HomeMy WebLinkAboutRetail 2 UTILITY PLAN GENERAL NOTES STAMP: I TONAL f RESERVED FOR CITY APPROVAL STAMP I I 1. ALL EXISTING UTILITY LOCATIONS SHOWN HEREIN ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S �SS�� NS NC/ RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING O UNDERGROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL UTILITIES ARE SHOWN HEREON.THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR W UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. 1 1 71 s 4/30/260 2. ALL ABOVE GROUND UTILITY APPURTENANCES SHALL BE ADJUSTED TO MATCH PROPOSED FINISHED GRADE ELEVATIONS. F OF \0 �v 3. CONTRACTOR TO FIELD VERIFY EXISTING INVERT ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY THE N00 M OPT\ t— — — — — — I ENGINEER OF ANY DISCREPANCIES. Design Professional's electronic or digital seal or signature is effective only as to that version of 4. PROJECT SHALL COMPLY WITH ALL IDAHO DIVISION OF DRINKING WATER RULES AND REGULATIONS INCLUDING, his document asysubsequentlly limodished by Designruption,or unaul. thorized Professionals not responsible for any subsequent modification,corruption,or unauthorized use of such document. BUT NOT LIMITED TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. To verify the validity or applicability of the seal or signature,contact Design Professional. 5. PROJECT SHALL COMPLY WITH ALL CITY OF MERIDIAN SPECIFICATIONS AND REQUIREMENTS. / 8 I I 6. ALL CONSTRUCTION IN THE CULINARY WATERLINE AND SANITARY SEWER LINE PIPE ZONE SHALL COMPLY WITH ALL CITY OF MERIDIAN SPECIFICATIONS AND REQUIREMENTS. 9 Q SEWER NOTES ❑ " 5 OFURNISH AND INSTALL 4" SANITARY SEWER LINE PER 2017 IDAHO STATE PLUMBING Un Ii / ILA CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE DETAIL 5 ON 3 I I SHEET C6.00. LENGTH AND SLOPE PER PLAN. 00 CONNECT TO EXISTING SANITARY SEWER PER 2017 IDAHO STATE PLUMBING CODE /`' "Now � I AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE DETAIL 9 ON SHEET T I C6.00. CONTRACTOR SHALL VERIFY HORIZONTAL AND VERTICAL LOCATION AND 140ow NOTIFY ENGINEER IF THERE IS ANY CONFLICT PRIOR TO PROCEEDING. N HILLSIDE Cf) / ^� < I O3 FURNISH AND INSTALL 4" SANITARY SEWER CLEANOUT PER 2017 IDAHO STATE ARCHITECTURE PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. SEE DETAIL 1 ON SHEET C6.00. INVERT PER PLAN. FURNISH AND INSTALL 4"X4" WYE CONNECTION. / / \ PROPOSED SANITARY SEWER BUILDING CONNECTION. STUB AND CAP WHITIN 5 OF cn �' ay / NVA I PROPOSED BUILDING FOOTPRINT. INVERT PER PLAN. SEE PLUMBING PLANS FOR I 2 I7 \ 00 CONTINUATION. CD / PROPOSED GREASE INTERCEPTOR. SEE MEP PLANS FOR CONTINUATION. � 0 CD o ❑ a LO O7 FURNISH AND INSTALL 3" PVC LINE FROM GREASE TRAP TO DRAIN WASTE VENT N ° 1 SYSTEM IN BUILDING. ' CD N I J) N OCONNECT TO 45A° VERTICAL BEND TO CONNECT TO EXISTING SEWER. SEE DETAIL 9 '/^�' o z° ON SHEET C6.00. 1 I 99 FURNISH AND INSTALL BEND PER 2017 IDAHO STATE PLUMBING CODE AND CITY OF N� o MERIDIAN STANDARDS AND SPECIFICATIONS. INVERT PER PLAN. 3: co 3 I I 10 PROPOSED GREASE INTERCEPTOR BUILDING CONNECTION. STUB AND CAP WHITIN 5' N 00 OF PROPOSED BUILDING FOOTPRINT. INVERT PER PLAN. SEE PLUMBING PLANS FOR m _ — CONTINUATION. 6 I j � I WATER NOTES I I c�i I I O1 FURNISH AND INSTALL 2" WATER METER AND VALVE ASSEMBLY WITH 2" METER ' SETTER PER 2017 IDAHO STATE PLUMBING CODE AND CITY OF MERIDIAN STANDARDS I I AND SPECIFICATIONS TO CONNECT TO EXISTING WATER MAIN PER ISPWC AND CITY 00TEN MILE DISTRICT RETAIL #2 OF MERIDIAN STANDARDS. SEE DETAIL 4 ON SHEET C6.10.000RDINATE WITH CITY OF / Q I I MERIDIAN FOR CONNECTION AND REMOVAL. 