Loading...
HomeMy WebLinkAboutHCF Townhomes Landscape Plans z Lu . N M .•••�P�$OF IDq���• p� J 'J .•• S ••'SAY O ,��• LL1 Lu • wow W W .•v�S 'i* Z w Q NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF TREES PER CITY OF MERIDIAN UDC AND ARE NOT Q i w w I I OPEN SPACE CALCULATIONS. REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL QUALIFIED OPEN SPACE CALCULATIONS. Q I I DRIVE AISLE • ' L -165 7 - - - "� 193LF I COMMON LOT TREE CALCULATIONS (1 TREE/5000 SF) "��d�• .2!.:! .�••' 0•.•' < \ I ,���i9NDSCA •••••• E. WOODMURRA LN. (PRIVATE) \ BLOCK # LOT # (SF)LOT AREA QUALIFIED AREA (SF) QUALIFIED AREA (AC) REQ PRVD ��•� �•S- N � 8,750 8,750 0.20 2 3 T I 1 15 1,018 1,018 0.02 0 0 + t , 76 _ 84 1 27 845 845 0.02 0 0 s I I 1 28 952 952 0.02 0 0 , al + DRIVE AISLE BLOCK 1 Q O I °I 113LF 1 41 1,285 1,285 0.03 0 0 1 43 1,336 1,336 0.03 0 0 I 82 I I LuI z z w I p 1 56 819 819 0.02 0 0 0 Q�w w LuX) CI NowQw � w� I p 1 57 919 919 0.02 0 0 86 w w w 1 65 5,944 5,944 0.14 1 1 L V) DRIVE AISLE 5 l 72 ,I 1•l. — —356LF _ — — I �—� 1 76 965 965 0.02 0 0 l t 1 78 926 926 0.02 0 0 LLi . w $0 � > z 20' a 71 vi UTILITY — — I — — — 1 84 1,036 1,036 0.02 0 0 u 6 Is I O I I O 79 EASEMENT I ® \ J I I 1 86 27,816 27,816 0.64 6 6 Q 7 I 70 — _ . . C- �' ' TOTAL COMMON LOT TREES 9 10 0 78 °� ° I STREET TREE CALCULATIONS (1 TREE/35 LF) Lu N Lu Lu �— O l 69 t PUE — EASEMENT I s° I 'I I STREET NAME BUFFER WIDTH LF CALCULATION REQ PRVD/ EXST <+ I I E. KALINGA LN. (PRIVATE) i <l� — — E. HILL PARK ST. 10' 1,004 1,004 LF/35 29 30 32' O s 68 65 +. .!.. + +- +' + f. f` � �.` 11 +` } .+ .f• + -�' +` + y S. STOCKENHAM LN. (PRIVATE) 10' 249 N/A UTILITY I 0 7 EASEMENT I 'I III all s S.TAVISTOCK AVE. 10' 361 361 LF/35 10 9 10 67 BLOCK 1 I BLOCK ta( III I E. WOODMURRA LN. (PRIVATE) 10' 274 N/A 0 8 A 0 35 'PRIVATE LN E. KALINGA . ( ) 10 1,248 N SEWER AND WATER / 11 I i 66 64 63 62 61 60 59 58 57 �I 56 55 54 53 52 51 50 49 48 47 46 45 44 43 I EASEMENT S. BOSWELL LN. PRIVATE 10' 468 N A 0 15 0 I (PRIVATE) / w % �. . �. +. Q Q I I S. NEWBRIDGE LN. (PRIVATE) 10' 422 N/A 0 12 z -a _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ a li TOTAL STREET TREES 39 116 s a PATHWAY TREE CALCULATIONS (1 TREE/100 LF) I — — - - - - J - - - - - - — 1- — — - - - - — - - - - - — it °I a s Lu II BLOCK # LOT # LF CALCULATION REQ PRVD z N m w v I 1 65 192 192/100 2 2 1 86 137 137/100 1 1 20 21 22 23 24 25 26 27 I f 28 29 30 31 32 33 34 35 36 37 38 39 40 41 �; Il 1 1 2 1 106 106/100 z t 15 l I I O TOTAL PATHWAY TREES 3 3 ' }` •`'• . — DRIVE AISLE BUFFER TREE CALCULATIONS (1 TREE/35 LF) > t ® CALCULATION REQ PRVD/ EXST z X. 662/35 19 20 Q E. HILL PARK ST. � J + . FA EpP - o�o TOTAL DRIVE AISLE BUFFER TREES 19 20 a \ � S:. ` / �EP�EP-EP �p -EP-EP J J ww w TOTAL TREES REQUIRED/PROVIDED 71 151 Lu ��rEP EP W W � �w � �w 5 `� W W Q DQ Lu (n I(A w w *REQUIRED TREES RELOCATED DUE TO UTILITY AND EASEMENT CONFLICTS. O Q w LANDSCAPE COVER z z Lu o 0 60 120 180 3: Q O w Plan Scale: 1" = 60' O 0 = D_ — N PLANT SCHEDULE G Lu — Z oc Lu Q SYMBOL CODE QTY BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS SYMBOL CODE QTY BOTANICAL/COMMON NAME CONT N/A N/A Q 10— DECIDUOUS TREES SOD/SEED Q TR 68,392 SF TURF SOD RHIZOMATOUS SOD u + AU 34 ACER TRUNCATUM X PLATANOIDES 'JFS—KW187' 3" CAL. B&B 35'X20' CLASS II W W W RHIZOMATOUS TALL FESCUE URBAN SUNSET®MAPLE Q OTHER GINKGO BILOBA 'PNI 2720' EXISTING LANDSCAPE TO REMAIN ~ z + GP 55 PRINCETON SENTRY®GINKGO 2" CAL. B&B 45'X20' CLASS II EP2 5,672 SF PRESERVE AND PROTECT NONE 5'X6' z Q MALE VARIETY ONLY SEE KEY NOTES Lu SHRUBS, PERENNIALS, OR GRASSES U LIQUIDAMBAR STYRACIFLUA 'SLENDER ALL REQUIRED LANDSCAPE AREAS SHALL BE AT + LS 20 SILHOUETTE' 2" CAL. B&B 25`X15` CLASS II LEAST 70% COVERED WITH VEGETATION AT (/') COLUMNAR SWEET GUM MATURITY, WITH MULCH USED UNDER AND _ J SLS 11,956 SF AROUND THE PLANTS IN ACCORDANCE WITH J • PC2 16 PYRUS CALLERYANA 'CAPITAL' 2" CAL. B&B 35`X15` CLASS II UDC 1 1—3B-5N. ALLSTREET BUFERS SHALL BE C17o CAPITAL CALLERY PEAR PLANTED AT MIN. 1 SHRUB PER 7 FT PER o UDC 11-3B-7C 3 EVERGREEN TREES SHRUBS SIZE MATURE HXW 1 N CEDRUS DEODARA 'KARL FUCHS` JUNIPERUS HORIZONTALIS 'BLUE CHIP' 2 GAL. 1`X6` + CK 6 FUCHS DEODAR CEDAR 6'-8' B&B 15'X8' EVERGREEN BLUE CHIP JUNIPER ti JUNIPERUS SCOPULORUM `BLUE ARROW` 6'-8' B&B 