Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
C-2 - NOTE SHEET
This Document, and the Concepts, Ideas and Design Incorporated herein are an instrument of professional services and are the Property of Mason and Associates, Inc., therefore they are not to be used in whole or part for any other project without the express Written Authorization of Mason and Associates, Inc.© All construction shall conform to the 2020 edition of the Idaho a Standards for Public Works Construction, most current edition of P- City of Meridian Supplemental Specifications, and the Applicable a Irrigation District Standards. U w 0 0 m GENERAL CONSTRUCTION SEWER DRAINAGE o z 1. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT VERSION OF THE IDAHO 1. CONSTRUCTION OF THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE WASTEWATER RULES FOR COMMERCIAL SUBDIVISIONS OR COMMERCIAL PROJECTS K17H PUBLIC MAINS THAT HAVE ON-SITE DRAINAGE. SNOISIA38 STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), THE CITY OF MERIDIAN SUPPLEMENTAL (IDAPA 58.01.16) AS WELL AS THE STANDARDS AND SPECIFICATIONS REFERRED TO IN GENERAL LO SPECIFICATIONS TO THE ISPWC (AND ANY ADDENDUMS), MERIDIAN DESIGN STANDARDS, THE CONSTRUCTION NOTE NO. 1. 1. FOR ANY DRAINAGE FACILITIES WITHIN A PUBLIC RIGHT OF WAY, ACHD OR ITD SHALL BE RESPONSIBLE FOR N N N REQUIREMENTS OF THE ADA COUNTY HIGHWAY DISTRICT (ACHD), AND/OR THE REQUIREMENTS OF THE INSPECTION. FOR ANY PRIVATE DRAINAGE FACILITIES THE PROJECT ENGINEER OR ARCHITECT SHALL BE co cfl IDAHO TRANSPORTATION DEPARTMENT (ITD). THE MORE STRINGENT OF ANY OF THESE STANDARDS SHALL 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS (SANITARY RESPONSIBLE FOR INSPECTION AND CERTIFICATION OF DRAINAGE FACILITIES, HOWEVER ANY ROOF DRAINAGE BE THE CONTROLLING STANDARDS OR SPECIFICATIONS. SEWER, STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET WHERE IT IS AND PIPING TO THE DRAINAGE FACILITIES WILL BE INSPECTED BY THE MERIDIAN PLUMBING OFFICIAL UNDER C- CL NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN THE APPROPRIATE PERMIT. 2. THE CONTRACTOR SHALL HAVE A COPY OF THE LATEST CITY OF MERIDIAN STANDARD SPECIFICATIONS EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN AND DRAWINGS ON SITE OR READILY ACCESSIBLE AT ALL TIMES DURING CONSTRUCTION (AVAILABLE ON ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA o m THE CITY WEBSITE). FAILURE TO HAVE ACCESS TO A CURRENT COPY OF THE STANDARD SPECIFICATIONS 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). Z z W m ON SITE COULD BE GROUNDS FOR A STOP WORK ORDER UNTIL THE SITUATION IS RESOLVED. ROADWAY c� Y 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE W T Q 3. THE CONTRACTOR SHALL HAVE PLANS STAMPED `APPROVED FOR CONSTRUCTION" BY CITY OF MERIDIAN WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A POTABLE WATER o U Q ON SITE AT ALL TIMES. MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL 1. ALL CONTRACTORS WORKING WITHIN THE PUBLIC ROAD RIGHT-OF-WAY ARE REQUIRED TO SECURE A SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE RIGHT-OF-WAY CONSTRUCTION PERMIT FROM ACHD OR ITD AT LEAST TWENTY-FOUR (24) HOURS PRIOR W N h 4. ALL CONTRACTORS, SUBCONTRACTORS, AND UTILITY CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION TO CONSTRUCTION. o IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE CONFERENCE PRIOR TO START OF WORK. m m c p WASTEWATER RULES (IDAPA 58.01.16). 