3 I / 8,207 GROSS S. F. I O2 FURNISH AND INSTALL 2" SERVICE LINE PER 2017 IDAHO STATE PLUMBING CODE AND V C� 00 I I I CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. LENGTH PER PLAN. SEE DETAIL � I L OF "PVC 2.61% FFE. 2575.33 0 @ 1 5 ON SHEET C6.00. C) M/ I 3 PROPOSED DOMESTIC WATER ENTRY LOCATION. STUB AND CAB WITHIN 5' OF `- , a Ly Z 3 W RIM:2573.39 O PROPOSED BUILDING FOOTPRINT. SEE PLUMBING PLANS FOR CONTINUATION. _ � I I INV:2570.21 I IL — — — I ® FURNISH AND INSTALL 6" C900 PRIVATE FIRE WATER LINE LINE PER 2017 IDAHO STATE Q O INV:2570.21 9 9 1 5 LF OF 4"PVC @ 2.61% I I PLUMBING CODE AND CITY OF MERIDIAN STANDARDS AND SPECIFICATIONS. LENGTH N 7 LF OF 4"PVC @ 2.61% 1 N I PER PLAN. j < \SS 1 55 LF OF 2"PVC 2 4 O 9 INV:2571.03 < O5 FURNISH AND INSTALL 45° BEND WITH THRUST BLOCK PER ISPWC SD-403.SEE DETAILINA Q Q 1 I 6 ON SHEET C6.00. O Q I INV:2572.04 9 SS SS 1 9 LF OF 4"PVC @ 2.61 01 © PROPOSED FIRE LINE ENTRY LOCATION. STUB AND CAB WITHIN 5 OF PROPOSED SS W •rj INV:2570.81 I � BUILDING FOOTPRINT. SEE PLUMBING PLANS FOR CONTINUATION. � U 1 ILLI S I W 1 S (n 10 INV:2570.81 I 0O7 FURNISH AND INSTALL REMOTE FIRE DEPARTMENT CONNECTION WITH THREAD-ON z EXTERNAL STORZ ADAPTER WITH BLIND CAP. THRUSTBLOCKING PER DETAIL 6 ON �\ 8 I 52 LF OF 6"C900 4 5 21 LF OF 4"PVC 2.00% 1 SHEET C6.02. a � INV:2572.33 9 1 7 LF OF 4"PVC @ 2.00% 1 @ I FURNISH AND INSTALL 8" JURISDICTIONAL GATE AND 8" X 6" REDUCER PER CITY OF O 1 7 LF OF 4"PVC @ 2.00% 7 I I MERIDIAN STANDARDS AND SPECIFICATIONS. SS SS SS Z U) V I $ 1 14 LF OF 4"PVC @ 2.00% — I I C ' r Y N RIM:2574.79 ` Ilia I 2 34LFOF2"PVC 6 INV:2571.56 DRY UTILITY NOTES ui 1 30 LF OF 4"PVC @ 44.80% \\ / 23 1 !!CAUTION!! UTILITY CROSSING. VERIFY INVERTS PRIOR TO CONSTRUCTION. ENV:2559.61 I 32 LF OF 6"C900 4 � \ � I O - -I— - - - - — 3- - - I 25 LF OF 4"PVC @ 2.00% 1 \ \ 00 I 5 I i O2 PROPOSED ALIGNMENT OF POWER. SEE MEP PLANS FOR INFORMATION. COORDINATE N I RIM:2572.62 3 WITH POWER COMPANY ON INSTALLATION. INV:2569.44 N i I I O3 PROPOSED GAS SERVICE ENTRY LOCATION. STUB AND CAP WITHIN 5' OF PROPOSED BUILDING FOOTPRINT. SEE MEP PLANS FOR CONTINUATION. ® PROPOSED ALIGNMENT OF GAS SERVICE. COORDINATE WITH INTERMOUNTAIN GAS PREPARED FOR: 2 23 LF OF 2"PVC I I ON INSTALLATION. . AHLQUIST DO PROPOSED TRANSFORMER LOCATION. CONNECT TO EXISTING ELECTRIC SERVICE 23 LF OF 6"C900 4 I LINE PROVIDE BY IDAHO POWER. SEE MEP PLANS FOR INFORMATION. 1 144 S SllverStone Way © PROPOSED POWER SERVICE CONNECTION LOCATION. SEE MEP PLANS FOR Ste #500 Meridian, ID 83642 CONTINUATION. 200 5 7 I I O7 PROPOSED TELECOM/CATV ENTRY LOCATION. SEE MEP PLANS FOR INFORMATION. BRAD SMITH 2 55 LF OF 2"PVC y I I ® CONNECT TO EXISTING GAS LINE. CONTRACTOR TO COORDINATE WITH DEVELOPER. ° I COORDINATE WITH INTERMOUNTAIN GAS. (208) 841-9449 PROPOSED TELECOM/CATV ALIGNMENT. SEE MEP PLANS FOR INFORMATION. REVISIONS No. Description Date 2 1 ADDENDUM 1 04/29/2026 ) LEGEND 1100 c900 4 3 6 �� I � II 1 TV 3 PROPERTY LINE O 2 LF OF 2"PVC 2 7 37 LF OF 6"C900 4 3 4 ILF OF 6"C900 I W 4 3 LF OF 6"C900 I EXISTING WATER LINE V) I y I 5 �\ 58 LF OF 2"PVC 2 GAS GA 1 I W PROPOSED DOMESTIC WATER SERVICE LINE c� ~ I S S EXISTING SANITARY SEWER LINE N�\ gg 11 LF OF 2"PVC 2 rJ SS SS PROPOSED SANITARY SEWER LINE c3 23 LF OF 6"C900 4 `� / W �� v�r W � 4 1��F 6"C�0 - GAS GAS GAS — EXISTING GAS LINE W M W 5 5 4 13 LF OF6"900 cn I 4 59 LF OF 6 C900 4 60 LF OF 6 C900 I I GAS GAS GAS PROPOSED GAS LINE (/7 I E EXISTING POWER LINE I E PROPOSED POWER LINE 3 — ° COM EXISTING TELECOM LINE Project No.: 193217010 ' F CQM PROPOSED TELECOM LINE Drawn By: PJS PI PI—Pi— EXISTING PRESSURE IRRIGATION LINE Reviewed By: BMD V I Date: 2026-04-29 I I I NORTH GRAPHIC SCALE IN FEET 0 5 10 20 Cn roo I I � I I I I Uj co UTILITY PLAN CD U C5000 0 0 T