Loading...
HomeMy WebLinkAboutBlueberry Hills - Fire Exhibit Blueberry Hills Subdivision A parcel of land lying in the SE 1/4 of the NE 1/4 of Section 34, Township 4 North, , Range 1 West, Boise Meridian, City of Meridian, Ada County, Idaho Parcel Number SO434142125 Partners 4315 N Ten Mile Road, Meridian, ID 83646 2815 E 3300 S, Salt Lake City, UT 84109 I (801) 305-4670 wvvw.edmpartners.com I SCALE: 1" = 60' _ O •I ® _ �' 0 30 60 120 180 DEVELOPER: 70.00 0 4 I I DMH 3 I 8 a I I I I I ,,-'-RIM:EX. 255 2557.55' � ALL-WEATHER GRAVEL Rl BLOCK 6 FIRE TURNAROUND. 1 8 �' h TO BE RELEASED UPON I aZ � �a I 11 ROAD EXTENSION J I I I I I I I I ET� GE —o \ \ O L4 - - � v I I 3 I I BLOCK II I� = = —� DEVELOPMENT 4 T w o I I I / I� BLOCK 5 20.00'TEMPORARY FIRE I I I L — — —I — W I EX. SSMH ACCESS EASEMENT,TO _ W BE RELEASED UPON I RIM:2556.98' 2 I 2 I W BELLTOWER DR.i I 27"PVC (N):2544.30' EXTENSION OF 5 I 3 I I I I I / III 30"PVC(S):2543.7T NOTES. \� SWEET MELODY LANE / 24"PVC (E):2544.54' —I 20.00' ]111PHASE 2 I \� _ — _ I I _ _ — 1. This drawing is considered preliminary unless ALL-WEATHER zokol 6 PROPOSED HYDRA' I affixed with a municipal approval or ,GRAVEL FIRE POSED HYDRANT �O L — — J accompanied by a separate approval document. TURNAROUND _� L PROPOSED HYDRANT 3 I I PRO— _ I K 2 I I 2. All sanitary sewer improvements shall conform J c o 0 7 __ Rz °°. r C�I I I with the standards and specifications of the 21 City of Meridian. W LL \ _ 20.00'TEMPORARY1 R� 3. All culinary water improvements shall conform ACCESS EASEMENT, TO I I N I I with the standards and specifications of the BE RELEASED UPON I I I II I II III II 3 City of Meridia n.ROAEXTENSIONo shall conform wit h the standards and/ 4. All improvements in the public right o f way F (00, - specifications of the Ada County Highway — i> District (ACHD) and the Idaho Standards ForBLOCK 4 11 L BLOCK 3 2 Public Works Construction-ACHD Supplement 4 3 � I LU 5 4 I 3 2 9 7 6 5 I (ISPWC ACHD). 5. All private improvements shall conform to Idaho } + 3 ; I I� Standards For Public Works Construction 1 I I I o �a .I I `" I (ISPWC) standards and specifications. I II I II I 6. Contractor to field locate and verify the LU I I I I horizontal and vertical location of all utilities ` Rzs.00 I 11 prior to beginning work. ■ N ■ vC I I G I I UQ I I p7 N I I I N I I � N PRELIMINARY ENGINEERING NOTES ENGINEERING NARRATIVE: 1. DOMESTIC WATER SERVICE WILL BE PROVIDED BY CITY OF MERIDIAN. 8" WATER MAINS WILL BE INSTALLED THROUGHOUT THE The project is primarily located in the White Drain Sewer Trunkshed. SUBDIVISION CONNECTING TO THE EXISTING 8"WATER MAIN ON N. ADKINS AVE. 2. SANITARY SEWER SERVICE WILL BE PROVIDED BY THE CITY OF MERIDIAN. THE PROPERTY WILL BE SERVED BY AN EXTENSION TO THE Lots 8 Et 9, Block 3; Lots 2-5, Block 4; Lots 2-3, Block 5; and Lots 1, 2, 5, Et 6, Block 6 are located in the North Black Cat EXISTING 8" SEWER TRUNK ON N. ADKINS AVE. Sewer Trunkshed. There are no viable connections for this project in the Black Cat Sewer Trunkshed. Therefore, this 3. WATER AND SEWER LINE SIZES AND LOCATIONS ARE PRELIMINARY AND WILL BE REFINED DURING FINAL DESIGN. preliminary plat is requesting that the named lots be allowed to drain to the White Drain Sewer Trunkshed. 