HomeMy WebLinkAboutRetail 1 UTILITY PLAN / i , (:Pb STAMP: 8"W 8"W 8"W 8"W— 8"W 8"W 8"W 8" can RESERVED FOR CITY APPROVAL STAMP / W e GENERAL NOTES ASS\ NS "C/ 1. ALL EXISTING UTILITY LOCATIONS SHOWN HEREIN ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING 1 7 1 5 v� I UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL ft 4/3 O/2 6p ACCESS ROAD c3 UTILITIES ARE SHOWN HEREON.THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR SSS SS SS SS SS SS JJ' SS SS SS SS W~ SS S I F UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. OF 2. ALL ABOVE GROUND UTILITY APPURTENANCES SHALL BE ADJUSTED TO MATCH PROPOSED FINISHED GRADE DON M DP ELEVATIONS. / Design Professional's electronic or digital seal or signature is effective only as to that version of 3. CONTRACTOR TO FIELD VERIFY EXISTING INVERT ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY THE this document as originally published by Design Professional.Design Professional is not responsible for any subsequent modification,corruption,or unauthorized use of such document. / ENGINEER OF ANY DISCREPANCIES. To verify the validity or applicability of the seal or signature,contact Design Professional. 4. PROJECT SHALL COMPLY WITH ALL IDAHO DIVISION OF DRINKING WATER RULES AND REGULATIONS INCLUDING, 23 LF @ 2.00% I I 1 BUT NOT LIMITED TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8 II W 5. PROJECT SHALL COMPLY WITH ALL CITY OF MERIDIAN SPECIFICATIONS AND REQUIREMENTS. GAS—CAI ks WIS ASc GAS—GAS S GAS GASL GAS GAS 6. ALL CONSTRUCTION IN THE CULINARY WATERLINE AND SANITARY SEWER LINE PIPE ZONE SHALL COMPLY WITH E E E E E — E E— E — l —E E E E / / T T T T T T T T T T T T T r TT ALL CITY OF MERIDIAN SPECIFICATIONS AND REQUIREMENTS. 2 / 22 LF OF 6"C900 ;;:TT _ N SEWER NOTES 22 LF OF 2"PvC 2 ~ I O FURNISH AND INSTALL 4" SANITARY SEWER LINE PER 2017 IDAHO STATE PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE DETAIL 5 ON SHEET C6.00. LENGTH AND SLOPE PER PLAN. 5 l r) CONNECT TO EXISTING SANITARY SEWER PER 2017 IDAHO STATE PLUMBING CODE / / m AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE DETAIL 9 ON SHEET 1 20LF@31.14% ~ HILLSIDE �- C6.00. CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL LOCATION AND NOTIFY ENGINEER IF THERE IS ANY CONFLICT PRIOR TO PROCEEDING. ARCHITECTURE / Q < FURNISH AND INSTALL 4" SANITARY SEWER CLEANOUT PER 2017 IDAHO STATE 0 I PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE LOT 8 / \ ~ m DETAIL 1 ON SHEET C6.00. INVERT PER PLAN. \ BLOCK 1 ® ¢ 41 LF OF 6"c9oo < FURNISH AND INSTALL 4"X4" WYE CONNECTION. E 45 LF OF 2"PVC 2 I O5 PROPOSED SANITARY SEWER BUILDING CONNECTION. STUB AND CAP WHITIN 5' OF fn PROPOSED