HomeMy WebLinkAboutC6.02 Pressure Irrigation Main 1 I Pressure Irrigation Notes: _ �.� /�►,� 1. INSTALL ALL CROSSINGS OF THE PUBLIC RIGHTS-OF-WAY, PRIVATE ROADWAYS ��//► THE AND TRAVELWAYS WITH PRESSURE IRRIGATION AT A MAXIMUM DEPTH OF TWO-AND ONE-HALF(2-1/2) FEET AND IN AN AWWA C-900 PIPE SLEEVE WITH LAND LOCATOR WIRE.THE PUBLIC WORKS DEPARTMENT AND ACHD SHALL INSPECT- - - - � ALL CROSSINGS PRIOR TO BACKFILLING. %m9wwp -r GROUP 1 I I 1 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE INSTALL-6-IN GATE VALVE PRESSURE IRRIGATION WATER MAINS (SANITARY SEWER, STORM DRAIN,AND IRRIGATION) SHALL BE PRESSURE IRRIGATION SLEEVE INSTALL-6-IN GATE VALVE P2 I W/THRUST BLOCKS RISER (TYP). SEE SHEET C6.03. A MINIMUM OF TEN (10) FEET.WHERE IT IS NECESSARY FOR A POTABLE 1 WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN (TYP). SEE SHEET C6.03. W/THRUST BLOCKS I I EIGHTEEN (18) INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE 1 Ep PRESSURE IRRIGATION SLEEVE 1 CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES 290-LF 6-IN PI I 69-LF 6-IN PI (TYP). SEE SHEET C6.03. 449-LF 6-IN PI FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)AND SECTION 430.02 6"PIRR 6"PIRR 6"PIRR X 6"PIRFs 6"PIRR 6"PIR 6"PIRR 6"PIRR 6"PIRR 6"PIRR 6"PIRR - - — — — — — — — — — OF THE WASTEWATER RULES (IDAPA 58.01.16). - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ——— — — — — — —— — — — — — —— — — — — — — — — — — — — — — —— — — —— — — —— — — — ' � I 111 M P1 O° I II 1 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE j WATER SERVICES OR POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX(6) II �„ FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND ff to NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) 3/W R/W R/W R/W — — — — — �/ _ _ _ _ — — — — — — — R/V R/W R/W R/W FVtR/W R/uv R/W INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN 12 W 12"W 12"W 12"W ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC 12"W 12"W 12"W 12"W 1 "W 12"W X 12"W 12"W ( ) DRINKING WATER SYSTEMS IDAPA 58.01.08 AND SECTION 430.02 OF THE 1 X 1 CO) WASTEWATER RULES (IDAPA 58.01.16). m 4. INSTALL FINDER TAPE WITH ALL IRRIGATION MAINS. TAPE SHALL BE TWO (2) m _ _ c _ _ _ _ _ _ _ _ _ _ _ _ _ _ m _ _ INCHES WIDE, METALLIC RED IN COLOR,WITH THE WORDS DANGER-UNSAFE L 100 33+00 32+00 31+00 30 0i'b WATER OR NON-POTABLE WATER CLEARLY MARKED ALONG ITS LENGTH. h SAN 8"SS 8"SS 8"SS 8"SS 8"SS 8"SS "SS 8"SS SAN 8"SS o 8"SS PLACE THE TAPE BETWEEN SIX(6) INCHES BELOW THE SURFACE AND y PRESSURE IRRIGATION SLEEVE PRESSURE IRRIGATION SLEEVE EIGHTEEN (18) INCHES ABOVE THE TOP OF THE PIPE. (TYP). SEE SHEET C6.03. W. Grand Mogul Dr I 5. LABEL ALL IRRIGATION RISERRS AND FAUCETS WITH DURABLE TAGS (TYP). SEE SHEET C6.03. CARRYING THE WARNING DANGER-UNSAFE WATER OR NON-POTABLE WATER. i W R/W R/W R W R/W R/W R/W R/W R/W R/W R/W _ � I � 6. LABEL ALL VALVE BOXES AND VAULTS WITH DURABLE TAGS CARRYING THE WARNING O DANGER-UNSAFE NON-POTABLE I I 1 I I AND BO ES ARE TO BELOCATED A MINIMUM OF EN (10) FEET OUTSIDE OF THE II ,' MW 18„SD 18 SD i ii I P2 I i� PUBLIC RIGHT-OF-WAY, PRIVATE ROADWAYS AND TRAVELWAYS. ■— - - - - - - - - - - - - - -- - - II - - - - - - - - - - - - - - - - -- - --- - --- - --- - --- - - II e€ao I I easo— - - - - - - II - - - 7 INSTALL y— - - - - - - - - - - - - - - - - - - - - - - - - --- - -- - - - - - - - - - - — BETWEEN THE POTABLE WATER SYSTEM AND THE PRESSURE IRRIGATION • - — — — — — — — "PIRR 6"PIRR — — — — —6LPIB.B— — — —— — — — "EIRB_ — — — — — — — — " IBR_ — — — — 6"PIRR 6 pIRR 6"PIRR 6"PIRR "p�RR x 6"PIRR SYSTEM.THE DEVICE MUST BE APPROVED BY THE IDAHO DEPARTMENT OF 542-LF 6-IN PI 57-LF 6-IN P1 1 ENVIRONMENTAL QUALITY(DEQ)AND THE CITY OF MERIDIAN WATER ■� L' DEPARTMENT. 