Loading...
HomeMy WebLinkAboutFire Department CommentsMAYOR ROBERT D. CORRffi COUNCa MEMBERS WB.LIAM L.M. NARY KBrrx BBCD TAMMY DE WEERD CraRaMcCArmLBSs RURAL FmE COMMISSIONERS RICHARD GREENS TERRY LEIOHTON STEVE ELLIOTT CIF KEN W. BOWERS DEPUTY CHIEF - FmE PREVENTION JOSEPH SII.VA DEPO'I'Y CHBiF -TRAINING BaLJOHNSON 540 East Franklin Road Meridian, ID 83642 (208)888-1234 Fax (208)895-0390 MERIDIAN CITY/RURAL FIRE DEPARTMENT -..___ ___R~CEISVED_ March 18, 2003 MAR 1 8 [003 City Of Meridian City Clerk Office TO: Mayor, City Council and Meridian Planning & Zoning Commission FROM: Joseph Silva, Deputy Chief:, Fire Prevention SUBJECT: Northbridge Subdivision MI 02-013 The following will be the requirements and/or conceive to provide minimum levels of fire protection for the proposed project: 1. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have a tum azound. 2, All roads shall have a turning radius of 28' inside and 48' outside. 3. A minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. UFC 902.2.1 4. The roadways shall be built to Ada County Highway Standards and shall have a clear driving surface, available at all times, which is 20' wide. UFC 902.2 5. With the size of the project it would be preferred to have multiple points of access in order to provide assurance that at least one access pout will be available to emergency services. UFC 902.2.1 MAYOR (;HiEF RoeaRrD. CoRRrE KEN W. BOWERS COUNCIL MEMBERS f DEPUTYGRIEF -FIRE PREVENTION WB.LUM L.M. NARY . ^ JOSEPH Sn,VA KErrH BmD . DEPUTY CHIEF -TRAINING TAMMY DE WEERD CREATE MCCANDLESS ._ CyITyY O/fFy ~ I ~ ~ ~ BB,L JOHNSON RURAL FIRE CoMM[SSioNERS '~+~ r /- V / G L/L 16 u~nr-~a ~ 540 Fast Franklin Road RICHARD GREENE ~~, ~if Meridian, l.D 83642 TeaxY Le[aHTON ~~~ Y (20R) 888-1234 SrevE ELUOTT u'-'~"=? ~~~~"^-`-r ` e F~Lx (208) 895-0390 a u a MERIDIAN CITY/RURAL FIRE DEPARTMENT FEB 1 1.2003 Februazy 10, 2003 CITY OF MERIDIAN CITY CLERK OFFfCF TO: Mayor, City Council and the Meridian Planning & Zoning Commission FROM: Joseph Silva, Deputy Chief, Fire Prevention SUBJECT: Northbridge Subdivision AZ 02-032, MI 02-013, PP 02-035 The following will be the requirements and/or concerns to provide minimum levels of fire 'protection for the proposed project: 1. The project which comprised of one and two family dwellings will require afire-flow of 1,000 gallons per minute available for duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. 1997 UFC Appendix III-A 2. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 3. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. The proposed fire hydrant locations will be submitted to the Public Works for plan review. 4. All roads and fire lanes shall have a turning radius of 28' inside and 48' outside. 5. Insure that all yet undeveloped parcels are maintained free of combustible vegetation per section 1103.2.4 of the Uniform Fire Code. 6. All access roads within the project shall have a clear driving surface with a minimum width of 20' available at all times. The typical street width of 34' will be allowed to have parking on both sides. The typical street with a m;n;mum width of 29' will be required to have restricted parking to only one side. UFC 902.2.2.1 Operational fire hydrants and temporary or permanent street signs aze required before combustible construction begins. UFC 901.4.2 & 901.3