Loading...
HomeMy WebLinkAboutConstruction Drawings_Part10 a o Q S\ONALLLJ F N �0��5��ENSFo _ > ¢ n c'yY1 16970 a 3-2-26 v O�,A��TF OF ENE M.GFZ U) u U 0 20 40 80 120 J J 'n u# Y SCALE: 1 = 40 � I I II JIII al Ala I I 11 1 I i O V) wl Iw I 1 1 I f v Ln Go > I I I I u_ m wl I Iw v i 1 1 (JulO I I I 1cpL 1 , oD �M zo I I I _ I 11 v 111 XO rn I I c wI Iw ° ° 1 1 3 m L �, � cn I I I 1 1 ` a - @J o II O ry LLJ aI I I W31.00 ATER E" MEN �i co fu wI Iw I IL - fu w I I �� g,�. 1 1 5 I �I ��, 1 � wI I Iw m i I o i t45LF 8" PVC 1 , N I oOc 12 Li I aI w Ala �� I t38LF 8" PVC I 12 ` %o, WI 0 Iw w I I Z �I 3 6 � 1 8 1 I I m > i \ \ 11 4t» 11 p wl I TiIw SE`NER/ _ - ___$--- s t24LF 8" PVC 2J _ II \ 41.00' �SEMENT ___- _1 t46LF 8" PVC f9LF 6" PVC_ _ M 7 me v a I I a \ - - - WATER 1 B.O. _ / t22LF 8" PVC � w1 I IIw \ 4.1PI 1 4 P► BLOCK 10 __ — I BLOCK 9 w ° L -------------------1 ` —4.:PI ,i• — 4,•PI - �� 13 \�� 8 `mc N zo I I 1 ` • 9 �� 6A t8LF 6" PVC 1 1 _ �t28LF 8 PVC g \ \ 7 VC s t43LF 8" PVC 11 \ U ��wl Iw - ------------------------- -- t1Q-7 _ RIVE \ \ \ z cn URN pR o o+;\ 8 \ g B I E o 1 T I � F OU IL t 175LF 12" PVC � - W'R wl IIw II - ___ Of O = I _ 1 3 — 1 1 t t55LF 12" PVC U ______-- ,- ;f25LF 8" PVC \ 12 t37LF 8" PVC \\ o a o _ _ _ _ _ 155LF 12" PVC _ r ___ I 10 \ 1 a • _—_— 4, \ 5 BLOCK 6 \ \�c a I alIa II g �-±112LF 12" PVC of 1- °____- ► - 'y,- t7LF 8" PVC j� U t20LF 12" PVC N `� w o wl I �w i i W. ROUTEBURN DRIVE LI) cn z aI �Ia .-------------------------- a —°— --�� N 4 12 \ 6 10 \ �� N I ,, °� a H t 14LF 6" PVC ` w wl IIw ________________ 1 � ' \ 12" CROSS (FLGxFLG) 7 \\ \ Q _ ---- Q I BLOCK 8 \\ s 0.0 / 12" GATE VALVE (S) a 12"x8" REDUCER (N+E) f4LF 8" PVC J' \ J O wI I jw W - - - - (2) 8" GATE VALVES (N+E) � 18 \ J 12 \�F O ER/ r cP S MENI ?i �,c` U wI la LL. / WATER 3A \ 9 cp; \ 9 0 / > R P�� \ALA / W O 0 / DESIGNED: C. GRAHAM � I / I v � wl IIw \ \ \ R � \ I \ / O O I \\ DRAWN: L. HAASE Ld I \ m wl �w W a I I \ 17 5 12 s e%g 12 CHECKED: C. GRAHAM Lij APPROVED: C. GRAHAM m I O \ O aQ aI Y o ~wiIw . I \ BLOCK 5 8 Q A`C a 2 I I I I a !T \ PREPARED FOR: O I I I W f22LF 6" PVC \ . ' F 1 1 1 LLC o m I w °� �I g \ 16 C. 0� 0 ' PO BOX 593 EAGLE, ID 83616 z KEYNOTES Q h lO CONNECT TO EXISTING 12" WATER MAIN BY CUTTING IN A 12"x12" TEE. INSTALL (3) 12" GATE \ I 0� J VALVES. MAKE COMPATIBLE CONNECTION TO EXISTING WATER MAIN. cn Y O REMOVE EXISTING 2 BLOW-OFF ASSEMBLY AND 8 GATE VALVE AND CONNECT TO EXISTING 8 WATER ` i Z O MAIN. MAKE COMPATIBLE