Loading...
HomeMy WebLinkAboutFire Department CommentsPage 1 of 1 Machelle Hill From: Kristy Vigil Sent: Tuesday, September 18, 2007 2:01 PM To: Tara Green; Machelle Hill; Nancy Radford; Sharon Smith Subject: FW: Comments Baraya Subdivision #2 FP 07-031 For your file and packets. Thank you, KV From: Joe Silva Sent: Tuesday, September 18, 2007 2:00 PM To: Kristy Vigil; Jennifer Veatch; Sonya Watters Subject: RE: Comments Baraya Subdivision #2 FP 07-031 To increase emergency access to the site a minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. The two entrances should be separated by no less than % the diagonal measurement of the full development. The applicant shall provide a stub street to the property or a emergency vehicle access point to the project. Joseph Silva Fire Marshal Meridian Fire Department (208)888-1234 From: Joe Silva Sent: Tuesday, September 18, 2007 1:48 PM To: Kristy Vigil; Jennifer Veatch; Sonya Watters Subject: Comments Baraya Subdivision #1 FP 07-030 W. Peekaboo Ct. Lots 15, 16, 17 & 18 All portions of the buildings located on this project must be within 15.0' of a paved surface as measured around the perimeter of the building. Driveways shall be straight or have a turning radius of 28' inside and 48' outside and shall have a clear driving surface which is 20' wide and support an imposed weight of 75,000 GVW. Any driveway greater than 150 feet in length that is not provided with an outlet shall be required to have an approved turn around. Joseph Silva Fire Marshal Meridian Fire Department (208) 888-1234 9/18/2007