12'X3' N BLUE ARROW JUNIPER EXISTING TREES PHYSOCARPUS OPULIFOLIUS 'SUMMER WINE` 2 GAL. 5'X5' o SUMMER WINE NINEBARK z EXISTING TREE TO REMAIN RHAMNUS FRANGULA 'FINE LINE' 2 GAL. 6'X3' ° SP 22 PRESERVE AND PROTECT EXISTING VARIES CLASS II FINE LINE BUCHTHORN a SEE TREE PROTECTION NOTES AND KEY NOTES ROSA X 'NOARE' 2 GAL. 3`X31 RED GROUNDCOVER ROSE o SPIRAEA X BUMALDA 'GOLDFLAME' 2 GAL. 3`X31 RM 11 EXISTING TREES TO BE RELOCATED EXISTING VARIES VARIES GOLDFLAME SPIREA z 5 RELOCATED TREE PERENNIALS SIZE MATURE HXW • PT 11 VARIES VARIES VARIES Z SEE KEY NOTES ECHINACEA PURPUREA 1 GAL. 5'X2' 3 TREE TO BE REMOVED PURPLE CONEFLOWER MITIGATION NOT REQUIRED HEMEROCALLIS X 'STELLA DE ORO' 1 GAL. 1'X2' LT2 6 SEE L4.0 EXISTING TREE INVENTORY AND EXISTING VARIES VARIES STELLA DE ORO DAYLILY E N G I N E E R I N G MITIGATION PLAN NEPETA X FAASSENII `JUNIOR WALKER' 1 GAL. 1.5' X 4' 5725 NORTH DISCOVERY WAY a JUNIOR WALKER CATMINT BOISE,IDAH083713 m N RUDBECKIA FULGIDA 'GOLDSTRUM' 1 GAL. 2'X2' PHONE(208)639-6939 CONEFLOWER kmengllp.com z SALVIA NEMOROSA 'MAY NIGHT' 1 GAL. 2'X2' MAY NIGHT SAGE DESIGN BY: MPH z GRASSES SIZE MATURE HXW DRAWN BY: MPH CHECKED BY: AY o CALAMAGROSTIS X ACUTIFLORA 1 GAL. 4`X2` DATE: 2/6/26 o 'KARL FOERSTER' FEATHER REED GRASS PROJECT: 25-243 w MISCANTHUS SINENSIS 'MORNING LIGHT' 1 GAL. 5`X4' EULALIA GRASS SHEET NO. z PANICUM VIRGATUM 'HEAVY METAL' 1 GAL. 4`X2' m BLUE SWITCH GRASS L 1.0 a N N N a "Stsssolluteseloo I I PLANT SCHEDULE NOTE: SEE L1.0 FOR FULL PLANT SCHEDULE ���` .�EOFID •., N I N I L I J �� r�: ���•���41$IO♦♦I 3 — / 7 - - I ° Q a \ \ SYMBOL CODE QTY BOTANICAL/COMMON NAME �•v�SS E •: • �,� \ I DECIDUOUS TREES \ i 0 8„W s„ s„W 8 s„W 8"W \N I N g'W $"W s„W s„W 8"W 8"W 8 8"W 8"W 8'W I • • • N I 8• ACER TRUNCATUM X PLATANOIDES 'JFS—KW187 • A-16 77 • 8's a"S _>�"s 8" I $ s a"s I + AU 34 URBAN SUNSET®MAPLE ' `ram•• 212226.• �,�•` s" s„S a„S 8"S s"S 8"S s„S s„ — — — — — — S ♦ •••••• • �•� '00' I E. WOODMURRA LN. PRIVATE '• •` °I ) _ I �• _ _ GINKGO BILOBA 'PNI 2720' ��#NDSCA4 2 — — — — — — — — I \ GP 55 PRINCETON SENTRY®GINKGO ������������, Q P *RR y y y y y y y y r d N y y y y y y +y ° O y +y y y y y y y I MALE VARIETY ONLY d y 8�• $»W 8"W $"W g"W LIQUIDAMBAR STYRACIFLUA 'SLENDER Q s 1 I ll11PP y y y}y T d y +7' y y y y y y y y I + LS 20 SILHOUETTE' 76 y y y+ y (0 I L — "PI I 2 COLUMNAR SWEET GUM 4"PI y y y y y y• y =- R Q Sp Q T-1 —4' , R y" y y "yl 84 y ° y•y y ° y ' y y y y I' • PC2 16 PYRUS CALLERYANA `CAPITAL` ° y y y �, �, y y I CAPITAL GALLERY PEAR •. y yly S d� ° y y y y y y y y y y I EVERGREEN TREES F y y y y y y y y • y I Q 1 BLOCK 1 y "" y O s °3 y y y y y y y y y + CK 6 CEDRUS DEODARA 'KARL FUCHS' y y ° FUCHS DEODAR CEDAR 3 I 74 yy �w yyyyyyyyy y y yy EXISTING TREES N {c EXISTING TREE TO REMAIN Q y y00 � 82 �� a3 �y y y y y y y y y y y y y y I SP 22 PRESERVE AND PROTECT a0 y �= PI _ ° �y y y y y y I ' SEE TREE PROTECTION NOTES AND KEY NOTES y Co y y Q I y� Q ° y y y y y y M I y I w y y y y y y y y y y y y RM 11 EXISTING TREES TO BE RELOCATED Ln �/, y I O N 73 10 y y W d y y y y Oy y (n I Z 13 � 00 I I +y > yO ° �y y y y y y y y y y y v y y y ifl • RELOCATED TREE O Q Co y PL. y 81 $ y y y y I ' PT 11 SEE KEY NOTES (/I w W 85 ° yy y y yy 86 y yy > s z I y y y y yy y TREE TO BE REMOVED = N y I0 ° y+ w 4d y y y y y y I ' MITIGATION NOT REQUIRED 3 I I Q w Q y y y y y y n I LT2 6 SEE L4.0 EXISTING TREE INVENTORY AND OO y ® y W ° y y y y y y y 5 �� 172 I �y y y y y ® y y y J ' MITIGATION PLAN ° � d y y y y y 'SD y y y y y I Ry I _ ° Co Co �13 y12' y y SYMBOL CODE QTY BOTANICAL/COMMON NAME d Lu y gp + d y PI I I y y, N y z y SOD/SEED y '� y y J zj y ° y 9 y W V~y ` y y y y y y y y y I I� ° Q� ° +y '� d I �y y 6 y y V'I TR 68,392 SF RHZ OMATOUS F SOD ITALLA FESCUE C. OTHER Lu +y y EXISTING LANDSCAPE TO REMAIN Q y yy yn° 79 P� 5 y y y y y y y EP2 5,672 SF PRESERVE AND PROTECT z y ly SEE KEY NOTES O I s 3 sy y y y y ys'sy y a y y y y y y y l y y y SHRUBS, PERENNIALS, OR GRASSES y l I y y 12"sD y y y y y y y y y y y y y ALL REQUIRED LANDSCAPE AREAS SHALL BE A Q V, O ° 3 I O y y y y y y y y y y y y y y y y y O y y y y y y y d 7 y y y y y y y y y y y y V� y y y I 7 70 +y oP>— — I y LEAST 70% COVERED WITH VEGETATION AT MATURITY, WITH MULCH USED UNDER AND I y y y y y y y y y Oy y y y y y y ° y y y y