CONNECTION TO EXISTING WATER MAIN. \ / O 3 / 0 Li O3 INSTALL 8" GATE VALVE AND 2" BLOW-OFF ASSEMBLY WITH CONCRETE COLLAR FOR FUTURE WATER 'g / WATER NOTES MAIN EXTENSION PER CITY OF MERIDIAN SD-W12. \ / , 1 IN > 3A INSTALL 12" GATE VALVE AND 2" BLOW-OFF ASSEMBLY WITH CONCRETE COLLAR FOR FUTURE WATER \ M d v 1. WATER CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE ISPWC MAIN EXTENSION PER CITY OF MERIDIAN SD-W12 / AND THE MERIDIAN SUPPLEMENTAL SPECIFICATION SECTION 400LL_ . \ / Z O 2. WATER SERVICES SHALL BE MARKED PER MERIDIAN STANDARD DRAWING SW3. O4 INSTALL SINGLE 1" WATER SERVICE LINE AND 3/4" METER SETTER PER CITY OF MERIDIAN SD-W1 AND () SD-W2. SET METER ELEVATIONS ACCORDING TO CITY OF MERIDIAN SD-W6. ,,. Z Z w 3. LOCATE WATER METERS PER MERIDIAN SD-W2. SET METER ELEVATIONS PER Z O Q o MERIDIAN SD-W6. O5 INSTALL DOUBLE 1" WATER SERVICE LINE AND 3/4" METER SETTER PER CITY OF MERIDIAN SD-W1 AND O 0 J z Q� SD-W3. SET METER ELEVATIONS ACCORDING TO CITY OF MERIDIAN SD-W6. N 4. SECTION LINE WATER MAINS SHALL HAVE 5 FEET OF COVER, IN ALL OTHER = AREAS COVER OVER WATER MAIN SHALL BE 4 FEET. O6 8x6 TEE (MJxFLG) % ce ? J 6" GATE VALVE (FLGxMJ) AA Z Ln 5. NO PERMANENT STRUCTURES SHALL BE LOCATED WITHIN AN EASEMENT OR 6" WATER MAIN (LENGTH PER PLAN) O O uj OVER A SEWER OR WATER MAIN. THIS INCLUDES BUILDING, CARPORTS, TRASH FIRE HYDRANT PER MERIDIAN SD-W8 AND SD-W9. U. m C W w ENCLOSURES, TREES, DEEP ROOTING BUSHES, ETC. = ui 6A 12x6 TEE (MJxFLG) 6. EXTEND WATER SERVICE PIGTAILS BEYOND PRESSURE IRRIGATION EASEMENT ON 6" GATE VALVE (FLGxMJ) W O Q z LOTS 9-12 BLOCK 6. 6" WATER MAIN (LENGTH PER PLAN) > Ln FIRE HYDRANT PER MERIDIAN SD-W8 AND SD-W9. O o OC O7 11.25' ELBOW (MJxMJ). SIZE TO MATCH MAINLINE. _ Q O$ 22.5' ELBOW (MJxMJ). SIZE TO MATCH MAINLINE. a Z J Y 045' ELBOW (MJxMJ). SIZE TO MATCH MAINLINE. 0 3 10 8"x8" TEE (FLGxFLG) Li (2x) 8" GATE VALVES (FLGxMJ) AS SHOWN 0 J 11 POTABLE/NON-POTABLE UTILITY MAIN CROSSING. SEE WATER NOTE #2 SHEET C0.1. U 12 POTABLE/NON-POTABLE SERVICE CROSSING. SEE WATER NOTE #3 SHEET C0.1. W 0 13 WATER MAIN/STORM DRAIN CROSSING. LOWER WATER MAIN IF REQUIRED TO ACHIEVE 18" VERTICAL V) N CSW PROJECT NO. 24005 CLEARANCE OR CONSTRUCT STORM DRAIN OF WATER CLASS PIPE AT CROSSING. SEE WATER NOTE #2 SHEET C0.1. 5� DRAWING DATE 03/02/2026 14 REMOVE EXISTING FIRE HYDRANT ASSEMBLY. CONNECT TO AND EXTEND EXISTING 6" WATER MAIN G 0 (LENGTH PER PLAN). RELOCATE FIRE HYDRANT ASSEMBLY AND INSTALL PER MERIDIAN SD-W8 AND U SD-W9. W o a C6mO