4. ALL DOMESTIC WATER MAINS AND SANITARY SEWER WILL BE INSTALLED IN ACCORDANCE WITH THE IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY AND CITY OF MERIDIAN REQUIREMENTS. To accomplish this, the gravity sewer main must be extended to the last buildable lot. This will require importing fill and 5. ALL STREETS NOT LOCATED WITHIN A COMMON LOT SHALL BE DEDICATED TO ACHD. filling to a maximum of approximately 4.25-ft above existing grade in the proposed Right-of-Way. In an effort to minimize 6. STORM DRAINAGE SHALL BE COLLECTED AND ROUTED TO STORM RETENTION FACILITIES THAT MEET ACHD'S AND THE CITY OF MERIDIAN'S required fill and elevation change, buildable Lots 3-5, Block 4 and Lots 5 Et 6, Block 6 will slope away from the back of REQUIREMENTS. THE STORM RETENTION FACILITY TYPES, SIZES, AND LOCATIONS WILL BE DETERMINED DURING FINAL DESIGN. sidewalk. This results in a house that is located below the road grade and sewer main. 7. GRAVITY IRRIGATION WATER HAS BEEN PROVIDED BY SETTLERS IRRIGATION DISTRICT (SID) IN COMPLIANCE WITH IDAHO ADMINISTRATIVE PROCEDURES ACT (IDAPA) SECTION 31-3805. SECONDARY IRRIGATION WATER SOURCE SHALL BE PROVIDED, AS REQUIRED, IN In order to transfer sewage from the named individual lots, each home will be required to utilize a private sewer ejector ACCORDANCE WITH CITY OF MERIDIAN SPECIFICATIONS. pump. The private sewer ejector pump and pressure service will entirely be the responsibility of the homeowner. This 8. CONSTRUCTION OF THE FOLLOWING IMPROVEMENTS WILL BE IN COMPLIANCE WITH THE STANDARD MERIDIAN CONSTRUCTION NOTES: pump will lift the sewage from the home to gravity sewer service that is terminated at the Right-of-Way line. Please see WATER, DRAINAGE, SEWER, AND PRESSURE IRRIGATION. the detail on this sheet. This will apply only to Lots 3-5, Block 4 and Lots 5 Et 6, Block 6. 9. CITY OF MERIDIAN SANITARY SEWER AND WATER EASEMENT LOCATIONS TO BE DETERMINED DURING FINAL DESIGN. 10. PUBLIC UTILITIES LOCATED WITHIN THE SITE SHALL BE HOUSED IN A PUBLIC UTILITY EASEMENT. In the event that the City determines not to grant the Out-of-Shed request, the lots named above will be restricted to 11. REFER TO PP-3 FOR STREET SECTIONS. non-buildable status, by final plat, until public sewer is made available via adjacent development. 12. GRADING AND EARTHWORK IS NOT INCLUDED OR SHOWN ON THESE PLANS. 13. ALL LOT LINES COMMON TO THE PUBLIC RIGHTS-OF-WAY CONTAIN A 10.00-FT WIDE EASEMENT FOR PUBLIC UTILITIES, CITY OF MERIDIAN STREET LIGHTS, HOMEOWNER'S ASSOCIATION IRRIGATION AND LOT DRAINAGE 14. UNLESS OTHERWISE DIMENSIONED, ALL LOT LINES COMMON TO THE SUBDIVISION BOUNDARY AND ALL REAR LOT LINES CONTAIN A 10.00-FT WIDE EASEMENT FOR PUBLIC UTILITIES, HOMEOWNER'S ASSOCIATION PRESSURIZED IRRIGATION AND LOT DRAINAGE. c� 3 c, v U U w � Blueberry Hills W o o Subdivision Fire Access Plan g 47.00' r. PROJECT: PROJECT# w DRAWN BY: CLS 16.50' 16.50' REVIEWED BY: ERB /r— 5.00' 2.00' 0 No.2.00' 5.00' 2.00% 2.00% —� IONS No. DATE REMARKS 5 CONCRETE SIDEWALK PER ACHD SUPPLEMENTAL 3" ROLLED CURB PER STANDARD DRAWING SD-709 DATE: Q ACHD SUPPLEMENTAL February 3, 2026 STANDARD DRAWING SD-702 SHEET NUMBER: Q TYPICAL ROAD SECTION w A