y y y Dy y y y y SLS 11,956 SF AROUND THE PLANTS IN ACCORDANCE WITH Q® UDC 1 1-3B-5N. ALLSTREET BUFERS SHALL BI - M PLANTED AT MIN. 1 SHRUB PER 7 FT PER � PI y+ y y d UDC 11-3B-7C y y Iy y y y' 10 y y O I 69 + I W ° , y I �� °� I Qy N KEY NOTES (TYPICAL) ® z �d y 4 E. KALINGA LN. (PRIVATE) I 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE 00 3 y I ' W AT ALL TREES WITHIN TURF AREAS. O Q I 2. CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR 65 y y y y y y y y yI y y y y y y y y y y y I 1 W VISION TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER y y . y y . �y y y y y y+y y AT MATURITY WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ° ° ' Z_ ADJACENT STREET GRADE. Q � Q J _ � PI ' I y = 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH OF 1" BLACK AND TANou m ' V ROCK MULCH WITH PERMEABLE FABRIC WEED BARRIER. THE USE OF MULCH D Q y I OR ROCK AS THE ONLY GROUND COVER IN REQUIRED PLANTING AREAS IS J I Q PROHIBITED. IMPERMEABLE PLASTIC WEED BARRIERS ARE PROHIBITED. 67 y Q 00 3 y rn y cc t I ° BLOCK 1 G 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. I„V I I ° 3 Iy ' 5. INSTALL FLAT—BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER 2 z y I I y o N Iy z BED. SEE L5.0-03. O Q w Z � 0 y y CO y w 1 6. PAVILION. SEE L5.0-02 REFERENCE IMAGE. _ — Q 00 y Lu I 11 3 7 66 y 64 63 62 61 60 59 58 57y 7. MICRO PATHWAY. SEE CIVIL PLANS. z Z > • ° y Iy m ' � Q QLLJ � PI y y 7 0 8. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN Q 3 y y y y y y y y y y y y y 1 y y N' THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR U N y y y y y y y y y y y y y J y y_00 iq �, FACILITIES. 0 0 u 4'2,•S.y( y y y y y y y y y y y y N y inL > C Q ����.�D.�w_1�,sDy y y y y +y y y y y y y I I y ' 9. EXISTING TREES TO BE REMOVED. SEE PLANT SCHEDULE AND L4.0 EXISTING 3 wv y y y y y\�I` y y , y y y TREE INVENTORY AND MITIGATION PLAN. w G Z I s»,u y\y\y y y y y \ S y I yl ' 1 1 1 J 00 ° d •tl Q §""w�\ y W �"W yz y y y y -Ina10. EXISTING TREES TO BE RELOCATED. SEE PLANT SCHEDULE AND L4.0 �i (�}v\ T EXISTING TREE INVENTORY AND MITIGATION PLAN.— — — — — — — - -00 8•• °8. °s Q y y — — — 7 ILL ° a� ° Q ° „ I 11. RELOCATED TREES. RELOCATED TREES SHALL BE INSTALLED IN APPROVED U ° ° _ $s ° ° $w w° $W Q $W w ,8 W w a $w 8 ° 8'W w LOCATIONS PER DEVELOPER AND MAINTAINED FOR ESTABLISHMENT. \ b ° F� �P� ''S ° °� ° ° d ° a ° d ° ° I I TEMPORARY PROTECTION SHALL BE PROVIDED UNTIL RELOCATION IS 6'0� ? ° ` \s'yo� 8"'s ° ° ° ° d I a0 I ' COMPLETE. SEE TREE PROTECTION NOTES. 13 �� 40 I 12. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND sp ° y y s"PI —" I 6"PI s" s"PI PI s"PI P s"PI s"PI " ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF z Q - - — — — — IRRI I p ° ya y N I DISTURBANCE AND PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. L1J J °°' y y 00 ' TRANSITION BETWEEN NEW AND EXISTING LANDSCAPE SHALL BE NON U RECOGNIZABLE AND COHESIVE WHEN FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE PLANTING AREAS AND V� y y y y y y y y y y y y ° IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION. J 9- w y y s'i y 1 y y y y y y Iy 'd y y 0 y I THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM J REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING G 'y y y y 4Uy'�� y y y y y y y ° �'�p y 16 17 y Iy a0 I 1 CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR 3 BETTER THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL O •Q y y y y I�\/ y y y y y d y y 18 REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS 3 8" y y y y y y \ p� R S y � y 19 y I DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE 8" w y Ty d ° y 20 21 22 23 24 25 26 27 y CONTRACTORS FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM \80, y W y y y y y ,y y ,, y ° 00 s�.,� y�� y iy 00 I ' DURING THE COURSE OF CONSTRUCTION. W y y Oy - 8•� \�•, Iy y ° y y yIy I 13. EXISTING TREES TO REMAIN. SEE TREE PROTECTION NOTES. p R + \ YY\ y �° y y 15 V' V' \ \ 3 I�' Li- Q) Q y y 8•• Co y y y s ly W y \ 15"GI - - _ — �Iy P41y y y „ w o �� y 8S y y y \ GI 75'"GI II 5 < *° y y y 15" I 15"GI 15"GI 15"GI 15"GI� 15" I 12"GI 2"G y C Amok 2 y y y W y y d y .J T .