2. ACHD OR ITD WILL INSPECT ALL WORK WITHIN THE PUBLIC RIGHTS-OF-WAY TO INCLUDE UTILITY a @ A 5. CONTRACTORS SHALL NOTIFY THE APPROPRIATE AGENCY WHEN MATERIALS ARE ON SITE OR INSPECTION TRENCHES ABOVE THE PIPE ZONE. «� z 4. PLACE SEWER SERVICE LINES IN A SIX (6) INCH DIAMETER WATER CLASS PIPE SLEEVE WHEREVER THE w a °� OF THE WORK IS REQUIRED. NO WORK MAY BEGIN ON ANY PROJECT WITHOUT TWENTY FOUR (24) HOUR SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY I.E., SEEPAGE BEDS, DRAINAGE SWALES . 3. THE ENGINEER OF RECORD CERTIFIES THAT THE PLANS ARE PREPARED IN SUBSTANTIAL CONFORMANCE o J a PRIOR NOTICE. ( ) WITH THE ACHD POLICY AND STANDARDS IN EFFECT AT THE TIME OF PREPARATION. THE ENGINEER N N 6. CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS PRIOR TO THE REQUIRED TESTING. ACKNOWLEDGES THAT ACHD ASSUMES NO LIABILITY FOR ERRORS OF DEFICIENCIES IN THE DESIGN. ALL m THE CONTRACTOR MAY NOT OPEN OR CLOSE WATER VALVES. VARIANCES FROM ACHD POLICY SHALL BE APPROVED IN WRITING. THE FOLLOWING VARIANCES LISTED BY a CLASS "A" MUNICIPAL WASTEWATER RECLAMATION AND REUSE DATE AND SHORT DESCRIPTION, WERE APPROVED FOR THE PROJECT. 7. ALL MATERIAL FURNISHED ON, OR FOR THE PROJECT MUST MEET THE MINIMUM REQUIREMENTS OF THE APPROVING AGENCIES. AT THE REQUEST OF THE APPROVING AGENCY OR THE DESIGN ENGINEER, FOR COMMERCIAL SUBDIVISIONS OR COMMERCIAL PROJECTS THAT HAVE PUBLIC REUSE MAIN OR SERVICES lu CONTRACTORS SHALL FURNISH PROOF THAT ALL MATERIALS INSTALLED ON THIS PROJECT MEET THE SPECIFICATION REQUIREMENTS SET FORTH IN GENERAL CONSTRUCTION NOTE NO. 1. 1. CONSTRUCTION OF THE CLASS A EFFLUENT DISTRIBUTION SYSTEM SHALL CONFORM TO THE STANDARDS IN THE SUPPLEMENTARY NOTES , M IDAHO RECYCLED WATER RULES (IDAPA 58.01.17), WASTEWATER RULES (IDAPA 58.01.16), RECOMMENDED 8. WORK SUBJECT TO APPROVAL BY ANY GOVERNMENTAL AGENCY MUST BE APPROVED PRIOR TO (A) STANDARDS FOR WASTEWATER FACILITIES GREAT LAKES - UPPER MISSISSIPPI RIVER BOARD OF SANITARY BACKFILLING TRENCHES FOR PIPE, (B) PLACING OF. AGGREGATE BASE, (C) PLACING OF CONCRETE, (D) ENGINEERS (10 STATES STANDARDS), AWWA MANUAL M24 - CHAPTER 24 AS WELL AS THE STANDARDS AND 1. CONTRACTOR(S) SHALL RETAIN AND PROTECT ALL EXISTING FEATURES BOTH ABOVE AND BELOW GROUND, PLACING OF ASPHALT PAVING. SPECIFICATIONS REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1. UNLESS OTHERWISE NOTED ON THE PLANS OR AS DIRECTED BY THE ENGINEER. 