BUILDING FOOTPRINT. INVERT PER PLAN. SEE PLUMBING PLANS FOR L C, �� / \ CONTINUATION. Oco O PROPOSED GREASE INTERCEPTOR. SEE MEP PLANS FOR CONTINUATION. N \ (n 00 CD 1 83 LF OF 4"PVC @ 2.50% M 5 O FURNISH AND INSTALL 3" PVC LINE FROM GREASE TRAP TO DRAIN WASTE VENT ^ N I I SYSTEM IN BUILDING. ^ o Z° J' I F \ \ I 8O PROPOSED GREASE INTERCEPTOR BUILDING CONNECTION. STUB AND CAP WHITIN 5 a ~ OF PROPOSED BUILDING FOOTPRINT. INVERT PER PLAN. SEE PLUMBING PLANS FOR \ Q CONTINUATION. oco _oo m O FURNISH AND INSTALL BEND PER 2017 IDAHO STATE PLUMBING CODE AND CITY OF .LO MERIDIAN STANDARDS AND SPECIFICATIONS. INVERT PER PLAN. m i Q I WATER NOTES m \ ~ O1 FURNISH AND INSTALL 2" WATER METER AND VALVE ASSEMBLY WITH 2" METER SETTER PER 2017 IDAHO STATE PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS TO CONNECT TO EXISTING WATER MAIN PER ISPWC AND CITY N OF MERIDIAN STANDARDS. SEE DETAIL 6 ON SHEET C6.10.000RDINATE WITH CITY OF ■ MERIDIAN FOR CONNECTION AND REMOVAL. nI \ O2 FURNISH AND INSTALL 2" SERVICE LINE PER 2017 IDAHO STATE PLUMBING CODE AND Q N CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. LENGTH PER PLAN. SEE DETAIL 5 ON SHEET C6.00. ¢ 8 LF F 6"C900 O3 PROPOSED DOMESTIC WATER ENTRY LOCATION. STUB AND CAB WITHIN 5' OF co 5 I I m PROPOSED BUILDING FOOTPRINT. SEE PLUMBING PLANS FOR CONTINUATION. co ~ I ® FURNISH AND INSTALL 6" C900 PVC PRIVATE FIRE WATER LINE LINE PER 2017 IDAHO W 7 N STATE PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. 4 � LENGTH PER PLAN. Q O O O5 FURNISH AND INSTALL 45° BEND WITH THRUST BLOCK PER ISPWC SD-403.SEE DETAIL J ~ 1 ON SHEET C6.10. � Q Q PROPOSED FIRE LINE ENTRY LOCATION. STUB AND CAB WITHIN 5' OF PROPOSED Q LOT 9 9 INV:2565.15 Q I BUILDING FOOTPRINT. SEE PLUMBING PLANS FOR CONTINUATION. J� BLOCK 1 � � � O O O FURNISH AND INSTALL 90° BEND WITH THRUST BLOCK PER ISPWC SD-403.SEE DETAIL LLJ M m 1 ON SHEET C6.10. Q NVA ~ J J J Z V I1N.Lj 111 x (w m ® FURNISH AND INSTALL 8" JURISDICTIONAL GATE AND 8" X 6" REDUCER PER CITY OF12 LF OF 4"PVC @ 2.50% 1 • MERIDIAN STANDARDS AND SPECIFICATIONS. Q (D — QO9 FURNISH AND INSTALL REMOTE FIRE DEPARTMENT CONNECTION WITH THREAD-ON Q INV:2565.46 ¢ r 1 m EXTERNAL STORZ ADAPTER WITH BLIND CAP. THRUSTBLOCKING PER DETAIL ON ■ 0 INV:2565.46 ~ � SHEET C6.02. Z - ' fflit STOP F--- LLILU 3 C 1 I DRY UTILITY NOTES 00 LLB G G m ° �— vl ¢ 142 LF OF 6"C900 I !!CAUTION!!I 5 LF OF 4"PVC @ 2.50% 1 1 34 LF OF 4"PVC @ 2.53% O1 ..CAUTION.. UTILITY CROSSING. VERIFY INVERTS PRIOR TO CONSTRUCTION. 