�._ —y- —6 d � ` C 1 ,� ° y1 O"�D VI s"J� y I y y Y I� y 4 I� Ny y y y y V® y 18 S D y y 1 a'J D y U y y 0 P P z EP y y y 3 12"sD y+ y y 12"SD N E N G I N E E R I N G v � (�A y y y y z " e t A�y y y y A-y y y y y yy y 8 5725 NORTH DISCOVERY WAY Q \ \ y } y y y 1 E. HILL PARK ST. 4 ;� BOISE,IDAHO 83713 PHONE(208)63o9-6939 /y y y % } y y FCA p � y W y+y y y y y y y y DESIGN BY: MPH z Q \ EP y y y y y y y y y y y y y y y y y y y y y y y y y y y y y y FP EP�•L y y y y y y y y y y V y y y y y y y y y y y y y y y y y y y DRAWN BY: MPH R Ep f2°S 12°SD O \ y y y y y y y y �7 V+y y y + y yy y y y EP El'_ E p y y y y — y y y EP CHECKED BY: AY y y y W W y y y y y y y y y y O 0 EP EP�EP y —E EP Eta ' DATE: 2/6/26 o Q 36"GI —36"GI 36"GI— —36"GI 36"GI 36"GI 36'GI 36'GI �36 Gi— GI EP 36"GI 36"GI 36"GI 36"GI 36"GI 36"GI7�3BE(� WGI IR� 0 LANDSCAPE PLAN SHEET NO. 2s243 z 0 30 60 90 •O a Plan Scale: 1" = 30' N a .•` E O F ID ••, PLANT SCHEDULE NOTE: SEE L1.0 FOR FULL PLANT SCHEDULE •`• `SQ' 0•0•00•`9� ��• SYMBOL CODE QTY BOTANICAL/COMMON NAME DECIDUOUS TREES 5601, L -1657 • ACER TRUNCATUM X PLATANOIDES 'JFS-KW18i ��� 121 •'� �•� + AU 34 URBAN SUNSET®MAPLE *00000 gNDSCAQ GINKGO BILOBA 'PNI 2720' + GP 55 PRINCETON SENTRY®GINKGO MALE VARIETY ONLY LIQUIDAMBAR STYRACIFLUA 'SLENDER + LS 20 SILHOUETTE' 1 COLUMNAR SWEET GUM • PYRUS CALLERYANA 'CAPITAL' PC2 16 1 I CAPITAL CALLERY PEAR ILu 1 00 I EVERGREEN TREES a CEDRUS DEODARA 'KARL FUCHS' 1 I + CK 6 FUCHS DEODAR CEDAR I CoI EXISTING TREES 1 EXISTING TREE TO REMAIN 1 SP 22 PRESERVE AND PROTECT 3 I SEE TREE PROTECTION NOTES AND KEY NOTES I 1 I RM 11 EXISTING TREES TO BE RELOCATED z O 1 U Nun PT 11 RELOCATED TREE W / SEE KEY NOTES w TREE TO BE REMOVED r712"S 1 2"SD I � � MITIGATION NOT REQUIRED w+ n I — LT2 6 SEE L4.0 EXISTING TREE INVENTORY AND U MITIGATION PLAN s a"s 8°S 8"s 8"s 8"S I SYMBOL CODE QTY BOTANICAL/COMMON NAME 5 3Lu SOD/SEED N IF - - - - - - - - - - - - - - — — — — — — — — — — — � y TR 68,392 sF TURF SOD RHIZOMATOUS W \ I 0 RHIZOMATOUS TALL FESCUE W W W 12"w 12"w 12"w \ J I I OTHER o \ J I W W W J W W J W y y W i i W . W W . W W . W . J� W y i W i W W W W I W W \ / I I EXISTING LANDSCAPE TO REMAIN z I WW WyWWWyWyWWWyWWWWWyWWWyWyWWWyWyWWWyWyWWWyWWWWWyWWWyWyWWWyWyWWWyWyWWWy WWW W W W W W v EP2 5,672 SF PRESERVE AND PROTECT V) SEE KEY NOTES W IW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W . W W W W W ry W W I 00 I SHRUBS PERENNIALS OR GRASSES ALL REQUIRED LANDSCAPE AREAS SHALL BE A W W W W W W W W W W W W W W y W W W W W y W W W y W W W W W W W W W W W y W y W W W y W W W W W y W W W y W y W W W W J y W W W W W W W W W y W W W W W W W W W y W W W W W W W W W W W W W y W W W y W W W W W y W W W y W W W W W?W W \W\\ I LEAST 70% COVERED WITH VEGETATION AT SLS 1 1,956 SF MATURITY, WITH MULCH USED UNDER AND AROUND THE PLANTS IN ACCORDANCE WITH °d J/° ° ` d ° ° W W\W ,� � I UDC 1 1-3B-5N. ALLSTREET BUFERS SHALL BI W ® 1E"SD 4s"SZ��as"sa 1$ W W W W W W W W w W �W W u \ PLANTED AT MIN. 1 SHRUB PER 7 FT PER W+ + W \ I UDC 1 1-3B-7C W W W W W W W W W W W W I \ W I I00 1 3 I \ y KEY NOTES (TYPICAL) ® 0 O 00 I � E. KALINGA LN. (PRIVATE) 1 4 \ I W I — \/ — — — — — — — — — — — — — — — - 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE Ln J 1 i I I\\� Id ) AT ALL TREES WITHIN TURF AREAS. \ 2. CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR W I Why W W W W+ W W + W W W +W W W W + W W WSW W y W W W W+W W W W W W W i W �. VISION TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER 0 W 1 ° d ° d ° ° W W W W I I I v AT MATURITY WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE z I� ADJACENT STREET GRADE. 0 Q W W I W I W m I I N 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH OF 1" BLACK AND TAN J N W I I I I ROCK MULCH WITH PERMEABLE FABRIC WEED BARRIER. THE USE OF MULCH y yIv w� °I I OR ROCK AS THE ONLY GROUND COVER IN REQUIRED PLANTING AREAS IS w W LuW 5 BLOCK 1 PROHIBITED. IMPERMEABLE PLASTIC WEED BARRIERS ARE PROHIBITED. z z IQ W I w I N I I 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. W J >3 y W I � I I 0 0 a: a0 W W W W I I 5. INSTALL FLAT-BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER Q = a � BED. SEE L5.0-03. L u z z 56 55 54 53 52 51 SO 49 48 47 46 45 44 43 W I J I N I I 6. PAVILION. SEE L5.0-02 REFERENCE IMAGE. Q 0 Lu I= I I I Lu 7. MICRO PATHWAY. SEE CIVIL PLANS. 0 0 IIDL U '0 W y 3 y W I I wY I I I 8. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN 0 1m •W W I I THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR LJ..I Z 1 10 I N I FACILITIES. — Q 5 y s s 4 I vi I I 9. EXISTING TREES TO BE REMOVED. SEE PLANT SCHEDULE AND L4.0 EXISTING W J 11 2 I I I I I TREE INVENTORY AND MITIGATION PLAN. — — — — — %7— .8"A ILL — 10. EXISTING TREES TO BE RELOCATED. SEE PLANT SCHEDULE AND L4.0 U EXISTING TREE INVENTORY AND MITIGATION PLAN. �8.'w 8" 8. d8..w ° 8'wd 8..w 8.. 8..w 8.� 8"w 8" d 8 w sdw 8"� s"w ..w 'w N II W ° ° ° d dZ I I 11. RELOCATED TREES. RELOCATED TREES SHALL BE INSTALLED IN APPROVED 0 0 d a ° ° a ° ° ° ° d� °a ° a ° ° a I LOCATIONS PER DEVELOPER AND MAINTAINED FOR ESTABLISHMENT. z - 8' s"s ° "s s'° ° s° �" s"s a"s ° a's �" "s d s"S-- ° s'� s" ° 8"S a°s s ° I I I I I TEMPORARY PROTECTION SHALL BE PROVIDED UNTIL RELOCATION IS ° ° COMPLETE. SEE TREE PROTECTION NOTES. z Q 6' 1 _6"PI "PI — 6"PI, 6 — 6"PI _ 6"PI 6"P 6"PI 6"PI 6" _ PI — 6" 6"PI _ "PI— — I I I I N — — — — — — �° — — �"— — — — — O- — — I I 12. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND Lu II I I I I ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF u NI I I I DISTURBANCE AND PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. (/') li Co 4W + I I TRANSITION BETWEEN NEW AND EXISTING LANDSCAPE SHALL BE NON J W J I I RECOGNIZABLE AND COHESIVE WHEN FINISHED. CONTRACTOR IS J RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE PLANTING AREAS AND W W I I N IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION. 11 W I I THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM of ® ro REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING II W W I I I CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR ° I I BETTER THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL g I 28 29 30 31 32 33 34 35 36 37 38 39 40 41 I I N REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS N �•W W :W {� I I ° I I DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE 113 W W N o I I CONTRACTORS FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. 0 I Co f II W I I o W 13. EXISTING TREES TO REMAIN. SEE TREE PROTECTION NOTES. W I I y + I 3 I I — — — — — — — — — — — — — — Z 6" 1 I6 PI 6"PI 6"PI 6"PI E g 12"Gl,I 12"GI 12"GI 12"GI 12"GI 12" 12"GI 12"GI 12"G 12"GI 12 GI 2"GI 12"GI 12"GI 2"GI a d �'GI 1 �12"GI 12"GI 12"GI— U � z P.ii Pxx 3 E N G I N E E R I N G s"w s"w s"w s"w s"w 8"w 8"w s"w s"w " " " sw s"w sw sw s"w s"w s"w s"w "w 12"w 12"w 12"w 12"w 5725 NORTH DISCOVERY WAY a 1 2 12 1 3 °' BOISE,IDAHO 83713 E. HILL PARK ST. PHONE(208)639-6939 N N 3 a 8°S 8"S 8"S 8"S 8"S 8"S 8'S— 8"S— 8"S 8'S 8"S 8"S 8"S 8"S 8'S S"S 8'S 8"S 8"S 8"S 8"S 8"S kmengllp.com — DESIGN BY: MPH 0 DRAWN BY: MPH D z CHECKED BY: AY z LANDSCAPE PLAN DATE: 2 PROJECT: 25-2435-243 w 0 0 30 60 90 SHEET NO. Z m Plan Scale: 1" =30' L3.0 a N N N a ••.•�P�E 0 F IDq •.,. a V TREE REFERENCE IMAGES- TYPICAL SAMPLE s .. �SSAY O73 rn • " '� • 1 2 3 4 5 L 165 6 7 8 9 10 11 12 13 14 15 16 17 �.. r ,`f �'• 2/12/ Fj, '� •' 7 • � : �= �� •`9NDSCA `•• •• C, a Q - LLJ Lu J mw Ln z 0 EXISITI NG TREE INVENTORY AND MITIGATION PLAN t r X Lu Lu 0 20 40 60 TREE #1 - POOR TREE #7 - POOR Plan Scale: 1" = 20' NOTES: NOTES: SUCKERING. CALIPER 4" SUCKERING, DEFORMED LEAVES. CALIPER LESS THAN 4". EXISTING TREE INVENTORY AND ANALYSIS GENERAL NOTES: CONDITION DEFINITIONS: 1. TREE INVENTORY AND ANALYSIS PREPARED IN CONJUNCTION WITH CERTIFIED 1. GOOD CONDITION: A TREE IN GOOD CONDITION IS HEALTHY, STRUCTURALLY TREE # TREE TYPE SIZE (CAL.") CONDITION ACTION MITIGATION ARBORIST, MADISON HOLMES, PN-10253A SOUND, AND EXHIBITS VIGOROUS GROWTH. IT SHOWS NO SIGNIFICANT SIGNS OF YES/NO STRESS OR DAMAGE AND HAS AN OPTIMAL CANOPY DENSITY AND COLOR. 2. ALL TREES WERE MEASURED USING A CALIPER TOOL; TREES WERE MEASURED AT OR 1 PLUM 4.0 POOR REMOVE NO ABOUT 4.5' ABOVE GROUND. 2. FAIR CONDITION: DEFINITION: A TREE IN FAIR CONDITION IS GENERALLY HEALTHY p BUT MAY SHOW SOME SIGNS OF STRESS OR DAMAGE. IT IS STRUCTURALLY SOUND z 2 CEDAR 4.0 GOOD RELOCATE NO 3. ALL TREES WITH A CALIPER OF 4" OR LESS SHALL NOT REQUIRE MITIGATION PER BUT MAY HAVE MINOR ISSUES THAT NEED MONITORING OR INTERVENTION. CITY OF MERIDIAN CODE 3 PINE 4.0 GOOD RELOCATE NO 3. POOR CONDITION: A TREE IN POOR CONDITION EXHIBITS SIGNIFICANT HEALTH , 4. ALL TREES IN GOOD TO FAIR CONDITION PROPOSED FOR REMOVAL SHALL REQUIRE PROBLEMS, STRUCTURAL ISSUES, OR BOTH. THESE TREES ARE OFTEN STRESSED 4 CEDAR 4.0 GOOD RELOCATE NO MITIGATION UNLESS OTHERWISE APPROVED BY COMMUNITY FORESTRY. SEE AND REQUIRE INTERVENTION TO IMPROVE OR STABILIZE THEIR CONDITION. 