9. INSPECTION, APPROVAL AND FINAL ACCEPTANCE OF ALL WATER AND SEWER CONSTRUCTION SHALL BE 2. THE HORIZONTAL SEPARATION OF CLASS A EFFLUENT DISTRIBUTION MAINS AND POTABLE WATER MAINS SHALL 2. MASON & ASSOCIATES, INC. WILL PROVIDE CONSTRUCTION STAKES AS REQUESTED BY OWNER. BY THE PUBLIC WORKS DEPARTMENT, AND THEIR DECISION SHALL BE FINAL: SUCH INSPECTIONS SHALL BE A MINIMUM OF TEN (10) FEET IN ACCORDANCE WITH IDAPA 58.01.08, "IDAHO RULES FOR PUBLIC DRINKING NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PERFORMING ?,THE WORK IN AN WATER SYSTEMS," SUBSECTION 542.07. WHERE IT IS NECESSARY FOR A CLASS A EFFLUENT DISTRIBUTION MAIN 3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ANY NECESSARY NPDES PERMITS, FILING ACCEPTABLE MANNER IN ACCORDANCE WITH THE DEQ/QLPE APPROVED CONSTRUCTION PLANS. AND POTABLE WATER MAIN TO CROSS, A MINIMUM OF EIGHTEEN (18) INCHES OF VERTICAL SEPARATION SHALL ANY NOI'S, AND PREPARING A POLLUTION PREVENTION PLAN (PPP) IN ACCORDANCE WITH THE BE MAINTAINED AND THE CLASS A EFFLUENT DISTRIBUTION MAIN SHALL BE ENCASED IN A CONTINUOUS PIPE ENVIRONMENTAL PROTECTION AGENCY. CONTACT THE EPA AT (208) 334-9489 FOR THE REQUIRED 10. ANY DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS MUST HAVE THE APPLICABLE AGENCY SLEEVE TO A DISTANCE ON EACH SIDE OF THE CROSSING EQUAL TO TEN (10) FEET. CLASS A EFFLUENT INFORMATION. SAID PERMIT SHALL BE PRESENTED TO THE OWNER/DEVELOPER AT LEAST 48 HOURS LAJ APPROVAL IN WRITING PRIOR TO CONSTRUCTION. DISTRIBUTION MAINS INSTALLED PARALLEL TO NON-POTABLE WATER MAINS (SANITARY SEWER, STORM DRAIN PRIOR TO THE BEGINNING OF THE CONSTRUCTION. >_ 11. PRIOR TO BEGINNING INSTALLATION OF STREET LIGHTS THE ELECTRICAL CONTRACTOR SHALL OBTAIN AN AND IRRIGATION) SHALL BE INSTALLED AT LEAST FIVE (5) FEET HORIZONTALLY FROM THE NON-POTABLE MAIN ANY IF THE NON-POTABLE MAIN IF THE NON-POTABLE MAIN IS LOCATED ABOVE THE CLASS A EFFLUENT MAIN AND 4. CERTAIN CONTROL POINTS WILL BE SET BY THE ENGINEER, OR ITS REPRESENTATIVE, WHICH ARE ELECTRICAL PERMIT FROM THE BUILDING DIVISION OF THE MERIDIAN PUBLIC WORKS DEPARTMENT. DEVIATION IN STREET LIGHT LOCATIONS FROM THE APPROVED PLANS MUST BE APPROVED WRITING THREE (3) FEET HORIZONTALLY FROM THE NON-POTABLE MAIN IF THE NON-POTABLE MAIN 1S LOCATED BELOW CRITICAL TO THE CONSTRUCTION STAKING OF THE PROJECT. THESE POINTS WILL BE DESIGNATED AT THE cc THE CLASS A EFFLUENT MAIN. TIME THEY ARE SET AND THE CONTRACTOR SO NOTIFIED. DESTRUCTION OF THESE POINTS BY THE FROM THE CITY ENGINEER. CONTRACTOR OR HIS SUBCONTRACTORS SHALL BE GROUNDS FOR CHARGING THE CONTRACTOR FOR THE 3. THE HORIZONTAL SEPARATION OF CLASS A EFFLUENT DISTRIBUTION SERVICES AND POTABLE WATER SERVICES COST OF RE-ESTABLISHING SAID POINTS. Z0 OR POTABLE WATER MAINS SHALL BE MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A CLASS A WATER EFFLUENT DISTRIBUTION SERVICE AND A POTABLE WATER MAIN TO CROSS A MINIMUM OF EIGHTEEN (18) 5. ALL CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE FOR COMPLIANCE WITH INCHES OF VERTICAL SEPARATION SHALL BE MAINTAINED, AND THE CROSSING SHALL BE CONSTRUCTED IN ALL APPLICABLE SAFETY LAWS OF ANY JURISDICTIONAL BODY. THE CONTRACTOR SHALL