundwater elevation. This is to ensure that the bo tom e evation of the crawl spaces of homes is at least 1-foot above. The applicants design engineer shall be responsible for inspection of all ' ' facility within this project that do not fall under the ' ACRD. ~gation and/or drainage The design engineer shall provide certification thatl the facilities haver bee istrict or the accordance with the approved design plans. This certification will be required b of occupancy is issued for an n installed in y structures within the proiect efore a certificate At the completion of the project, the a per the Cit of pplicant shall be responsible to submit record drawings Y Meridian AutoCAD standards. approved prior to the issuance of a certification of oc uoancdrawings must be received and project. P y for any structures within the STAFF RECOI~ENDATION Staff recommends approval of the final plat for Paramount Comm (FP-08-001) with the above stated comments and conditions. ercial Southwest Subdivision FP-08-001 Paramount Commercial Southwest Subdivision FP.doc PAGE