10 1 I 2 PROPOSED ALIGNMENT OF POWER. SEE MEP PLANS FOR INFORMATION. �' J ol 141 LF OF 2"PVC 2 ¢ 107 LF OF 6"C9)0 O SS 6 I m "D PROPOSED GAS SERVICE ENTRY LOCATION. STUB AND CAP WITHIN 5' OF PROPOSED ~ I BUILDING FOOTPRINT. SEE MEP PLANS FOR CONTINUATION. PREPARED FOR: ® PROPOSED ALIGNMENT OF GAS SERVICE. COORDINATE WITH INTERMOUNTAIN GAS ON INSTALLATION. . AHLQUIST 9 INV:2566.33 00 PROPOSED TRANSFORMER LOCATION. CONNECT TO EXISTING ELECTRIC SERVICE 3 RIM:2569.88 LINE PROVIDE BY IDAHO POWER. SEE MEP PLANS FOR INFORMATION. 1 144 S SllverStone Way INV:2566.33 24 LF OF 4"PVC @ 2.25% 1 I © PROPOSED POWER SERVICE ENTRY LOCATION. STUB AND CAP WITHIN 5' OF Ste #500 Meridian, ID 83642 i 1 23LFOF4"PVC@2.51% TEN MILE DISTRICT RETAIL #1 � I PROPOSED BUILDING FOOTPRINT. SEE MEP PLANS FOR CONTINUATION. 7 5, 165 GROSS S.F. m O7 PROPOSED TELECOM/CATV ALIGNMENT. SEE MEP PLANS FOR DETAILS. BRAD SMITH 9 INV:2566.91 FFE:2570.00 ~ (208) 841-9449 INV:2566.55 1 2 LF OF 4"PVC @ 2.51% I 1 REVISIONS 9 INV:2566.95 I 1 1 2 LF OF 4"PVC @ 2.51% ~ No. Description Date 1 7 LF OF 4"PVC @ 2.25% 1 ADDENDUM 1 04/29/2026 5 INV:2567.00 INV:2566.71 9 8 INV:2567.21 RIM:2569.34 m INV:2566.71 3 LEGEND 22 LF OF 4"PVC @ 2.25% 1 Q ¢ 4 LF OF 6"C900 PROPERTY LINE I I I EXISTING WATER LINE 7 ¢ 2 LF OF 6"C900 ~19 LF OF 2"PVC 2 I W PROPOSED DOMESTIC WATER SERVICE LINE D 5 S S S EXISTING SANITARY SEWER LINE 12 LF OF 6"C900 ¢ • CAP SS SS PROPOSED SANITARY SEWER LINE N\\\\\\ 3 14 LF OF 6"C900 ¢ / GAS GAS GAS - EXISTING GAS LINE 2 X. 2 8 LF OF 2"PVC 7 �j 4 22 F OF 6"c9oo GAS GAS GAS PROPOSED GAS LINE 5 E EXISTING POWER LINE E D 82 LF OF 2"PVC E E PROPOSED POWER LINE Project No.: 193217011 (n ¢ 21 LF OF 6"C900 14 LF OF 6"C900 ¢ 1 1 u M M M M GP (,nM- - EXISTING TELECOM LINE Drawn By: PJS 15 LF OF 6"C900 ¢ M M M M M M M / 5 COM PROPOSED TELECOM LINE Reviewed By: BMD c�S 5 82 LF OF 6"C900 ¢ 83 LF OF 6 C900 ¢ S \ EXISTING PRESSURE IRRIGATION LINE Date: 2026-04-29 GAS GAS GAS G AS GAS GAS GAS GAS GP / ;wawr f1 I NORTH T 1� _ — �P - GRAPHIC SCALE IN FEET $PI 8"PI UGP _ — — ———— —— — — ———— ———— ———————————————————— ——————— - -- --- ---- -- 0 5 10 20 _ 8_PI- - d I d _ —° -M4J LTI-USE RAT H a --- a WAY 4 d 4 - - - � - - - - - - �a - - d Zrd d 4 d _ _ _ - - - - Q I 4 4 4 4 a l d d d I- 4 4 d d 4 I -- 4 d-- __ _ Q � W �r _ I r— d Q Q I� - - Q Q I I f y W WI , I IW W y W W W W `Y W W W W y �, f I I I UTILITY PLAN I W W I � � - - - - - - - - - - - - - - J i W W �Y W IWd I'�' i L _ — _ — _ — _ — _ J .�. W , — — — — � � I _ ��j L W W , - - - - - - ��r I � .y ' I I 1— — I ' W I I r I �Y / / Q a t ', W W y , t i W W W r r I I I I W W y I I I r — — — — — — — — — � i J, I /N■� / dQ ^ � Q tY►�y W W f t � _ — � f , W f 1 �- - I I W I I W W W `Y I I I I �' W F�71 W W Y W _ W. GRAND MOGUL DRIVE / 4 / � � 4 d /�/�,/ ', _ , � f �, 12"W 12"W C5 ,000 \I I IO Q T