RECEIVED
Date: October 25, 2002 MAR 0 6 2003
City Of Meridian
City Clerk Office
To: Honorable Mayor, City Council & Meridian Planning & Zoning Commission
From: Joseph Silva, Deputy Fire Chief, Fire Prevention
Subject: Moshers Farm Subdivision FP 03-011
The following will be the requirements and/or concerns to provide minimum levels of fire
protection for the proposed project:
1. One and two family dwellings will require afire-flow of 1,000 gallons per
minute available for duration of 2 hours to service the entire project. Fire
hydranss shall be placed an average of 400' apart. 1997 UFC Appendix III-A
2. Acceptance of the water supply for fire protection will be by the Meridian
water Department.
3. Final Approval of the fire hydrant locations shall be by the Meridian Fire.
Department.
4. All roads shall have a turning radius of 28' inside and 48' outside.
i
5. All access roads within tbe project shall have a clear driving surface with a
minimum width of 20' available at all times. UFC 902.2.2.1
6. Operational fire hydrants and temporuy or permanent street signs are
required before combustible construction begins. UFC 901.4.2 & 901.3
7. It is recommended that no parking be allowed in from of Block 1 Lots # 9,
10, 11, 12, 13, 14, 15, 23, 26, 27 to prevent blocking of the fire lane.
8. It is requested that the nose of the island (Block 2 Lot 1) be moved 15' West
to prevent the trailing axles of fire apparatrrs from clipping the curb.