5 CHERRY 3.0 POOR REMOVE NO EXCEPTION ABOVE. 4. DEAD CONDITION: DEFINITION: A TREE CLASSIFIED AS DEAD SHOWS NO SIGNS OF . . 5. ALL TREES IN POOR, OR DEAD ARE NON-DESIRABLE AND SHALL NOT REQUIRE LIFE. IT HAS CEASED TO GROW AND LACKS VIABLE FOLIAGE, AND ITS STRUCTURAL 6 CRABAPPLE 4.0 GOOD RELOCATE NO MITIGATION UNLESS OTHERWISE REQUESTED BY COMMUNITY FORESTRY. INTEGRITY IS COMPROMISED. 7 CHERRY 3.0 POOR REMOVE NO 6. PER CITY CODE, BEFORE ISSUANCE OF THE FINAL CERTIFICATE OF OCCUPANCY, A = _ 8 CEDAR 4.0 GOOD RELOCATE NO LICENSED LANDSCAPING PROFESSIONAL SHALL SUBMIT TO THE CITY CERTIFICATION THAT THE LANDSCAPING HAS BEEN INSTALLED IN COMPLIANCE WITH THE APPROVED 9 PINE 4.0 GOOD RELOCATE NO PLANS. CERTIFICATION SHALL DEMONSTRATE THAT A CERTIFIED ARBORIST HAS BEEN z CONSULTED. O 10 CEDAR 4.0 GOOD RELOCATE NO A 11 CHERRY 3.0 POOR REMOVE NO } 12 CRABAPPLE 4.0 GOOD RELOCATE NO 13 CHERRY 3.0 POOR REMOVE NO X m z 14 CEDAR 4.0 GOOD RELOCATE NO Z 15 PINE 4.0 GOOD RELOCATE NO 16 CEDAR 4.0 GOOD RELOCATE NO � � V) Q 17 PLUM 4.0 POOR REMOVE NO TREE #8 - GOOD No EE #9 - GOOD Lu z C7 NOTES: 2 w t: CALIPER 4". TREE TO BE PRESERVED AND RELOCATED. CALIPER 4". TREE TO BE PRESERVED AND RELOCATED. O Q G I.0 zz > Q O O 0 = oc � O SYMBOL LEGEND AND TOTALS � � � w Lu z oC w z SYMBOL DESCRIPTION CAL.INCHES LL Q W EVERGREEN DECIDUOUS U Lu EXISTING TREES TO BE RELOCATED Q Ur R R PRESERVE AND PROTECT 44 INCHES W: - SEE TREE PROTECTION NOTES ON L1.1 AND GENERAL NOTES THIS SHEET z Q F- J LJJ X M p �� ULu EXISTING TREES TO BE REMOVED �N � ; 0 MITIGATION NOT REQUIRED 20 INCHES J SEE GENERAL NOTES #3-5 THIS SHEET 3 J U - a 0 O l7 }• N ti {{ N V1 TREE #12- GOOD o NOTES: o CALIPER 4". TREE TO BE PRESERVED AND RELOCATED. 0 s a 3 0 z 3 a a a V N z Z 3 0 E N G I N E E R I N G w 5725 NORTH DISCOVERY WAY m BOISE,IDAHO 83713 PHONE(208)639-6939 z kmengllp.com z a a DESIGN BY: MPH z DRAWN BY: MPH V 7 CHECKED BY: AY z DATE: 2/6/26 0 PROJECT: 25-243 0 SHEET NO. z m L4. N 2 �.`'` `tE 0 F�� •'•. % zSSA YE GENERAL IRRIGATION NOTES GENERAL LANDSCAPE NOTES * % S 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS idolCORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY LANDSCAPE PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF : lnn (� A-16 7 DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE THE LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT dop CONTRACTOR'S RESPONSIBILITY. IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. REMOVE DEAD/ DAMAGED ; %� ��?,/12 2%0 C,��.' CH ATE WATER COVERAGE TO ALL LAWN AND THIS INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED BRANCHES AND PRUNE TO •• NDS CA •'��, 2 SYSTEM WHICH R IS PROVIDESADEQBLE TNISH AND NALL AEPLANTNG IRRIGATION OR SOD, EDGING, AND DRIP LINE QUANTITIES. INTERNATIONAL SOCIETY OF i ••••��������•NN�`'` ARBORICULTURE STANDARDS; r AREAS. THE WORK SHALL CONSIST OF PROVIDING AND INSTALLING ALL MATERIALS 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF IMPROPERLY PRUNED TREES NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT OF CONNECTION, PIPE, VALVES, AVAILABLY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A p (AS DETERMINED BY THE FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR. THE CONTRACTOR SPECIFIED PLANT IS NOT AVAILABLE, THE LANDSCAPE ARCHITECT WILL PROVIDE SHALL FURNISH THE LANDSCAPE ARCHITECT WITH A SHOP DRAWING SHOWING THE ALTERNATE PLANT MATERIAL SELECTIONS. SUCH CHANGES SHALL NOT ALTER THE p LANDSCAPE ARCHITECT) O DESIGN LAYOUT, PIPE SIZE AND TYPE, VALVE LOCATIONS AND TYPE, HEAD LOCATIONS ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER. p O SHALL BE REMOVED AND - AND TYPE, CONTROLLER LOCATION AND TYPE, WIRE SIZING, ETC... FOR APPROVAL PRIOR (2)-BVC WOOD TREE oG 0607 p REPLACE. r TO CONSTRUCTION. 