Loading...
HomeMy WebLinkAboutConceptual Site and Utility Plan SITE ANALYSIS PARKING TABLE 1. LOT SIZE: 12.83 AC E. PINE RD. �y 2. BUILDING SIZE: 94,437 S.F. TOTAL BUILDING AREA 92,836 S.F. No 3. SETBACKS: REFER TO ARCHITECTURAL - o PLANS FOR EACH BUILDING. REQUIRED PARKING 186 SPACES 1.00/500 S.F. -- - Ln T - C 4. EASEMENTS AS SHOWN ON PLAN. I �' 0 M 5. PARKING ANALYSIS PER PARKING TABLE CUSTOMER PARKING 208 SPACES ON THIS SHEET. ACCESSIBLE PARKING 11 SPACE - _ - - ► -j • TOTAL PARKING 219 SPACES 2.32/1,000 S.F. ■A c -= SITE O Z 3 7tr g� W LOCATION >_ ca EXISTING 12" WATER DEMOLISH EXISTING PEDESTRIAN RAMPS DEMOLISH EXISTING PEDESTRIAN RAMPS MAIN TYP AND PORTION OF SIDEWALK FOR (TYP) AND PORTION OF SIDEWALK FOR INSTALLATION OF PROPOSED DRIVEWAY M INSTALLATION OF PROPOSED DRIVEWAY =�- ` j O 3 ' M M CONNECT 6" FIRE HYDRANT LINE L.L.I __u TO EXISTING 12" WATER MAIN + W M - �q M nn PLACE CASING ON WATER MAIN AT PROPOSED 24" GRAVITY IRRIGATION x 0 _ E. FRANKLIN RD. LINE AND IRRIGATION BOXES TYP ; F ' &� 1'~ GRAVITY IRRIGATION CROSSING (TYP) N. LOCUST GROVE ROAD (TYP)EXISTING PROPERTY PROPOSED 24" LINE (TYP) EXISTING CONCRETE 3 EXISTING 12" WATER VICINITY MAP GRAVITY IRRIGATION CONNECT TO EXISTING EXISTING CONCRETE SIDEWALK TO REMAIN MAIN (TYP) LINE AND IRRIGATION _ 10" WATER MAIN STUB SIDEWALK TO REMAIN NOT TO SCALE BOXES (TYP) O 0 _ p 0 c� 0 - �- i cNn GI GI GI GI GI GI GI GI CI GI GI GI GI GI �— - CONNECT TO EXISTING RELOCATE EXISTING o '1 8" WATER MAIN STUB v IRRIGATION BOX 4W W 00 W 0 w SEEOPAOSED GE BED 0LFF--]] f EXISTING CONCRETE G N 0 0 J INSTALL 6" FIRE SERVICE SIDEWALK TO REMAIN 0 0 PROPOSED11 STUB TO THE BUILDING (TYP) o _ SEEPAGE BED O I I Q PROPOSED 8" PUBLIC 3 INSTALL 2" WATER METER O N cn WATER MAIN PROPOSED 8' PUBLIC I AND EXTEND 2 STUB TO EXISTING PROPERTY THE BUILDING (TYP) LINE (TYP) a Z (TYP) WATER MAIN (TYP) I II II L—i) L6_ti_'m III , INSTALL 6 SEWER STUB Z I _ PROPOSED 20PROPOSED = J WATER EASEMENT-4 I TO BUILDING (TYP) -SEEPAGE BED 0 c�J PROPOSED 20' (TYP) WATER EASEMENT 3 Z Q (TYP) CONNECT TO EXISTING I CV ® ® ® mmummrq� Ll8" WATER MAIN STUB Q LL 'it go INSTALL 6" FIRE SERVICE I �� Q uj M INSTALL 2" WATER METER ® ® STUB TO THE BUILDING (TYP)— O \ O SE PAGE BED O O . Q W 00 AND EXTEND 2" STUB TO PROPOSED ® PR WA ERDMAINP(TYP) W U) THE BUILDING (TYP) SEEPAGE BED IN Z O cn PROPOSED FIRE HYDRANT (TYP) 0 W Q Q PROPOSED 20 / 0 INSTALL 6" SEWER STUBENT PROPOSED FIRE I I EXISTING SEWER_ WATER EASE(TYP) / / 0 Z o MAIN TO REMAIN / W Q TO BUILDING (TYP) HYDRANT (TYP) I I v > �' cn `-�i / 0 N cn i / ss / C� L - - -w w w w w w w w w w w w w w w w w w w s� / I 18+28 18+00 17+00 16+00 15+00 14+00 S� SSA SS SS SS b SS SS A SS SS 4 �� O O O. PROPOSED 8" PUBLIC OOOOOOOOOOOOOOOOOOOOOOo 3 EXISTING 1 N = c� I E LG�� WATER MAIN TYP SEWER MAIN E cn J PROPOSED SEWER PROPOSED 8" PUBLIC c/)� MANHOLE (TYP) PROPOSED TRASH 7EXISTING PROPERTY SEWER MAIN (TYP) PROPOSED TRASH PROPOSED / �1 ESN CD ENCLOSURE (TYP) F, LINE (TYP) ENCLOSURE (TYP) SEEPAGE BED PROPOSED � �5 / PROPOSED PROPERTY PROPOSED 30 SEWER INSTALL 2 WATER METERS INFILTRATION BASIN / LINE (TYP) I 3: AND WATER EASEMENT AND EXTEND 2" STUBS TO (TYP) THE BUILDINGS (TYP) 3 NOTE: SEE SHEET C2.0 FOR � / 'cD PROPOSED 20' PEDESTRIAN EASEMENT PROPOSED 8" PUBLIC I �`� / PROPOSED 20'EASEMENT AND EXISTING 20 SEWER EASEMENT PUBLIC SEWER MAIN PROFILE WATER MAIN (TYP) / / ER(TYP) _ 00 LEGEND 3 cn o 0 _ _ _ / EXISTING PROPERTY LINE ARCHITECT EXISTING 18" / ° CD EXISTING WATER LINE W W ANTHONY SWANSON / / / SEWER MAIN / A EXISTING SEWER LINE — SS SS HILLSIDE ARCHITECTURE, PLLC / / / / 0 EXISTING GRAVITY IRRIGATION LINE GI GI 345 W BOBWHITE CT., STE 120 REMOVE EXISTING BOISE, ID 83706 cn SEWER MAIN / / / PROPOSED PROPERTY LINE - - 208-890-4837 � PROPOSED FIRE / / / / PROPOSED SEWER LINE —SS SS / PROPOSED WATER LINE W w CIVIL ENGINEER: HYDRANT (TYP) PROPOSED GRAVITY IRRIGATION LINE GI GI MICHAEL NASLAND, PE PROPOSED EASEMENT — — — — NASLAND ENGINEERING I cn 1109 W MAIN STREET, STE 660 3 Cut) / v o BOISE, ID 83702 PROPOSED 30' SEWER o „ PROPOSED SEEPAGE BED 208 593 4676 AND WATER EASEMENT + INSTALL 6 SEWER STUB TO BUILDING (TYP) (TYP) / / p W / / S / NE JOB #: 325-097.1 PROPOSED INFILTRATION BASIN r / DATE: 04/21/2026 � / DRAWN BY: AW J / / F' PROPOSED 20' PEDESTRIAN EASEMENT � CHECKED BY: MN AND EXISTING 20' SEWER EASEMENT 10 GI PROPOSED SAND AND GREASE TRAP CONNECT PROPOSED 8" SEWER / / MAIN TO EXISTING 8" SEWER J' / / // PROPOSED 8" PUBLIC STUB AND INSTALL MANHOLE / / �// �,`' --WATER MAIN (TYP) CD PROPOSED WATER METER © PROPOSED � � / // � � �� INFILTRATION BASIN / c�S PROPOSED FIRE HYDRANT oo PROPOSED SEWER MANHOLE CONCEPTUAL Ss EXISTING MAIN / SITE & UTILITY SOURCE OF IRRIGATION SS S / SEWER / PLAN PRIMARY SOURCE OF IRRIGATION: SURFACE WATER EP rn / 40 0 40 80 120 160 RIGHT WITH NAMPA AND MERIDIAN IRRIGATION DISTRICT. F,Q / �� EXISTING PROPERTY LINE (TYP) BACKUP SOURCE OF IRRIGATION: CITY OF MERIDIAN SCALE 1" = 40' POTABLE WATER SYSTEM. c� ■ PROPOSED PROPERTY � 0 LINE (TYP) I 3 0