HomeMy WebLinkAboutFire Department CommentsMAYOR
ROBERT D. CORRffi
COUNCa MEMBERS
WB.LIAM L.M. NARY
KBrrx BBCD
TAMMY DE WEERD
CraRaMcCArmLBSs
RURAL FmE COMMISSIONERS
RICHARD GREENS
TERRY LEIOHTON
STEVE ELLIOTT
CIF
KEN W. BOWERS
DEPUTY CHIEF - FmE PREVENTION
JOSEPH SII.VA
DEPO'I'Y CHBiF -TRAINING
BaLJOHNSON
540 East Franklin Road
Meridian, ID 83642
(208)888-1234
Fax (208)895-0390
MERIDIAN CITY/RURAL FIRE DEPARTMENT
-..___ ___R~CEISVED_
March 18, 2003
MAR 1 8 [003
City Of Meridian
City Clerk Office
TO: Mayor, City Council and Meridian Planning & Zoning Commission
FROM: Joseph Silva, Deputy Chief:, Fire Prevention
SUBJECT: Northbridge Subdivision MI 02-013
The following will be the requirements and/or conceive to provide minimum levels of fire
protection for the proposed project:
1. The phasing plan may require that any roadway greater than 150' in length
that is not provided with an outlet shall be required to have a tum azound.
2, All roads shall have a turning radius of 28' inside and 48' outside.
3. A minimum of two points of access will be required for any portion of the project,
which serves more than 50 homes. UFC 902.2.1
4. The roadways shall be built to Ada County Highway Standards and shall have a
clear driving surface, available at all times, which is 20' wide. UFC 902.2
5. With the size of the project it would be preferred to have multiple points of access in
order to provide assurance that at least one access pout will be available to
emergency services. UFC 902.2.1
MAYOR (;HiEF
RoeaRrD. CoRRrE KEN W. BOWERS
COUNCIL MEMBERS f DEPUTYGRIEF -FIRE PREVENTION
WB.LUM L.M. NARY
. ^ JOSEPH Sn,VA
KErrH BmD . DEPUTY CHIEF -TRAINING
TAMMY DE WEERD
CREATE MCCANDLESS ._
CyITyY O/fFy
~
I ~ ~ ~ BB,L JOHNSON
RURAL FIRE CoMM[SSioNERS '~+~ r /- V / G L/L
16
u~nr-~a ~ 540 Fast Franklin Road
RICHARD GREENE ~~, ~if Meridian, l.D 83642
TeaxY Le[aHTON ~~~
Y (20R) 888-1234
SrevE ELUOTT u'-'~"=? ~~~~"^-`-r
`
e F~Lx (208) 895-0390
a
u
a
MERIDIAN CITY/RURAL FIRE DEPARTMENT
FEB 1 1.2003
Februazy 10, 2003 CITY OF MERIDIAN
CITY CLERK OFFfCF
TO: Mayor, City Council and the Meridian Planning & Zoning Commission
FROM: Joseph Silva, Deputy Chief, Fire Prevention
SUBJECT: Northbridge Subdivision AZ 02-032, MI 02-013, PP 02-035
The following will be the requirements and/or concerns to provide minimum levels of fire
'protection for the proposed project:
1. The project which comprised of one and two family dwellings will require afire-flow of
1,000 gallons per minute available for duration of 2 hours to service the entire project.
Fire hydrants shall be placed an average of 400' apart. 1997 UFC Appendix III-A
2. Acceptance of the water supply for fire protection will be by the Meridian
Water Department.
3. Final Approval of the fire hydrant locations shall be by the Meridian Fire
Department. The proposed fire hydrant locations will be submitted to the Public
Works for plan review.
4. All roads and fire lanes shall have a turning radius of 28' inside and 48' outside.
5. Insure that all yet undeveloped parcels are maintained free of combustible vegetation
per section 1103.2.4 of the Uniform Fire Code.
6. All access roads within the project shall have a clear driving surface with a minimum
width of 20' available at all times. The typical street width of 34' will be allowed to
have parking on both sides. The typical street with a m;n;mum width of 29' will be
required to have restricted parking to only one side. UFC 902.2.2.1
Operational fire hydrants and temporary or permanent street signs aze required before
combustible construction begins. UFC 901.4.2 & 901.3