1 INSTALL-6-IN GATE VALVE I c 1 W/THRUST BLOCKS I 8. ALL PRESSURE IRRIGATION PIPE SHALL BE CONSTRUCTED TO SLOPE TO 1 I P1 I 1 DRAINS AND/OR PUMP-OUT STATIONS AS SHOWN ON THE PLANS L - - - - - JNSTALL-6IN 1 GATE VALVE 1 9. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH NAMPA-MERIDIAN CA W/THRUST IRRIGATION DISTRICT STANDARD SPECIFICATIONS FOR IRRIGATION 1 BLOCKS 1 DISTRIBUTION SYSTEMS. 10. PRESSURIZED IRRIGATION SYSTEM IS AN EXTENSION OF THE EXISTING MERIDIAN COMMERCE PARK SYSTEM. ■ 10.1. THE PRESSURE IRRIGATION PUMP SYSTEM IS OWNED AND OPERATED BY cc THE NAMPA-MERIDIAN IRRIGATION DISTRICT.THE IRRIGATION Q 0 20' 40' DISTRIBUTION SYSTEM IS OWNED AND OPERATED BY THE MERIDIAN Pressure Irrigation Main COMMERCE PARK OWNER'S ASSOCIATION. 10.2. THE SYSTEM IS CONNECTED TO CITY OF MERIDIAN POTABLE WATER Horizontal Scale: 1" = 20' SYSTEM FOR SECONDARY SOURCE. cc Sheet Notes: NON# Oy INSTALL BLOW-OFF 1 1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROPRIATE LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE 1 EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING R/W GIRR WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL 8-LF 6-IN PI DAMAGES WHICH MIGHT OCCUR BY HIS FAILURE TO EXACTLY LOCATE X 1 AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. i \ INSTALL 45°BEND W.THRUST BLOCK CD PRESSURE IRRIGATION SLEEVE \ 2. SEE SHEET C6.03 FOR NAMPA-MERIDIAN IRRIGATION STANDARD DETAILS. (TYP). SEE SHEET C6.03. 1 CZ9�\\ INSTALL 45°BEND INSTALL 6-IN TEE WITH 2-6-IN PRESSURE IRRIGATION PRESSURE IRRIGATION SLEEVE W.THRUST BLOCK GATE VALVES W/THRUST BLOCKS RISER (TYP). SEE SHEET C6.03. (TYP). SEE SHEET C6.03. z Keynotes. Q w 45-LF 6-IN PI 290-LF 6-IN PI 290-LF 6-IN PI m oc �_ 6"PIRR X 6"PIRR 6"PIRR 6"PIRR 6"PIRR 6"PIRR 6"PIRR P1 POTABLE WATER MAIN CROSSING SEE NOTE N0. 3 ON THIS SHEET. w CV �� - - - - -- - - - ^� G T �� II C900 PVC SLEEVE/CONDUIT. DIAMETER SHALL BE TWO TIMES THE PRESSURE IRRIGATION SLEEVE 1' P2 DIAMETER OF THE PRESSURE IRRIGATION MAIN. (TYP). SEE SHEET C6.03. I - Revisions PRESSURE IRRIGATION SLEEVE (TYP). SEE SHEET C6.03. R1WR/W R/W R/W R/W R/W R/W 1 — — — — — — — — 1211W 121V 1211W 12"W 12"W 12"W 12"W 12"W 121, Cr 1 P1 CA m T I I I — —zCL — — — — — — — — v 38+32.98 38+00 37 00 CC Qc 36 00 35+00 34100 LL. T SAN PRESSURI W. Grand Mogul Dr I (TYP). SEE /W R/W R V�V R/W R/W I c O 18" D 18"S 18"SD 18"SD I I 11 II I mw I II - -- - - -- - - - - - - - - - - - - - - - - - - - - - - E — — — — — — ——— ——— — ——— — ——— — ——— — ——— — ——— ZONAL �1sT I I GIRR LXX "� " R-R IR — — ——— — —— " IRIS-- - - - - - - 4"PIRR 6"PIRR I 542-LF 6-IN PI 10961 EP " I PRESSURE IRRIGATION SLEEVE PRESSURE IRRIGATION \�� I (TYP). SEE SHEET C6.03. RISER (TYP). SEE SHEET C6.03. Jq TE OF �0 1 �N DEN PRESSURE IRRIGATION SLEEVE 1 E (TYP). SEE SHEET C6.03. INSTALL 6-IN TEE WITH 3-6-1 GATE VALVES 11/24/2025 - / W HRUST BLOCKS 1 Project No.: 124186 Date of Issuance: 11-24-2025 Project Milestone: PERMIT SUBMITTAL RE 1 _ - 1 Pressure Irrigation E v Pressure Irri 0 20' 40' Main QE ation Maino g C6mO2 Horizontal Scale: 1" = 20' LL�o