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD STAKES(MIN. 6' HT) p TRUNK FLARE. LOCATE PRIOR UTILITIES WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG CHAINLOCK p000 p TO PLANTING. FLARE SHALL 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK LINE, INC. © 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF TREE TIES p BE VISIBLE AFTER PLANTING. UTILITIES AND SERVICES DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING 6" MULCH PER PLAN KEEP u, 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS. SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE. MIN 1"-2" AWAY FROM TRUNK o 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES. 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION 3 FLARE 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER FOR OF THE CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS FINISH GRADE PREVENTION OF BACKFLOW AND BACK-SIPHONAGE THAT REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE 3' TO NOTIFY THE RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS 3" HT. WATERING BASING 7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED EXISTING CONDITION. BALL - I BERM PAVILION PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS DEPTH - = FERTILIZER TABLETS 02 NTS APPROPRIATE. 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED FOLD BACK BUR FROM LAP AREAS. ALL DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, TOP 3 OF ROOTBALL. 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL I iI Ii iI�i I I i i I i REMOVE WIRE BASKET AFTER MULCH AT OPERATIONS. FINISH GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW PLANTER RATES WITHIN EACH CONTROL VALVE. .PLACEMENT IN GROUND AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE. NOTE: REMOVE TREATED ROOT- TURF 8" BEDS N 9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER OR SYNTHETIC BURLAP BALL BACKFILL SOIL MIX GENTLY Z DEMAND AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL WIDTH PACK BACKFILL USING WATER O_ COMPLETELY. REMOVE SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE / TO SETTLE SOIL AROUND 44ly I v�THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS. ANY SOIL AND ORg INCH IN SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. ROOTBALL _ _ _ _ _ LL, MULCH AWAY FROM 8" MIN 8" MIN _ _ _ - '� PLANTING PIT ROOTBALL ON UNDISTURBED -�I- � W ~ 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO TREE CROWN AFTER SOIL 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC PIT SHALL BE A MIN. 2 TIMES WIDER IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING AREAS. INSTALLATION. MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN THAN ROOTBALL AT BASE AND A MATERIALS AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE MIN. 3 TIMES WIDER THAN ROOTBALL o 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO FURNISH MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED AT FINISH GRADE. DEPTH SHALL BE AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER IMPORTED TOPSOIL OR, AMEND THE ON-SITE TOPSOIL. SAME AS THE ROOTBALL. FINISH COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS THAN NOTES: GRADE IIII-III- I �- TOPSOIL ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE ARCHITECT IS 8, TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.; 1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS. PLANTER BEDS - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE 0STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. CUT EDGE TREATED WITH A PRE-EMERGENT HERBICIDE. DECIDUOUS TREE PLANTING AND STAKING DETAIL SHOVEL CUT EDGE 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND VAULTS g FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH WITH DURABLE TAGS CARRYING THE WARNING "DANGER-UNSAFE WATER OR POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF NTS 03NTS NON-POTABLE WATER." AREAS SHALL NOT EXCEED 3:1. o z 13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, 6" RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS. INSTALLATION OF PLANT MATERIALS AND MULCH. 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS SINGLE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY ACCESSORIES. GROWING CONDITION. 