BE RESPONSIBLE 00 ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA FOR ALL BARRICADES, SAFETY DEVICES AND CONTROL OF TRAFFIC WITHIN AND AROUND THE 00 1. CONSTRUCTION OF THE WATER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE "IDAHO RULES FOR CONSTRUCTION AREA. ,� PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)" AS WELL AS THE STANDARDS AND SPECIFICATIONS 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.016). w REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1. 6. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE v 4. LABEL ALL IRRIGATION RISERS AND FAUCETS WITH DURABLE TAGS CARRYING THE WARNING CAUTION.RECYCLED CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WATER-DO NOT DRINK, BOTH IN ENGLISH AND SPANISH. WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH OCCUR LO N 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS (SANITARY N o SEWER; STORM DRAIN, AND IRRIGATION SHALL BE A MINIMUM OF TEN 10 FEET WHERE IT IS BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. CONTACT N Z Z ( ) 5. AN APPROVED BACKFLOW PREVENTER IS REQUIRED IF RECYCLED WATER SYSTEM (S CONNECTED TO THE DIG-LINE AT 1-800-342-1585. o N NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN POTABLE WATER SYSTEM. THE DEVICE MUST BE APPROVED BY THE IDAHO DEPARTMENT OF ENVIRONMENTAL N EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN QUALITY (DEQ), THE CITY OF MERIDIAN WATER DEPARTMENT, AND LISTED IN THE MOST CURRENT VERSION OF O Z ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA THE LIST OF APPROVED BACKFLOW PREVENTION ASSEMBLIES PUBLISHED BY THE FOUNDATION FOR 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH, UNIVERSITY OF SOUTHERN CALIFORNIA (USC). p O O W m 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE 6. THE PUBLIC WORKS DEPARTMENT SHALL INSPECT ALL RECYCLED WATER DISTRIBUTION MAINS AND/OR SERVICES. LU o U Q WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A POTABLE WATER FORTY-EIGHT (48) HOURS ADVANCE NOTICE IS REQUIRED. 0 60 > = U. MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). 4. PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE WHEREVER THE SERVICE LINE b CROSSES A STORM WATER TREATMENT FACILITY (LE., SEEPAGE BEDS, DRAINAGE SWALES). Y 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTINUOUS WATER SERVICE TO ALL EXISTINGUj WATER USERS AFFECTED BY CONSTRUCTION. IF WATER SERVICE MUST BE INTERRUPTED, THE CONTRACTOR '. SHALL COORDINATE WITH THE PUBLIC WORKS INSPECTOR. , or w J. ZPRESSURIZED I RRI GA TION 1q: W 145r N 0 1. THE PRESSURIZED IRRIGATION SYSTEM MUST BE BUILT TO THE STANDARDS OF THE IRRIGATION DISTRICT ,� O IN WHICH IT IS BEING CONSTRUCTED. L N 2. INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER IN ANY CONNECTION BETWEEN THE POTABLE E- WATER SYSTEM AND THE PRESSURE IRRIGATION SYSTEM. THE SYSTEM MUST BE APPROVED BY THE IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ) AND THE CITY OF MERIDIAN WATER DEPARTMENT. NOT APPROVED FOR CONSTRUCTIONLu 8 %lbT