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO BE 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER USED IN ALL PLANTER BEDS. PORTION OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED BACK AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER VELOCITY LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS IN ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE SIZE TO BE PRIOR TO BACKFILLING. z 1 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING O 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY, PARKING, AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND AND WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE. IDENTIFY DEAD OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND ENDPOINTS OF SLEEVING. SPECIES AT NO COST TO THE OWNER. > 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER 0 (/) VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD MANUFACTURER'S RECOMMENDATIONS. m z SURFACE. 15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: D Q 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND (/') ALL REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. 0 PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE SIZE WIRE AND CONDUIT AS REQUIRED. INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS V) AND DISEASE UNTIL FINAL ACCEPTANCE BY OWNER. Lu 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS z DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. 0 RE-SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. Lu Ln REPAIR INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS, O Q J CONTROL WIRES AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR 0 RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE _ _ :2 < SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING DEAD MATERIAL. Lu CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM z -j > W OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. 0 TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY NEEDED. \5 Lu 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS _ � DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS O 0 CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF • Q APPARENT AND WEATHER AND SEASON PERMIT. CONSTRUCTION. c LA 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN ACHD LANDSCAPE NOTES Lu c 0 DRAWINGS AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL 5 z INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM w Q CONTACT THE OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR. DRAIN PIPE, STRUCTURES, OR FACILITIES. Q LL 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL PROVIDE 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE QU A NEAT AND LEGIBLE AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND MAINTENANCE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. u MANUAL, AND UP TO (8) HOURS OF ORIENTATION AND/OR TRAINING FOR THE OWNERS MAINTENANCE AND OPERATIONS STAFF. 3. ALL TREES SHALL BE PLANTED A MINIMUM OF 5' FROM ALL ACHD CURBS AND/OR cl 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ATTACHED SIDEWALK, UNLESS PLANTED WITHIN THE PARKSTRIP. ALL TREES PLANTED IN z IT'S ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR PARKSTRIP SHALL BE CENTERED. z Q SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO w J THE OWNER. TREE PROTECTION NOTES U 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND 1. THE CONTRACTOR SHALL TAKE EXTREME CARE TO PROTECT THE CRITICAL ROOT ZONE WINTERIZATION DURING THE GUARANTEE PERIOD. OF ALL TREES AT ALL TIMES THROUGHOUT PROJECT. J J 2. PRIOR TO COMMENCING WORK, TEMPORARY FENCING SHALL BE INSTALLED IMMEDIATELY AROUND EACH TREE IMPACTED BY DEMOLITION OR CONSTRUCTION. FENCING SHALL BE MAINTAINED THROUGHOUT THE COURSE OF THE ENTIRE DEMOLITION AND CONSTRUCTION PROCESS. 3 3. BULK MATERIAL, EQUIPMENT, VEHICLES, AND CONSTRUCTION DEBRIS AND WASTE SHALL NOT BE STOCKPILED WITHIN THE CRITICAL ROOT ZONE. ti N 4. COMPACTION BY EQUIPMENT TRAFFIC IS PROHIBITED WITHIN THE CRITICAL ROOT w ZONE. Z 5. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE. APPLY A MIN. 1.5" OF WATER OVER THE CRITICAL ROOT ZONE PER WEEK. THIS IS A MIN. RECOMMENDATION. a CONTRACTOR IS RESPONSIBLE TO DETERMINE IF MORE WATER IS NECESSARY DURING CONSTRUCTION. 3 6. ANY DAMAGE TO EXISTING TREES DURING CONSTRUCTION SHALL BE THE g CONTRACTORS RESPONSIBILITY. THE CONTRACTOR SHALL PERFORM REMEDIAL WORK w TO DAMAGED TREES AT THE CONTRACTOR'S EXPENSE. a U 0 Z 3 0 E N G I N E E R I N G w 5725 NORTH DISCOVERY WAY a BOISE,IDAHO 83713 m N PHONE(208)639-6939 kmengllp.com z a DESIGN BY: MPH z DRAWN BY: MPH CHECKED BY: AY z DATE: 2/6/26 0 PROJECT: 25-243 w 0 SHEET NO. z a L5.0 N N N a